HP-6 Recessed 1" T-Bar Mitered Corner Installation Instructions
Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com
© 2017 FINELITE, INC. ALL RIGHTS RESERVED. Form 98370 V2. 04/17
Note: All power connections to be installed to local/national codes
by a Certified Electrician. 1
Protected by one or more US Patents: 8915613; D702,391; D702,390; D700,732; D727,554 S; D727,550 S, D727,551 S
Install starter luminaire on to T-Bar. Install T-Bar bracket onto luminaire. Secure with #8-18 x 1/4" screws (provided). Secure
luminaire to structure using tie-wire (by others), as per code.
Starter
Secure to Structure
(by others)
T-Bar Bracket
#8-18 x 1/4" Screws (provided)
Starter
Remove diffusers and set aside to prevent it from getting dirty
or damaged. NOTE: If part of a longer run, diffuser will be
reinstalled back into original luminaire section as lengths vary.
0 - 10V
Dimming
Scan QR code for
helpful video(s)
Starter
Diffuser
Step 1 Step 2 Step 3
Run power cables through conduit plate and jam nut. Make electrical
connections. Secure conduit onto conduit plate with jam nut, and
reinstall conduit plate carefully not to damage any wiring.
Remove conduit plate from luminaire. NOTE: Purple
and gray wires are for Low Voltage Control.
Attach optional splice box to conduit plate by hooking onto
splice box bracket. Insert wires through feed hole.
Run power cable through knock-out. Make electrical connection.
Secure conduit on to splice box with jam nut and close conduit plate.
Conduit Plate
Wires
Conduit
Conduit Plate
Jam Nut
Wires
Splice Box
Splice Box
Bracket
Jam Nut
Conduit Plate
Step 4 Step 5
OPTIONAL SPLICE BOX OPTIONAL SPLICE BOX
Screws
Conduit Plate