Thank you for choosing IES5100-24FS L3 Managed Industrial Switch. This guide is designed to
familiarize you with the layout of the switch and describes how to deploy it in your network.
Mounting Bracket x2
Accessories
Console Cable x1 M3 Screw x8 Rubber Pad x4
IES5100-24FS
CLI
PWR1
PWR2 SFP+
SYS
100-240V
PWR
PWR1/PWR2
1 5 9 13 17 21
4 8 12 16 20 24
1
4 N L
IES5100-24FS
L N AC
DC
21 43
SFP+
1817 2019 2221 2423
21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423
COMBO COMBO

CLI
PWR1
PWR2 SFP+
SYS
100-240V
PWR
PWR1/PWR2
1 5 9 13 17 21
4 8 12 16 20 24
1
4 N L
IES5100-24FS
L N AC
DC
21 43
SFP+
1817 2019 2221 242321 43 65 87 109 1211 1413 1615 1817 2019 2221 2423
COMBO COMBO
CLI
PWR1
PWR2 SFP+
SYS
100-240V
PWR
PWR1/PWR2
1 5 9 13 17 21
4 8 12 16 20 24
1
4 N L
IES5100-24FS
L N AC
DC
21 43
SFP+
1817 2019 2221 2423
21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423
COMBO COMBO
2
Hardware Overview
Front Panel Ports
EN
Ports Description
Console
SFP+
RJ45/SFP Combo
SFP
An RJ45 console port for serial management
SFP+ ports for 10G connection
SFP port for 1G connection
One RJ45 port and one SFP port, with one port active at a time
Front Panel LEDs
ComboSFPConsole SFP+
Combo
SFP
SYS
PWR1/
PWR2
The system works well.Blinking
The system is being started up.On
O
On
On
O
O
Power is being supplied to power input.
Power is not being supplied to power input.
The port is connected to a device, but no data is
being transmitted through the port.
SFP+/SFP
/Combo Blinking The port is connected to a device and data is being
transmitted through the port.
The port is not connected or is not connected
properly.
LEDs State Description
The system is not working.

CLI
PWR1
PWR2 SFP+
SYS
100-240V
PWR
PWR1/PWR2
1 5 9 13 17 21
4 8 12 16 20 24
1
4 N L
IES5100-24FS
L N AC
DC
21 43
SFP+
1817 2019 2221 242321 43 65 87 109 1211 1413 1615 1817 2019 2221 2423
COMBO COMBO
3
EN
Front Panel
Installation Requirements
Before the installation, make sure that you have the following:
Screwdriver, static-proof wristband, bolt, Ethernet cable, other Ethernet terminal devices and
control terminal.
Standard-sized, 19" wide rack with a minimum of 1U height available.
Category 5e or higher RJ45 Ethernet cables and ber optical cable for connecting network devices.
Site Environment
Make sure that the temperature of the installation site is maintained at -40°C~85°C.
The installation site must be well ventilated. Ensure that there is adequate airow around the
switch.
The switch should be installed at least 1U (44.45mm) away from devices to its sides.
Be sure that the switch is level and stable to avoid any hazardous conditions.
Do not install the equipment in a dusty environment.
The installation site must be free from leaking or dripping water, heavy dew, and humidity.
Ensure the rack and working platforms are well earthed.
Power Input
Grounding point
Power Alarm Output
CLI
PWR1
PWR2 SFP+
SYS
1 5 9 13 17 21
4 8 12 16 20 24
1
4
SFP+
21 43 21 43 65 87 10
912
11 14
13 16
15 18
17 20
19 18
17

4
EN
Mounting the Switch
1. Attach the four rubber pads to the four corners on the switch bottom.
2. Place the switch on the desk.
1. Secure the mounting brackets to the two sides of the switch with supplied M3 screws.
Desk Mounting
NOTE: Do not put things weighing 4.5kg or over 4.5kg on the top of the switch.
100-240V
PWR
PWR1/PWR2
N L L N AC
DC
CLI
PWR1
PWR2 SFP+
SYS
1 5 9 13 17 21
4 8 12 16 20 24
1
4
21 43
SFP+
1817 2019 2221 2423
21 43 65 87 1091211 1413 1615 1817 2019 2221 2423
COMBO COMBO
IES5100-24FS
Rack Mounting
IES5100-24FS
100-240V
PWR
PWR1/PWR2
N L L N AC
DC
18 20
19 22
21 24
23 22
21 24
23
CLI
PWR1
PWR2 SFP+
SYS
1 5 9 13 17 21
4 8 12 16 20 24
1
4
CONSOLE
PWR1
PWR2
SYS
5 9 13 17 21 25
6 10 14 18 22 26
7 11 15 19 23 27
8 12 16 20 24 28
1
2
3
4
IES5100-24TF 21 43
SFP

5
EN
1. Connect one end of the grounding cable to a proper earth ground, such as the rack in which the
switch is mounted.
2. Secure the grounding lug to the grounding point on the switch front panel with the screw and
washers.
IES5100-24FS
100-240V
PWR
PWR1/PWR2
N L L N AC
DC
CLI
PWR1
PWR2 SFP+
SYS
1 5 9 13 17 21
4 8 12 16 20 24
1
4
SFP+
21 43 21 43 65 87 10
912
11 14
13 16
15 18
17 20
19 18
17 20
19 22
21 24
23 22
21 24
23
COMBO COMBO
2. Attach the switch to the rack using the screws and tighten them.
Grounding the Switch
IES5100-24FS
100-240V
PWR
PWR1/PWR2
N L L N AC
DC
21
24
SFP+
21 43 21 43 65 87 10
912
11 14
13 16
15 18
17 20
19 18
17 20
19 22
21 24
23 22
21 24
23
COMBO COMBO
CAUTION: The earth connection must not be removed unless all supply connections have
been disconnected.
65 87 109 1413 15
41211

6
EN
1. Insert the RJ45 connector into the RJ45 console port on the front panel of the switch.
2. Connect the DB9 female connector of the console cable to the serial port on the PC.
Connecting the Console Port
CLI
PWR1
PWR2 SFP+
SYS
1 5 9 13 17 21
4 8 12 16 20 24
1
4
SFP+
21 43 21 43 65 87 10
912
11 14
13 16
15 18
17 20
19 17
1. Plug the compatible SFP+ transceiver into the SFP+ port.
2. Connect a ber optic cable to the ber transceiver. Then connect the other end of the cable to the
other ber device.
Connecting the SFP+ Ports
100-240V
PWR
PWR1/PWR2
CLI
PWR1
PWR2 SFP+
SYS
1 5 9 13 17 21
4 8 12 16 20 24
1
4
SFP+
21 43 21 43 65 87 10
912
11 14
13 16
15 18
17 20
19 18
17 20
19 22
21 24
23 22
21 24
23
COMBO COMBO
1615 1817 2019 2221 2423

7
EN
IES5100-24FS
100-240V
PWR
PWR1/PWR2
N L L N AC
DC
18
17 20
19 22
21 24
23 22
21 24
23
IES5100-24FS
100-240V
PWR
PWR1/PWR2
N L L N AC
DC
Connecting the SFP Ports
100-240V
PWR
PWR1/
CLI
PWR1
PWR2 SFP+
SYS
1 5 9 13 17 21
4 8 12 16 20 24
1
4
SFP+
21 43 21 43 65 87 10
912
11 14
13 16
15 18
17 20
19 18
17 20
19 22
21 24
23 22
21 24
23
COMBO COMBO
1. Connect an Ethernet cable to the RJ45 port of a computer, printer, network storage, or other
network devices.
2. Connect the other end of the Ethernet cable to the RJ45 port of the switch.
1. Plug the compatible SFP transceiver into the SFP port.
2. Connect a ber optic cable to the ber transceiver. Then connect the other end of the cable to
another ber device.
Connecting the RJ45 Ports
IES5100-24FS
100-240V
PWR
PWR1/PWR2
N L L N AC
DC
CLI
PWR1
PWR2 SFP+
SYS
1 5 9 13 17 21
4 8 12 16 20 24
1
4
SFP+
21 43 21 43 65 87 10
912
11 14
13 16
15 18
17 20
19 18
17 20
19 22
21 24
23 22
21 24
23
COMBO COMBO
CLI
PWR1
PWR2 SFP+
SYS
1 5 9 13 17 21
4 8 12 16 20 24
1
4
21 43
SFP+
21 43 65 87 109 1211 13
2625 2827

8
EN
Connecting the Power
1. Press the orange button with your hand or a at-blade screwdriver.
The front panel of the switch indicates an AC/DC inlet power socket and consists of one terminal
block connector within 5 contacts. Please follow the steps below to insert the power wire.
IES5100-24FS
100-240V
PWR
PWR1/PWR2
N L L N AC
DC
100-240V
PWR
PWR1/PWR2
N L
IES5100-24FS
L N AC
DC
1817 2019 2221 2423
1413 1615 1817 2019 2221 2423
100-240V
PWR
PWR1/PWR2
N L
AC
DC
L N
2. Insert positive/negative AC/DC power wires into contacts 2 and 1 for PWR1 or 4 and 5 for PWR2,
then release the button.
Live line/Positive
Null line/Negative
Requiring good ground connection
NameNo. Description
L/+
N/-
1
2
3

9
EN
NOTE: The wire gauge for the terminal block should be in the range of 12-24 AWG.
1
V1- V1+
PWR1 PWR2
V2+ V2-
2345
Pin 1 / 5
Positive (+) Pin Negative (-) Pin
Pin 2 / 4
Conguring the Switch
Conguring the Switch Using the Console Port
Step 1: Connect a computer to the console port of the switch with the console cable.
Step 2: Start the terminal simulation software, such as HyperTerminal on the computer.
Step 3: Set the parameters of the HyperTerminal: Baud rate to 115200, Data bits to 8, Parity to None,
Stop bits to 1, and Flow control to None.

10
EN
x
Quick Connect
Protocol: Serial
Flow Control
DTR/DSR
RTS/CTS
XON/XOFF
Save sessionShow quick connect on startup
The port may be manually entered or selected from the list.
Open in a tab
Cancel
COM3
115200
8
None
1
Port:
Baud rate:
Data bits:
Parity:
Stop bits:
Name of pipe:
Connect
Step 4: After setting the parameters, click Connect to enter.
Conguring the Switch Using the Web-Based Interface
Step 1: Connect a computer to the Management port of the Switch using the network cable.
Step 2: Set the IP address of the computer to 192.168.1.x ("x" is any number from 2 to 254).
?
OK Cancel
General
IP address:
Subnet mask :
Default g a te w a y :
Yo u c an get IP settings assigneda u t omatically i f y o u r n e t w o r k
supports this capabilit y . Othe r wis e , y o u need to a s k y our net w o r k
administrator for thea ppropriate IP settings .
In te rn et Pr ot oc ol Ve rsi on 4 ( T CP /IPv4) Proper t ies
Use the foll owing IP address :
Obtainan IP addres s automatically
Preferred DNS server:
Alternate DNS server:
Validate settings upon exit Advanced...
. . . 21168192
0255
255255
. . .
. . .
. . .
. . .
ObtainDNS ser ver addr ess automatically
Use the foll owing DN S se r ve r addresses:

11
EN
Step 3: Open a browser, type http://192.168.1.1 and enter the default username and password,
admin/admin.
Step 4: Click Login to display the web-based conguration page.
admin
IE 8/9/10/11, Google Chrome, Firefox are supported
Login
Troubleshooting
Faults Related To Power And Cooling System
When the power switch is “ON” , check whether the fan works normally. If the fan does not work
well, check the fan.
The working temperature of the switch is from -40°C to 85°C. If the switch is too hot, check
whether the air outlet and air inlet are clean.
If the switch cannot be started and the PWR indicator is o, check the power.

12
EN
Download
Help Center
Contact Us
https://www.fs.com/products_support.html
https://www.fs.com/service/fs_support.html
https://www.fs.com/contact_us.html
Product Warranty
Online Resources
Return: If you want to return the item(s), information on how to return can be found at
https://www.fs.com/policies/day_return_policy.html
Warranty: IES5100-24FS switch enjoys a 5-year limited warranty against defects in
materials or workmanship. For more details about the warranty, please check at
https://www.fs.com/policies/warranty.html
5
FS ensures our customers that for any damage or faulty items due to our workmanship, we will oer a
free return within 30 days from the day you receive your goods. This excludes any custom-made items
or tailored solutions.
Faults Related To Port, Cable And Connection
If the port of the switch cannot be linked, check whether the cable is correctly connected and
whether the peer connection is normal.
If the power switch is “ON” , check the power source and the power cable.
If the console port does not work after the system is started up, check whether the console port is
set to a baud rate of 9600 bps, eight data bits, no sum check bit, one stop bit and no ow control.

13
Einführung
DE
Vielen Dank, dass Sie sich für den IES5100-24FS L3 Managed Industrial Switch entschieden haben.
Diese Anleitung soll Sie mit dem Aufbau des Switches vertraut machen und beschreibt, wie Sie ihn in I
hrem Netzwerk einsetzen.
Montagehalterung x2
Zubehör
Console-Kabel x1 M3-Schraube x8 Gummipad x4
IES5100-24FS
CLI
PWR1
PWR2 SFP+
SYS
100-240V
PWR
PWR1/PWR2
1 5 9 13 17 21
4 8 12 16 20 24
1
4 N L
IES5100-24FS
L N AC
DC
21 43
SFP+
1817 2019 2221 2423
21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423
COMBO COMBO

CLI
PWR1
PWR2 SFP+
SYS
100-240V
PWR
PWR1/PWR2
1 5 9 13 17 21
4 8 12 16 20 24
1
4 N L
IES5100-24FS
L N AC
DC
21 43
SFP+
1817 2019 2221 242321 43 65 87 109 1211 1413 1615 1817 2019 2221 2423
COMBO COMBO
CLI
PWR1
PWR2 SFP+
SYS
100-240V
PWR
PWR1/PWR2
1 5 9 13 17 21
4 8 12 16 20 24
1
4 N L
IES5100-24FS
L N AC
DC
21 43
SFP+
1817 2019 2221 2423
21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423
COMBO COMBO
14
Hardware-Übersicht
Ports an der Vorderseite
DE
Port Beschreibung
Console
SFP+
RJ45/SFP Combo
SFP
Ein RJ45-Console-Port für die serielle Verwaltung
SFP+-Ports für 10G-Verbindungen
SFP-Port für 1G-Verbindung
Ein RJ45-Port und ein SFP-Port, wobei jeweils ein Port aktiv ist
LEDs an der Vorderseite
ComboSFPConsole SFP+
Combo
SFP
SYS
PWR1/
PWR2
Das System funktioniert richtig.Blinkt
Das System wird hochgefahren.An
Aus
An
An
Aus
Aus
Der Netzeingang wird mit Strom versorgt.
Der Netzeingang wird nicht mit Strom versorgt.
Der Port ist mit einem Gerät verbunden, aber es
werden keine Daten über den Port übertragen.
SFP+/SFP
/Combo Blinkt Der Port ist mit einem Gerät verbunden und es
werden Daten über den Port übertragen.
Der Port ist nicht oder nicht richtig angeschlossen.
LED Status Beschreibung
Das System funktioniert nicht richtig.

CLI
PWR1
PWR2 SFP+
SYS
1 5 9 13 17 21
4 8 12 16 20 24
1
4
SFP+
21 43 21 43 65 87 10
912
11 14
13 16
15 18
17 20
19 18
17
CLI
PWR1
PWR2 SFP+
SYS
100-240V
PWR
PWR1/PWR2
1 5 9 13 17 21
4 8 12 16 20 24
1
4 N L
IES5100-24FS
L N AC
DC
21 43
SFP+
1817 2019 2221 242321 43 65 87 109 1211 1413 1615 1817 2019 2221 2423
COMBO COMBO
15
DE
Montage des Switches
Montage am Schreibtisch
Vorderseite
Installationsvoraussetzungen
Vergewissern Sie sich vor der Installation, dass Sie Folgendes haben:
Schraubendreher, statiksicheres Armband, Bolzen, Ethernet-Kabel, andere Ethernet-Endgeräte
und Steuerterminal.
Ein 19"-Rack in Standardgröße mit einer Mindesthöhe von 1 HE steht zur Verfügung.
RJ45-Ethernet-Kabel der Kategorie 5e oder höher und Glasfaserkabel für den Anschluss von
Netzwerkgeräten.
Umgebung des Aufstellungsortes:
Stellen Sie sicher, dass die Temperatur des Aufstellungsortes zwischen -40°C und 85°C liegt.
Der Installationsort muss gut belüftet sein. Stellen Sie sicher, dass um den Switch herum ein
ausreichender Luftstrom herrscht.
Der Switch sollte mindestens 1 HE (44,45 mm) von den Geräten an seinen Seiten entfernt
installiert werden.
Achten Sie darauf, dass der Switch waagerecht und stabil steht, um gefährliche Bedingungen zu
vermeiden.
Installieren Sie das Gerät nicht in einer staubigen Umgebung.
Der Installationsort muss frei von austretendem oder tropfendem Wasser, starkem Tau und
Feuchtigkeit sein.
Stellen Sie sicher, dass das Rack und die Arbeitsbühnen gut geerdet sind.
Stromeingang
Erdungspunkt
Strom-Alarmausgang

IES5100-24FS
100-240V
PWR
PWR1/PWR2
N L L N AC
DC
18 20
19 22
21 24
23 22
21 24
23
16
DE
1. Befestigen Sie die vier Gummipads an den vier Ecken der Unterseite des Switches.
2. Legen Sie den Switch auf den Schreibtisch.
1. Befestigen Sie die Montagehalterungen mit den mitgelieferten M3-Schrauben an den beiden Seiten
des Switches.
HINWEIS: Stellen Sie keine Gegenstände mit einem Gewicht von 4,5kg oder mehr auf die
Oberseite des Switches.
100-240V
PWR
PWR1/PWR2
N L L N AC
DC
CLI
PWR1
PWR2 SFP+
SYS
1 5 9 13 17 21
4 8 12 16 20 24
1
4
21 43
SFP+
1817 2019 2221 2423
21 43 65 87 1091211 1413 1615 1817 2019 2221 2423
COMBO COMBO
IES5100-24FS
Rack-Montage
CLI
PWR1
PWR2 SFP+
SYS
1 5 9 13 17 21
4 8 12 16 20 24
1
4
CONSOLE
PWR1
PWR2
SYS
5 9 13 17 21 25
6 10 14 18 22 26
7 11 15 19 23 27
8 12 16 20 24 28
1
2
3
4
IES5100-24TF 21 43
SFP

17
DE
1. Schließen Sie ein Ende des Erdungskabels an eine geeignete Erdung an, z. B. an das Rack, in dem
der Switch montiert ist.
2. Befestigen Sie die Erdungslasche mit der Schraube und den Unterlegscheiben am Erdungspunkt an
der Vorderseite des Switches.
IES5100-24FS
100-240V
PWR
PWR1/PWR2
N L L N AC
DC
CLI
PWR1
PWR2 SFP+
SYS
1 5 9 13 17 21
4 8 12 16 20 24
1
4
SFP+
21 43 21 43 65 87 10
912
11 14
13 16
15 18
17 20
19 18
17 20
19 22
21 24
23 22
21 24
23
COMBO COMBO
2. Befestigen Sie den Switch mit den Schrauben am Rack und ziehen Sie sie fest.
Erdung des Switches
IES5100-24FS
100-240V
PWR
PWR1/PWR2
N L L N AC
DC
21
24
SFP+
21 43 21 43 65 87 10
912
11 14
13 16
15 18
17 20
19 18
17 20
19 22
21 24
23 22
21 24
23
COMBO COMBO
ACHTUNG: Der Erdungsanschluss darf erst dann entfernt werden, wenn alle
Versorgungsanschlüsse getrennt wurden.
65 87 109 1413 15
41211

18
DE
1. Stecken Sie den RJ45-Stecker in den RJ45-Console-Port an der Vorderseite des Switches.
2. Verbinden Sie die DB9-Buchse des Console-Kabels mit dem seriellen Port des PCs.
Anschließen des Console-Ports
CLI
PWR1
PWR2 SFP+
SYS
1 5 9 13 17 21
4 8 12 16 20 24
1
4
SFP+
21 43 21 43 65 87 10
912
11 14
13 16
15 18
17 20
19 17
1. Stecken Sie den kompatiblen SFP+-Transceiver in den SFP+-Port.
2. Schließen Sie ein Glasfaserkabel an den Glasfasertransceiver an. Schließen Sie dann das andere
Ende des Kabels an das andere Glasfasergerät an.
Anschließen der SFP+-Ports
100-240V
PWR
PWR1/PWR2
CLI
PWR1
PWR2 SFP+
SYS
1 5 9 13 17 21
4 8 12 16 20 24
1
4
SFP+
21 43 21 43 65 87 10
912
11 14
13 16
15 18
17 20
19 18
17 20
19 22
21 24
23 22
21 24
23
COMBO COMBO
1615 1817 2019 2221 2423

19
DE
IES5100-24FS
100-240V
PWR
PWR1/PWR2
N L L N AC
DC
18
17 20
19 22
21 24
23 22
21 24
23
IES5100-24FS
100-240V
PWR
PWR1/PWR2
N L L N AC
DC
Anschließen der SFP-Ports
100-240V
PWR
PWR1/
CLI
PWR1
PWR2 SFP+
SYS
1 5 9 13 17 21
4 8 12 16 20 24
1
4
SFP+
21 43 21 43 65 87 10
912
11 14
13 16
15 18
17 20
19 18
17 20
19 22
21 24
23 22
21 24
23
COMBO COMBO
1. Schließen Sie ein Ethernet-Kabel an den RJ45-Port eines Computers, Druckers, Netzwerkspeichers
oder anderer Netzwerkgeräte an.
2. Schließen Sie das andere Ende des Ethernet-Kabels an den RJ45-Port des Switches an.
1. Stecken Sie den kompatiblen SFP-Transceiver in den SFP-Port.
2. Schließen Sie ein Glasfaserkabel an den Glasfasertransceiver an. Schließen Sie dann das andere
Ende des Kabels an ein anderes Glasfasergerät an.
Anschließen der RJ45-Ports
IES5100-24FS
100-240V
PWR
PWR1/PWR2
N L L N AC
DC
CLI
PWR1
PWR2 SFP+
SYS
1 5 9 13 17 21
4 8 12 16 20 24
1
4
SFP+
21 43 21 43 65 87 10
912
11 14
13 16
15 18
17 20
19 18
17 20
19 22
21 24
23 22
21 24
23
COMBO COMBO
CLI
PWR1
PWR2 SFP+
SYS
1 5 9 13 17 21
4 8 12 16 20 24
1
4
21 43
SFP+
21 43 65 87 109 1211 13
2625 2827
Table of contents
Languages:
Other FS Switch manuals

FS
FS S5850-24XMG-U Series User manual

FS
FS S2805S Series User manual

FS
FS S3700-24T4F Instruction Manual

FS
FS PoE+ Series User manual

FS
FS T5850 Series User manual

FS
FS IES5100-24TF User manual

FS
FS S5850-24XMG User manual

FS
FS S5860-24XB-U User manual

FS
FS S5500-48T8SP User manual

FS
FS S5850-24S2Q-DC User manual