manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Extech Instruments
  6. •
  7. Thermometer
  8. •
  9. Extech Instruments RH200W User manual

Extech Instruments RH200W User manual

Other Extech Instruments Thermometer manuals

Extech Instruments RH350 User manual

Extech Instruments

Extech Instruments RH350 User manual

Extech Instruments 445713-TP User manual

Extech Instruments

Extech Instruments 445713-TP User manual

Extech Instruments SDL200-NIST User manual

Extech Instruments

Extech Instruments SDL200-NIST User manual

Extech Instruments IR300UV User manual

Extech Instruments

Extech Instruments IR300UV User manual

Extech Instruments IR301 User manual

Extech Instruments

Extech Instruments IR301 User manual

Extech Instruments 42512 User manual

Extech Instruments

Extech Instruments 42512 User manual

Extech Instruments RHT510-NIST User manual

Extech Instruments

Extech Instruments RHT510-NIST User manual

Extech Instruments 42530 User manual

Extech Instruments

Extech Instruments 42530 User manual

Extech Instruments EA15 User manual

Extech Instruments

Extech Instruments EA15 User manual

Extech Instruments 42510 User manual

Extech Instruments

Extech Instruments 42510 User manual

Extech Instruments EA11 User manual

Extech Instruments

Extech Instruments EA11 User manual

Extech Instruments 4465CF User manual

Extech Instruments

Extech Instruments 4465CF User manual

Extech Instruments IR255 User manual

Extech Instruments

Extech Instruments IR255 User manual

Extech Instruments 407907 User manual

Extech Instruments

Extech Instruments 407907 User manual

Extech Instruments RH35 User manual

Extech Instruments

Extech Instruments RH35 User manual

Extech Instruments 42530 User manual

Extech Instruments

Extech Instruments 42530 User manual

Extech Instruments IR100 User manual

Extech Instruments

Extech Instruments IR100 User manual

Extech Instruments SDL500 User manual

Extech Instruments

Extech Instruments SDL500 User manual

Extech Instruments TM100 User manual

Extech Instruments

Extech Instruments TM100 User manual

Extech Instruments 42570 User manual

Extech Instruments

Extech Instruments 42570 User manual

Extech Instruments 42545 User manual

Extech Instruments

Extech Instruments 42545 User manual

Extech Instruments Extech 470 User manual

Extech Instruments

Extech Instruments Extech 470 User manual

Extech Instruments RH401 User manual

Extech Instruments

Extech Instruments RH401 User manual

Extech Instruments K.J.E.T. 422324 User manual

Extech Instruments

Extech Instruments K.J.E.T. 422324 User manual

Popular Thermometer manuals by other brands

Benetech GM900 instruction manual

Benetech

Benetech GM900 instruction manual

Parton PTD-400 manual

Parton

Parton PTD-400 manual

GAME 15900 owner's manual

GAME

GAME 15900 owner's manual

scigiene FP-180 instruction manual

scigiene

scigiene FP-180 instruction manual

Ametek Land UNO U1 600/1600C-L user guide

Ametek Land

Ametek Land UNO U1 600/1600C-L user guide

Delton 981A instruction manual

Delton

Delton 981A instruction manual

Taylor 5286498 instruction manual

Taylor

Taylor 5286498 instruction manual

Baker MM2P instruction manual

Baker

Baker MM2P instruction manual

Chino IR-FA Series instructions

Chino

Chino IR-FA Series instructions

Vive DMD1010 user manual

Vive

Vive DMD1010 user manual

Tarmo 320281 manual

Tarmo

Tarmo 320281 manual

Citizen CTD 504 instruction manual

Citizen

Citizen CTD 504 instruction manual

TFA 14.1500 instruction manual

TFA

TFA 14.1500 instruction manual

Gotemp THB4002 user guide

Gotemp

Gotemp THB4002 user guide

GREISINGER G 1202 Quick reference guide

GREISINGER

GREISINGER G 1202 Quick reference guide

Amprobe TMD-53W user manual

Amprobe

Amprobe TMD-53W user manual

Trotec BP10 operating manual

Trotec

Trotec BP10 operating manual

Radiance instruments RT616 Series product manual

Radiance instruments

Radiance instruments RT616 Series product manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Page1RH200W‐en‐US_v1.08/17
 
USERMANUALforMODELRH200W
WirelessHygro‐Thermometer

ThankyouforselectingtheExtechRH200WWirelessHygro‐ThermometerwithSelf‐Calibration&AutoNightLight.Thisdeviceisshippedfullytested
andcalibratedand,withproperuse,willprovideyearsofreliableservice.Pleasevisitourwebsite(www.extech.com)tocheckforthelatestversionof
thisUserManual,ProductUpdates,andCustomerSupport.
DESCRIPTIONS
MAINUNIT
1. Backlightkey
Innormalmode,shortpressfor5secondsofbacklighting.Pressingotherkeyswillresetthe5‐secondtimer
2. OUT(CHANNEL)/+key
Incalibrationmode,shortpresstoincreasethevalue
Innormalmode,shortpresstoswitchbetweenINDOOR,Channel1~8
Innormalmode,longpresstoenterauto‐cycle(Channel1~8andINDOORreadingswillalternatelydisplayat4‐
secondintervalsandtheicon willdisplay).Fromauto‐cyclemode,shortpresstoreturntonormalmode.
3. M(MODE)key
Incalibrationmode,shortpressforoptions.
Incalibrationmode,longpresstocleardata
4. MIN‐MAX/‐key
Incalibrationmode,shortpresstodecreasevalue
Innormalmode,shortpresstocheckmaximum/minimumtemperatureandhumidityrecords.Shortpressto
returntonormalmode
WithMAXorMINdisplayed,longpresstoresetthedisplayedvalues
5. CALkey
Innormalmode,longpresstoentercalibrationmode
Incalibrationmode,longpresstoreturntonormalmode
6. Autonight‐lightswitch
SlidetoONpositiontoactivatenight‐light(thelightwillautomaticallyturnonindarkareas).Thebrightnessisweakerthannormalbacklight.Slideto
OFFpositiontoturnoffthenight‐lightfunction
7. °C/°Fkey‐Shortpresstotoggletemperatureunits°C/°F
8. SENSORkey
Innormalmode,shortpresstoactivatethereceiverforthecurrentchannel.Theunitwillreceive
signalsfor5minutes
9. RESETkey
Shortpressforafactorydefaultreset.Performaresetifthedisplayfreezesortheunitotherwise
malfunctions.
WIRELESSSENSOR
1. TransmissionstatusLED(flasheswhensensoristransmitting)
2. Wallmount
3. CHANNELslideswitch(assignsensortoChannel1~8)
4. RESETkey(shortpresstoresetthesensor)
5. Batterycompartment(2xAAbatteries)
OPERATION
POWERINGTHEWIRELESSSENSOR
1. Removethebatterydoorofthesensor
2. Insert2‘AA’batteries,observingcorrectpolarity
3. Closethebatterydoor
Notes:Onceasensorisassignedachannelusingthechannelslideswitch,youcanonlyre‐assignachannelbyremovingthebatteriesorresettingthe
unit.Avoidplacingthesensorindirectsunlightorinclementweather.



POWERINGTHEMAINUNIT
1. Removethebatterydoorofthemainunit
2. Install4‘AA’batteriesobservingcorrectpolarity;thenuseapapercliptopresstheRESETkey
3. Closethebatterydoor
4. AllLCDsegmentswillswitchon
Note:Toavoidapairingfailure,powerupthesensorfirst,andthenpresstheRESETkeyonthemainunitonly.
INDOORTEMPERATURE/RELATIVEHUMIDITY
1. ShortpressOUTuntil‘IN”isdisplayed.Theunitisnowdisplayingindoortemperature°C/°FandRelativeHumidity%.
2. Shortpress°C/°Ftoswitchbetween°Cand°F
3. Whenthetemperatureis<‐40°F/°Cor>158°F(70°C),LoorHIwillbedisplayedrespectively.Thehumiditydisplaywillshowdashes:

4. Whenthehumidityis<1%or>99%,LoorHIwillbedisplayed:

COMFORTINDICATION
Thecomfortindicationfeatureisanicon‐basedsystemshowingcomfortlevelbasedonindoorairtemperatureandhumidityrangingfromExcessive
Cold(lefticonbelow)toComfortable(centericon)toExcessiveHeat(righticon).



Note:Comfortindicationcanvaryevenwhenmeasuringthesametemperaturebecauseofthestrongeffecthumidityhasoncomfort.Thereisnocomfort
indicationwhentemperatureis<0°C(32°F)or>60°C(140°F).
TEMPERATURETRENDINGARROWS
Thetemperaturetrendindicatorillustratesthetemperaturechangeovertime.Arrowsindicaterising(lefticonshownbelow),steady(centericon),or
fallingtemperatures(righticon).


MAX/MINRECORDING
ViewtheMAX/MINtemperatureandhumidityreadingssincethelastreset.
1. Innormalmode,shortpressMIN‐MAXtoshowthecurrentmaximumtemperatureandhumidityvalues(diagramonleftbelow);pressagaintoshow
theminimumvalues(diagramincenter);pressagaintoexitthemode(theunitautomaticallyexitsthemodeafterapproximately5seconds).
2. Performamanualreset(clearMAX/MINreadings)bylongpressingMIN‐MAXwhentheunitisdisplayingtheMAX/MINrecords(diagramonright).

RECEIVINGWIRELESSSENSORSIGNALS
1. Innormalmode,shortpressSENSORtostartreceivingdata.
2. Thesignaliconwillflash(diagramonleftbelow)untilreceptionoccurs.After5minutes,theiconwilldisappearifreceptionfails(centerdiagram).
3. ReceivingawirelesssignalafteramanualresetorwhenSENSORispressedwillcausedashestodisplayinthereadingsareawhenwaitingforsignal.
4. Forsuccessfulreception,thesignaliconwillappearasshowninthediagrambelowonright.Theselectedchannelnumberappearsintheboxbelow
theicon.
  
1. Innormalmode,shortpressOUTtoswitchthedisplaybetweenINDOORandCHANNEL1~8.
2. Innormalmode,longpressOUTtotoggleauto‐cyclemodeON/OFF.Auto‐cyclealternatelydisplaysthechannelsat4‐secondintervals(theicon 
willshowwhenauto‐cycleisactive).Inauto‐cyclemodeonlytheactivelycommunicatingchannelswillappear.ShortpressOUTtoexitmode.
3. Tocheckthesignalsfrommultiplewirelesssensors,shortpressOUTrepeatedlyinnormalmode.
5
6
789
1
Page2RH200W‐en‐US_v1.08/17

4. IfthesignalforChannel1~8islostanddoesnotrecoverwithin1hour,thesignaliconwilldisappear.Thetemperatureandhumiditywilldisplay“Er”
forthecorrespondingchannel.
5. Ifthesignaldoesnotrecoverwithin48hours,replacethebatteriesofthe“Er”channel’ssensorandthenpressSENSORonthemainunittopairwith
thesensorsforeach“Er”channelagain.

NoteToinitiatereceptionafterinstallingnewbatteriesinthewirelesssensor,pressSENSOR;otherwise,themainunitwillfailtoreceivethesensor’s
signal.
THESNOWICON 
Whentheoutdoortemperatureis37.4°F(3.0°C)orbelow,thesnowiconwilldisplay.

LOWBATTERYCONDITION
Ifthemainunitorthesensorbatteriesarelow,thelowbatteryicon willdisplay.Theiconwillonlyappearwhenthecorrespondingchannelis
displayed.Forexample,iftheCHANNEL1sensorbatteryislow,theiconwillshowonlywhenCHANNEL1isdisplayed.Replacethebatteriesbyfollowing
instructionsinsectionsPoweringtheWirelessSensorandPoweringtheMainUnit.
TEMPERATURE/HUMIDITYCALIBRATION
1. Innormalmode,longpresstheCALkeytoenterthecalibrationmode.Thecurrentoutdoorchannelor“IN”(indoor)iconwillflash.ShortpressOUT
tochooseIndoor(IN)oraChannelnumber1~8.

2. ShortpressM(MODE)tostepthroughthetemperaturecalibration,humiditycalibration,andchannelselectionmodes.
3. Intemperaturecalibrationmode,usethe[+][‐]keystoadjustthevaluein0.1°steps.Longpresstoscrollquickly.

4. Inhumiditycalibrationmode,usethe[+][‐]keystoadjustthedisplayedvaluein1%steps.Longpresstoscrollquickly.

5. LongpressMatthetemperatureorhumiditycalibrationscreenstoreverttothepreviouscalibrationvaluefortheselectedchannel.
6. Toexitcalibrationmode,longpressCALorwait60secondsfortheunittoexitandreturntothenormalmodeautomatically.
7. Ifthereadingfortheselectedchannelisshowingeitherdashes(flashing)ortheHI/Loindicators,adjustmentwillnotbepossible;returnunitfor
service.
Note:Comfortindicationisacalculationbasedoncalibratedtemperatureandhumiditymeasurements.
IMPORTANTNOTES
Attention!Pleasedisposeofbatteriesandunitinanecologicallysafemanner.
Alwaysplacetheunitawayfrominterferingsourcessuchasmonitors,computers,appliances,andotherdevices.Avoidplacingtheuniton,ornextto,
metalplatesorsurfaces
FCCSTATEMENT
ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:(1)thisdevicemaynotcauseharmful
interference,and(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.

Warning:Changesormodificationstothisunitnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser’sauthorityto
operatetheequipment.

NOTE:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttoPart15oftheFCCRules.Theselimits
aredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,usesandcanradiate
radiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.
However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioor
televisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneor
moreofthefollowingmeasures:
‐Reorientorrelocatethereceivingantenna.
‐Increasetheseparationbetweentheequipmentandreceiver.
‐Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected.
‐Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
ThisdevicecomplieswithIndustryCanadaLicense‐exemptRSS‐210.Operationissubjecttothefollowingtwoconditions:(1)thisdevicemaynotcause
interference,and(2)thisdevicemustacceptanyinterference,includinginterferencethatmaycauseundesiredoperationofthedevice.

FCCResponsibleparty:
CompanyName:FLIRCommercialSystems,Inc.
Address:9TownsendWest,NashuaNH03063USA;Phone:1‐603‐324‐7842

ICID:1590A‐RH200WT;FCCID:IWK‐RH200W‐T;CANRSS‐Gen/CNR‐Gen.
SPECIFICATIONS
MAINUNIT
Indoortemperaturerange/resolution:23°F~122°F(‐5°C~50°C)/0.1°F/°C
TemperatureAccuracy: ±3.6°F(2.0°C),<32°F(<0°C);±1.8°F(1.0°C),32~104°F(0~40°C);±3.6°F(2.0°C),>104°F(>40°C)
Humidityrange/resolution:1%~99%/1%
HumidityAccuracy(at77°F[25°C]):±8%RH(20~39%RH); ±5%RH(40~70%RH); ±8%RH(71~90%RH)
Power:1.5VAAX4(alkalinebatteryrecommended)
Dimensions:5.1(W)x4.4(H)x1.1(D)in.(130x112x27.5mm)
Weight:0.65lbs.(295g)
WIRELESSSENSOR
Outdoortemperaturerange:‐40°F~140°F(‐40°C~60°C)
Outdoorhumidityrange1%~99%
Temperatureresolution:0.1°F/°C
Relativehumidityresolution:1%
Accuracy:SeeaccuracyspecsforMainUnitabove
Wirelesssensorsignalfrequency:433MHz
No.ofremotesensors:Eight(8)unitsmax.
RFtransmissionrange:98.4ft.(30m)maximum
Power:1.5VAAX2batteries(alkalinerecommended)
Dimensions:2.4(W)x4.5(H)x1.5(D)in.(61x113.6x39.5mm)
Weight:0.3lbs.(136g)
Warranty
FLIRSystems,Inc.warrantsthisExtechInstrumentsbranddevicetobefreeofdefectsinpartsandworkmanshipforoneyearfromdateofshipment(asixmonthlimitedwarrantyappliestosensorsandcables).Ifitshouldbecome
necessarytoreturntheinstrumentforserviceduringorbeyondthewarrantyperiod,contacttheCustomerServiceDepartmentforauthorization.Visitthewebsitewww.extech.comforcontactinformation.AReturnAuthorization
(RA)numbermustbeissuedbeforeanyproductisreturned.Thesenderisresponsibleforshippingcharges,freight,insuranceandproperpackagingtopreventdamageintransit.Thiswarrantydoesnotapplytodefectsresultingfrom
actionoftheusersuchasmisuse,improperwiring,operationoutsideofspecification,impropermaintenanceorrepair,orunauthorizedmodification.FLIRSystems,Inc.specificallydisclaimsanyimpliedwarrantiesormerchantability
orfitnessforaspecificpurposeandwillnotbeliableforanydirect,indirect,incidentalorconsequentialdamages.FLIR’stotalliabilityislimitedtorepairorreplacementoftheproduct.Thewarrantysetforthaboveisinclusiveandno
otherwarranty,whetherwrittenororal,isexpressedorimplied.
Calibration,Repair,andCustomerCareServices
FLIRSystems,Inc.offersrepairandcalibrationservicesfortheExtechInstrumentsproductswesell.WeofferNISTtraceablecalibrationformostofour
products.ContactourCustomerServiceDepartmentforinformationoncalibrationserviceavailability.Annualcalibrationsshouldbeperformedtoverify
meterperformanceandaccuracy.Technicalsupportandgeneralcustomerserviceisalsoprovided,refertothecontactinformationprovidedbelow.









Copyright©2017FLIRSystems,Inc.
Allrightsreservedincludingtherightofreproductioninwholeorinpartinanyform
www.extech.com
SupportLines:U.S.(877)239‐8324;International:+1(603)324‐7800
TechnicalSupport:Option3;E‐mail:[email protected]
Repair&Returns:Option4;E‐mail:[email protected]
Productspecificationsaresubjecttochangewithoutnotice
Pleasevisitourwebsiteforthemostup‐to‐dateinformation
www.extech.com
FLIRCommercialSystems,Inc.,9TownsendWest,Nashua,NH03063USA