READ THIS FIRST:
Check the pack and make sure you have all of the
parts listed on the front of this booklet. If not,
contact the outlet where you bought this product.
This light tting must be installed by a competent
person in accordance with the current building
and IEE wiring regulations.
As the buyer, installer and/or user of this product it
is your own responsibility to ensure that this tting
is t for the purpose for which you have intended
it. Eterna Lighting cannot accept any liability for
loss, damage or premature failure resulting from
inappropriate use.
This product is designed and constructed according
to the principles of the appropriate British Standard.
Switch o the mains before commencing installation
and remove the appropriate circuit fuse or lock o
MCB.
This unit is suitable for outdoor use.
This product is suitable for installation on surfaces
with normal ammability e.g. wood, plasterboard
and masonry. It is not suitable for use on highly
ammable surfaces (e.g. polystyrene, textiles).
Before making xing hole(s), check that there are no
obstructions hidden beneath the mounting surface
such as pipes or cables.
Make sure that the xings are strong enough to
support the considerable weight of the tting and
hold it rigidly.
The lamp must be positioned so that there is at least
1m between the bulb and any illuminated surface.
Floodlights should be positioned well away from
ammable materials.
Do not attach to surfaces which are damp, freshly
painted or otherwise electrically conductive
(e.g. metallic surfaces).
This product is designed for permanent connection
to xed wiring: this must be a suitable circuit
(protected with the appropriate MCB or fuse).
When making connections ensure that the terminals
are tightened securely and that no strands of wire
protrude. Check that the terminals are tightened
onto the bared conductors and not onto any
insulation.
This product must be connected to an earth
termination.
This product is not intended to be used by children
and persons with sensory, physical and/or mental
impairments that would prevent them from using it
safely.
IMPORTANT - if the external exible cable of this
luminaire is damaged it should be exclusively
replaced by a qualied engineer.
You are advised at every stage of your installation to
double-check any electrical connections you have
made. After you have completed your installation
there are electrical tests that should be carried out,
these tests are specied in the current IEE wiring and
building regulations. If in doubt, consult a qualied
electrician.
Do not carry or lift the oodlight by the mains
supply cable.
LAMP REPLACEMENT:
CLEANING:
Clean this light tting only with a soft dry cloth.
Do not use any chemical or abrasive cleaners.
INSTALLATION:
1. Choose the location for your new light tting
giving considerations to the points listed opposite.
2. Isolate mains.
3. Using the bracket, mark xing points and drill
xing holes, according to your chosen xing
method (xings not included). See diagram
opposite for marking measurements.
4. Terminate loose ends of wire to an appropriate IP
rated junction box or similar, ensuring the Live,
Earth and Neutral polarities are observed.
Live - Brown / Red
Neutral - Blue / Black
Earth - Yellow / Green
5. Restore power and test the luminaire.
6. Adjust oodlight head towards the area to be
illuminated and secure in place.
EVENTUALLY, YOU MAY WANT TO
REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from
Electrical and Electronic Equipment (European
“WEEE Directive” eective August 2005—UK
WEEE Regulations eective 2nd January 2007).
Environment Agency Registered Producer: WEE/
GA0248QZ.
WHEN YOUR PRODUCT COMES TO THE END OF
ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE
RECYCLE IT WHERE FACILITIES EXIST DO NOT
DISPOSE WITH HOUSEHOLD WASTE.
IF YOU EXPERIENCE PROBLEMS:
If you believe your product is defective, please return
it to the place where you bought it. Our Technical
Team will gladly advise on any Eterna Lighting
product, but may not be able to give specic
instructions regarding individual installations.
102mm
103mm
FIXING SLOTS ON BRACKET
FIXING SLOTS ON BRACKET
FLOOD50
FLOOD80
88mm
310mm
FIXING SLOTS ON BRACKET
FLOOD120
FLOOD200
The light source contained in this luminaire
shall only be replaced by the manufacturer,
service agent or a similar qualied person.
CAUTION, RISK OF ELECTRIC SHOCK.
The light source is designed to last the lifetime of the
luminaire.
FIXING SLOTS ON BRACKET