Exsys EX-6124 User manual

Vers. 1.0 / 10.02.21
Ethernet to 4x Serial RS-232/422/485
EX-6124
Ethernet zu 4x Seriell RS-232/422/485
Manual
Anleitung

2
Deutsch EX-6124
1. Beschreibung···································································································· 3
2. Lieferumfang····································································································· 3
3. Aufbau, Anschlüsse & LED‘s··············································································4-5
3.1 Aufbau························································································································ 4
3.2 Anschlüsse & LED‘s····································································································4-5
4. Hardware Installation··························································································· 6
5. Konfiguration des Geräteserver ············································································· 7
6. VCOM Admin Utility ······················································································· 8-12
7. DIP-Schalter Einstellungen ·················································································13
8. Reinigung········································································································14
9. Technische Daten ·····························································································14
10. Technische Zeichnung ·······················································································14
Inhaltsverzeichnis
Index
© Copyright 2021 by EXSYS Vertriebs GmbH. All Rights Reserved
1. Description ······································································································15
2. Extent of Delivery······························································································15
3. Layout, Connections & LED’s········································································· 16-17
3.1 Layout ······················································································································ 16
3.2 Connections & LED‘s······························································································· 16-17
4. Hardware Installation ·························································································18
5. Configuration of the Device Server ·······································································19
6. VCOM Admin Utility ····················································································· 20-24
7. DIP-Switch Settings···························································································25
8. Cleaning··········································································································26
9. Technical Information·························································································26
10. Technical Drawing·····························································································26

3
EX-6124 Deutsch
Der EX-6124 ist ein Serieller Multiprotokoll RS-232/422/485 Geräteserver. Welcher für den An-
schluss von vier seriellen RS-232/422/485 Geräten, einschließlich POS, Barcode-Lesegeräten,
Sensoren, Messgeräten, CNC-Steuerungen und SPS an ein IP-basiertes Ethernet-Netzwerk aus-
gelegt ist. Die seriellen Geräte werden somit an das Netzwerk angeschlossen und sind somit im
Internet zur gemeinsamen Nutzung verfügbar, wobei die Fernkonfiguration über die umfangreichen
Netzwerkprotokolle wie TCP-Server, TCP-Client, UDP, VCOM, serielles Telnet, RFC2217, Remote
-Pair-Master-Slave, Modbus RTU erfolgt. Um abwärtskompatibel mit dem seriellen Legacy-Gerät
zu sein, auf dem die vorhandene COM-Port-Anwendungssoftware läuft, bietet der EX-6124 einen
virtuellen COM-Port-Umleitungstreiber (VCOM), der Ihre serielle Anwendung perfekt migriert, ohne
die Software zu modifizieren. Darüber hinaus können serielle Geräte mit dem Remote-Pair-Master-
Slave-Modus über den Peer-to-Peer-Modus miteinander kommunizieren, ohne dass ein zwischen-
geschalteter PC oder Konvertierungssoftware erforderlich ist.
Merkmale:
• 4x RS-232/422/485 Port über RJ45 Ethernet 10/100Mbps
• Bis 921.6 Kbps Baud Rate
• Serielle Modi: RS-232, RS-422, RS-485 2-Draht & 4-Draht
• Netzwerk Protokolle: TCP Server, TCP Client, UDP, VCOM, Serial Telnet, RFC2217, Remo-
te-Pair-Master-Slave, Modbus Server, Modbus Client und SNMP
• Konfiguration: Windows-basiertes VCOM-Administrator-Dienstprogramm und Web-Browser
• Unterstützt 15KV ESD-Schutz für alle serielle Signale
• Unterstützt 5V über seriellen Anschluss
• Zertifiziert für
Bevor Sie den EX-6124 in Ihr Netzwerk einbinden, überprüfen Sie bitte zuerst den Inhalt der
Lieferung:
• EX-6124
• Netzteil (12V/3A)
• Anleitung
• Treiber CD
1. Beschreibung
2. Lieferumfang
© Copyright 2021 by EXSYS Vertriebs GmbH. All Rights Reserved

4
Deutsch EX-6124
3.1 Aufbau
3. Aufbau, Anschlüsse & LED‘s
© Copyright 2021 by EXSYS Vertriebs GmbH. All Rights Reserved
Status LED
4x Seriell 9 Pin D-SUB Stecker
RJ45 Anschluss 5-24V DC Anschluss für
beiliegendes Netzteil
Power/ACT LED
PoE LED
TXD LEDRXD LED
Reset Schalter
3.2 Anschlüsse & LED‘s
DB 9M (RS-232):
Seriell 9 Pin D-SUB Stecker (RS-232)
Pin Signal Pin Signal Pin Signal
1DCD 4DTR 7RTS
2RXD 5GROUND 8CTS
3TXD 6DSR 9(Power)
Vorderseite:
Rückseite:
5-24V T-Block
für optionales
externes Netzteil
DB 9M (RS-422 & RS-485 4-Draht):
Seriell 9 Pin D-SUB Stecker (RS-422 & RS-485 4-Draht)
Pin Signal Pin Signal Pin Signal
1TXD- 4RXD- 7NC
2TXD+ 5GROUND 8NC
3RXD+ 6NC 9(Power)

5
EX-6124 Deutsch
3. Aufbau, Anschlüsse & LED‘s
3.2 Anschlüsse & LED‘s
© Copyright 2021 by EXSYS Vertriebs GmbH. All Rights Reserved
LED‘s:
LED Name Farbe LED Funktion
Power/Act LED
(RJ45) Grün Ständig an: Am RJ45 liegt Strom an
Blinken: Datenübertragung über das Netzwerk
Aus: Am RJ45 liegt kein Strom an
PoE LED
(RJ45) Orange
Ständig an: Entnahme des Stroms aus dem LAN-Kabel
(nur PoE Modell)
Off: PoE Strom wird nicht entnommen
Status LED
Grün
Blinken: Das Gerät ist eingeschaltet
(25-30 Sekunden werden ca. benötigt)
Aus: Das Gerät ist ausgeschaltet
TXD LED
(rechts) Grün Blinken: Die serielle Schnittstelle sendet Daten
Aus: Die serielle Schnittstelle sendet keine Daten
RXD LED
(links) Grün Blinken: Die serielle Schnittstelle empfängt Daten
Aus: Die serielle Schnittstelle empfängt keine Daten
RJ45 Anschluss:
RJ45 Anschluss
Pin Signal Pin Signal Pin Signal
1BI_DA+ 4BI_DC+ 7BI_DD+
2BI_DA- 5BI_DC- 8BI_DD-
3BI_DB+ 6BI_DB-
DB 9M (RS-485 2-Draht):
Seriell 9 Pin D-SUB Stecker (RS-485 2-Draht)
Pin Signal Pin Signal Pin Signal
1NC 4DATA-(A) 7NC
2NC 5GROUND 8NC
3DATA+(B) 6NC 9(Power)

6
Deutsch EX-6124
© Copyright 2021 by EXSYS Vertriebs GmbH. All Rights Reserved
2. Nun verwenden Sie ein Ethernet Kabel und verbinden Sie dieses mit dem RJ45 Anschluss der
EX-6124 und das andere Ende mit einem PC oder einem Switch.
3. Verbinden Sie nun Ihre seriellen Endgeräte mit den 9 Pin D-SUB Stecker der EX-6124.
4. Schließen Sie jetzt das im Lieferumfang enthaltene 12V Netzteil an die dafür vorhergesehene
12V Buchse der EX-6124 an. Warten Sie etwa 25-30 Sekunden bis die Status LED anfängt zu
blinken. Sobald diese LED blinkt, ist das Gerät betriebsbereit.
Löcher für Wandmontage
4. Hardware Installation
Beachten Sie bitte die folgenden Installationshinweise. Da es große Unterschiede zwischen PC‘s
gibt, können wir Ihnen nur eine generelle Anleitung zum Anschluss der EX-6124 geben. Bei Un-
klarheiten halten Sie sich bitte an die Bedienungsanleitung Ihres Computersystems.
1. Installieren Sie die EX-6124 mit dem optional erhältlichem DIN-Rail Kit auf einer Tragschiene
oder direkt an eine Wand.

7
EX-6124 Deutsch
© Copyright 2021 by EXSYS Vertriebs GmbH. All Rights Reserved
5. Konfiguration des Geräteserver
Werkseinstellung:
Der EX-6124 wird mit folgenden Werkseinstellungen ausgeliefert:
Login User Name: admin
Password: system
IP Address: DHCP (Automatisch zugewiesen)
Network Operation Mode: VCOM Mode
Serial Interface: RS-232
Falls Sie den EX-6124 auf „Werkseinstellung“ zurücksetzen möchten, dann drücken und halten
Sie den Reset Schalter für ca. 3-5 Sekunden gedrückt. Die Status LED erlischt und fängt ein paar
Sekunden später wieder an zu blinken.
Bitte beachten Sie das die Einstellungen nach dem Reset nicht identisch sind mit den Werksein-
stellungen! Wenn Sie den EX-6124 auf „Werkseinstellung“ zurückgesetzt haben, werden Sie fol-
gende Einstellungen im Gerät haben:
Login User Name: admin
Password: system
IP Address: Statisch 192.168.2.1
Network Operation Mode: TCP Server Mode
Serial Interface: RS-232

8
Deutsch EX-6124
© Copyright 2021 by EXSYS Vertriebs GmbH. All Rights Reserved
6. VCOM Admin Utility
Da der EX-6124 mit aktiviertem DHCP-Modus ausgeliefert wurde, ist eine IP-Adresse erforderlich,
um ihn zu konfigurieren. Der EX-6124 erhält standardmäßig automatisch eine IP-Adresse von
einem DHCP-Server (z.B. Ihrem Router). Wenn er nicht mit einem DHCP-Server verbunden ist,
verwenden Sie die Standard-IP-Adresse: 192.168.2.1. Um die IP-Adresse zu ermitteln, müssen
Sie das mitgelieferte VCOM Admin Utility (vspsetup.exe) installieren. Das Installationsprogramm
befindet sich auf der im Lieferumfang enthaltenen Treiber-CD in folgendem Ordner.
Wichtig! Bitte führen Sie das Installationsprogramm mit Rechtsklick „Als Administrator ausführen“
aus!
1. Ermitteln Sie die IP-Adresse: Starten Sie das VCOM Admin Utility (klicken Sie mit Rechtsklick
auf dem Windows-Desktop auf die Verknüpfung VCOM Admin Utility und starten Sie dies mit „Als
Administrator ausführen“).
Klicken Sie auf Remote Device Management > ADD Device > Search
Nachdem der EX-6124 gefunden wurde, klicken Sie auf Cancel, um die Suche abzubrechen.
Klicken Sie auf OK, um den EX-6124 hinzuzufügen.

9
EX-6124 Deutsch
© Copyright 2021 by EXSYS Vertriebs GmbH. All Rights Reserved
6. VCOM Admin Utility
2. Zuordnung der COM-Ports: Um den virtuellen COM-Anschluss zu erstellen und dem seriellen
Gerät zuzuordnen, klicken Sie auf COM Mapping > Add COM > OK
Um die COM-Port-Nummer zu ändern, klicken Sie auf COM Mapping > Modify COM
Der COM1-COM4 wurde nun hinzugefügt!

10
Deutsch EX-6124
© Copyright 2021 by EXSYS Vertriebs GmbH. All Rights Reserved
6. VCOM Admin Utility
Überprüfen Sie bitte ob im Gerätemanager die COM-Port‘s hinzugefügt wurden! Es sollte nun
folgender Einträge im Gerätemanager sichtbar sein:
3. Ändern der Einstellungen der seriellen Schnittstelle: Wenn Sie die Einstellungen der seriel-
len Schnittstelle auf andere Werte als die Standardwerte ändern (z.B. Device Description, Pass-
word, ...), müssen Sie sich zuerst am Device Server anmelden (das Standardpasswort hierfür
"system").
Klicken Sie auf Remote Device Management > Login
Table of contents
Languages:
Other Exsys Adapter manuals

Exsys
Exsys EX-47000 User manual

Exsys
Exsys EX-6011 User manual

Exsys
Exsys EX-6111 User manual

Exsys
Exsys EX-2346 User manual

Exsys
Exsys EX-1225 User manual

Exsys
Exsys EX-1320 User manual

Exsys
Exsys EX-6114 User manual

Exsys
Exsys EX-1452IS User manual

Exsys
Exsys EX-47999 User manual

Exsys
Exsys EX-6084 User manual

Exsys
Exsys EX-1322 User manual

Exsys
Exsys EX-47960 User manual

Exsys
Exsys EX-6112 User manual

Exsys
Exsys EX-47925 User manual

Exsys
Exsys EX-62020POE-SFP User manual

Exsys
Exsys EX-6001 User manual

Exsys
Exsys EX-3505 User manual

Exsys
Exsys EX-1328 User manual

Exsys
Exsys EX-1309-9 User manual

Exsys
Exsys EX-1346 User manual