6.2 Mounting motor
Requirement
–Select accessories è www.festo.com/catalogue.
1. Degrease and dry the motor shaft.
2. Mount motor on the driven mechanical system.
Instruction manual for drive unit, gear unit and mounting kit
è www.festo.com/sp.
7 Installation
WARNING
Risk of injury due to electric shock.
• Switch off power supply prior to assembly and installation work; ensure that it
is off and secure it against being switched back on.
Cancelling the enable signal is not sufficient.
WARNING
Risk of injury due to electric shock.
High voltage potential can injure people when the motor plug is disconnected.
• Use appropriate measures to ensure that the motor plug cannot be discon-
nected.
7.1 Connect lines
Requirement
–Select accessories è www.festo.com/catalogue.
–Observe permissible cable length and conductor cross section
è www.festo.com/catalogue.
–Use screened cables.
1. Plug the cables into the appropriate plugs.
2. Connect the cables to the servo drive.
Instructions for servo drive and cables è www.festo.com/sp.
Plug, 4-pin, pins Pin Function Description
1 U Motor phase U
2 V Motor phase V
3 W Motor phase W
4 PE Protective earthing
Tab. 3: Plug for motor
Plug, 2-pin, pins Pin Function Description
1 BR+ Holding brake control:
–24 V DC: open (vented)
–0 V DC: closed (retracted)
2 BR– Reference potential 0 V
Tab. 4: Plug for holding brake
The adapter NEFM-REG6-K-0.5-B-R3G8 must be used with the servo motor with
multi-turn absolute encoder EMMB-AS-...-S30M è www.festo.com/sp.
Plug, 6-pin Pin Function Description
1 VCC Supply voltage 4.75 … 5.25 V DC
2 GND Earth 0 V
3 – Single-turn (S): not connected
BAT+ Multi-turn (M): supply voltage for battery
4 – Single-turn (S): not connected
BAT– Multi-turn (M): battery earth
5 SD+ Data line
6 SD–
Tab. 5: Plug for absolute encoder, single-turn/multi-turn, Nikon A format
8Commissioning
WARNING
Risk of injury due to unexpected movement of components.
• When releasing the holding brake, secure the driven mechanical system to
prevent unintended movement.
•Deenergise the motor before releasing the holding brake manually.
• Before setting the enable signal, protect the traversing range of the driven
mechanical system from access.
High voltage loss in the motor cable can result in the permissible operating
voltage of the holding brake being undershot.
• Observe permissible cable length and conductor cross section
è www.festo.com/catalogue.
8.1 Performing commissioning
Commissioning of the drive system may only be carried out with the confirmation
of conformity in accordance with EN 61800.
1. Commission the motor in combination with a suitable servo drive.
Instructions for servo drive è www.festo.com/sp.
2. Check function and holding torque of the holding brake.
For the grinding-in process of the brake system, briefly close the holding
brake at low speed, e.g. 3 s at 100 rpm.
9 Operation
WARNING
Risk of injury due to unexpected movement of components.
Body parts in the movement range of the piston rod can be crushed or severed.
• Protect the positioning range from unwanted intervention.
•Keep foreign objects out of the positioning range.
WARNING
Danger of burns from hot housing surfaces.
Metallic housing parts can reach high temperatures during operation.
Contact with metal housing parts can cause burn injuries.
•Do not touch metallic housing parts.
• After the power supply is switched off, let the device cool down to room
temperature.
Axial and radial forces on the motor shaft.
Excessive axial and radial forces on the motor shaft can damage the motor.
• Comply with maximum permissible shaft loads è www.festo.com/catalogue.
•Check the function and holding torque of the holding brake at regular inter-
vals.
If the holding torque is reduced, close the holding brake briefly at low speed,
e.g. 3 s at 100 rpm.
10 Maintenance
WARNING
Risk of injury due to electric shock.
• Switch off power supply prior to assembly and installation work; ensure that it
is off and secure it against being switched back on.
Cancelling the enable signal is not sufficient.
WARNING
Risk of injury due to unexpected movement of components.
• Bring moving parts of the connected mechanical system into a secure position
(e.g. for vertical installation, move the slide into the lower end position).
•Only then should you disconnect the motor from the mechanical system.
WARNING
Danger of burns from hot housing surfaces.
Metallic housing parts can reach high temperatures during operation.
Contact with metal housing parts can cause burn injuries.
•Do not touch metallic housing parts.
• After the power supply is switched off, let the device cool down to room
temperature.
10.1 Cleaning
Before cleaning, the product must be cooled down to below 40°C.
Clean the outside of the product with a soft cloth as required. Cleaning agents
include all non-abrasive media.
11 Malfunctions
WARNING
Risk of injury due to electric shock.
• Switch off power supply prior to assembly and installation work; ensure that it
is off and secure it against being switched back on.
Cancelling the enable signal is not sufficient.
WARNING
Risk of injury due to unexpected movement of components.
• Bring moving parts of the connected mechanical system into a secure position
(e.g. for vertical installation, move the slide into the lower end position).
•Only then should you disconnect the motor from the mechanical system.
WARNING
Danger of burns from hot housing surfaces.
Metallic housing parts can reach high temperatures during operation.
Contact with metal housing parts can cause burn injuries.
•Do not touch metallic housing parts.
• After the power supply is switched off, let the device cool down to room
temperature.