Introduction
Thank you for choosing N9510-64D switch. This guide is designed to familiarize you with the
layout of the switch and describes how to deploy the switch in your network.
Accessories
Grounding Cable x1Power Cord x4 M6*16 Screw x12
M6 Nut x12 Sliding Rail x2
N9510-64D
1F 2F 5F 6F 9F 10F 13F 14F 17F 18F 21F 22F 25F 26F 29F 30F 33F 34F 37F 38F 41F 42F 45F 46F 49F 50F 53F 54F 57F 58F 61F 62F
3F 4F 7F 8F 11F 12F 15F 16F 19F 20F 23F 24F 27F 28F 31F 32F 35F 36F 39F 40F 43F 44F 47F 48F 51F 52F 55F 56F 59F 60F 63F 64F
N9510-64D
ASSETTAG
FUNC
CONSOLE MGMT
Link Act
SYS BMCPSU FAN ID
1
EN

1F 2F 5F 6F 9F 10F 13F 14F 17F 18F 21F 22F 25F 26F 29F 30F 33F 34F 37F 38F 41F 42F 45F 46F 49F 50F 53F 54F 57F 58F 61F 62F
3F 4F 7F 8F 11F 12F 15F 16F 19F 20F 23F 24F 27F 28F 31F 32F 35F 36F 39F 40F 43F 44F 47F 48F 51F 52F 55F 56F 59F 60F 63F 64F
N9510-64D
ASSETTAG
FUNC
CONSOLE MGMT
Link Act
SYS BMCPSU FAN ID
Hardware Overview
Front Panel Ports
Ports Description
QSFPDD
USB
MGMT
QSFPDD ports for 100/400G connection.
A USB management port for software, configuration backup and offline
software upgrade.
An ethernet management port.
CONSOLE An RJ45 console port for serial management.
MGMT
USB
CONSOLE QSFPDD
Front Panel LEDs
1F 2F 5F 6F 9F 10F 13F 14F 17F 18F 21F 22F 25F 26F 29F 30F 33F 34F 37F 38F 41F 42F 45F 46F 49F 50F 53F 54F 57F 58F 61F 62F
3F 4F 7F 8F 11F 12F 15F 16F 19F 20F 23F 24F 27F 28F 31F 32F 35F 36F 39F 40F 43F 44F 47F 48F 51F 52F 55F 56F 59F 60F 63F 64F
N9510-64D
ASSETTAG
FUNC
CONSOLE MGMT
Link Act
SYS BMCPSU FAN ID
SYS /BMC/ PSU /FAN/ ID
Asset Tag Link/Act
2
EN

LEDs Description
SYS
BMC
The system is malfunctional.
The system is powered off.
The system is abnormal.
The BMC module works normally.
The BMC module is not-in-position or not working.
The BMC module hasn’t finished functional initialization.
The control function of the fun hasn’t finished initialization.
The system is powered off.
The fun works normally.
More than one fans are not in-the-position.
More than one fans work abnormally.
FAN
The system is powered off.
The control function of the power supply hasn’t finished
initialization.
The power supply is in a normal state.
The system is initializing.
The system is operational.
PSU
More than one power supplies are not connected with AC
power cord.
More than one power supply modules are in an abnormal
state.
CPLD sets default control and doesn’t locate position.
ID Positioning on the site. The operational people control
opening and closing of ID light.
State
Solid Red
Blinking Green
Solid Green
Off
Blinking Green
Solid Yellow
Solid Red
Blinking Green
Off
Solid Green
Off
Blinking Green
Solid Green
Off
Solid Green
Solid Yellow
Solid Yellow
Solid Red
Off
Solid Blue
3
EN

LEDs DescriptionState
Power Supply
Grounding point
Back Panel Ports
LINK/ACT
QSFPDD
The port is connected at 1000Mbps.
The port is not connected.
The port is transmitting or receiving data.
The port is connected at 400/100G.
The port is not connected.
The port is transmitting or receiving data at 400/100G.
The port is connected at 100Mbps.
The port is not transmitting or receiving data.
Solid Green
Solid Yellow
Solid Green
Off
Blinking Green
Link Off
Act Off
Act Blinking Green
FAN1
PSU1
FAN3
FAN2
FAN4
FAN5
FAN6
FAN7FAN8
PSU2
PSU3PSU4
Fan Slots
4
EN

LEDs Description
Fan Status
The fan is initializing.
The fan is powered off.
There is no power input or the power supply fails.
1.The AC power is off and it is only 12VBS.
2.The AC power is cold standby and it doesn’t output
efficiency.
The power output is normal.
1.An error occurs, e.g. overcurrent, overvoltage or fan fault.
2.The AC power in redundancy is plugged out.
An alarm is generated but the power module keeps working.
The alarm may be caused by high power, high current, high
temperature, or low fan rotation speed.
Power Supply
Status
The fan is operational.
The fan fails or stops.
State
Blinking Green
Solid Green
Blinking Green
Solid Green
Red Light
Blinking Red
Off
Solid Red
Off
Power Supply Status
Back Panel LEDs
FAN1
PSU1
FAN3
FAN2
FAN4
FAN5FAN6
FAN7FAN8
PSU2
PSU3PSU4
Fan Status
5
EN

Installation Requirements
Before you begin the installation, make sure that you have the
followings:
Phillips screwdriver.
Category 5e or higher RJ45 Ethernet cables, fiber optical cables and console cable for
network devices.
Site Environment:
The operating temperature is 0°C-40°C, the humidity is 10%-90%.
The installation site must be free from leaking or dripping water, heavy dew, and humidity.
The installation site must be well ventilated. Ensure that there is adequate airflow around
the switch.
Be sure that the switch is level and stable to avoid any hazardous conditions.
Do not install the equipment in a dusty environment.
Ensure rack and working platforms are well earthed.
6
EN

1F 2F 5F 6F 9F 10F 13F 14F 17F 18F 21F 22F 25F 26F 29F 30F 33F 34F 37F 38F 41F 42F 45F 46F 49F 50F 53F 54F 57F 58F 61F 62F
3F 4F 7F 8F 11F 12F 15F 16F 19F 20F 23F 24F 27F 28F 31F 32F 35F 36F 39F 40F 43F 44F 47F 48F 51F 52F 55F 56F 59F 60F 63F 64F
N9510-64D
ASSETTAG
FUNC
CONSOLE MGMT
Link Act
SYSBMC PSU FAN ID
1. Secure the two L-shaped brackets to assemble a rack with eight M6 nuts.
2. Attach the switch to the rack and use four M6 screws to fix.
Rack Mounting
Mounting the Switch
7
EN

Replacing the Power Supply Module
1. Press the power supply module and pull the handle of it slowly and straightly.
2. Hold the handle of the power module with one hand, and hold the bottom with the other
hand.
3. Horizontally push the power module into the slot. The power module completely inserts in the
slot until a “click” is heard.
FAN3
FAN2
FAN4
FAN5FAN6
FAN7FAN8
PSU2
PSU3PSU4
FAN1
PSU1
FAN3
FAN2
FAN4
FAN5FAN6
FAN7FAN8
PSU2
PSU3PSU4
8
EN

NOTE: 1. Insert the power/fan module steadily and pay attention to the direction of
the fan module. If the position is not proper, pull the module and re-insert it.
2. If the fan module can be extracted without pushing the handle, maybe the fan
module is not inserted into the switch totally, please check carefully.
Replacing the Fan Module
1. Push the handle of the fan module and pull out the fan module slowly.
2. Hold the handle of the fan module and insert it into the chassis slowly, ensure the fan module
has a good contact with the slot until a “click” is heard.
FAN3
FAN2
FAN4
FAN5FAN6
FAN7FAN8
PSU2
PSU3PSU4
FAN1
PSU1
FAN3
FAN2
FAN4
FAN5FAN6
FAN7FAN8
PSU2
PSU3PSU4
9
EN

10
EN
FAN1
PSU1
FAN3
FAN2
FAN4
FAN5FAN6
FAN7FAN8
PSU2
PSU3PSU4
1. Connect one end of the grounding cable to a proper earth ground, such as the rack in which
the switch is mounted.
2. Connect the other end of the grounding cable on the switch back panel with the washers
and screws.
Grounding the Switch
FAN1
PSU1
FAN3
FAN2
FAN4
FAN5FAN6
FAN7FAN8
PSU2
PSU3PSU4
Connecting the power
1. Plug the AC power cord into the power port on the back of the switch.
2. Connect the other end of the power cord to an AC power source.

1F 2F 5F 6F 9F 10F 13F 14F 17F 18F 21F 22F 25F 26F 29F 30F 33F 34F 37F 38F 41F 42F 45F 46F 49F 50F 53F 54F
3F 4F 7F 8F 11F 12F 15F 16F 19F 20F 23F 24F 27F 28F 31F 32F 35F 36F 39F 40F 43F 44F 47F 48F 51F 52F 55F 56F
N9510-64D
ASSETTAG
FUNC
CONSOLE MGMT
Link Act
SYS BMCPSU FA N ID
1F 2F 5F 6F 9F 10F 13F 14F 17F 18F 21F 22F 25F 26F 29F 30F 33F 34F 37F 38F 41F 42F 45F 46F 49F 50F 53F 54F 57F 58F 61F 62F
3F 4F 7F 8F 11F 12F 15F 16F 19F 20F 23F 24F 27F 28F 31F 32F 35F 36F 39F 40F 43F 44F 47F 48F 51F 52F 55F 56F 59F 60F 63F 64F
N9510-64D
ASSETTAG
FUNC
CONSOLE MGMT
Link Act
SYSBMC PSU FAN ID
Connecting the QSFPDD ports
1. Insert QSFPDD transceiver module into the switch.
2. Connect the fiber optic cable to the transceiver port, or directly connect DAC cable to the
transceiver module
Connecting the Console Port
1. Insert the RJ45 connector into the RJ45 CONSOLE port of the switch.
2. Connect the other end of the console cable to the port on the computer.
11
EN

1F 2F 5F 6F 9F 10F 13F 14F 17F 18F 21F 22F 25F 26F 29F 30F 33F 34F 37F 38F 41F 42F 45F 46F 49F 50F 53F 54F 57F 58F 61F 62F
3F 4F 7F 8F 11F 12F 15F 16F 19F 20F 23F 24F 27F 28F 31F 32F 35F 36F 39F 40F 43F 44F 47F 48F 51F 52F 55F 56F 59F 60F 63F 64F
N9510-64D
ASSETTAG
FUNC
CONSOLE MGMT
Link Act
SYS BMCPSU FAN ID
54F 57F 58F 61F 62F
56F 59F 60F 63F 64F
12
EN
Connecting the USB Port
Insert the Universal Serial Bus(USB) flash disk to the USB port for software and configuration
backup and offline software upgrade.
1F 2F 5F 6F 9F 10F 13F 14F 17F 18F 21F 22F 25F 26F 29F 30F 33F 34F 37F 38F 41F 42F 45F 46F 49F 50F 53F 54F 57F 58F 61F 62F
3F 4F 7F 8F 11F 12F 15F 16F 19F 20F 23F 24F 27F 28F 31F 32F 35F 36F 39F 40F 43F 44F 47F 48F 51F 52F 55F 56F 59F 60F 63F 64F
N9510-64D
ASSETTAG
FUNC
CONSOLE MGMT
Link Act
SYS BMCPSU FAN ID
Connecting the MGMT Port
1. Connect one end of a standard RJ45Ethernet cable to a computer.
2. Connect the other end of the cable to the MGMT port of the switch.
USB

Step1: Connect a computer to the console port of the switch using the console cable.
Step2: Start the terminal simulation software such as HyperTerminal on the computer.
Step3: Set the parameters of the HyperTerminal:115200 bits per second, 8 data bits, no parity,
1 stop bit and no flow control.
Step4: After setting the parameters, click Connect to enter.
Troubleshooting
Configuring the Switch
The indicator on the front panel of the host is OFF. The Status indicator of the fan module is OFF,
and the fan does not work. The indicator of the power module is OFF.
Please check the following:
First disconnect the power cord of the power module.
1. Whether the cables of the cabinet have been correctly connected.
2. Whether the cabinet power sockets are loosely connected to power modules.
3. Whether the power modules are installed correctly.
Power System Has Fault
Configuring the Switch Using the Console Port
x
Quick Connect
Protocol:
The port may be manually entered or selected from the list.
Serial
Flow Control
DTR/DSR
RTS/CTS
XON/XOFF
Save sessionShow quick connect on startup
Open in a tab
Connect
Cancel
COM3
115200
8
None
1
Port:
Baud rate:
Data bits:
Parity:
Stop bits:
Name of pipe:
13
EN

Online Resources
Download https://www.fs.com/products_support.html
Help Center https://www.fs.com/service/fs_support.html
Contact Us https://www.fs.com/contact_us.html
Product Warranty
Warranty: N9510-64D switch enjoys 5 years limited warranty against defects in
materials or workmanship. For more details about warranty, please check at
https://www.fs.com/policies/warranty.html
5
Return: If you want to return item(s), information on how to return can be found at
https://www.fs.com/policies/day_return_policy.html
1. Check whether serial port cable is connected correctly, Whether serial port cable is
disconnected, and whether the connected serial port is identical with that configured on the
HyperTerminal.
2. Check that the parameter configuration of the serial port matches that specified in the
instructions.
Serial Port Console Has No Output or Outputs Illegible Characters
1. check whether the module is inserted correctly.
2. If the newly-inserted module still cannot be powered on even though the checking is ok,
please contact us for technical support.
The Newly-inserted Service Card Module Fails to Be Powered on
14
EN

15
Einführung
Vielen Dank, dass Sie sich für den Switch N9510-64D entschieden haben. Diese Anleitung soll Sie
mit dem Aufbau des Switches vertraut machen und beschreibt, wie Sie den Switch in Ihrem
Netzwerk einsetzen.
Zubehör
Erdungskabel x1Netzkabel x4 M6*16 Schraube x12
M6-Mutter x12 Gleitschiene x2
N9510-64D
1F 2F 5F 6F 9F 10F 13F 14F 17F 18F 21F 22F 25F 26F 29F 30F 33F 34F 37F 38F 41F 42F 45F 46F 49F 50F 53F 54F 57F 58F 61F 62F
3F 4F 7F 8F 11F 12F 15F 16F 19F 20F 23F 24F 27F 28F 31F 32F 35F 36F 39F 40F 43F 44F 47F 48F 51F 52F 55F 56F 59F 60F 63F 64F
N9510-64D
ASSETTAG
FUNC
CONSOLE MGMT
Link Act
SYS BMCPSU FAN ID
DE

16
1F 2F 5F 6F 9F 10F 13F 14F 17F 18F 21F 22F 25F 26F 29F 30F 33F 34F 37F 38F 41F 42F 45F 46F 49F 50F 53F 54F 57F 58F 61F 62F
3F 4F 7F 8F 11F 12F 15F 16F 19F 20F 23F 24F 27F 28F 31F 32F 35F 36F 39F 40F 43F 44F 47F 48F 51F 52F 55F 56F 59F 60F 63F 64F
N9510-64D
ASSETTAG
FUNC
CONSOLE MGMT
Link Act
SYS BMCPSU FAN ID
Hardware-Übersicht
Ports an der Vorderseite
Port Beschreibung
QSFPDD
USB
MGMT
QSFPDD-Ports für 100/400G-Verbindungen.
Ein USB-Verwaltungsport für Software, Konfigurationssicherung und Offline-
Software-Upgrade.
Ein Ethernet-Verwaltungsport.
CONSOLE Ein RJ45-Console-Port für die serielle Verwaltung.
MGMT
USB
CONSOLE QSFPDD
LEDs an der Vorderseite
1F 2F 5F 6F 9F 10F 13F 14F 17F 18F 21F 22F 25F 26F 29F 30F 33F 34F 37F 38F 41F 42F 45F 46F 49F 50F 53F 54F 57F 58F 61F 62F
3F 4F 7F 8F 11F 12F 15F 16F 19F 20F 23F 24F 27F 28F 31F 32F 35F 36F 39F 40F 43F 44F 47F 48F 51F 52F 55F 56F 59F 60F 63F 64F
N9510-64D
ASSETTAG
FUNC
CONSOLE MGMT
Link Act
SYS BMCPSU FAN ID
SYS /BMC/ PSU /FAN/ ID
Asset Tag Link/Act
DE

17
LED Beschreibung
SYS
BMC
Das System funktioniert nicht.
Das System ist ausgeschaltet.
Das System ist fehlerhaft.
Das BMC-Modul funktioniert normal.
Das BMC-Modul ist nicht an seinem Platz oder funktioniert
nicht.
Das BMC-Modul hat die funktionale Initialisierung noch nicht
abgeschlossen.
Die Steuerfunktion des Lüfters hat die Initialisierung noch
nicht abgeschlossen.
Das System ist ausgeschaltet.
Der Lüfter funktioniert normal.
Mehr als ein Lüfter sind nicht in Position.
Mehrere Lüfter arbeiten fehlerhaft.
LÜFTER
Das System ist ausgeschaltet.
Die Steuerfunktion des Netzteils hat die Initialisierung noch
nicht abgeschlossen.
Die Stromversorgung befindet sich in einem normalen
Zustand.
Das System wird initialisiert.
Das System ist betriebsbereit.
PSU
Mehr als ein Netzgerät ist nicht mit dem Netzkabel verbunden.
Mehr als ein Stromversorgungsmodul befinden sich in einem
fehlerhaften Zustand.
CPLD stellt die Standardsteuerung ein und lokalisiert die
Position nicht.
ID Positionierung auf der Website. Die Bediener steuern das
Öffnen und Schließen der ID-Leuchte.
Status
Durchgehend Rot
Blinkt Grün
Durchgehend Grün
Aus
Blinkt Grün
Durchgehend Gelb
Durchgehend Rot
Blinkt Grün
Aus
Durchgehend Grün
Aus
Blinkt Grün
Durchgehend Grün
Aus
Durchgehend Grün
Durchgehend Gelb
Durchgehend Gelb
Durchgehend Rot
Aus
Durchgehend Blau
DE

18
LED BeschreibungStatus
Netzanschluss
Erdungspunkt
Ports an der Rückseite
LINK/ACT
QSFPDD
Der Port ist mit 1000Mbps angeschlossen.
Der Port ist nicht verbunden.
Der Port sendet oder empfängt gerade Daten.
Der Port ist mit 400/100G angeschlossen.
Der Port ist nicht verbunden.
Der Port sendet oder empfängt Daten mit 400/100G.
Der Port ist mit 100Mbps verbunden.
Der Port sendet oder empfängt keine Daten.
Durchgehend Grün
Durchgehend Gelb
Durchgehend Grün
Aus
Blinkt Grün
Verbindung aus
Act Aus
Act Blinkt Grün
FAN1
PSU1
FAN3
FAN2
FAN4
FAN5
FAN6
FAN7FAN8
PSU2
PSU3PSU4
Lüfter-Steckplätze
DE

19
LED Beschreibung
Lüfter Status
Der Lüfter wird initialisiert.
Der Lüfter ist ausgeschaltet.
Es gibt keine Stromzufuhr oder die Stromversorgung
fällt aus.
1. Die AC-Stromversorgung ist ausgeschaltet und es
sind nur 12VBS.
2. Die AC-Stromversorgung ist im kalten Standby-
Modus und hat keinen Leistungsgrad.
Die Stromversorgung ist normal.
1. Ein Fehler tritt auf, z. B. Überstrom, Überspannung
oder Lüfterfehler.
2. Die AC-Stromversorgung ist in der Redundanz
ausgesteckt.
Es wird ein Alarm ausgelöst, aber das Leistungsmodul
arbeitet weiter. Der Alarm kann durch eine hohe
Leistung, einen hohen Strom, eine hohe Temperatur
oder eine niedrige Lüfterdrehzahl verursacht werden.
Status der
Stromversorgung
Der Lüfter ist betriebsbereit.
Der Lüfter fällt aus oder stoppt.
Status
Blinkt Grün
Durchgehend Grün
Blinkt Grün
Durchgehend Grün
Rotes Licht
Blinkt Rot
Aus
Durchgehend Rot
Aus
Stromversorgungsstatus
LEDs an der Rückseite
FAN1
PSU1
FAN3
FAN2
FAN4
FAN5
FAN6
FAN7
FAN8
PSU2
PSU3PSU4
Lüfter-Status
DE
Table of contents