Fermax Memokey 100C Assembly instructions

Pag 1
SISTEMAS
MEMOKEY 100C
MEMOKEY 100C
PORTADA
PROGRAMMER
MANUAL

Pag 2
SISTEMAS
MEMOKEY 100C
MEMOKEY 100C
FERMAX 100C MEMOKEY KIT INSTRUCTIONS.
Edition: V05/07.
This technical document of an informative nature is issued by FERMAX ELECTRONICA
S.A.E. The company reserves the right to modify any of the product features referred to
herein at any time without prior notice. Said changes will be reflected in subsequent
editions of the same.
ENGLISH

Pag 3
SISTEMAS
MEMOKEY 100C
MEMOKEY 100C
Default codes ......................................................................................................4
Total reset all codes ...........................................................................................5
Set up user code length .....................................................................................6
Add or edit user codes ......................................................................................7
Delete user codes ...............................................................................................8
Change Master codes ........................................................................................9
Enable user own code change ....................................................................... 10
Change free access code ............................................................................... 11
Set indoor pushbuttons ................................................................................... 12
Set electrical device activation timings ......................................................... 13
Set wildcard output ......................................................................................... 14
Reset MASTER code (if previous code forgotten) ......................................... 15
Troubleshooting table ..................................................................................... 16
PROGRAMMING MANUAL
USER MANUAL
Introduction ....................................................................................................... 17
Keyboard function ............................................................................................. 18
Controls ............................................................................................................. 19
Entry system operation ..................................................................................... 20
Video entry system operation ........................................................................... 21
Index
Index
Cod. 94908IFc V05/07

Pag 4
SISTEMAS
MEMOKEY 100C
MEMOKEY 100C
ACTIVATE AUXILIARY DEVICE (if present)
OPEN DOOR AND ACTIVATE AUXILIARY DEVICE
Default codes
For their use, codes are stored in the memory in the following sequence:
POSITION - CODE -ACTION
POSITION: Number assigned to each code in memory (del 00 al 99)
CODE: Number to enter through keypad to carry out the indicated action.
ACTION: What happens after code is entered correctly.
So that the system is up and running, with no need to set any codes, it leaves the factory with
three pre-programmed codes, as shown in the table:
(*) These codes are indicated by a label on the back of the keypad module.
NOTES:
99
99
9Preset codes are exclusive to each set of equipment, so only you will know them.
However, you can change them if you wish.
99
99
9Initially, user codes have 4 digits. For enhanced security, they may be set to 5 or
6 digits length. In this case, the preset codes will no longer be valid.
CODE ACTION
CODE 1 (*) OPEN DOOR
CODE 2 (*)
CODE 3 (*)
POSITION
00
01
02

Pag 5
SISTEMAS
MEMOKEY 100C
MEMOKEY 100C
Total reset - all codes
This operation is useful to ensure that any codes previously stored in the system are
deleted.
The operation should be carried out as a first step before starting to program the users.
The sequence is as follows:
2. Key in “A 9 “.
beep-beep
1480
A9
1. Enter PROGRAMMING mode
Key in the Master code, 1480 by default, although
this may be changed if you wish, as explained in
this manual.
beeeeep
3. Key in “B“.
B
NOTE:
4. Wait 3 seconds for memory to delete.
A “long beep” is heard.
beep
5. Exit PROGRAMMING mode
Key in “A A” to exit programming.
The system also exits this mode automatically after
20 seconds inactivity. beep-beep
A A
99
99
9Reset is an irreversible operation, so the codes stored previously cannot be
recovered.

Pag 6
SISTEMAS
MEMOKEY 100C
MEMOKEY 100C
NOTES:
99
99
9If user code length is changed after programming to a higher number of digits,
the existing codes will have extra zeros appended at the end to adapt to the new
length. This will also affect the MASTER Code and the Free Access Code.
99
99
9If user code length is changed after programming to a lower number of digits,
existing codes will have their final digits truncated.
Set user codes length
Initially, user codes have 4 digits, including the MASTER code.
For enhanced security, they may be changed to 5 or 6 digits, or 3 digits for greater ease.
(See NOTES below).
The steps are as follows:
2. Key in “ A 4”.
3. Indicate the new length (3, 4, 5 or 6).
4. Key in “ A A” to exit PROGRAMMING
System also exits programming mode
automatically after 20 seconds inactivity.
beep-beep
1480
A 4
3, 4, 5 or 6
beep-beep
A A
beeeep
1. Enter PROGRAMMING mode
Key in the Master code, 1480 by default, although
this can be changed if you wish, as shown in this
manual.

Pag 7
SISTEMAS
MEMOKEY 100C
MEMOKEY 100C
Add or edit user codes
Codes are stored in memory in this order: position - code - action, as follows:
NOTES:
99
99
9If the position to be set is already taken up, the new code cancels the previous
one. This is also valid for the factory preset codes, in positions 00, 01 and 02.
99
99
9It is very important to make a list of the codes with their position and action.
2. Key in the position.
This can be any number from 00 to 99.
See NOTE below.
beep-beep
1480
00...99
1. Enter PROGRAMMING mode
Key in the Master code, 1480 by default, although
this can be changed if you wish, as shown in this
manual.
3. Key in the new code
Number of digits must coincide with digit number
length set in the system.
CCCC
4. Key in the associated action.
1: Door will open.
2: Auxiliary device activates if present.
3: Door opens and auxiliary device activates
simultaneously. 1, 2 or 3
beeeeep
5. Exit PROGRAMMING mode
If you want to enter more codes go straight to step
2, if not simply key in “AA” to exit programming
mode.
System also exits programming mode
automatically after 20 seconds inactivity.
beep-beep
A A

Pag 8
SISTEMAS
MEMOKEY 100C
MEMOKEY 100C
Delete user codes
You may want to cancel a given user code. To do so, proceed as follows:
NOTES:
99
99
9A code can only be erased if you know the associated position, which is why we
again emphasise the importance of making a list of all codes and their position
and action programmed in the system.
99
99
9The code deletion action is irreversible, so once they are erased they cannot be
retrieved.
2. Key in position of code to be erased.
See NOTE below.
beep-beep
1480
00...99
1. Enter PROGRAMMING mode
Key in the Master code, 1480 by default, although
this may be changed if you wish, as shown in this
manual.
3. Key in “B “
Bbeeeep
4. Exit PROGRAMMING mode
If you want to remove more codes go straight to
step 2, otherwise key in “AA” to exit programming
mode.
System also exits program mode automatically
after 20 seconds inactivity.
beep-beep
A A

Pag 9
SISTEMAS
MEMOKEY 100C
MEMOKEY 100C
NOTE:
99
99
9If you forget the Master code, it can be replaced by the original 1480, as explained
in this manual.
Change Master Code
The Master Code is needed to enter programming mode. The equipment leaves the
factory with a default Master Code. It can be changed as follows.
2. Key in “A 0 “
See NOTE below
beep-beep
1480
A 0
1. Enter PROGRAMMING mode
Key in the default Master code, 1480
3. Key in new Master Code
The number of digits in the new code must
coincide with the number length set in the system.
MMMM beeeep
4. Exit PROGRAMMING mode
Key in “AA” to exit program mode.
System also exits programming mode
automatically after 20 seconds inactivity. beep-beep
A A

Pag 10
SISTEMAS
MEMOKEY 100C
MEMOKEY 100C
Enable user own code change
It is possible to allow the users to change the access code assigned to them for another
personal code. To do this the feature must be enabled.
2. Key in “A 7 “
beep-beep
1480
A 7
3. Key in “1” to enable permit or
Key in “0” to disable it.
1 or 0 beeeep
4. Exit PROGRAMMING mode
beep-beep
A A
1. Enter PROGRAMMING mode
Key in the Master code, 1480 by default, although
this may be changed if you wish, as shown in this
manual.
NOTE:
99
99
9Instructions for users to set their own code are given in the User Manual.
Key in “AA” to exit programming mode. System
exits programming mode automatically after 20
seconds inactivity.
Here is how to do it:
Other manuals for Memokey 100C
1
Table of contents
Languages:
Other Fermax Security System manuals
Popular Security System manuals by other brands

EDM
EDM Solution 6+6 Wireless-AE installation manual

Highway Safety Group
Highway Safety Group EA401 user manual

Siren
Siren LED GSM operating manual

Detection Systems
Detection Systems 7090i Installation and programming manual

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 instructions

Siemens
Siemens FDM273 manual