FS S5850-24S2Q-DC User manual

COMMUTATEURS DE ROUTAGE L2/L3 GÉR
MANAGED L2/L3 ROUTING SWITCH
MANAGED L2/L3 ROUTING SWITCH
V1.0
Quick Start Guide
Quick-Start Anleitung
Guide de Démarrage Rapide
S5850-24S2Q-DC

S5850-24S2Q-DC
1 2 345 6 78 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25 26
40G
40GEBreakout 123 4
ID SYS
CON
ETH
Introduction
S5850-24S2Q-DC
Terminal Block Connector x2
Grounding Cable x1 Rubber Pad x4 M4 Screw x8
Mounting Bracket x2 Spring Clip x2
Console Cable x1 Cat5e Cable x1
Accessories
Thank you for choosing S5850-24S2Q-DC switch. This guide is designed to familiarize you with the
layout of the switch and describe how to deploy the switch in your network.

S5850-24S2Q-DC
1 2 345 6 78910 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
40G
40GEBreakout 123 4
ID SYS
CON
ETH
1 2 345 6 78910 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
40G
40GEBreakout 123 4
ID SYS
CON
ETH
S5850-24S2Q-DC
Hardware Overview
Front Panel Ports
Front Panel LEDs
QSFP+
SFP+
USB
CON
QSFP+
SFP+
ETH 40G Breakout LED
SYS
Ports Description
SFP+
QSFP+
CON
SFP+ ports for 1/10G transceivers
QSFP+ ports for 40G or 4x 10G connection
An RJ45 console port for serial management
ETH
USB
An Ethernet management port
A USB management port for software and conguration backup
and oine software upgrade
ID
SYS
ID indication function enable.Blue
Green
O
O
Amber
ID indication function disable.
The System is normally running
The system occurs alarm or error.
No power or no system runs or runs abnormally.
ETH
Green
Blinking Green
O
Port is linked.
Port is receiving or transmitting packets.
Port is not linked.
LEDs Status Description
ETH
ID

+
NULL
-
-48V- -60V,6A
+
NULL
-
-48V- -60V,6A
Back Panel
Grounding Point 3 Fixed Fans
Breakout
One or more 40G ports are breakout.Loop Blinking
O None of the 40G port is breakout.
QSFP+
SFP+
Green
Blinking Green
Blinking Green
O
O
Amber
Blinking Amber
Blinking Amber
Green
Amber
10G port is linked.
The SFP+ port is transmitting or receiving packets at 10G.
1G port is linked.
The SFP+ port is transmitting or receiving packets at 1G.
Port is not linked.
40G port is linked.
The QSFP+ port is transmitting or receiving packets at 40G.
10G port is linked.
The QSFP+ port is transmitting or receiving packets at 10G.
Port is not linked.
LEDs Status Description
2 Hot-swappable Power Supplies

Site Environment:
Installation Requirements
Do not operate it in an area that exceeds an ambient temperature of 45ºC.
The installation site must be well ventilated. Ensure that there is adequate air ow around the
switch.
Be sure that the switch is level and stable to avoid any hazardous conditions.
Do not install the equipment in a dusty environment.
The installation site must be free from leaking or dripping water, heavy dew, and humidity.
Ensure rack and working platforms are well earthed.
Before you begin the installation, make sure that you have the following:
Phillips screwdriver.
M6 Screws.
Standard-sized, 19" wide rack with a minimum of 1U height available.
Category 5e or higher RJ-45 Ethernet cables for connecting the network devices.
Mounting the Switch
Desk Mounting
1. Attach four rubber pads to the bottom.
2. Place the chassis on a desk.
S5850-24S2Q
ID SYS
CON
ETH
S5850-24S2Q
1 2 345
ID SYS
CON
ETH

Rack Mounting
1. Secure the mounting brackets to the two sides of the switch with eight M4 screws.
1 2 345 6 78910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25 26
40G
40GEBreakout 123 4
2. Attach the switch to the rack using four M6 screws and cage nuts.
5 6 78910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25 26
40G
40GE Breakout 123 4

S5850-24S2Q
ID SYS
CON
ETH
S5850-24S2Q
ID SYS
CON
ETH
1. Connect one end of the grounding cable to a proper earth ground, such as the rack in which the
switch is mounted.
2. Secure the grounding lug to the grounding point on the switch back panel with the washer and
screws.
Grounding the Switch
CAUTION: The earth connection must not be removed unless all supply connections
have been disconnected.
Connecting the Power
+
NULL
-
-48V- -60V,6A
The front panel of the power supply indicates a DC inlet power socket and consists of one terminal
block connector within 3 contacts. Please follow the steps below to insert the power wire.
1.Insert positive/negative DC power wires into Contacts + and -
2.Tighten the wire-clamp screws to prevent the wires from loosening.
NO.
1
2
3
Name
+
-
NULL
Description
Positive
Negative
Null
+NULL
-

CAUTION: Laser beams will cause eye damage. Do not look into bores of optical modules
or optical bers without eye protection.
First install SFP+ transceivers and then connect ber optic cabling to the transceiver ports, or directly
connect DAC cables to the SFP+ slots.
Connecting the SFP+ Ports
1 2 345 6 78910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25 26
40G
40GE Breakout 123 4
First install QSFP+ transceivers and then connect ber optic cabling to the transceiver ports, or
connect DAC cables to the QSFP+ slots.
Connecting the QSFP+ Ports
1 2 345 6 78910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25 26
40G
40GE Breakout 123 4

ID SYS
CON
ETH
1 2 345 6 7
ID SYS
CON
ETH
Connecting the Management Ports
1. Insert the RJ45 connector of the console cable into the RJ45 console port on the front of the switch.
2. Connect the other end of the console cable to the RS-232 serial port on the computer.
1. Connect one end of a standard RJ45 Ethernet cable to a computer.
2. Connect the other end of the cable to the ETH port on the front of the switch.
Connecting the Console Port
Connecting the ETH Port

1 2 345 6 78910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25 26
40G
40GE Breakout 123 4
8910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25 26
40G
40GE Breakout 123 4
1 2 345 6 789
ID SYS
CON
ETH
USB
Conguring the Switch
Insert the Universal Serial Bus (USB) ash disk to the USB port for software and conguration backup
and oine software upgrade.
Step1: Connect the computer to the Management port of the switch using the network cable.
Step 2: Set the IP address of the computer to 192.168.1.x. ("x" is any number from 2 to 254.). Set the
subnet mask of the computer to 255.255.255.0.
Connecting the USB Port
Conguring the Switch Using the Web-based Interface
?x
OK Cancel
General
IP address:
Subnet mask:
Default gateway:
You can get IP settings assigned automatically if your network
supports this capability. Otherwise, you need to ask your network
administrator for the appropriate IP settings.
Internet Protocol Version 4(TCP/IPv4) Properties
Use the following IP address:
Obtain an IP address automatically
Preferred DNS server:
Alternate DNS server:
Validate settings upon exit Advanced...
. . . 21168192
0255
255255
. . .
. . .
. . .
. . .
Obtain DNS server address automatically
Use the following DNS server addresses:

910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25 26
40G
40GE Breakout 123 4
Step 3: Open a browser, type http://192.168.1.1, and enter the default username and password,
admin/admin.
Step 4: Click sign in to display the web-based conguration page.
Step 1: Connect a computer to the switch's console port using the supplied console cable.
Step 2: Start the terminal simulation software such as HyperTerminal on the computer.
Step 3: Set the parameters of the HyperTerminal: 115200 bits per second, 8 data bits, no parity, 1 stop
bit and no ow control.
Step 4: Enter the default username and password, admin/admin.
Conguring the Switch Using the Console Port
x
Quick Connect
Protocol: Serial
Flow Control
DTR/DSR
RTS/CTS
XON/XOFF
Save sessionShow quick connect on startup
Open in a tab
Connect Cancel
COM3
115200
8
None
1
Port:
Baud rate:
Data bits:
Parity:
Stop bits:
Name of pipe:

Troubleshooting
After loading fails, the system will keep running in the original version. At this time, users should
re-check if physical port connections are good rstly. If some ports are not connected, then re-connect
them to ensure that physical connections are correct, and begin re-loading. If physical connections
are correct, then check the loading process information displayed on the super terminal to verify if
there are input errors. If there are input errors, correct them and re-load.
Loading Failure Troubleshooting
If system password is lost or forgotten, the following method can be used to reset the password:
1. Connect the console port of the switch to the computer through the console cable.
2. Press ctrl + b to enter the Uboot mode.
3. Start the system with an empty conguration le with no password.
Bootrom#boot_ash_nopass
Bootrom#Do you want to revert to the default cong le?[Y|N|E]:
User Password Lost Troubleshooting
Conguration System Troubleshooting
1. Make sure the power supply is normal and the console cable is properly connected.
2. Check if the console cable is the right type.
3. Check if the control cable driver is properly installed on the computer.
4. Ensure the parameters of the HyperTerminal are correct.
NOTE: Forgetting your username and password and restoring them through console port
may cause conguration loss and business interruption. Please remember your username
and password.

Support and Other Resources
Download
Help Center
Contact Us
https://www.fs.com/products_support.html
https://www.fs.com/service/fs_support.html
https://www.fs.com/contact_us.html
Product Warranty
FS ensures our customers that any damage or faulty items due to our workmanship, we will oer a
free return within 30 Days from the day you receive your goods. This excludes any custom made
items or tailored solutions.
Warranty: S5850-24S2Q-DC Switch enjoys 5 years limited warranty against defect in
materials or workmanship. For more details about warranty, please check at
https://www.fs.com/policies/warranty.html
Return: If you want to return item(s), information on how to return can be found at
https://www.fs.com/policies/day_return_policy.html
5

S5850-24S2Q-DC
1 2 345 6 78 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25 26
40G
40GEBreakout 123 4
ID SYS
CON
ETH
Introduction
S5850-24S2Q-DC
Connecteur du Bloc Terminal x2
Câble de Mise à la Terre x1 Coussin en Caoutchouc x4 Vis M4 x8
Support de Montage x2 Clip à Ressort x2
Câble de Console x1 Câble Cat5e x1
Accessories
Merci d'avoir choisi le switch S5850-24S2Q-DC. Ce guide est conçu pour que vous puissiez vous familiariser
avec la conguration du switch et vous indiquer comment procéder à son déploiement.

S5850-24S2Q-DC
1 2 345 6 78910 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
40G
40GEBreakout 123 4
ID SYS
CON
ETH
1 2 345 6 78910 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
40G
40GEBreakout 123 4
ID SYS
CON
ETH
S5850-24S2Q-DC
Aperçu du Matériel
Ports du Panneau Frontal
Indicateurs LED du Panneau Frontal
QSFP+
SFP+
USBETH
CON
QSFP+
SFP+
ETH LED 40G Breakout 40G
ID SYS
Ports Description
SFP+
QSFP+
CON
Ports SFP+ pour modules 1/10G
Ports QSFP+ pour connexion 40G ou 4x 10G
Port console RJ45 pour la gestion série
ETH
USB
Port de gestion Ethernet
Port de gestion USB pour la sauvegarde du logiciel, et la
conguration et la mise à jour du logiciel en ligne.
ID
SYS
Activation de la fonction d'indication de l'IDBleu
Vert
Éteint
Éteint
Jaune
Désactivation de la fonction d'indication de l'ID
Le système fonctionne normalement
Le système présente une alarme ou une erreur
L'alimentation est coupée ou le système ne fonctionne
pas ou fonctionne anormalement
ETH
Vert
Vert Clignotant
Le port est relié
Le port reçoit ou transmet des paquets
Indicateur
LED Statut Description

+
NULL
-
-48V- -60V,6A
+
NULL
-
-48V- -60V,6A
Panneau Arrière
Point de
Mise à la Terre
3 Ventilateurs Fixes
ETH Éteint Le port n'est pas relié
Breakout
Un ou plusieurs ports 40G sont en breakout
Clignotement en
Boucle
Éteint Aucun des ports 40G n'est en breakout
Indicateur
LED Statut Description
QSFP+
SFP+
Vert
Vert Clignotant
Vert Clignotant
Éteint
Éteint
Jaune
Jaune Clignotant
Jaune Clignotant
Vert
Jaune
Le port 10G est relié
Le port SFP+ transmet ou reçoit des paquets à 10G
Le port 1G est relié
Le port SFP+ transmet ou reçoit des paquets à 1G
Le port n'est pas relié
Le port 40G est relié
Le port QSFP+ transmet ou reçoit des données à 40G
Le port 10G est relié
Le port QSFP+ transmet ou reçoit des données à 10G
Le port n'est pas relié
2 Alimentations Électriques Remplaçables à Chaud

Site de l'installation :
Exigences d'Installation
Ne pas installer l'appareil dans un endroit où la température ambiante dépasse 45°C.
Le site d'installation doit être bien ventilé. Veillez à ce qu'il y ait une circulation d'air susante autour
du switch.
Assurez-vous que le switch est à niveau et stable pour éviter tout risque.
Ne pas installer l'équipement dans un environnement poussiéreux.
Le site d'installation doit être exempt de fuites d'eau et d'humidité.
Assurez-vous que le rack et les plateformes de travail sont bien mis à la terre.
Avant de commencer l'installation, assurez-vous que vous disposez des
éléments suivants :
Tournevis phillips.
Vis M6
Rack de taille standard, 19" de large, avec une hauteur minimum de 1U.
Câbles Ethernet RJ-45 de catégorie 5e ou supérieure pour la connexion des périphériques réseau.
Installation du Switch
Montage sur Support
1. Fixez quatre coussins en caoutchouc à la base.
2. Placez le châssis sur le support.
S5850-24S2Q
ID SYS
CON
ETH
S5850-24S2Q
1 2 345
ID SYS
CON
ETH

Montage sur Rack
1. Fixez les supports de montage aux deux côtés du switch à l'aide de huit vis M4.
1 2 345 6 78910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25 26
40G
40GEBreakout 123 4
2. Fixez le switch au rack à l'aide de quatre vis M6 et d'écrous à cage.
678910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25 26
40G
40GE Breakout 123 4

S5850-24S2Q
ID SYS
CON
ETH
S5850-24S2Q
ID SYS
CON
ETH
1. Connectez une extrémité du câble de mise à la terre à une mise à la terre appropriée, telle que
le rack dans lequel le switch est monté.
2. Fixez la che de mise à la terre au panneau arrière de l'interrupteur à l'aide de la rondelle et des vis.
Mise à la Terre du Switch
ATTENTION : La connexion de terre ne doit pas être retirée avant que toutes les
connexions d'alimentation aient été déconnectées.
Connexion de l'Alimentation
+
NULL
-
-48V- -60V,6A
Le panneau avant de l'alimentation présente une prise d'alimentation CC et se compose d'un connecteur
à bornier à 3 contacts. Veuillez suivre les étapes ci-dessous pour insérer le l d'alimentation.
1.Insérer les ls d'alimentation CC positifs/négatifs dans les contacts + et -.
2.Serrez les vis de xation des ls pour éviter qu'ils ne se détachent.
NO.
1
2
3
Name
+
-
NULL
Description
Positive
Negative
Null
+NULL
-

ATTENTION : Les faisceaux laser peuvent causer des lésions oculaires. Ne pas regarder
directement dans les orices des modules ou des bres optiques sans protection oculaire.
Installez d'abord les modules SFP+, puis connectez les câbles en bre optique aux ports des
modules, ou connectez directement les câbles DAC aux emplacements SFP+.
Connexion des Ports SFP+
1 2 345 6 78910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25 26
40G
40GE Breakout 123 4
Connexion des Ports QSFP+
1 2 345 6 78910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25 26
40G
40GE Breakout 123 4
Table of contents
Languages:
Other FS Switch manuals
Popular Switch manuals by other brands

TP-Link
TP-Link T3700G-28TQ Cli reference guide

Moxa Technologies
Moxa Technologies TN-5500A Series Quick installation guide

Cisco
Cisco Catalyst 2960 Series Hardware installation guide

HP
HP StorageWorks 2/32 - SAN Switch installation guide

Intellinet
Intellinet IPS-6GM02-60W user manual

Extron electronics
Extron electronics SW2 VGArs user manual