Eterna FLD10PIRBK User manual

PG 6 PG 1
Model:
FLD10PIRBK / FLD20PIRBK / FLD30PIRBK / FLD50PIRBK
FLD10PIRWH / FLD20PIRWH / FLD30PIRWH / FLD50PIRWH
120°PIR LED Floodlights With Mounting Bracket
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION
AND RETAIN FOR FUTURE REFERENCE
INSTALLATION INSTRUCTIONS
A guide for qualied electricians
Visit our website: www.eterna-lighting.co.uk Made in ChinaIssue 0119
1m
Pack Contents:
1 x LED oodlight
complete with
mounting bracket
874/2012
MODELNO.
FLDPIR RANGE
LED LAMP SPECIFICATIONS: 10W 20W 30W 50W
Luminaire lumens (with
diuser) 800 lm 1600 lm 2400 lm 4000 lm
Lumens from chip (no
diuser) 900 lm 1800 lm 2700 lm 4500 lm
Useful lumens 740 lm 1480 lm 2230 lm 3720 lm
Rated Wattage 10W 20W 30W 50W
Rated luminous ux 740 lm 1480 lm 2230 lm 3720 lm
Nominal life time of the lamp 25,000 hrs 25,000 hrs 25,000 hrs 25,000 hrs
Colour temperature 4000K 4000K 4000K 4000K
Number of switching cycles
before premature lamp
failure
12500 12500 12500 12500
Warm-up time up to 60% of
the full light output Instant full light Instant full light Instant full light Instant full light
Dimmable No No No No
Nominal beam angle 120° 120° 120° 120°
Rated power 10W 20W 30W 50W
Rated lamp lifetime 25,000 hrs 25,000 hrs 25,000 hrs 25,000 hrs
Lamp power factor >0.9 >0.9 >0.9 >0.9
Lumen maintenance factor at
end of nominal life 70% 70% 70% 70%
Starting time <0.5s <0.5s <0.5s <0.5s
Colour rendering ≥80 ≥80 ≥80 ≥80
Colour consistency Within a six step
Macadam ellipse
Within a six step
Macadam ellipse
Within a six step
Macadam ellipse
Within a six step
Macadam ellipse
Rated peak intensity 255cd 509cd 764cd 1273cd
Rated beam angle 120° 120° 120° 120°
Voltage / Frequency 240V~50Hz 240V~50Hz 240V~50Hz 240V~50Hz
Not suitable for accent lighting

INTRODUCTION:
The oodlight incorporates a PIR (Passive Infra Red)
sensing device which continuously scans a preset
operating zone and immediately switches the light
on when it detects movement in that area.
This means that whenever movement is detected
within the range of the sensor the light will switch
on automatically to illuminate the area you have
selected to light. While there is movement within
range of the unit the light will remain on.
READ THIS FIRST:
Check the pack and make sure you have all of the
parts listed on the front of this booklet. If not,
contact the outlet where you bought this product.
This product must be installed by a competent
person in accordance with the current building and
IEE wiring regulations.
As the buyer, installer and/or user of this product it
is your own responsibility to ensure that this tting
is t for the purpose for which you have intended
it. Eterna Lighting cannot accept any liability for
loss, damage or premature failure resulting from
inappropriate use.
This product is designed and constructed according
to the principles of the appropriate British Standard.
Switch o the mains before commencing installation
and remove the appropriate circuit fuse or lock o
MCB.
This unit is suitable for outdoor use.
This product is designed for permanent connection
to xed wiring: this must be a suitable circuit
(protected with the appropriate MCB or fuse).
Before making xing hole(s), check that there are no
obstructions hidden beneath the mounting surface
such as pipes or cables.
Make sure that the xings are strong enough to
support the considerable weight of the tting and
hold it rigidly.
The lamp must be positioned so that there is at
least 1M between the luminaire and any illuminated
surface.
When making connections ensure that the terminals
are tightened securely and that no
strands of wire protrude. Check that the terminals are
tightened onto the bared conductors and not onto
any insulation.
This product must be connected to Earth
termination.
This product is not intended to be used by children
and persons with sensory, physical and/or mental
impairments that would prevent them from using it
safely.
You are advised at every stage of your installation to
double-check any electrical connections you have
made. After you have completed your installation
there are electrical tests that should be carried out,
these tests are specied in the current IEE wiring and
building regulations.
SPECIFICATIONS:
• 10W-30W detection range: max. 9m at approx. 120°
scan.
• 50W detection range: 4-8m (adjustable) at approx.
120° scan.
• Duration time adjustment: (10±3) seconds to (10±3)
minutes.
• Lux adjustment: 5-2000lux.
WHERE TO FIT YOUR PIR FLOODLIGHT:
To achieve best results we suggest you take the
following points into consideration:
Do not mount on a surface that has vibration.
Ideally the PIR oodlight should be mounted 2.5
metres to 3 metres above the area to be scanned
(refer to g.1 (10-30W) and g.2 (50W) opposite).
To avoid damage to the unit do not aim sensor
towards sun.
Avoid positioning the sensor unit adjacent to a
bright light source which may prevent the unit from
operating when the lux control is set to operate in
dark conditions.
Avoid nuisance / false triggering by directing sensor
away from:
• Trees and shrubs
• Reective surfaces such as smooth white walls
• Swimming pools
• Heat sources such as boiler ues
The PIR sensor scanning specications
(approximately 8 metres at 120°) may vary slightly
depending on the mounting height and location.
The detection range of the unit may also alter with
temperature change. Before selecting a place to
install your PIR oodlight you should note that
movement across the scan area is more eective
than movement directly towards or away from the
sensor. (Refer to g.3 opposite).
If movement is made walking directly towards or
away from the sensor and not across the sensor
the apparent detection range will be substantially
reduced (refer to g. 4 opposite).
2.5M
3M 6M 9M
120˚
Approx
10-30W
2.5M
4M 6M 8M
120˚
Approx
50W
Fig 1
Fig 2
EFFECTIVE:
Movement across
scan area
LESS EFFECTIVE:
Movement
directly in front
of scan area
Fig 3
Fig 4
PG 2 PG 3
10W: 65mm
20W: 65mm
30W: 75mm
50W: 75mm
Fixing slots on bracket

INSTALLATION:
01) Switch o the mains before commencing
installation.
02) Using the bracket as a template mark and then
drill the appropriate xing holes.
03) Secure the bracket with suitable xings.
04) Unscrew connector on back of tting and make
the electrical connections:
Live - Brown / Red
Neutral - Blue / Black
Earth - Yellow / Green
05) Ensure the connector is secured tightly to
maintain IP rating.
06) Adjust the direction of the oodlight and tighten
the xings on the back of the tting.
07) Restore mains power.
08) Adjust the PIR sensor to the desired settings.
UNDERSTANDING THE CONTROLS:
(Please refer to Fig. 5 / 6 below)
ADJUSTING THE DURATION TIME:
The length of time the unit remains switched on
after activation can be adjusted from (10±3) seconds
to (10±3) minutes approximately. Rotating the TIME
screw from (+) to (-) will reduce the duration time.
Note: Once the light has been triggered by the PIR
sensor any subsequent detection will start the timed
period again from the beginning.
ADJUSTING THE LUX CONTROL LEVEL:
The Lux control module has a built-in sensing device
(photocell) that detects daylight and darkness. The
(R) position denotes that the oodlights can work
at day and night, and the () position only work at
night. You can set to operate the unit at the desired
level by adjusting the LUX screw.
SETTING THE CONTROLS WALK TEST:
Turn the Lux control screw to light (R) & ensure
that the TIME control screw is set at the minimum
duration time (-) position. The oodlight will now
switch on and remain on for about 10 seconds after
each detection.
01) Adjust time control to required setting.
02) To set the light level at which the oodlight will
automatically switch “on” at night, turn the LUX
control screw from daylight (R) to night (). If
the oodlight is required to switch on earlier, e.g.
dusk, wait for the desired light level, then slowly
turn the LUX control screw towards daylight while
someone walks across the center of the area to
be detected. When the oodlight switches on
stop adjusting. You may need to make further
adjustments to achieve your ideal light level
setting.
50W VERSION ONLY ADJUSTING THE
SENSITIVITY:
The sensitivity means the maximum distance which
PIR sensor can be triggered by movement - turning
the SENS knob from (+) to (-) will decrease the
sensitivity.
CLEANING:
• To avoid dust build-up and ensure proper
functioning of the oodlight, please wipe the
sensor lens lightly with a damp cloth every 3
months.
• Disconnect the power and clean the exterior only of
this tting with a moist (not wet) cloth.
• Do not use any chemical or abrasive cleaners.
TROUBLESHOOTING AND USER HINTS:
Note: all passive infra red detectors are more sensitive in cold and dry weather than warm and wet weather.
PROBLEM POSSIBLE CAUSE SUGGESTED REMEDY
Light does not switch on
when there is movement
in the detection area.
1. No mains voltage Check all connections, and MCB Fuses / switches
2. Nearby lighting is too bright Relocate the unit
3. Controls set incorrectly Adjust Lux setting
4. Wired incorrectly Check wiring and conrm its wired as per the
wiring instructions opposite
5. Sensor positioned in wrong direction Relocate the unit
Light switches on for no
apparent reason (false
trigger)
1. Heat sources such as air-con, vents, heaters, ues,
other outside lighting, moving cars trees or shrubs
are activating sensor Relocate the unit
2. Interference from on/o switching of electric
fans or lights on the same circuit as your security
oodlight.
(This problem does not always occur but a faulty
switch or noisy uorescent light may cause the
security oodlight to switch on)
Should the false triggering become, troublesome,
consider:
(a) Replacing a faulty switch
(b) Replacing noisy uorescent tubes and/or
starters
(c) Connecting the oodlight to a separate
circuit (in most cases where one or more of
the above suggestions have been carried out,
false triggering has been reduced)
3. Reection from swimming pool, or reective
surface such as smooth white walls Relocate the unit
Light remains on Time is set too long Reduce time
Light remains on at
nighttime Possible heat source in detection zone
Cover PIR sensor lens with a thick cloth, if the
light turns o check detection area for heat or
reective source, reposition head and decrease
the sensitivity setting if this control is available
Light switches on during
daylight hours LUX control screw is set to daylight position Turn the LUX control screw to desired light level
setting
When setting the lux
controls in daylight
the detection distance
becomes shorter
Interference by sunlight Re-test at night
Fig 5: 10-30W PIR Controls
Fig 6: 50W PIR Controls
PG 4 PG 5
TIMELUX
TIME LUXSENS EVENTUALLY, YOU MAY WANT TO
REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from
Electrical and Electronic Equipment (European
“WEEE Directive” eective August 2005—UK
WEEE Regulations eective 2nd January 2007).
Environment Agency Registered Producer: WEE/
GA0248QZ.
WHEN YOUR PRODUCT COMES TO THE END OF
ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE
RECYCLE IT WHERE FACILITIES EXIST DO NOT
DISPOSE WITH HOUSEHOLD WASTE.
IF YOU EXPERIENCE PROBLEMS:
If you believe your product is defective, please return
it to the place where you bought it. Our Technical
Team will gladly advise on any Eterna Lighting
product, but may not be able to give specic
instructions regarding individual installations.
LAMP REPLACEMENT:
The light source contained in this luminaire
shall only be replaced by the manufacturer,
service agent or a similar qualied person.
CAUTION, RISK OF ELECTRIC SHOCK.
This manual suits for next models
7
Other Eterna Floodlight manuals

Eterna
Eterna RCFLOOD10 User manual

Eterna
Eterna LEDFL3062 Setup guide

Eterna
Eterna VECORCFL10 User manual

Eterna
Eterna FL157BPC Setup guide

Eterna
Eterna FL124BPIR Setup guide

Eterna
Eterna FL124BPIR User manual

Eterna
Eterna LPIR1030G Setup guide

Eterna
Eterna FL10SMDPIR User manual

Eterna
Eterna SL226W Setup guide

Eterna
Eterna PIR80BK User manual

Eterna
Eterna FL124BPIR Setup guide

Eterna
Eterna FLEDB10S User manual

Eterna
Eterna POLY10PIR User manual

Eterna
Eterna ETH400L User manual

Eterna
Eterna RCFLOOD20 User manual

Eterna
Eterna FL124B User manual

Eterna
Eterna PIRF120BK User manual

Eterna
Eterna PIRF500180 User manual

Eterna
Eterna SAP70MINI Setup guide

Eterna
Eterna FOCUS10PIR User manual