FS S58 Series User manual

V2.0
HYPERCONVERGED
INFRASTRUCTURE SWITCHES
Quick Start Guide
S58 Series 10G/25G Switches
CON
ETH
USB
SYS FAN PWR1PWR2STCK IND
S5800-8TF12S
10/100/1000 BASE-T 100/1000BASE- X 10G BASE-X
1 2 3 41 2 3 45 6 7 8 5678910 11 12 13 14 15 16 17 18 19 20
SYS
ETH
CON
ID
S5850-24T16 S
10/100/1000 BASE -T
10G
3 4 56
1 2 7 8 11 12 13 14
910 15 16 19 20 21 2217 18 23 24 27 28 29 3025 26 31 32 33 34 35 36 37 38 39 40
SYS
ETH
CON
ID
S5850-24T 1 6B
10/100/1000 BA S E- T
10/25G
345 61 2 7 8 11 12 13 14
9 10 15 16 19 20 21 2217 18 23 24 27 28 29 30
25 26 31 32 33 34 35 36 37 38 39 40

Introduction
Accessories
Grounding Cable x1
Power Cord x2
Rubber Pad x4 M4 Screw x8
Console Cable x1
Thank you for choosing S58 series switches. This guide is designed to familiarize you with the layout
of the switches and describes how to deploy the switches in your network.
Network Cable x1
Mounting Bracket x2
S5800-8TF12S
CON
ETH
USB
SYS FAN PWR1 PWR2 STCK IND
S5800-8TF12S
10/100/1000 BASE-T 100/1000 BASE-X 10G BASE-X
1 2 3 4 1 2 3 45 6 7 8 5678910 11 12 13 14 15 16 17 18 19 20
S5850-24T16S
S5850-24T16B
SYS
ETH
CON
ID
S5850-24T16S
10/100/1000 BASE-T
10G
3 4 5 6
1 2 7 8 11 12 13 14
910 15 16 19 20 21 2217 18 23 24 27 28 29 30
25 26 31 32 33 34 35 36 37 38 39 40
SYS
ETH
CON
ID
S5850-24T16B
10/100/1000 BASE-T
10/25G
3 4 5 6
1 2 7 8 11 12 13 14
910 15 16 19 20 21 2217 18 23 24 27 28 29 30
25 26 31 32 33 34 35 36 37 38 39 40

Hardware Overview
Front Panel Ports
RJ45
CON
USB
SFP+ ports for 1/10G connection
An Ethernet management port
An RJ45 console port for serial management
ETH
10/100/1000BASE-T ports for Ethernet connection
SFP+
Ports Description
S5850-24T16B
S5850-24T16S
Ports Description
RJ45
SFP28
ETH
CON
10/100/1000BASE-T ports for Ethernet connection
SFP28 ports for 10/25G transceivers
An Ethernet management port
An RJ45 console port for serial management
USB A USB management port for software and conguration
backup and oine software upgrade
A USB management port for software and conguration
backup and oine software upgrade
RJ45USB
SYS
ETH
CON
ID
S5850-24T16B
10/100/1000 BASE-T
10/25G
3 4 5 6
1 2 7 8 11 12 13 14
910 15 16 19 20 21 2217 18 23 24 27 28 29 30
25 26 31 32 33 34 35 36 37 38
ETH
CON SFP28
39 40
RJ45USB
SYS
ETH
CON
ID
S5850-24T16S
10/100/1000 BASE-T
10G
3 4 5 6
1 2 7 8 11 12 13 14
910 15 16 19 20 21 2217 18 23 24 27 28 29 3025 26 31 32 33 34 35 36 37 38
ETH
CON SFP+
39 40

S5800-8TF12S
S5850-24T16S
CON
ETH
USB
SYS FAN PWR1 PWR2 STCK IND
S5850-8TF12S
10/100/1000 BASE-T 100/1000 BASE-X 10G BASE-X
1 2 3 4 1 2 3 45 6 7 8 5678910 11 12 13 14 15 16 17 18 19 20
RJ45 10G SFP+CON
USBETH
SFP
Ports Description
RJ45
SFP
SFP+
CON
10/100/1000 BASE-T ports for Ethernet connection
SFP ports for 100/1000 BASE-X transceivers
SFP+ ports for 1/10G transceivers
An RJ45 console port for serial management
ETH An Ethernet management port
USB
Combo Ports
/
LEDs
S5800-8TF12S
A USB management port for software and conguration
backup and oine software upgrade
S5850-24T16B
RJ45
SYS
ETH
CON
ID
S5850-24T16B
10/100/1000 BASE-T
10/25G
3 4 5 6
1 2 7 8 11 12 13 14
910 15 16 19 20 21 2217 18 23 24 27 28 29 30
25 26 31 32 33 34 35 36 37 38
ID SYS
SFP28
39 40
RJ45
SYS
ETH
CON
ID
S5850-24T16S
10/100/1000 BASE-T
10G
3 4 5 6
1 2 7 8 11 12 13 14
910 15 16 19 20 21 2217 18 23 24 27 28 29 3025 26 31 32 33 34 35 36 37 38
ID SYS
ETH SFP+
39 40
SYS P1 RJ45
P2 Location
SFP+
CON
ETH
USB
SYS FAN PWR1 PWR2 STCK IND
S5800-8TF12S
10/100/1000 BASE-T 100/1000 BASE-X 10G BASE-X
1 2 3 4 1 2 3 45 6 7 8 5678910 11 12 13 14 15 16 17 18 19 20
SFP

Blinking Green Quickly
(2Hz)
Blinking Green Slowly
(0.5Hz)
Green
Amber
Blinking Amber Quickly
Blinking Amber Slowly
O
LEDs Status Description
System is abnormal.
SYS
The system is running in u-boot mode.
The system is normally running.
The system occurs alarm or error.
No power or no system runs or runs abnormally.
System software is in initial state.
System is initial in u-boot mode.
Green
Green
Blinking Green
Green
Blinking Green
Green
Blinking Green
Amber
Blinking Amber
O
Amber
Blinking Amber
O
O
Blue
Amber
O
PWR
ID
ETH
RJ45
O
Power supply is ok.
Port is linked.
Power supply is abnormal.
Power supply is absent or single power supply
is abnormal.
ID indication function enable.
ID indication function disable.
Port is receiving or transmitting packets.
Port is not linked.
1G port is linked.
1G packets are receiving or transmitting.
10/100M port is linked.
Port is not linked.
SFP+
10G port is linked.
10G packets are receiving or transmitting.
1G port is linked.
1G packets are receiving or transmitting.
Port is not linked.
10/100M packets are receiving or transmitting.
Green
Amber
O
25G port is linked.
25G packets are receiving or transmitting.
1G/10G port is linked.
1G/10G packets are receiving or transmitting.
Port is not linked.
On
On
Blinking
Blinking
SFP28

Installation Requirements
Phillips screwdriver.
Before you begin the installation, make sure that you have the following:
Site Environment:
Standard-sized, 19" wide rack with a minimum of 1U height available.
Category 5e or higher RJ-45 Ethernet cables for connecting network devices.
Do not install the equipment in a dusty environment.
The installation site must be free from leaking or dripping water, heavy dew, and humidity.
Do not operate it in an area that exceeds an ambient temperature of 45°C.
The installation site must be well ventilated. Ensure that there is adequate air ow around the
switch.
Be sure that the switch is level and stable to avoid any hazardous conditions.
2 Hot-swappable Power SuppliesGrounding Points 4 Fans
GND
PS2
PS1
S5800-8TF12S
Back Panels
S5850-24T16B/S5850-24T16S
4 Hot-swappable Fans 2 Hot-swappable Power Supplies
FAN4 FAN1 PS2 PS1
Grounding Point
100-240Vac
50-60HZ 3-1.5A
100-240Vac
50-60HZ 3-1.5A
100-240Vac
50-60HZ 3-1.5A
100-240Vac
50-60HZ 3-1.5A
S5850-24T16S
ID
SYS
ETH
CON
10/100/1000 BASE-T
12345678910 11 12 13 14 15 16 17 18 19 20 21 22

10G
25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
Rack Mounting
1. Secure the mounting brackets to the two sides of the switch with eight M4 screws.
Mounting the switch
Desk Mounting
1. Attach four rubber pads to the bottom.
2. Place the chassis on the desk.
12345678910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
ETH
CON
10/100/1000BASE-T 10G
ID
SYS
S5850-24T16S
S5850-24T16S
ID
SYS
ETH
CON
10/100/1000 BASE-T
12345678910 11

Grounding the Switch
1. Connect one end of the grounding cable to a proper earth ground, such as the rack in which the
switch is mounted.
2. Secure the grounding lug to the grounding point on the switch back panel with the washers and
screws.
CAUTION: The earth connection must not be removed unless all supply connections have
been disconnected.
FAN4
2. Attach the switch to the rack using four M6 screws and cage nuts.
10G
15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40

Connecting the RJ45 Ports
1. Connect an Ethernet cable to the RJ45 port of a computer, printer, network storage, or other
network devices.
2. Connect the other end of the Ethernet cable to the RJ45 port of the switch.
S5850-24T16S
ID
SYS
ETH
CON
10/100/1000 BASE-T
12345678910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
FAN1
1. Plug the AC power cord into the power port on the back of the switch.
2. Connect the other end of the power cord to an AC power source.
Connecting the Power
WARNING: Do not install power cable while the power is on.

10G
26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
Connecting the Console Port
1. Insert the RJ45 connector of the console cable into the RJ45 console port on the front of the switch.
2. Connect the other end of the console cable to the RS-232 serial port on the computer.
S5850-24T16S
ID
SYS
ETH
CON
10/100/1000 BASE-T
12345678910 11 12 13
Connecting the SFP+ Ports
1. Plug the compatible SFP+/ SFP transceiver into the SFP+ port.
2. Connect a ber optic cable to the ber transceiver. Then connect the other end of the cable to
another ber device.
18
17
16
15 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40

10G
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
Connecting the ETH Port
1. Connect one end of a standard RJ45 Ethernet cable to a computer.
2. Connect the other end of the cable to the ETH port on the front of the switch.
S5850-24T16S
ID
SYS
ETH
CON
10/100/1000 BASE-T
12345678910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Conguring the Switch
Step 1: Connect the computer to the Management port of the switch using the network cable.
Step 2: Set the IP address of the computer to 192.168.1.x ("x" is any number from 2 to 254.).
Set the subnet mask of the computer to 255.255.255.0
Conguring the Switch Using the Web-based Interface
?x
OK Cancel
General
IP address:
Subnet mask:
Default gateway:
You can get IP settings assigned automatically if your network
supports this capability. Otherwise, you need to ask your network
administrator for the appropriate IP settings.
Internet Protocol Version 4(TCP/IPv4) Properties
Use the following IP address:
Obtain an IP address automatically
Preferred DNS server:
Alternate DNS server:
Validate settings upon exit Advanced...
. . . 21168192
0255
255255
. . .
. . .
. . .
. . .
Obtain DNS server address automatically
Use the following DNS server addresses:

10G
25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
Step 3: Open a browser, type http://192.168.1.1, and enter the default username and password,
admin/admin.
Step 4: Click Sign in to display the web-based conguration page.
Conguring the Switch Using the Console Port
Step 1: Connect a computer to the switch's console port using the supplied console cable.
Step 2: Start the terminal simulation software such as HyperTerminal on the computer.
Step 3: Set the parameters of the HyperTerminal: 115200 bits per second, 8 data bits, no parity, 1 stop
bit and no ow control.
Step 4: Enter the default username and password, admin/admin.
x
Quick Connect
Protocol: Serial
Flow Control
DTR/DSR
RTS/CTS
XON/XOFF
Save sessionShow quick connect on startup
Open in a tab
Connect Cancel
COM3
115200
8
None
1
Port:
Baud rate:
Data bits:
Parity:
Stop bits:
Name of pipe:

Troubleshooting
Power LED Working Abnormally
1. Check the power cable connections at the switch and the power source.
2. Make sure the power cord used matches the voltage and frequency of your local power.
1. Make sure the power supply is normal and the console cable is properly connected.
2. Check if the console cable is the right type.
3. Check if the control cable driver is properly installed on the computer.
4. Ensure the parameters of the HyperTerminal are correct.
HyperTerminal Displaying Abnormally
1. Check every port LED on the switch and make sure the Ethernet cable is connected properly.
2. Try another port on the switch and make sure the Ethernet cable is suitable and works normally.
3. Power o the switch and, after a while, power it on again.
4. Make sure the IP address of your PC is set within the subnet of the switch.
5. If you still cannot access the conguration page, please restore the switch to its factory defaults.
Then the IP address of your PC should be set as 192.168.1.x ("x" is any number from 2 to 254) and
Subnet Mask as 255.255.255.0.
Accessing the Web-based Conguration Page Unsuccessfully
Support and Other Resources
Download
Help Center
Contact Us
https://www.fs.com/download.html
https://www.fs.com/service/help_center.html
https://www.fs.com/contact_us.html

Product Warranty
FS ensures our customers that any damage or faulty items due to our workmanship, we will oer a
free return within 30 Days from the day you receive your goods. This excludes any custom made
items or tailored solutions.
Warranty: S58 Series Switches enjoy 5 years limited warranty against defect in
materials or workmanship. For more details about warranty, please check at
https://www.fs.com/policies/warranty.html
Return: If you want to return item(s), information on how to return can be found at
https://www.fs.com/policies/day_return_policy.html
5

Copyright © 2020 FS.COM All Rights Reserved.
Q.C. PASSED
This manual suits for next models
3
Table of contents
Other FS Switch manuals

FS
FS S3900 Series User manual

FS
FS S5850-24XMG-U Series User manual

FS
FS S3700-24T4F User manual

FS
FS PoE+ Series User manual

FS
FS S5850-24XMG User manual

FS
FS S3700-24T4F Instruction Manual

FS
FS S3700-24T4F Instruction Manual

FS
FS S3410 Series User manual

FS
FS S3950-4T12S-R User manual

FS
FS S5500-48T8SP User manual