FS S3200 Series User manual

Switch Ethernet Manageable L3
L3 Managed Ethernet-Switch
S3200 Series Switches
L3 Managed Ethernet Switch
V1.0
Quick Start Guide
Quick Start Anleitung
Guide de Démarrage Rapide
S3200-8M4GS-U PoE+
Left LED: Link/Act Mode Right LED: PoE Mode
SYS
PWR
PoE
CONSOLE
1 2 3 4 5 6 7 8
9 10 11 12
10G
1 2 3 4
SYS
PWR
CONSOLE
5 6 7 8
9 10 11 12
S3200-8M4GS Left LED: Link/Act Mode
10G

Introduction
Thank you for choosing S3200 Series Switches. This guide is designed to familiarize you with the layout
of the S3200 Series Switches and describes how to deploy them in your network.
Accessories
S3200-8M4GS-U/S3200-8MG4S
1
EN
Grounding Cable x1
Power Cord x1 Mounting Bracket x2
M4 Screw x8
Rubber Pad x4
Console Cable x1
S3200-8MG4S-U
S3200-8MG4S
1 2 3 4
SYS
PWR
CONSOLE
5 6 7 8
9 10 11 12
S3200-8M4GS Left LED: Link/Act Mode
10G
Left LED: Link/Act Mode Right LED: PoE Mode
SYS
PWR
PoE
CONSOLE
S3200-8M4GS-U PoE+
1 2 3 4 5 6 7 8
9 10 11 12
10G

S3200-8M4GS-U
Hardware Overview
Front Panel Ports
S3200-8M4GS-U
Front Panel LEDs
Port Description
CONSOLE
PoE RJ45
SFP+
A RJ45 console port for serial management
10/100/1000/2.5Base-T ports for Ethernet connection
SFP+ ports for 1/10G connection
Port Description
CONSOLE
RJ45
SFP+
A RJ45 console port for serial management
10/100/1000/2.5Base-T ports for Ethernet connection
SFP+ ports for 1/10G connection
2
EN
PWR
SYS PoE RJ45 PoE SFP+
Left LED: Link/Act Mode Right LED: PoE Mode
SYS
PWR
PoE
CONSOLE
1 2 3 4 5 6 7 8
9 10 11 12
10G
S3200-8M4GS-U PoE+
CON RJ45 SFP+
1 2 3 4
SYS
PWR
CONSOLE
5 6 7 8
9 10 11 12
S3200-8M4GS Left LED: Link/Act Mode
10G
CON RJ45 SFP+
S3200-8M4GS-U PoE+
Left LED: Link/Act Mode Right LED: PoE Mode
SYS
PWR
PoE
CONSOLE
1 2 3 4 5 6 7 8
9 10 11 12
10G

S3200-8MG4S
LED State Description
PWR
SYS
PoE
RJ45
SFP+
Green (Solid) Power is provided to the switch.
The switch is not connect to power or power
failure occurred.
The switch has loaded the agent software code
and is operating normally.
The system operating failure occurred.
The system operating failure occurred.
Total POE budget≧15.4W, to indicate total
budget is sufficient.
Total POE budget<15.4W, early warning total
budget may insufficient.
Total POE budget≦0W, to warn total budget is
empty.
OFF
Green (Blinking)
Green (Solid)
OFF
Green (Solid)
Yellow (Solid)
Red (Solid)
The port is linked and the bandwidth could be
10M/100M/1000M/2500M.
The port is linked and there is data activity.
No link.
The port is supplying power to PD device.
The port is not connecting to PD device.
Link/act
Green (Solid)
Green (Blinking)
OFF
Green (Solid)
PoE
OFF
Green (Solid)
Green (Blinking)
OFF
The port is linked and the bandwidth could be
100M/1000M/10G.
The port is linked and there is data activity.
No link.
EN
3
1 2 3 4
SYS
PWR
CONSOLE
5 6 7 8
9 10 11 12
S3200-8M4GS Left LED: Link/Act Mode
10G
PWR
SYS RJ45 SFP+

S3200-8MG4S-U/S3200-8MG4S
Back Panel
LED State Description
PWR
SYS
RJ45
SFP+
Green (Solid) Power is provided to the switch.
The switch is not connect to power or power
failure occurred.
The switch has loaded the agent software code
and is operating normally.
The system operating failure occurred.
The system operating failure occurred.
The port is linked and the bandwidth could be
10/100/1000M.
The port is linked and there is data activity.
No link.
OFF
Green (Blinking)
Green (Solid)
OFF
10/100/1000M
Link/act
Yellow (Solid)
Yellow(Blinking)
OFF
The port is linked and the bandwidth is 2.5G.
The port is linked and there is data activity.
No link.
The port is linked and the bandwidth could be
100M/1G/10G.
The port is linked and there is data activity.
2.5G Link/act
Green (Solid)
Green (Blinking)
OFF
Green (Solid)
Green (Blinking)
OFF No link.
Grounding Point
POWER
Before installation, make sure that you have the followings:
Installation Requirements
Phillips screwdriver.
Standard-sized, 19" wide rack with a minimum of 1U height available.
Category 5e or higher RJ-45 Ethernet cables for connecting network devices.
EN
4

Make sure that the relative humidity of installation site is maintained at 10%~90%.
Site Environment:
Make sure that the temperature of installation site is maintained at 0°~50°.
The installation site must be well ventilated. Ensure that there is adequate air flow around the
switch.
Make sure that the switch is level and stable to avoid any hazardous conditions.
Make sure that the rack and working platforms are well earthed.
The installation site must be free from leaking, dripping water or heavy dew.
Keep the installation site dust-free.
Desk Mounting
Mounting the Switch
1. Attach four rubber pads to the bottom of switch.
2. Place the switch on a desk.
Left LED: Link/Act Mode RightLED: PoE Mode
SYS
PWR
PoE
CONSOLE
S3200-8M4GS-U PoE+
1 2 3 4 5 6 7 8
910 11 12
10G
EN
5
Left LED: Link/Act Mode Right LED: PoE Mode
SYS
PWR
POE
CONSOLE
S3200-8M4GS-U PoE+
1 2
COMBO
65 87 21 43
On=Link Flashing=ACT Green=1000M Yellow=10/100M

Rack Mounting
1. Fix the mounting brackets to the two sides of the switch with eight M4 screws.
2. Fix the switch to the rack with M6 screws and cage nuts.
NOTE: For wall mounting, you need to turn the mounting brackets to 90°and fix them to the two
sides of the switch. Then mount the switch on the wall.
EN
6
Left LED: Link/Act Mode Right LED: PoE Mode
3 4 5 6 7 8
910 11 12
10G
465 87 109 1211
Left LED: Link/Act Mode Right LED: PoE Mode
SYS
PWR
POE
CONSOLE
S3200-8M4GS-U PoE+
1 2 3 4 5 6 7 8
910 11 12
10G

1. Connect one end of the grounding cable to a proper earth ground, such as the rack in which the
switch is mounted.
2. Fix the grounding lug to the grounding point on the back panel of the switch with the washers and
screws.
Grounding the Switch
Connecting the Power
CAUTION: The earth connection must not be removed unless all supply connections have been
disconnected.
EN
7

1. Plug the AC power cord into the power port on the back panel of the switch.
2. Connect the other end of the power cord to an AC power source.
1. Connect one end of an Ethernet cable to the RJ45 port.
2. Connect the other end of the Ethernet cable to another network device.
Connecting the RJ45 Ports
Connecting the SFP/SFP+ Port
WARNING: Do not install power cord while the power is on.
EN
8
Left LED: Link/Act Mode Right LED: PoE Mode
SYS
PWR
PoE
CONSOLE
S3200-8M4GS-U PoE+
1 2 3 4 5 6 7 8
10G
S3200-8M4GS-U PoE+
Left LED: Link/Act Mode RightLED: PoE Mode
SYS
PWR
PoE
CONSOLE
1 2 3 4 5 6 7 8
910 11 12
10G

1. Plug the compatible SFP/SFP+ optical module into the SFP/SFP+ port.
2. Connect one end of a fiber optic cable to the optical module. Then connect the other end of the
cable to another fiber device.
1. Insert the RJ45 connector of the console cable into the console port of the switch.
2. Connect the DB9 female connector of the console cable to the serial port of the computer.
Connecting the CONSOLE Port
WARNING: Laser beams will cause eye damage. Do not look into bores of optical modules or
fiber optical cables without eye protection.
Configuring the Switch
Configuring the Switch via the Web-based Interface
Step 1: Connect the computer to the Management port of the switch using the network cable.
Step 2: Set the IP address of the computer to 192.168.1.x.(“x”is any number from 2 to 254.)
EN
9
Left LED: Link/Act Mode Right LED: PoE Mode
SYS
PWR
PoE
CONSOLE
S3200-8M4GS-U PoE+
1 2 3 4 1 2 3 4

?x
OK Cancel
General
IP address:
Subnet mask:
Default gateway:
You can get IP settings assigned automatically if your network
supports this capability. Otherwise, you need to ask your network
administrator for the appropriate IP settings.
Internet Protocol Version 4(TCP/IPv4) Properties
Use the following IP address:
Obtain an IP address automatically
Preferred DNS server:
Alternate DNS server:
Validate settings upon exit Advanced...
. . . 21168192
0255
255255
. . .
. . .
. . .
. . .
Obtain DNS server address automatically
Use the following DNS server addresses:
Step 3: Open a browser, type http://192.168.1.1, and enter the default username and password,
admin/admin.
Step 4: Click Login to display the web-based configuration page.
IE 8/9/10/11, Google Chrome, Firefox are supported
Login
admin
*****
Configuring the Switch via the Console Port
Step 1: Connect a computer to the switch's console port using the console cable.
Step 2: Start the terminal simulation software such as HyperTerminal on the computer.
Step 3: Set the parameters of the HyperTerminal: 9600 bits per second, 8 data bits, no parity, 1
stop bit and no flow control.
EN
10
10G

Step 4: After setting the parameters, click Connect to enter.
x
Quick Connect
Protocol:
The port may be manually entered or selected from the list.
Serial
Flow Control
DTR/DSR
RTS/CTS
XON/XOFF
Save sessionShow quick connect on startup
Open in a tab
Connect
Cancel
COM3
9600
8
None
1
Port:
Baud rate:
Data bits:
Parity:
Stop bits:
Name of pipe:
Troubleshooting
All indicators on the front panel of the switch are off. The status indicator of the fan module is off. The
indicator on the panel of the power module is off. The fan does not work. First disconnect the power
cord of the power module, then check the following:
1. Check whether the cable connections of the rack are correct.
2. Check whether the connection between the power socket and the power cord is loose.
3. Check whether the connection between the power module and the power cord is loose.
4. Check whether the power module inserts into place.
1. Test network connectivity through ping.
2. If the network is reachable, try restarting the switch.
3. Check whether the corresponding service enables.
The Power Module Cannot Supply Power
Connecting the Switch Remotely Unsuccessfully
EN
11

1. Check whether the console cable is correctly connected.
2. Check whether the console cable is broken.
3. Check whether the console port of the switch is the same as the port of the terminal device.
4. Check whether the console port configuration of the terminal device is correct.
FS ensures our customers that if there are any damage or faulty items due to our workmanship, we
will offer a free return within 1 month from the day you receive your goods. This excludes any custom
made items or tailored solutions.
1. Check whether the receiving and delivering of fiber optical cable connects correctly.
2. Check whether the wavelengths of optical modules of the interconnection are the same.
3. Check whether the distance of the interconnection is within the distance marked by the optical
module.
4. Check whether the rates of the interconnection are the same or whether the mode of port rate
is configured correctly for ports which support different rates.
5. Check whether the optical fiber type meets the requirements.
The Optical Port Cannot Link up
No Characters/Distorted Characters are Displayed on the Screen of the
Terminal Device
Online Resources
Download
Help Center
Contact Us
https://www.fs.com/products_support.html
https://www.fs.com/service/fs_support.html
https://www.fs.com/contact_us.html
Product Warranty
Warranty: This product enjoys 4 years limited warranty against defect in materials or
workmanship. For more details about warranty, please check at
https://www.fs.com/policies/warranty.html
Return: If you want to return item(s), information on how to return can be found at
https://www.fs.com/policies/day_return_policy.html
4
EN
12

Einführung
Vielen Dank, dass Sie sich für Switches der Serie S3200 entschieden haben. Diese Anleitung soll Sie mit
dem Aufbau der Switches der Serie S3200 vertraut machen und beschreibt, wie Sie sie in Ihrem
Netzwerk einsetzen können.
Zubehör
Erdungskabel x1
Netzkabel x1 Montagebügel x2
M4-Schraube x8
Gummiunterlage x4
Konsolenkabel x1
13
DE
S3200-8M4GS-U/S3200-8MG4S
S3200-8MG4S-U
S3200-8MG4S
1 2 3 4
SYS
PWR
CONSOLE
5 6 7 8
9 10 11 12
S3200-8M4GS Left LED: Link/Act Mode
10G
Left LED: Link/Act Mode Right LED: PoE Mode
SYS
PWR
PoE
CONSOLE
S3200-8M4GS-U PoE+
1 2 3 4 5 6 7 8
9 10 11 12
10G

14
DE
S3200-8MG4S-U
S3200-8MG4S
Hardware-Übersicht
Anschlüsse an der Vorderseite
S3200-8M4GS-U
LEDs an der Vorderseite
Port Beschreibung
CONSOLE
PoE RJ45
SFP+
Ein RJ45-Console-Port für die serielle Verwaltung
10/100/1000/2,5Base-T-Ports für den Ethernet-Anschluss
SFP+-Ports für 1/10G-Verbindungen
Port Beschreibung
CONSOLE
RJ45
SFP+
Ein RJ45-Console-Port für die serielle Verwaltung
10/100/1000/2,5Base-T-Ports für den Ethernet-Anschluss
SFP+-Ports für 1/10G-Verbindungen
PWR
SYS PoE RJ45 PoE SFP+
Left LED: Link/Act Mode Right LED: PoE Mode
SYS
PWR
PoE
CONSOLE
1 2 3 4 5 6 7 8
9 10 11 12
10G
S3200-8M4GS-U PoE+
CON RJ45 SFP+
1 2 3 4
SYS
PWR
CONSOLE
5 6 7 8
9 10 11 12
S3200-8M4GS Left LED: Link/Act Mode
10G
CON RJ45 SFP+
S3200-8M4GS-U PoE+
Left LED: Link/Act Mode Right LED: PoE Mode
SYS
PWR
PoE
CONSOLE
1 2 3 4 5 6 7 8
9 10 11 12
10G

S3200-8MG4S
LED Status Beschreibung
PWR
SYS
PoE
RJ45
SFP+
Grün (Durchgehend) Der Switch wird mit Strom versorgt.
Der Switch ist nicht mit dem Stromnetz
verbunden oder ein Stromausfall ist aufgetreten.
Der Switch hat den Softwarecode des Agenten
geladen und arbeitet normal.
Der Systembetrieb ist ausgefallen.
Der Systembetrieb ist ausgefallen.
POE-Gesamtbudget≧15,4 W, um anzuzeigen,
dass das Gesamtbudget ausreicht.
POE-Gesamtbudget<15,4W, Frühwarn-
Gesamtbudget möglicherweise unzureichend.
Gesamtes POE-Budget≦0W, zur Warnung, dass
das Gesamtbudget leer ist.
AUS
Grün (Blinkt)
Grün (Durchgehend)
AUS
Grün (Durchgehend)
Gelb (Durchgehend)
Rot (Durchgehend)
Der Port ist verbunden und die Bandbreite kann
10M/100M/1000M/2500M betragen.
Der Port ist verbunden und es gibt
Datenaktivität.
Keine Verbindung.
Der Port versorgt das PD-Gerät mit Strom.
Der Port ist nicht mit dem PD-Gerät verbunden.
Link/act
Grün
(Durchgehend)
Grün (Blinkt)
AUS
Grün
(Durchgehend)
PoE
AUS
Grün (Durchgehend)
Grün (Blinkt)
AUS
Der Port ist verbunden und die Bandbreite kann
100M/1000M/10G betragen.
Der Port ist verbunden und es gibt
Datenaktivität.
Keine Verbindung.
DE
15
1 2 3 4
SYS
PWR
CONSOLE
5 6 7 8
9 10 11 12
S3200-8M4GS Left LED: Link/Act Mode
10G
PWR
SYS RJ45 SFP+

S3200-8MG4S-U/S3200-8MG4S
Rückseite
LED Status Beschreibung
PWR
SYS
RJ45
SFP+
Grün (Durchgehend) Der Switch wird mit Strom versorgt.
Der Switch ist nicht mit dem Stromnetz
verbunden oder ein Stromausfall ist aufgetreten.
Der Switch hat den Softwarecode des Agenten
geladen und arbeitet normal.
Der Systembetrieb ist ausgefallen.
Der Systembetrieb ist ausgefallen.
Der Port ist verbunden und die Bandbreite kann
10/100/1000M betragen.
Der Port ist verbunden und es gibt
Datenaktivität.
Keine Verbindung.
AUS
Grün (Blinkt)
Grün (Durchgehend)
AUS
10/100/1000M
Link/act
Gelt
(Durchgehend)
Gelb (Blinkt)
AUS
Der Port ist verbunden und die Bandbreite
beträgt 2,5G.
Der Port ist verbunden und es gibt
Datenaktivität.
Keine Verbdindung.
Der Port ist verbunden und die Bandbreite kann
100M/1G/10G betragen.
Der Port ist verbunden und es gibt
Datenaktivität.
2.5G Link/act
Grün
(Durchgehend)
Grün (Blinkt)
AUS
Grün (Durchgehend)
Grün (Blinkt)
AUS Keine Verbindung.
Vergewissern Sie sich vor der Installation, dass Sie die folgenden
Gegenstände besitzen:
Installationsvoraussetzungen
Kreuzschlitzschraubendreher.
Ein 19"-Rack in Standardgröße mit einer Mindesthöhe von 1 HE.
RJ-45-Ethernet-Kabel der Kategorie 5e oder höher für den Anschluss von Netzwerkgeräten.
DE
16
Erdungspunkt
STROMVERSORGUNG

Left LED: Link/Act Mode RightLED: PoE Mode
SYS
PWR
PoE
CONSOLE
S3200-8M4GS-U PoE+
1 2 3 4 5 6 7 8
910 11 12
10G
Achten Sie darauf, dass die Luftfeuchtigkeit am Aufstellungsort zwischen 10 und 90 % liegt.
Standortumgebung
Achten Sie darauf, dass die Temperatur am Aufstellungsort zwischen 0° und 50° gehalten wird.
Der Aufstellungsort muss gut belüftet sein. Stellen Sie sicher, dass um den Switch herum ein
ausreichender Luftstrom herrscht.
Stellen Sie sicher, dass der Switch waagerecht und stabil steht, um gefährliche Bedingungen zu
vermeiden.
Stellen Sie sicher, dass das Gestell und die Arbeitsbühnen gut geerdet sind.
Der Aufstellungsort muss frei von Leckagen, Tropfwasser oder starkem Tau sein.
Halten Sie den Aufstellungsort staubfrei.
Montage auf dem Tisch
Montage des Switches
1. Bringen Sie vier Gummipuffer an der Unterseite des Switches an.
2. Stellen Sie den Switch auf einen Tisch.
DE
17
Left LED: Link/Act Mode Right LED: PoE Mode
SYS
PWR
POE
CONSOLE
S3200-8M4GS-U PoE+
1 2
COMBO
65 87 21 43
On=Link Flashing=ACT Green=1000M Yellow=10/100M

Rack-Montage
1. Befestigen Sie die Montagehalterungen mit acht M4-Schrauben an den beiden Seiten des Switches.
2. Befestigen Sie den Switch mit M6-Schrauben und Käfigmuttern am Rack.
HINWEIS: Für die Wandmontage müssen Sie die Montagehalterungen um 90° drehen und an
den beiden Seiten des Switches befestigen. Montieren Sie den Switch dann an der Wand.
DE
18
Left LED: Link/Act Mode Right LED: PoE Mode
3 4 5 6 7 8
910 11 12
10G
465 87 109 1211
Left LED: Link/Act Mode Right LED: PoE Mode
SYS
PWR
POE
CONSOLE
S3200-8M4GS-U PoE+
1 2 3 4 5 6 7 8
910 11 12
10G

1. Schließen Sie ein Ende des Erdungskabels an eine geeignete Erdung an, z. B. an das Rack, in dem
der Switch montiert ist.
2. Befestigen Sie die Erdungslasche mit den Unterlegscheiben und Schrauben an dem Erdungspunkt
auf der Rückseite des Switches.
Erdung des Switches
Anschließen der Stromversorgung
ACHTUNG: Der Erdungsanschluss darf erst dann entfernt werden, wenn alle
Versorgungsanschlüsse abgezogen sind.
DE
19
This manual suits for next models
2
Table of contents
Languages:
Other FS Switch manuals

FS
FS S3910 Series User manual

FS
FS S5800-48F4S User manual

FS
FS S3400-48T6SP User manual

FS
FS S3700-24T4F Instruction Manual

FS
FS S3700-24T4F Instruction Manual

FS
FS STP Series User manual

FS
FS S1900-16TP User manual

FS
FS S5500-48T8SP Operating instructions

FS
FS S5800 Series User manual

FS
FS S3700-24T4F Instruction Manual
Popular Switch manuals by other brands

Lucent Technologies
Lucent Technologies LambdaUnite brochure

Zte
Zte ZXR10 5900E Series Hardware manual

socomec
socomec SIRCO PV Series instruction sheet

INTERTECHNO
INTERTECHNO ITLM-1000 Operating and installation instructions

Dell
Dell PowerConnect 3548 Getting started guide

Hirschmann
Hirschmann GigaLION-24TP user guide