The Clever Metering Company
2
I. Shows that the battery is charging, signal strength is 15, 3G network and frequency 2100MHz. R
means that the device is logged into home network and the sign left of the R shows that it is
connected.
II. Scanned network.
III. Signal strength in dBm and in parenthesis the corresponding value, which is a value between 1 and 31.
IV. Signal Strength Bar.
V. Minimum and maximum signal strength value during scan.
VI. LAC: The Local Area Network Code, CELL: cell identification number.
6. Press any button to abort scanning process and return to main menu.
7. To turn of the device, select Services and press OK.
8. Select Shutdown device and press OK.
Additional Settings
With ETM770 it is possible to make several additional settings.
Set up an ISP connection to PING a server:
1. To make the configurations needed a terminal program or a SMS is used.
2. Send following command: ET-IAPNx=+cgdcont=1, “ip”,”APN”<CR> where x is your own chosen number
and APN is your chosen APN.
3. To set the IP address send: ET-IP1=”Remote Server IP-Address”:”Remote Port” <CR>.
4. Go to Main menu in your ETM770.
5. Select “ISP connect”and press OK.
6. Select “Set APN” and press OK. Here you can see your configured APNs.
7. Select which APN(if you have configured more than one) you want to use and press OK.
8. Return to previous menu.
9. Select “Open ISP Connection” and press OK.
10. When “connected” is shown on the display, return to previous menu. Following figure can also be
seen in the display window:
11. Select which IP-address you want to confirm connection with and press OK.
12. If your installation is sufficient you shall get a “Ping reply OK” back.