3 Configuration & LED’s
The configuration of the converter is done by jumpers located in the top side of the device as it’s shown in the
following figure.
There are two configuration jumpers. They will determine how the converter will work.
JUMPERS
1) ING MODE
Enable/disable the optical fiber to work on ing Mode.
In this mode data receive on the fiber X Port, will be transmitted to the serial port and forwarded to the
fiber TX Port. This way you can create an optical fiber ring.
This mode is not available for S485.
2) Serial communication mode, S485 or S232/ S422
Enable/disable the converter to use the S485 or the S232/ S422 Terminals.
ing mode is not compatible with S485 Mode.
LED’s
TX - Blinks when data is sent to the Optical Fiber
RX / LNK - Blinks when data is received on the Optical Fiber. It also works as Fiber Link, when the LED stays steady
on, the converter is not linked to any other converter.