LUX
3
300 30
Settings
Switch-on time
The time of the receiver switching on can be adjus-
ted within the range of 10 sec to 30 m.
Turning the control knob right [+] increases the
switching on time, turning left [-] reduces the
switching on time.
The sensitivity of the twilight sensor
The sensitivity of the twilight sensor can be adjus-
ted within the range of 3 lx to 2000 lx. Turning the
control knob in the direction of the "moon" icon
will switch the light later, turning it in the direction
of the "sun" - will switch the light earlier.
For the sensor to be active throughout the whole
day, the control knob should be maximally turned
in the direction of the "sun".
Dimensions
TIME
30 min. 10 s
10 min.
5 min.
30 s
90 s
MOTION SENSOR (PIR)
with presence sensor function DR-09
- 1 - - 2 - - 3 - - 4 -
Purpose
The motion sensor is used for automatic and temporary switching
on of lighting if a person or other object appears in places such as
hallways, courtyards, driveways, garages, etc. It is suitable for use
in narrow corridors.
Operation
The sensor detects the infrared radiation sources. It analyzes the
parameters such as the size of the object, the amount of heat
emitted and the speed of movement between sectors of detec-
tion. The sensor detects movement within its own axis and radius.
Movement in the detection area will automatically switch on the
lighting. From this moment the light will stay on, as long as the
sensor detects continuous movement. Only if there is no move-
ment in the detection area triggers the lighting support time.
Another movement in the detection area and its subsequent
disappearance in the course of time measurement starts the sup-
port time from the beginning.
The specific of operation allows using the DR-09 as a presence
sensor. The area of the detection field is: for presence up to 6 m in
diameter and for movement up to 20 m in diameter. The motion
sensor is equipped with a twilight sensor to prevent switching on
the lighting during the day. The detection status and the readiness
to switch on the lighting are only activated after dusk. The acti-
vation time of the sensor can be adjusted by the user using a
potentiometer. In addition, it is possible to adjust the time of
sensor switching on within the range of 10 s÷30 m.
Changes in temperature can affect the motion detection.
Diagram
tOFF tOFF
<tOFF
Area of setection
2÷6 m
max. 10 m max. 10 m
Sensor installation height
and adjustable range of sensor detection
The direction of movement in the detection area
5 908312 599890
The minimum distance between the sensor and the light
source is 60 cm. If the motion sensor is installed too
close to the switched light source, the system may be
activated, which means that the sensor will automa-
tically switch on and off the light source. It is necessary
to move the sensor to an appropriate distance away
from the light source.
presence - 6 m
movement - 20 m
56 mm
102 mm
57 mm
28 mm
90 mm
F&F Filipowski sp. j.
Konstantynowska 79/81 95-200 Pabianice
phone/fax: (+48 42) 215 23 83 / 227 09 71 POLAND
http://www.fif.com.pl e-mail: biuro@fif.com.pl
WARRANTY. The F&F products are
covered by a warranty of the 24 months
from the date of purchase. Effective only
with proof of purchase.
Contact your dealer or directly with us.
More information how to make a com-
pliant can be found on the website:
www.fif.com.pl/reklamacje
Do not dispose of this device in the trash along with other waste! According
to the Law on Waste, electro coming from households free of charge and can
give any amount to up to that end point of collection, as well as to store the
occasion of the purchase of new equipment (in accordance with the principle
of old-for-new, regardless of brand). Electro thrown in the trash or abandoned
in nature, pose a threat to the environment and human health.
Connection scheme
Power table
Montaż
1. Remove the external sensor cover - squeeze the housing from
both sides with your hand and gently pull it out of the internal
housing.
2. Disconnect the power supply.
3. Connect the wires according to the wiring diagram.
4. Fasten the base to the floor with two screws.
6. Set the sensitivity of the twilight sensor and the activation time.
7. Assemble the sensor housing - press it onto the internal housing.
8. Switch on the sensor power supply.
D190130
The above data are indicative only and will depend to a large extent on
the construction of the specific receiver (especially LED bulbs, energy-
saving lamps, electronic transformers and pulse power supplies),
switching frequency and operating conditions.
More information on the website: www.fif.com.pl.
Technical data
power supply 230 V AC
maximum load current (AC-1) 10 A
twilight activation threshold 3÷2000 lx
motion detection 0,6÷1.5 m/sec
switch-on time 10 sec÷30 min. (±2 min.)
area of vertical detection 360°
max. radius of detection (T<24°C) 10 m
sensor mounting height 2÷6 m
power consumption
standby 0.10 W
on 0.45 W
terminal 1.5 mm² screw terminals
tightening torque 0.3 Nm
working temperature -20÷40°C
dimensions 102×102 mm, h= 55 mm
mounting surface-mounted
protection level IP20
CE declaration
A copy of the CE declaration can be downloaded from the website:
www.fif.com.pl from the product subpage.
The sensor is inactive for the first 30 seconds after the
power supply is switched on. During this time, the PIR
system warms up.
If the motion sensor is installed too close to the switched
light source, the system may be activated, which means
that the sensor will automatically switch on and off the
light source. It is necessary to move the sensor to an
appropriate distance away from the light source.
The motion sensor can work indoors and outdoors in
places where it is not exposed to direct rain or snowfall
and to the possibility of splashing the sensor housing
and its electrical connection points with water or other
liquid. Avoid locations with large objects in the
detection area such as trees that can be moved by the
wind. Do not install the sensor in close proximity to
heating, air conditioning, and lighting equipment
- 5 - - 6 - - 8 -- 7 -
N
L
DR-09
NA L
N
A
L
A N L
L
N
~
OUT IN ~
A - red, N - blue, L - brown
2000 W 300 W
2000 W
incandescent fluorescent energy-saving
halogen LED
300 W 300 W

Other F&F Accessories manuals

F&F DRM-02 User manual

F&F

F&F DRM-02 User manual

F&F DRM-01 24 V User manual

F&F

F&F DRM-01 24 V User manual

F&F DRM-07 User manual

F&F

F&F DRM-07 User manual

F&F DRM-08 5 9 0 8 3 1 2 5 9 9 8 8 3 Functioning TIME 12min. 10s 6min. 3min. 30s 90s LUX 3 300 30 SENS + - F&F Filipowski sp. j.... User manual

F&F

F&F DRM-08 5 9 0 8 3 1 2 5 9 9 8 8 3 Functioning TIME 12min. 10s 6min. 3min. 30s 90s LUX 3 300 30 SENS + - F&F Filipowski sp. j.... User manual

F&F CKF-319 TRMS User manual

F&F

F&F CKF-319 TRMS User manual

F&F DR-04B User manual

F&F

F&F DR-04B User manual

F&F DR-09-IP65 User manual

F&F

F&F DR-09-IP65 User manual

F&F DR-03 User manual

F&F

F&F DR-03 User manual

Popular Accessories manuals by other brands

Dixon FloTech FT201-12 Maintenance & Operating Instructions

Dixon

Dixon FloTech FT201-12 Maintenance & Operating Instructions

RKC INSTRUMENT CZ-200P instruction manual

RKC INSTRUMENT

RKC INSTRUMENT CZ-200P instruction manual

RADWAG HRP 16 user manual

RADWAG

RADWAG HRP 16 user manual

PCB Piezotronics IMI SENSORS HT642A02 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS HT642A02 Installation and operating manual

Siemens QBM97 Series user guide

Siemens

Siemens QBM97 Series user guide

Axon Body 2 quick start guide

Axon

Axon Body 2 quick start guide

TLC SEC150 introduction

TLC

TLC SEC150 introduction

OBO Bettermann Deskbox DB Mounting instructions

OBO Bettermann

OBO Bettermann Deskbox DB Mounting instructions

Livoo DOM394 instruction manual

Livoo

Livoo DOM394 instruction manual

Solid S7753 manual

Solid

Solid S7753 manual

Intermec Oracle-Ready CK31 instructions

Intermec

Intermec Oracle-Ready CK31 instructions

GFL 7601 Original operating instructions

GFL

GFL 7601 Original operating instructions

National Instruments NI 9944 user guide

National Instruments

National Instruments NI 9944 user guide

Beckett Fountain Cleanser FP4 specification

Beckett

Beckett Fountain Cleanser FP4 specification

3Doodler Create+ user manual

3Doodler

3Doodler Create+ user manual

Roland DUO-CAPTURE owner's manual

Roland

Roland DUO-CAPTURE owner's manual

Huawei NetCol8000-C070 user manual

Huawei

Huawei NetCol8000-C070 user manual

XD COLLECTION P322.23 Series manual

XD COLLECTION

XD COLLECTION P322.23 Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.