EXFO FLS-2300B User manual

Artisan Technology Group is your source for quality
new and certied-used/pre-owned equipment
• FAST SHIPPING AND
DELIVERY
• TENS OF THOUSANDS OF
IN-STOCK ITEMS
• EQUIPMENT DEMOS
• HUNDREDS OF
MANUFACTURERS
SUPPORTED
• LEASING/MONTHLY
RENTALS
• ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
REMOTE INSPECTION
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specications, manuals, and documentation
Contact us: (888) 88-SOURCE | sales@artisantg.com | www.artisantg.com
SM
View
Instra

ASE Broadband
Light Source
FLS-2300B
User Guide
P/N: 1034633
March 2002
If the equipment described herein
bears the symbol, the said
equipment complies with the
applicable European Union
Directive and Standards mentioned
in the Declaration of Conformity.
ASE Broadband
Light Source
FLS-2300B
User Guide
P/N: 1034633
March 2002
If the equipment described herein
bears the symbol, the said
equipment complies with the
applicable European Union
Directive and Standards mentioned
in the Declaration of Conformity.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

All rights reserved. No part of this publication may be reproduced, stored in
a retrieval system, or transmitted in any form, be it electronically,
mechanically, or by any other means such as photocopying, recording, or
otherwise, without the prior written permission of EXFO Electro-Optical
Engineering Inc. (EXFO).
Information provided by EXFO is believed to be accurate and reliable.
However, no responsibility is assumed by EXFO for its use nor for any
infringements of patents or other rights of third parties that may result from
its use. No license is granted by implication or otherwise under any patent
rights of EXFO.
EXFO’s Commerce And Government Entities (CAGE) code under the North
Atlantic Treaty Organization (NATO) is 0L8C3.
The information contained in this publication is subject to change without
notice.
© 2002 EXFO Electro-Optical Engineering Inc.
Words that EXFO considers trademarks have been identified as such.
However, neither the presence nor absence of such identification affects
the legal status of any trademark.
Units of measurement in this document conform to SI standards and
practices.
All rights reserved. No part of this publication may be reproduced, stored in
a retrieval system, or transmitted in any form, be it electronically,
mechanically, or by any other means such as photocopying, recording, or
otherwise, without the prior written permission of EXFO Electro-Optical
Engineering Inc. (EXFO).
Information provided by EXFO is believed to be accurate and reliable.
However, no responsibility is assumed by EXFO for its use nor for any
infringements of patents or other rights of third parties that may result from
its use. No license is granted by implication or otherwise under any patent
rights of EXFO.
EXFO’s Commerce And Government Entities (CAGE) code under the North
Atlantic Treaty Organization (NATO) is 0L8C3.
The information contained in this publication is subject to change without
notice.
© 2002 EXFO Electro-Optical Engineering Inc.
Words that EXFO considers trademarks have been identified as such.
However, neither the presence nor absence of such identification affects
the legal status of any trademark.
Units of measurement in this document conform to SI standards and
practices.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Contents
ASE Broadband Light Source iii
Contents
Certification Information ........................................................................................................v
1 Introducing the FLS-2300B ASE Broadband Source ................................... 1
Front Panel .............................................................................................................................2
Back Panel ..............................................................................................................................3
2 Safety Information ....................................................................................... 5
Safety Conventions .................................................................................................................5
General Safety Information .....................................................................................................5
Laser Safety Information .........................................................................................................7
Active LED ...............................................................................................................................9
Source Port .............................................................................................................................9
Electrical Safety Information .................................................................................................10
3 Getting Started with Your Light Source ................................................... 13
Turning the FLS-2300B On and Off .......................................................................................13
FLS-2300B Display .................................................................................................................14
Locking or Unlocking the Source ..........................................................................................15
Activating or Deactivating the Source ...................................................................................17
4 Setting FLS-2300B Parameters ................................................................... 19
Setting Refresh Rate .............................................................................................................20
Setting Backlight ...................................................................................................................21
Setting Contrast ....................................................................................................................21
Setting Video Mode ..............................................................................................................22
Resetting the FLS-2300B .......................................................................................................23
5 Controlling the Source Remotely .............................................................. 25
Setting Remote Command Mode .........................................................................................27
Setting GPIB Address ............................................................................................................28
Setting Baud Rate .................................................................................................................29
Setting Flow Control .............................................................................................................30
Communication Parameters ..................................................................................................31
Standard Status Data Structure ............................................................................................33
Command Structure .............................................................................................................37
General Commands—Quick Reference ..................................................................................39
Specific Commands—Quick Reference ..................................................................................40
Error Messages Format .........................................................................................................41
SCPI Management Errors (System Errors) ..............................................................................42
Contents
ASE Broadband Light Source iii
Contents
Certification Information ........................................................................................................v
1 Introducing the FLS-2300B ASE Broadband Source ................................... 1
Front Panel .............................................................................................................................2
Back Panel ..............................................................................................................................3
2 Safety Information ....................................................................................... 5
Safety Conventions .................................................................................................................5
General Safety Information .....................................................................................................5
Laser Safety Information .........................................................................................................7
Active LED ...............................................................................................................................9
Source Port .............................................................................................................................9
Electrical Safety Information .................................................................................................10
3 Getting Started with Your Light Source ................................................... 13
Turning the FLS-2300B On and Off .......................................................................................13
FLS-2300B Display .................................................................................................................14
Locking or Unlocking the Source ..........................................................................................15
Activating or Deactivating the Source ...................................................................................17
4 Setting FLS-2300B Parameters ................................................................... 19
Setting Refresh Rate .............................................................................................................20
Setting Backlight ...................................................................................................................21
Setting Contrast ....................................................................................................................21
Setting Video Mode ..............................................................................................................22
Resetting the FLS-2300B .......................................................................................................23
5 Controlling the Source Remotely .............................................................. 25
Setting Remote Command Mode .........................................................................................27
Setting GPIB Address ............................................................................................................28
Setting Baud Rate .................................................................................................................29
Setting Flow Control .............................................................................................................30
Communication Parameters ..................................................................................................31
Standard Status Data Structure ............................................................................................33
Command Structure .............................................................................................................37
General Commands—Quick Reference ..................................................................................39
Specific Commands—Quick Reference ..................................................................................40
Error Messages Format .........................................................................................................41
SCPI Management Errors (System Errors) ..............................................................................42
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Contents
iv FLS-2300B
6 Maintenance ................................................................................................45
Cleaning the Front Panel .......................................................................................................45
Cleaning Fixed Connectors ....................................................................................................46
Cleaning Connectors Equipped with EUI/EUA Adapters ........................................................48
Cleaning EUI/EUA Adapters ...................................................................................................50
Cleaning Detector Ports ........................................................................................................52
Replacing the Fuse ................................................................................................................53
Recalibrating the Unit ...........................................................................................................54
Software Upgrades ...............................................................................................................55
7 Troubleshooting ..........................................................................................59
FLS-2300B Error Messages ....................................................................................................59
GPIB Troubleshooting ...........................................................................................................63
Using the Online Help ...........................................................................................................64
Finding Information on the EXFO Web Site ..........................................................................64
Contacting the Technical Support Group ..............................................................................65
Transportation ......................................................................................................................66
8 Warranty ......................................................................................................67
General Information .............................................................................................................67
Liability .................................................................................................................................68
Exclusions .............................................................................................................................68
Certification ..........................................................................................................................68
Service and Repairs ...............................................................................................................68
EXFO Service Centers Worldwide ..........................................................................................70
A Technical Specifications ..............................................................................71
B Remote Control Commands .......................................................................73
Common Commands ............................................................................................................73
Specific Commands ..............................................................................................................82
Index .................................................................................................................87
Contents
iv FLS-2300B
6 Maintenance ................................................................................................45
Cleaning the Front Panel .......................................................................................................45
Cleaning Fixed Connectors ....................................................................................................46
Cleaning Connectors Equipped with EUI/EUA Adapters ........................................................48
Cleaning EUI/EUA Adapters ...................................................................................................50
Cleaning Detector Ports ........................................................................................................52
Replacing the Fuse ................................................................................................................53
Recalibrating the Unit ...........................................................................................................54
Software Upgrades ...............................................................................................................55
7 Troubleshooting ..........................................................................................59
FLS-2300B Error Messages ....................................................................................................59
GPIB Troubleshooting ...........................................................................................................63
Using the Online Help ...........................................................................................................64
Finding Information on the EXFO Web Site ..........................................................................64
Contacting the Technical Support Group ..............................................................................65
Transportation ......................................................................................................................66
8 Warranty ......................................................................................................67
General Information .............................................................................................................67
Liability .................................................................................................................................68
Exclusions .............................................................................................................................68
Certification ..........................................................................................................................68
Service and Repairs ...............................................................................................................68
EXFO Service Centers Worldwide ..........................................................................................70
A Technical Specifications ..............................................................................71
B Remote Control Commands .......................................................................73
Common Commands ............................................................................................................73
Specific Commands ..............................................................................................................82
Index .................................................................................................................87
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Certification Information
ASE Broadband Light Source v
Certification Information
F.C.C. Information
Electronic test equipment is exempt from Part 15 compliance (FCC) in
the United States, but EXFO makes reasonable efforts to ensure this
compliance.
Information
Electronic test equipment is subject to the EMC Directive in the European
Union. The EN61326 standard prescribes both emission and immunity
requirements for laboratory, measurement, and control equipment.
This unit has been tested and found to comply with the limits for a Class A
digital device. Please refer to the Declaration of Conformity.
CSA Information
This unit received CSA certification under the model name “GO”. The CSA
Certificate Number is 162451. The “C-US” indicator adjacent to the CSA
Mark signifies that the product has been evaluated to the applicable
ANSI/UL and CSA Standards, for use in the United States and Canada.
Independent Laboratory Testing
This unit has undergone extensive testing according to the European Union
Directive and Standards. All pre-qualification tests were performed
internally, at EXFO, while all final tests were performed externally, at an
independent, accredited laboratory. This guarantees the unerring
objectivity and authoritative compliance of all test results.
Certification Information
ASE Broadband Light Source v
Certification Information
F.C.C. Information
Electronic test equipment is exempt from Part 15 compliance (FCC) in
the United States, but EXFO makes reasonable efforts to ensure this
compliance.
Information
Electronic test equipment is subject to the EMC Directive in the European
Union. The EN61326 standard prescribes both emission and immunity
requirements for laboratory, measurement, and control equipment.
This unit has been tested and found to comply with the limits for a Class A
digital device. Please refer to the Declaration of Conformity.
CSA Information
This unit received CSA certification under the model name “GO”. The CSA
Certificate Number is 162451. The “C-US” indicator adjacent to the CSA
Mark signifies that the product has been evaluated to the applicable
ANSI/UL and CSA Standards, for use in the United States and Canada.
Independent Laboratory Testing
This unit has undergone extensive testing according to the European Union
Directive and Standards. All pre-qualification tests were performed
internally, at EXFO, while all final tests were performed externally, at an
independent, accredited laboratory. This guarantees the unerring
objectivity and authoritative compliance of all test results.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Certification Information
vi FLS-2300B
IMPORTANT
Use of shielded remote I/O cables, with properly grounded shields
and metal connectors, is recommended in order to reduce radio
frequency interference that may emanate from these cables.
Certification Information
vi FLS-2300B
IMPORTANT
Use of shielded remote I/O cables, with properly grounded shields
and metal connectors, is recommended in order to reduce radio
frequency interference that may emanate from these cables.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Certification Information
ASE Broadband Light Source vii
Electro-Optical Engineering
Application of Council Directive(s): 73/23/EEC - The Low Voltage Directive
89/336/EEC - The EMC Directive
Manufacturer’s Name: EXFO ELECTRO-OPTICAL ENG.
Manufacturer’s Address: 465 Godin Avenue
Vanier, Quebec
Canada G1M 3G7
(418) 683-0211
Equipment Type/Environment: Industrial Scientific Equipment
Trade Name/Model No.: FLS-2300B ASE Braodband Source
Year of Conformity Assessment: 2001
Standard(s) to which Conformity is Declared:
EN 61010-1:1993
A2: 1995
Safety Requirements for Electrical Equipment for Measurement, Control, and
Laboratory Use, Part 1: General Requirements.
EN 55022:1994/
A2: 1997
Limits and Methods of Measurement of Radio Disturbance Characteristics of
Information Technology Equipment.
EN 60825-1:1993/
A11: 1996
Safety of laser products – Part 1: Equipment classifications, requirements, and
user’s guide
EN 61326:1997/
A1: 1998
Electrical Equipment for Measurement, Control and Laboratory
Use - EMC Requirements
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive and Standards.
Manufacturer
Signature:
Full Name: Stephen Bull, E. Eng
Position: Vice-President Research and
Development
Address: 465 Godin Avenue Vanier, Quebec,
Canada
Date: March 11, 2002
DECLARATION OF CONFORMITY
Certification Information
ASE Broadband Light Source vii
Electro-Optical Engineering
Application of Council Directive(s): 73/23/EEC - The Low Voltage Directive
89/336/EEC - The EMC Directive
Manufacturer’s Name: EXFO ELECTRO-OPTICAL ENG.
Manufacturer’s Address: 465 Godin Avenue
Vanier, Quebec
Canada G1M 3G7
(418) 683-0211
Equipment Type/Environment: Industrial Scientific Equipment
Trade Name/Model No.: FLS-2300B ASE Braodband Source
Year of Conformity Assessment: 2001
Standard(s) to which Conformity is Declared:
EN 61010-1:1993
A2: 1995
Safety Requirements for Electrical Equipment for Measurement, Control, and
Laboratory Use, Part 1: General Requirements.
EN 55022:1994/
A2: 1997
Limits and Methods of Measurement of Radio Disturbance Characteristics of
Information Technology Equipment.
EN 60825-1:1993/
A11: 1996
Safety of laser products –Part 1: Equipment classifications, requirements, and
user’s guide
EN 61326:1997/
A1: 1998
Electrical Equipment for Measurement, Control and Laboratory
Use - EMC Requirements
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive and Standards.
Manufacturer
Signature:
Full Name: Stephen Bull, E. Eng
Position: Vice-President Research and
Development
Address: 465 Godin Avenue Vanier, Quebec,
Canada
Date: March 11, 2002
DECLARATION OF CONFORMITY
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

ASE Broadband Light Source 1
1 Introducing the FLS-2300B ASE
Broadband Source
The FLS-2300B Broadband Source is a high-power, unpolarized fiber-optic
source that comes with a standard FC-APC output connector.
By optically pumping an erbium-doped fiber, the C+L-band source emits a
flattened amplified spontaneous emission (ASE) spectrum over the entire
wavelength range.
With this source, there is no need to take a reference at every
measurement. The high-power density of the FLS-2300B ASE Broadband
Source results in a higher dynamic range when measuring a passive device
with an optical spectrum analyzer.
Its unpolarized output makes it particularly suitable for stable and average
loss measurements. It is also ideal for component testing, high-sensitivity
PMD measurements, communication link characterization and fiber
sensing.
The excellent spectral stability of the FLS-2300B source as well as its high
output power stability make this source useful for fast and reliable
characterization of high-loss DWDM passive components such as thin film
filters, arrayed waveguides and fiber Bragg gratings.
The high output power is stable and flat, making it suitable for simulating
uniform noise in receiver bit error rate (BER) tests or testing the gain and
the gain flatness of Raman amplifiers.
Depending on your needs, the FLS-2300B ASE Broadband Source can be
purchased with the gain-flattening option (for applications requiring high
flatness).
ASE Broadband Light Source 1
1 Introducing the FLS-2300B ASE
Broadband Source
The FLS-2300B Broadband Source is a high-power, unpolarized fiber-optic
source that comes with a standard FC-APC output connector.
By optically pumping an erbium-doped fiber, the C+L-band source emits a
flattened amplified spontaneous emission (ASE) spectrum over the entire
wavelength range.
With this source, there is no need to take a reference at every
measurement. The high-power density of the FLS-2300B ASE Broadband
Source results in a higher dynamic range when measuring a passive device
with an optical spectrum analyzer.
Its unpolarized output makes it particularly suitable for stable and average
loss measurements. It is also ideal for component testing, high-sensitivity
PMD measurements, communication link characterization and fiber
sensing.
The excellent spectral stability of the FLS-2300B source as well as its high
output power stability make this source useful for fast and reliable
characterization of high-loss DWDM passive components such as thin film
filters, arrayed waveguides and fiber Bragg gratings.
The high output power is stable and flat, making it suitable for simulating
uniform noise in receiver bit error rate (BER) tests or testing the gain and
the gain flatness of Raman amplifiers.
Depending on your needs, the FLS-2300B ASE Broadband Source can be
purchased with the gain-flattening option (for applications requiring high
flatness).
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Introducing the FLS-2300B ASE Broadband Source
2FLS-2300B
Front Panel
Front Panel
ASE BROADBAND SOURCE
FLS-2300
ENTER
On/Off
Setup
Lock
Unlock
Navigation/
Menu
setting
buttons
Setup menu access
Power
Source Activation/Deactivation
button
Display
Source lock
Confirmation
button
Interlock connector
ACTIVE
Active LED
Optical connector output
Introducing the FLS-2300B ASE Broadband Source
2FLS-2300B
Front Panel
Front Panel
ASE BROADBAND SOURCE
FLS-2300
ENTER
On/Off
Setup
Lock
Unlock
Navigation/
Menu
setting
buttons
Setup menu access
Power
Source Activation/Deactivation
button
Display
Source lock
Confirmation
button
Interlock connector
ACTIVE
Active LED
Optical connector output
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Introducing the FLS-2300B ASE Broadband Source
ASE Broadband Light Source 3
Back Panel
Back Panel
Ver.
Serial port (RS-232 DTE) Fuse holder Power inlet
GPIB port
Electro-Optical Engineering
465 Godin Ave.
Vanier, Que., Canada G1M 3G7
R
GPIB IEEE 488.2
SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, C0, E2
This device complies with part 15 of the FCC rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Made in Canada
P/N
S/N
Ver.
Mfg.
date
QST-151E
Serial Port
MODEL: GO
LR107723
100-240 V
50/60 Hz
2 A
F2AL250 V
Ground
FLS-2300B
12345-AB
A-2.0
November 2001
CUS
P/N
S/N Mfg.
date
Part number
Serial number
Version number
Manufacturing date
Introducing the FLS-2300B ASE Broadband Source
ASE Broadband Light Source 3
Back Panel
Back Panel
Ver.
Serial port (RS-232 DTE) Fuse holder Power inlet
GPIB port
Electro-Optical Engineering
465 Godin Ave.
Vanier, Que., Canada G1M 3G7
R
GPIB IEEE 488.2
SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, C0, E2
This device complies with part 15 of the FCC rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Made in Canada
P/N
S/N
Ver.
Mfg.
date
QST-151E
Serial Port
MODEL: GO
LR107723
100-240 V
50/60 Hz
2 A
F2AL250 V
Ground
FLS-2300B
12345-AB
A-2.0
November 2001
CUS
P/N
S/N Mfg.
date
Part number
Serial number
Version number
Manufacturing date
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

ASE Broadband Light Source 5
2 Safety Information
Safety Conventions
You should understand the following conventions before using the product
described in this manual:
WARNING
Refers to a potential personal hazard. It requires a
procedure which, if not correctly followed, may result
in bodily harm or injury. Do not proceed unless you
understand and meet the required conditions.
CAUTION
Refers to a potential product hazard. It requires a
procedure which, if not correctly followed, may result
in component damage. Do not proceed unless you
understand and meet the required conditions.
IMPORTANT
Refers to any information regarding the operation of
the product which you should not overlook.
General Safety Information
The following safety precautions must be observed during the operation
and servicing of the unit. Failure to comply with these precautions or with
specific indications elsewhere in this manual violates safety standards of
intended use of the unit. EXFO assumes no liability for the user's failure to
comply with these requirements.
➤This unit is intended for indoor use only.
➤Unit covers cannot be removed during operation.
ASE Broadband Light Source 5
2 Safety Information
Safety Conventions
You should understand the following conventions before using the product
described in this manual:
WARNING
Refers to a potential personal hazard. It requires a
procedure which, if not correctly followed, may result
in bodily harm or injury. Do not proceed unless you
understand and meet the required conditions.
CAUTION
Refers to a potential product hazard. It requires a
procedure which, if not correctly followed, may result
in component damage. Do not proceed unless you
understand and meet the required conditions.
IMPORTANT
Refers to any information regarding the operation of
the product which you should not overlook.
General Safety Information
The following safety precautions must be observed during the operation
and servicing of the unit. Failure to comply with these precautions or with
specific indications elsewhere in this manual violates safety standards of
intended use of the unit. EXFO assumes no liability for the user's failure to
comply with these requirements.
➤This unit is intended for indoor use only.
➤Unit covers cannot be removed during operation.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Safety Information
6FLS-2300B
General Safety Information
➤Before powering on the unit, all grounding terminals, extension cords,
and devices connected to it should be connected to a protective
ground via a ground socket. Any interruption of the protective
grounding is a potential shock hazard and may cause personal injury.
➤Whenever the ground protection is impaired, the unit is not to be used
and must be secured against any accidental or unintended operation.
➤Only fuses with the required rated current and specified type (IEC,
250 V, 2 A, fast blow, 0.197 in. x 0.787 in. / 5 mm x 20 mm) may be used
for replacement. Do not use repaired fuses or short-circuited fuse
holders.
➤The unit must be positioned so as not to block the ventilation holes
located on each side of the unit.
➤Any adjustments, maintenance and repair of opened units under
voltage should be avoided and carried out only by skilled personnel
aware of the hazards involved. Do not attempt internal service or
adjustment unless another person qualified in first aid is present. Do
not replace any components while power cable is connected.
➤Operation of any electrical instrument around flammable gases or
fumes constitutes a major safety hazard.
➤Installation of replacement parts or modification of the unit should be
carried out by authorized personnel only.
➤Capacitors inside the unit may be charged even if the unit has been
disconnected from its electrical supply.
Safety Information
6FLS-2300B
General Safety Information
➤Before powering on the unit, all grounding terminals, extension cords,
and devices connected to it should be connected to a protective
ground via a ground socket. Any interruption of the protective
grounding is a potential shock hazard and may cause personal injury.
➤Whenever the ground protection is impaired, the unit is not to be used
and must be secured against any accidental or unintended operation.
➤Only fuses with the required rated current and specified type (IEC,
250 V, 2 A, fast blow, 0.197 in. x 0.787 in. / 5 mm x 20 mm) may be used
for replacement. Do not use repaired fuses or short-circuited fuse
holders.
➤The unit must be positioned so as not to block the ventilation holes
located on each side of the unit.
➤Any adjustments, maintenance and repair of opened units under
voltage should be avoided and carried out only by skilled personnel
aware of the hazards involved. Do not attempt internal service or
adjustment unless another person qualified in first aid is present. Do
not replace any components while power cable is connected.
➤Operation of any electrical instrument around flammable gases or
fumes constitutes a major safety hazard.
➤Installation of replacement parts or modification of the unit should be
carried out by authorized personnel only.
➤Capacitors inside the unit may be charged even if the unit has been
disconnected from its electrical supply.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Safety Information
ASE Broadband Light Source 7
Laser Safety Information
Laser Safety Information
The Laser Radiation Warning Sticker below appears on the shutter of the
optical output connector.
Your FLS-2300B ASE Broadband Source is a Class 3A laser product in
compliance with standard IEC 60825-1: Edition 1.1 1998. It is also a
Class IIIb laser product in compliance with standard 21 CFR 1040 10. It is
potentially harmful if not used with extreme caution.
WARNING
Do not install or terminate fibers while a laser source is active.
Never look directly into a live fiber and ensure that your eyes are
protected at all times.
WARNING
Use of controls, adjustments and procedures for operation and
maintenance other than those specified herein may result in
hazardous radiation exposure.
WARNING
Use of optical instruments with this product will increase eye
hazard.
Safety Information
ASE Broadband Light Source 7
Laser Safety Information
Laser Safety Information
The Laser Radiation Warning Sticker below appears on the shutter of the
optical output connector.
Your FLS-2300B ASE Broadband Source is a Class 3A laser product in
compliance with standard IEC 60825-1: Edition 1.1 1998. It is also a
Class IIIb laser product in compliance with standard 21 CFR 1040 10. It is
potentially harmful if not used with extreme caution.
WARNING
Do not install or terminate fibers while a laser source is active.
Never look directly into a live fiber and ensure that your eyes are
protected at all times.
WARNING
Use of controls, adjustments and procedures for operation and
maintenance other than those specified herein may result in
hazardous radiation exposure.
WARNING
Use of optical instruments with this product will increase eye
hazard.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Safety Information
8FLS-2300B
Laser Safety Information
Light in the 1550 nm wavelength region is invisible to the human eye and
can cause permanent eye damage. Use caution at all times when working
with Class 3A or Class IIIb laser products. Wear appropriate eye protection
and follow laser safety precautions.
The FLS-2300B ASE Broadband Source contains a Class 3A or Class IIIb
laser source, as indicated on the following label(s):
INVISIBLE LASER RADIATION
AVOID DIRECT EXPOSURE TO BEAM
DO NOT STARE INTO BEAM OR VIEW
DIRECTLY WITH OPTICAL INSTRUMENTS
CLASS 3A LASER PRODUCT
IEC 60825-1:Ed. 1.1 1998
CLASS IIIb LASER PRODUCT 21 CFR 1040.10
λ: 1520 to 1620 nm, P
out
maximum: 45 mW
QST432B
Affixed on the top of
the unit
ASE BROADBAND SOURCE
FLS-2300
ENTER
On/Off
Setup
Lock
Unlock
Power
Source Activation/Deactivation
Button
Source Lock Interlock Connector
ACTIVE
Active LED
Optical Connector Output
Safety Information
8FLS-2300B
Laser Safety Information
Light in the 1550 nm wavelength region is invisible to the human eye and
can cause permanent eye damage. Use caution at all times when working
with Class 3A or Class IIIb laser products. Wear appropriate eye protection
and follow laser safety precautions.
The FLS-2300B ASE Broadband Source contains a Class 3A or Class IIIb
laser source, as indicated on the following label(s):
INVISIBLE LASER RADIATION
AVOID DIRECT EXPOSURE TO BEAM
DO NOT STARE INTO BEAM OR VIEW
DIRECTLY WITH OPTICAL INSTRUMENTS
CLASS 3A LASER PRODUCT
IEC 60825-1:Ed. 1.1 1998
CLASS IIIb LASER PRODUCT 21 CFR 1040.10
λ: 1520 to 1620 nm, P
out
maximum: 45 mW
QST432B
Affixed on the top of
the unit
ASE BROADBAND SOURCE
FLS-2300
ENTER
On/Off
Setup
Lock
Unlock
Power
Source Activation/Deactivation
Button
Source Lock Interlock Connector
ACTIVE
Active LED
Optical Connector Output
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Safety Information
ASE Broadband Light Source 9
Active LED
Active LED
The unit has an active LED on its front panel. When lit, this LED indicates
that an optical signal is being emitted from the source port.
On Class III B laser products, the active LED will turn on three seconds
before the laser starts emitting above the Class 1 limit.
Source Port
The optical signal is emitted from the source port (labelled Optical
connector output in figure on page 8). The Laser Radiation Hazard Sticker
below appears on the front panel of the module.
Safety Information
ASE Broadband Light Source 9
Active LED
Active LED
The unit has an active LED on its front panel. When lit, this LED indicates
that an optical signal is being emitted from the source port.
On Class III B laser products, the active LED will turn on three seconds
before the laser starts emitting above the Class 1 limit.
Source Port
The optical signal is emitted from the source port (labelled Optical
connector output in figure on page 8). The Laser Radiation Hazard Sticker
below appears on the front panel of the module.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Safety Information
10 FLS-2300B
Electrical Safety Information
Electrical Safety Information
AC Requirements
The FLS-2300B can operate from any single-phase AC power source
between 100 V and 240 V (50 Hz/60 Hz). The maximum input current is 2 A.
Power Cable
The power cable of the FLS-2300B is its disconnect device (the only way to
be sure the unit is completely powered off is to disconnect its power
cable).
The FLS-2300B uses an international safety standard three-wire power
cable. This cable serves as a ground when connected to an appropriate AC
power receptacle. The type of power cable supplied with each unit is
determined according to the country of destination.
Only qualified electricians should connect new plugs if needed. The color
coding used in the electric cable depends on the cable. New plugs should
meet local safety requirements and include:
➤adequate load-carrying capacity
➤ground connection
➤cable clamp
Safety Information
10 FLS-2300B
Electrical Safety Information
Electrical Safety Information
AC Requirements
The FLS-2300B can operate from any single-phase AC power source
between 100 V and 240 V (50 Hz/60 Hz). The maximum input current is 2 A.
Power Cable
The power cable of the FLS-2300B is its disconnect device (the only way to
be sure the unit is completely powered off is to disconnect its power
cable).
The FLS-2300B uses an international safety standard three-wire power
cable. This cable serves as a ground when connected to an appropriate AC
power receptacle. The type of power cable supplied with each unit is
determined according to the country of destination.
Only qualified electricians should connect new plugs if needed. The color
coding used in the electric cable depends on the cable. New plugs should
meet local safety requirements and include:
➤adequate load-carrying capacity
➤ground connection
➤cable clamp
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Safety Information
ASE Broadband Light Source 11
Electrical Safety Information
WARNING
To avoid electrical shock, do not operate the unit if there are signs
of damage to any part of the outer surface (covers, panels, etc.).
To avoid serious injury, the following precautions must be observed
before powering on the unit:
➤If the unit is to be powered via an auto-transformer for voltage
reduction, the common terminal must be connected to the
grounded power source pole.
➤Insert the plug into a power outlet with a protective ground
contact. Do not use an extension cord without a protective
conductor.
➤Before powering on the unit, the protective ground terminal of
the unit must be connected to a protective conductor using the
unit power cord.
➤Do not tamper with the protective ground terminal.
Safety Information
ASE Broadband Light Source 11
Electrical Safety Information
WARNING
To avoid electrical shock, do not operate the unit if there are signs
of damage to any part of the outer surface (covers, panels, etc.).
To avoid serious injury, the following precautions must be observed
before powering on the unit:
➤If the unit is to be powered via an auto-transformer for voltage
reduction, the common terminal must be connected to the
grounded power source pole.
➤Insert the plug into a power outlet with a protective ground
contact. Do not use an extension cord without a protective
conductor.
➤Before powering on the unit, the protective ground terminal of
the unit must be connected to a protective conductor using the
unit power cord.
➤Do not tamper with the protective ground terminal.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Other manuals for FLS-2300B
1
Table of contents
Other EXFO Laboratory Equipment manuals
Popular Laboratory Equipment manuals by other brands

Owen Mumford
Owen Mumford Autoject 2 Instructions for use

VICI
VICI Cheminert C52 Installation and Maintenance

Agilent Technologies
Agilent Technologies Intuvo 900 Safety manual

Bibby Sterilin
Bibby Sterilin Stuart SM4 Instructions for use

LEEC
LEEC C100 user manual

Klein Tools
Klein Tools TI222 instruction manual

Retsch
Retsch AS 400 control manual

MSTRONIC
MSTRONIC MIT-33G Installation

erlab
erlab Captair Store Midcap AVPD 804 Assembly instructions

Idaho
Idaho LightScanner Start-Up and Installation Instructions for Users

Shimadzu
Shimadzu AP W-AD Series instruction manual

MedKlinn
MedKlinn Home Asens+ Series operating manual