Gigabit Hardened Media Converter
V12
The Port Status LEDs
LEDs State Indication
Steady Power redundant system or
ports function abnormally
FAULT
Off Power redundant system and
ports function normally
Steady Power onPower1
Power2
Power3 Off Power off
Steady LFPT function enabledLFPT Off LFPT function disabled
1000Base-SX/LX/BX
Steady A valid network connection
established for fiber port
Flashing Transmitting or receiving data
ACT stands for Activity
LINK/ACT
Off No valid network connection
established for fiber port
10/100/1000Base-TX
Steady A valid network connection
established for copper port
Flashing Transmitting or receiving data
ACT stands for Activity
LINK/ACT
Off No valid network connection
established for copper port
Steady Connected in full duplex mode
Flashing Collision occurred
COL stands for Collision
FDX/COL
Off Connected in half duplex mode
Steady Connected at 1000Mbps1000 Off Not connected at 1000Mbps
Steady Connected at 100Mbps100 Off Connected at 10Mbps
Functional Description
•Meets NEMA TS1/TS2 Environmental requirements: temperature, shock, and vibration for traffic control equipment.
•Meets EN61000-6-2 & EN61000-6-3 EMC Generic Standard Immunity for industrial environment.
•UL1604 Class 1, Division 2 Classified for use in hazardous locations (applicable to versions with terminal block power option).
•DIP switch configuration for link-fault-pass-through, fiber auto/force mode, and port link down alarm.
•4096 MAC addresses, 2.75M bits buffer memory.
•Supports 802.3/802.3u/802.3ab/802.3z/802.3x. Auto-negotiation and Auto MDI/MDIX.
•Full wire-speed forwarding rate.
•Alarms for power and port link failure by relay output. Relay contact rating with current 1A @ 30VDC, 0.5A @ 120VAC.
•Operating voltage and Max. current consumption: 0.88A @ 12VDC, 0.44A @ 24VDC, 0.22A @ 48VDC. Power consumption: 10.5W Max.
•Power Supply: Redundant DC Terminal Block power inputs or 12VDC DC JACK with 100-240VAC external power supply.
•-40 to 75 (℃℃-40℉to 167℉) operating temperature range. Tested for functional operation @ -40 to℃85 (℃-40℉to 185℉).
•Supports DIN-Rail, Panel, or Rack Mounting installation.
Assembly, Startup, and Dismantling
•Assembly: Place the media converter on the DIN rail from above using the slot. Push the front of the media converter toward the mounting
surface until it audibly snaps into place.
•Startup: Connect the supply voltage to start up the media converter via the terminal block (or DC JACK).
•Dismantling: Pull out the lower edge and then remove the media converter from the DIN rail.