FingerTec AdapTec Plus Assembly instructions

Installer Guide

2
AdapTec Plus combines power supply and door access controller features
in a compact metal casing for an encrypted and secure I/O function, en-
hancing door access control functionalities and easing installation proc-
esses. The AdapTec Plus is an exceptional FingerTec accessory in a small
package!
UNDERSTANDING ADAPTEC PLUS FUNCTIONS
Enhanced Security with Encrypted Signals
It supports FingerTec encrypted 26-bit Wiegand communication output;
providing enhanced security level for extra protection.
Power Up Terminals & Door Lock Systems
A single AdapTec Plus can provide power simultaneously to a maximum 2
units of FingerTec terminals and 2 sets of door lock accessories such as EM
Lock and drop bolt in one single system installation.
Prolonged Life Span of Hardware
With data encryption, the life span of the terminals could be prolonged
without the risk of short circuiting when using AdapTec Plus.
Control IN/OUT Terminals At An Entrance
AdapTec Plus is a perfect choice for an IN/OUT installation, where a door
is controlled both, at the entrance and the exit.
Support Rechargeable Backup Battery
Connects well to any 12V rechargeable backup battery, providing power
to ensure protection of access during any events of power failure.
Adaptability to Enhanced Security

3
Emergency Alerts with Siren
Compatible with an NC siren type with a maximum of 0.5A load for emer-
gency event e.g if the terminal is being illegally dismantled.
Seamless Integration with FingerTec Terminals
Mix and match the FingerTec terminals via AdapTec Plus for a cost effec-
tive access control system suitable for small and medium sized offices.
Choose a DIY Metal Casing for Cleaner Installation
Store an AdapTec Plus and a backup battery in an exclusive FingerTec DIY
metal casing, providing a cleaner installation.
SPECIFICATIONS
MODEL AdapTec Plus
PRODUCT DIMENSION (L X W X H), mm 198 x 45 X 131
WEIGHT 1.1 kg
CPU 8 MHz 16-bit microprocessor
POWER INPUT AC 110 ~ 240V (universal input)
POWER OUTPUT DC12V 3A - Supports up to:
• 2 x FingerTec access control terminals
• 2 x electrical energized locks
BACKUP POWER SYSTEM UPS or DC 12V rechargeable backup battery
INPUT SIGNAL FingerTec encrypted Wiegand signal
OUTPUT SIGNAL 2 x FORM C Relay
• 1 x 0.5A siren (max)
• 1 x DC12V 3A EM output (max)
DOOR LOCK • Electromagnetic locks
• Door strike
• Drop bolt/Dead bolt
OPERATING TEMPERATURE 0°C to 55°C
HUMIDITY 10% to 90% RH (non-condensing)

4
1 2 3
12
32
1
UNDERSTANDING THE DESIGN
AdapTec Plus consists of 2 main modules and a timer:
1Power supply/power input module
2Access control/power output module
3Door lock timer
Power supply/power input module
1This portion is to be connected to power source with AC110~240V. AC current will
be supplied into this side and a DC 12V 3A current will be generated as output.
2These two cables, -V and +V are default and are connected to the inner part of
AdapTec. Please do not remove or change these cables.
Access control/power output module
1These cables connect to a DC12V rechargeable backup battery. During a power failure,
the battery will power up the AdapTec Plus.

5
This is a Door Lock Timer
Lengthen timing
Shorten timing
2These are the power outputs from AdapTec. Refer to the wiring diagrams in page 3, for
details.
3Power LED – a lit LED indicates power supply/power input module is working.
EM lock LED– a lit LED indicates that the AdapTec Plus is working to power up door
lock system.
Door lock timer
Users can adjust the timing for the EM Lock and Drop Bolt to close after opening using
the door lock timer. Turn the timer using a screwdriver; turning clockwise will lengthen
the time, turning anti-clockwise will shorten the time.
Note: AdapTec Plus can be connected to other devices which have the same power con-
AdapTec with other FingerTec models.

6
L N E -V
Power Supply/Power Input Module
AC110~240V
L - Live
N - Neutral
E - Earth
R B G
RRed
BBlue
GGreen
DC 12V
Rechargeable
Backup
Battery
AdapTec Plus
Access Control/Power Output Module
To Battery Tamper Siren EM Output Siren Door Wiegand
Switch Output 12V Voltage Accept Exit Input
- + Input 12V 0V GND WD0 WD1
Connection
Points
GND
PWR
WIRING DIAGRAMS
AC900
FUNCTION • Time Attendance Only
STEP 1 • Connection Points
STEP 2 • Connect AdapTec Plus to a Power Source
STEP 3 • Turn on the power to use FingerTec AC900 for time attendance
only.

7
L N E -V +V
Power Supply/Power Input Module
AC110~240V
L - Live
N - Neutral
E - Earth
R B G
RRed
BBlue
GGreen
AdapTec Plus
Access Control/Power Output Module
To Battery Tamper Siren EM Output Siren Door Wiegand
Switch Output 12V Voltage Accept Exit Input
- + Input 12V 0V GND WD0 WD1
Connection
Points
GND
PWR GND
WD0
WD1
DC 12V
Rechargeable
Backup
Battery
Connection
Points
Release
Button
EM +
Lock -
Emergency 2
Break
Glass (NC) 3
ON-OFF C
Key Switch
(NC) D
WIRING DIAGRAMS
AC900
FUNCTION • Access Control Only or Time Attendance
& Door Access
STEP 1 • Connection Points
STEP 2 • Connect AdapTec Plus to a Power Source
STEP 3 • Turn on the power to use FingerTec AC900 for door access con-
trol only or for time attendance and door access control simultaneously

8
RRed
BBlue
GGreen
L N E -V +V
Power Supply/Power Input Module
AC110~240V
L - Live
N - Neutral
E - Earth
R B G
DC 12V
Rechargeable
Backup
Battery
AdapTec Plus
Access Control/Power Output Module
To Battery Tamper Siren EM Output Siren Door Wiegand
Switch Output 12V Voltage Accept Exit Input
- + Input 12V 0V GND WD0 WD1
Connection
Points
GND
+12V
WIRING DIAGRAMS
R2, i-Kiosk100, i-Kiosk100 Plus, Q2i, Kadex
and m-Kadex
FUNCTION • Time Attendance Only
STEP 1 • Connection Points
STEP 2 • Connect AdapTec Plus to a Power Source
STEP 3 • Now you can turn on the power to use the system for time at-
tendance only.

9
RRed
BBlue
GGreen
L N E -V +V
Power Supply/Power Input Module
AC110~240V
L - Live
N - Neutral
E - Earth
R B G
AdapTec Plus
Access Control/Power Output Module
To Battery Tamper Siren EM Output Siren Door Wiegand
Switch Output 12V Voltage Accept Exit Input
- + Input 12V 0V GND WD0 WD1
Connection
Points
GND
+12V GND
WD0
WD1
DC 12V
Rechargeable
Backup
Battery
Connection
Points
Release
Button
EM +
Lock -
Emergency 2
Break
Glass (NC) 3
ON-OFF C
Key Switch
(NC) D
WIRING DIAGRAMS
R2, i-Kiosk100, i-Kiosk100 Plus, Q2i, Kadex
and m-Kadex
FUNCTION • Access Control Only or Time Attendance
& Door Access
STEP 1 • Connection Points
STEP 2 • Connect AdapTec Plus to a Power Source
STEP 3 • Turn on the power to use the model for door access control
only or for time attendance and door access control simultaneously.

10
L N E -V +V
Power Supply/Power Input Module
AC110~240V
L - Live
N - Neutral
E - Earth
R B G
RRed
BBlue
GGreen
DC 12V
Rechargeable
Backup
Battery
AdapTec Plus
Access Control/Power Output Module
To Battery Tamper Siren EM Output Siren Door Wiegand
Switch Output 12V Voltage Accept Exit Input
- + Input 12V 0V GND WD0 WD1
Connection
Points
GND
+12V
WIRING DIAGRAMS
Face ID 2
FUNCTION • Time Attendance Only
STEP 1 • Connection points
STEP 2 • Connect AdapTec Plus to a power source
STEP 3 • Turn on the power to use FingerTec Face ID 2 for time attend-
ance.

11
L N E -V +V
Power Supply/Power Input Module
AC110~240V
L - Live
N - Neutral
E - Earth
R B G
RRed
BBlue
GGreen
AdapTec Plus
Access Control/Power Output Module
To Battery Tamper Siren EM Output Siren Door Wiegand
Switch Output 12V Voltage Accept Exit Input
- + Input 12V 0V GND WD0 WD1
DC 12V
Rechargeable
Backup
Battery
Connection
Points
WD0
WD1
SGND
GND
+12V
Release
Button
EM +
Lock -
Emergency 2
Break
Glass (NC) 3
ON-OFF C
Key Switch
(NC) D
WIRING DIAGRAMS
Face ID 2
FUNCTION • Access Control Only or Time Attendance
& Door Access
STEP 1 • Connection points
STEP 2 • Connect AdapTec Plus to a power source
STEP 3 • Turn on the power to use FingerTec Face ID 2 for door access
control only or for time attendance and door access control simultane-
ously.

12
AdapTec Plus
Access Control/Power Output Module
To Battery Tamper Siren EM Output Siren Door Wiegand
Switch Output 12V Voltage Accept Exit Input
- + Input 12V 0V GND WD0 WD1
DC 12V
Rechargeable
Backup
Battery
Connection
Points
ALM+
ALM-
GND
+12V
Release
Button
Alarm
Siren
+ _
CONNECTING ADAPTEC PLUS TO AN
ALARM SIREN
For all FingerTec door access control models, there
is a security button behind the terminal. During nor-
mal operation, the security button is compressed and
once the terminal is dismantled, the button will be
released and “System broken” message will appear
onscreen.
During the release of the button, the terminal will output an alarm sig-
nal. Nonetheless, no alarm sound will be emitted if the terminal is not
equipped with a preinstalled siren.
To use the siren feature, we recommend you to install an additional alarm
siren and connect it to the FingerTec terminals.
Benefits of using AdapTec plus with Alarm Siren
We recommend you to install a terminal along with an AdapTec Plus if
you plan to use the alarm siren. In the AdapTec Plus, an additional port
is readily built to receive the alarm signal from the FingerTec terminals.
the AdapTec Plus has an output of DC12V and it is suitable to use with
an alarm siren that has the same power input. You do not need to source
and additional DC12V power supply for this purpose. Furthermore, the
AdapTec Plus provides a “Siren Accept” button where you can press the
button to deactivate alarm siren when required.
FUNCTION • R2, Kadex and m-Kadex
Connect the terminal, alarm siren and AdapTec Plus as illustrated below.
STEP 1 • Wiring Diagram
Remark:
Set Auto Alarm in terminal to N.
Menu > Options > Sys Opt > Adv Opt > Auto Alarm > N.

13
AdapTec Plus
Access Control/Power Output Module
To Battery Tamper Siren EM Output Siren Door Wiegand
Switch Output 12V Voltage Accept Exit Input
- + Input 12V 0V GND WD0 WD1
DC 12V
Rechargeable
Backup
Battery Connection
Points
GND
PWR
AL+
AL_
Release
Button
Alam
Siren
+ _
AdapTec Plus
Access Control/Power Output Module
To Battery Tamper Siren EM Output Siren Door Wiegand
Switch Output 12V Voltage Accept Exit Input
- + Input 12V 0V GND WD0 WD1
DC 12V
Rechargeable
Backup
Battery
Connection
Points
Release
Button
Alam
Siren
+ _
COM2
NC2
GND
+12V
FUNCTION • AC900
For AC900, you will need to connect AC900, alarm siren and AdapTec Plus
as below.
FUNCTION • Face ID 2, i-Kiosk 100, Q2i, i-Kiosk 100 Plus
For Face ID 2, you will need to connect to alarm siren and AdapTec Plus
as below.
Reminder to deactivate alarm siren:
1. You can deactivate the alarm siren by pressing the push button that is connected to Siren
Accept in the AdapTec Plus. This action will turn off the alarm siren function in AdapTec
plus. However, you must restart the AdapTec Plus to turn on the alarm siren function
again. The alarm siren will not take effect in the future if you do not restart the AdapTec
Plus.
2. You can do it from the terminal via Menu > Turn Off Alarm to turn off the alarm siren. You
do not need to restart the AdapTec Plus. The alarm siren will return to standby mode after
you perform the steps at the reader. (Recommended)

14
WALLWALL
WOODEN DOOR
OUTDOOR
4 feet / 1.2 meter
(recommended)
1
Screws
Back Steel
Plate
2
CEILING
INDOOR
Silver
Nut
Steel
Bar
Allen Key
Screw
Wooden Doorframe
CEILING
INDOOR
Screws
Magnet
Doorframe
Aluminum
Plate
Allen
Key
Screws
3
1
2
2
1
2
3
1
2
3
UNDERSTANDING ADAPTEC
INSTALLATION FOR • Wooden Door
The diagrams below only highlight the use of an EM lock during installation.You may
opt to use a dropbolt/deadbolt/door strike instead. Please consult a qualified techni-
cian/installer before proceeding with the installation.
1To install FingerTec
AC900/R2 on a wall, drill
5 holes as shown. 4 small
holes are for the screws
and the bigger hole is for
the network cable.
2Tighten the 4 screws to
fix the Back Plate on the
wall.
3Install the keyswitch as
per instructions given in
the box. The keyswitch is
an override key in case of
a system failure or break-
down.
1Drill 3 holes on the
wooden door.
2Place the Steel Bar on
the door. Insert the Silver
Nut on one side and the
Allen Key Screw on the
other side. Tighten the
screw to lock the Steel
Bar onto its position.
1Drill 4 holes on the
wooden frame. Tighten
the 4 screws to fix the
Aluminum Plate prop-
erly on the doorframe.
2Use the Allen Key to
tighten the 2 screws at
the bottom of the Mag-
net. The Magnet will
stick to the Aluminum
Plate when the screws
are tightened .
3Use the Allen Key to
tighten the other 2
screws on the sides of
the Magnet.

15
4
5
6
Emergency
Break Glass
Push Button
CEILING
ABOVE CEILING
Hub / Switch
PC
OUTDOOR INDOOR NETWORKING
FingerTec®
Series
AdapTec AC
ON-OFF
Keyswitch
To FingerTec® Series
AC110/240V
Power
Input
12V Rechargeable
battery
CEILING
ABOVE CEILING
BELOW
CEILING
Computer/
Network Hub/
Network Switch
2
To FingerTec®Series
3
AC110/240V
Power
Input
1 1
2
3
4 feet / 1.2 meter
(recommended)
CEILING
INDOOR
Emergency
Break Glass
Push Button
4
5
6
112V 3A DC Power
Output
2AdapTec Plus
Note: Refer to AdapTec user
guide for wiring diagrams.
312V Rechargeable Bat-
tery
Note: It is recommended to
place 1, 2and 3out of
sight, either above a ceiling or
wall-mounted.
Emergency Break Glass
and Push Button should
be installed indoors. These
two items are for the user to
open the door from inside.
Note: Please conceal the wir-
ing for a cleaner installation.
OVERVIEW OF THE
WHOLE SYSTEM
INSTALLATION

16
CEILING
CEILING
INDOOR
Screws
Magnet
Doorframe
Aluminum
Plate
Allen
Key
Screws
1
2
3
GLASS DOOR
WALLWALL
OUTDOOR
4 feet / 1.2 meter
(recommended)
Screws
Back Steel
Plate
1
2
3
OUTDOOR
U-Bracket
Philip Screw
Steel
Bar
Allen Key
Screws
Allen Key
Screws
Glass Doorframe
1
12
1
2
3
UNDERSTANDING ADAPTEC
INSTALLATION FOR • Glass Door
The diagrams below only highlight the use of an EM lock during installation.You may
opt to use a dropbolt/deadbolt/door strike instead. Please consult a qualified techni-
cian/installer before proceeding with the installation.
1To install a FingerTec
model on the wall, drill
5 holes as shown. 4 small
holes are for the screws
and the bigger hole is
for the network cable.
2Tighten the 4 screws to
fix the Back Plate on the
wall.
3Install the keyswitch as
per instructions given in
the box. The keyswitch
is an override key in case
of a system failure or
breakdown.
1Lodge the U-Bracket
into the upper edge of
the glass doorframe.
Tighten the 4 Allen
Screws to hold the U-
Bracket into position.
2Place the Steel Bar on
the side of the U-Brack-
et. Tighten the Philip
Screw to lock the Steel
Bar onto position.
1Drill 4 holes on the door-
frame. Tighten the 4
screws to fix the Alumi-
num Plate properly on
the doorframe.
2Use the Allen Key to
tighten the 2 screws at
the bottom of the Mag-
net. The Magnet will
stick to the Aluminum
Plate when the screws
are tightened.
3Use the Allen Key to
tighten the other 2
screws on the sides of
the Magnet.

17
5
6
CEILING
ABOVE CEILING
BELOW
CEILING
Computer/
Network Hub/
Network Switch
2
To FingerTec®Series
3
AC110/240V
Power
Input
1 1
2
3
4 feet / 1.2 meter
(recommended)
CEILING
Emergency
Break Glass
Push Button
INDOOR
Emergency
Break Glass
Push Button
CEILING
ABOVE CEILING
Hub / Switch
PC
OUTDOOR INDOOR NETWORKING
FingerTec®
Series
AdapTec AC
ON-OFF
Keyswitch
To FingerTec® Series 12V Rechargeable
battery
AC110/240V
Power
Input
4
5
6
112V 3A DC Power
Output
2AdapTec Plus
Note: Refer to AdapTec
user guide for wiring
diagrams.
312V Rechargeable
Battery
Note: It is recommended to
place 1, 2and 3out of
sight, either above a ceiling or
wall-mounted.
Emergency Break Glass
and Push Button should
be installed indoors.
These two items are for
the user to open the
door from inside.
Note: Please conceal the wir-
ing for a cleaner installation.
OVERVIEW OF THE
WHOLE SYSTEM
INSTALLATION

D
O
O
R
L
O
C
K
T
I
M
E
R
RFID Key Chain
HID Card / MiFare Card /
RFID Card
D
O
O
R
L
O
C
K
T
I
M
E
R
AdapTec AC
AdapTecTA
Emergency Break Glass
EM 600 / EM 1200
Description
Release Button Contactless
Release Button
Alarm Siren With
Strobe Light
5V/ 12V Mini UPS
Press
EMERGENEGY
DOOR RELEASE
BREAK GLASS
PRESS HERE
EXIT
ON
OFF
FINGERTEC EXCLUSIVE ACCESSORIES
For more accessories go to accessory.fingertec.com.

OTHER RESOURCES
Information About FingerTec
TO LEARN ABOUT GO TO?
Company and the products www.fingertec.com
The latest updates Facebook Fan Page: FingerTec Worldwide
Twitter: FingerTec Worldwide
To subscribe for FingerTec Newsletter:
www.fingertec.com/subscribe-R/newsletter.html
Technical Tips and Latest user.fingertec.com
Product Updates and
Upgrades
Email [email protected] (Sales)
[email protected] (Technical)
Register for Warranty www.fingertec.com/GPW/warranty.htm
FingerTec Accessory accessory.fingertec.com

INPUT : AC 110 ~ 240V
OUTPUT : DC 12V 3A
MOUNTING AN ADAPTEC PLUS
ONTO A WALL
1
2
4
After removing the piece, you will have
one L-shape piece and 2 screws.
3
Remove the L-shape piece from the AdapTec plus
Find an L-shape piece at the top right of an
AdapTec Plus. This piece is attached to the
AdapTec Plus with 2 screws.
Attach the L-shape to the AdapTec Plus
as shown and tighten the screws.
Open the cap, look for the part shown in
the diagram and you will see 2 holes.
www.fingertec.com
© 2011 FingerTec Worldwide Sdn. Bhd. All rights reserved. • Printed in Malaysia. 102011
Install the piece to the AdapTec Plus The other 2 holes at the bottom
Mount the AdapTec Plus on a wall
Identify a location to mount the
AdapTec Plus on a wall.
Fix the AdapTec Plus onto the wall
by tightening the screws into the 4
holes.
Other manuals for AdapTec Plus
1
Table of contents
Other FingerTec Security System manuals

FingerTec
FingerTec FaceID 3 User manual

FingerTec
FingerTec h2b User manual

FingerTec
FingerTec TA500 User manual

FingerTec
FingerTec TA100 DIY SERIES User manual

FingerTec
FingerTec TA700W User manual

FingerTec
FingerTec TA200 Plus User manual

FingerTec
FingerTec AC100C User manual

FingerTec
FingerTec m-Kadex User manual

FingerTec
FingerTec m-Kadex Operating and maintenance instructions

FingerTec
FingerTec TA100C User manual