FS S3900 Series User manual

S3900 SERIES MANAGED L2+ GIGABIT
SWITCHES
MANAGED-L2+-GIGABIT-SWITCH DER S3900-SERIE
SWITCHS MANAGEABLES L2+ GIGABIT DE LA SÉRIE S3900
Quick Start Guide V1.0
Quick-Start Anleitung
Guide de Démarrage Rapide

Introduction
Thank you for choosing S3900 Series Stackable Managed Switches. This guide is designed to familiarize
you with the layout of the switch and describes how to deploy the switch in your network.
Accessories
S3900-24F4S-R
S3900-48T6S-R
S3900-24T4S-R
Power Cord x 2
S3900-24T4S-R
Rubber Pad x 4 M4 Screw x 6
Grounding Cable x 1
Console Cable x 1 Mounting Bracket x 2
1
EN

NOTE: S3900 series switches have dust plugs delivered with them. Keep the dust plugs
properly and use them to protect idle optical ports.
S3900-24F4S-R
Power Cord x 2
Rubber Pad x 4 M4 Screw x 8
Grounding Cable x 1
Console Cable x 1 Mounting Bracket x 2
S3900-48T6S-R
Power Cord x 2
Rubber Pad x 4 M4 Screw x 8
Grounding Cable x 1
Console Cable x 1 Mounting Bracket x 2
2
EN

Hardware Overview
Front Panel Ports
S3900-24T4S-R
S3900-24F4S-R
S3900-48T6S-R
CONSOLE SFP+
RJ45
CONSOLE
CONSOLE
SFP
COMBO
RJ45
SFP+
SFP+
Ports Description
10/100/1000BASE-T ports for Ethernet connection
SFP ports for 1G connection
SFP+ ports for 1/10G connection
RJ45
SFP
SFP+
CONSOLE
COMBO
An RJ45 console port for serial management
One RJ45 port and one SFP slot, with one port active at a time
3
EN

Front Panel LEDS
S3900-24T4S-R
SYS Link/Act
PWR
S3900-48T6S-R
RJ45
SFP+
SYS
PWR
S3900-24F4S-R
SYS Link/Act
PWR
Switch is powered on.
System is working properly.
System is started normally.
System is not working properly.
Data is being transmitted or received.
no signal transmission.
Data is being transmitted or received.
No device is connected to the corresponding port.
LEDs DescriptionStatus
PWR Green
SYS
Green
Blinking Green
O
Link/Act
Green
O
RJ45/SFP+
Green
O
4
EN

Back Panels
Only professionals are allowed to install or replace the switch.
Before you begin the installation, make sure that you have the following:
Installation Requirements
Screwdriver
Static-proof wristband
Ethernet cable
Other Ethernet terminal devices
Control terminal
Power switch ON means the power is switched on, while OFF means the power is cut o.
Button Description
S3900-24T4S-R
Dual Power Supplies
S3900-24F4S-R / S3900-48T6S-R
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Grounding Point
Power Switch
Dual Power Supplies
Grounding Point
Power Switch
5
EN

Site Environment:
Do not operate it in an area that exceeds an ambient temperature of 50°C.
The installation site must be free from leaking or dripping water, heavy dew, and humidity.
Ensure rack and working platforms are well earthed.
The installation site must be well ventilated. Ensure that there is adequate air ow around the
switch.
Be sure that the switch is level and stable to avoid any hazardous conditions.
Do not install the equipment in a dusty environment.
Desk Mounting
1. Attach four rubber pads to the bottom.
2. Place the chassis on a desk.
Mounting the Switch
NOTE: Do not put things weighing 4.5 kg or over 4.5 kg on the top of the switch.
6
EN

Rack Mounting
1. Secure the mounting brackets to the two sides of the switch with M4 screws.
2. Attach the switch to the rack using M6 screws and cage nuts.
ON
OFF
7
EN

ON
OFF
ON
OFF
1. Connect one end of the grounding cable to a proper earth ground, such as the rack in which the
switch is mounted.
2. Secure the grounding lug to the grounding point on the switch back panel with the washers and
screws.
Grounding the Switch
CAUTION: The earth connection must not be removed unless all supply connections have
been disconnected.
8
EN

ON
OFF
Connecting the Power
WARNING: Do not install power cable while the power is on.
Connecting the RJ45 Ports
1. Plug the AC power cord into the power port on the back of the switch.
2. Connect the other end of the power cord to an AC power source.
1. Connect an Ethernet cable to the RJ45 port of a computer, printer, network storage, or other
network devices.
2. Connect the other end of the Ethernet cable to the RJ45 port of the switch.
9
EN

WARNING: Laser beams will cause eye damage. Do not look into bores of optical modules
or optical bers without eye protection.
Connecting the SFP+
1. Plug the compatible SFP+/SFP transceiver into the SFP+ port.
2. Connect a ber optic cable to the ber transceiver. Then connect the other end of the cable to
another ber device.
10
EN

1. Insert the RJ45 connector into the RJ45 console port on the front of the switch.
2. Connect the DB9 female connector of the console cable to RS-232 serial port on the computer.
Connecting the Console Port
Stacking the S3900 Series Switches
S3900-24T4S-R&S3900-24F4S-R support 8 units hybrid-stacking together. S3900-48T6S-R supports 6
units stacking between same models. Switches can be physically stacked using optical ber cables
connected to SFP+ transceivers, or 10G Direct Attach Cables (DAC). All SFP+ ports on the switch can be
used for physical stacking.
11
EN

Configuring the Switch
Conguring the Switch Using the Web-based Interface
Step 3: Open a browser, type http://192.168.1.1, and enter the default username and password.
Step 1: Connect your computer to any Ethernet port of the switch using the network cable.
Step 2: Set the IP address of the computer to 192.168.1.x. (“x” is any number from 2 to 254.)
Step 4: Click Login to display the web-based conguration page.
x
Cancel
General
IP address:
Subnet mask:
Default ga t e w ay :
You can get IP settings assigned automatically if your net w o r k
supports this capabil i t y . O t herwise, y o u need t o a sk your net w o r k
adminis t r a t o r f o r the appropr i a t e IP settings .
In te rnet Protoc ol Vers io n 4 ( TCP/IP v4) Properties
Use the following IP address:
Obtain an IP address automatically
Preferred DNS server:
Alternate DNS server:
Validate settings upon exit A d v anc e d ...
. . .21168192
0255
255255
. . .
. . .
. . .
. . .
Obtain DNSserv er a ddres s automatically
Use the following DNS se rv er addresses:
OK
12
EN

Conguring the Switch Using the Console Port
Step 1: Connect a computer to the switch's console port using the supplied console cable.
Step 2: Start the terminal simulation software such as HyperTerminal on the computer.
Step 3: Set the parameters of the HyperTerminal: 115200 bits per second, 8 data bits, no parity,
1 stop bit and no ow control.
x
Quick Connect
Protocol:
The port may be manually entered or selected from the list.
Serial
Flow Control
DTR/DSR
RTS/CTS
XON/XOFF
Save sessionShow quick connect on startup
Open in a tab
Connect
Cancel
COM3
115200
8
None
1
Port:
Baud rate:
Data bits:
Parity:
Stop bits:
Name of pipe:
Troubleshooting
In the case of compatible cables and transceivers, the port cannot be up, please try to modify the
port mode to adapt or force the port speed to 1G/10G.
1/10G Port is not Working
1. Test network connectivity through ping.
2. If the network is reachable, try restarting the switch.
3. Check if the corresponding service is enabled.
Connecting the Switch Remotely Unsuccessfully
13
EN

1. Ensure the switch ports are in the no shutdown state.
2. Check if the switch can read the DDM information.
3. Check if the port speed setting is correct.
4. Try looping the switch cable.
The Port is not Working, the LED Indicator is O
Support and Other Resources
Download
Help Center
Contact Us
https://www.fs.com/download.html
https://www.fs.com/service/help_center.html
https://www.fs.com/contact_us.html
Product Warranty
FS ensures our customers that any damage or faulty items due to our workmanship, we will oer a
free return within 30 Days from the day you receive your goods. This excludes any custom made
items or tailored solutions.
Warranty: S3900 Series Switches enjoy 4 years limited warranty against defect
in materials or workmanship. For more details about warranty, please check at
https://www.fs.com/policies/warranty.html
Return: If you want to return item(s), information on how to return can be found at
https://www.fs.com/policies/day_return_policy.html
4
14
EN

Einführung
Vielen Dank, dass Sie sich für die Stackable Managed Switches der S3900-Serie entschieden haben.
Diese Anleitung soll Sie mit dem Layout des Switches vertraut machen und beschreibt, wie Sie den
Switch in Ihrem Netzwerk einsetzen.
S3900-24F4S-R
S3900-48T6S-R
S3900-24T4S-R
Netzkabel x 2
Zubehör
Gummipad x 4 M4 Schraube x 6
Erdungskabel x 1
Konsolenkabel x 1 Montagehalterung x 2
S3900-24T4S-R
15
DE

HINWEIS: Bei den Switches der S3900-Serie werden Staubschutzkappen mitgeliefert.
Bewahren Sie bitte die Staubschutzkappen ordnungsgemäß auf und verwenden Sie sie
zum Schutz ungenutzter optischer Ports.
S3900-24F4S-R
Netzkabel x 2
Gummipad x 4 M4-Schraube x 8
Erdungskabel x 1
Konsolenkabel x 1 Montagehalterung x 2
S3900-48T6S-R
Netzkabel x 2
Gummipad x 4 M4-Schraube x 8
Erdungskabel x 1
Konsolenkabel x1 Montagehalterung x 2
16
DE

Hardware-Übersicht
Ports an der Vorderseite
S3900-24T4S-R
S3900-24F4S-R
S3900-48T6S-R
CONSOLE SFP+
RJ45
CONSOLE
CONSOLE
SFP
COMBO
RJ45
SFP+
SFP+
Ports Beschreibung
10/100/1000BASE-T Ports für Ethernet-Anschluss
SFP+-Ports für 1G-Anschluss
SFP+-Ports für 1/10G-Anschluss
RJ45
SFP
SFP+
CONSOLE
COMBO
RJ45 Console-Port für die serielle Verwaltung
Ein RJ45-Port und ein SFP-Steckplatz, wobei jeweils ein Port aktiv ist
17
DE

LEDs an der Vorderseite
S3900-24T4S-R
SYS Link/Act
PWR
S3900-48T6S-R
RJ45
SFP+
SYS
PWR
S3900-24F4S-R
SYS Link/Act
PWR
Switch ist eingeschaltet.
Das System funktioniert ordnungsgemäß.
Das System wird normal gestartet.
Das System funktioniert nicht ordnungsgemäß.
Es werden Daten gesendet oder empfangen.
Keine Signalübertragung.
Es werden Daten übertragen oder empfangen.
Es ist kein Gerät an den entsprechenden Port angeschlossen.
LEDs BeschreibungStatus
PWR Grün
SYS
Grün
Blinkend Grün
Aus
Link/Act
Grün
Aus
RJ45/SFP+
Grün
Aus
18
DE

Rückseite
Die Installation oder der Austausch des Switches darf nur von Fachleuten
vorgenommen werden.
Bevor Sie mit der Installation beginnen, vergewissern Sie sich, dass Sie
über die folgenden Utensilien verfügen:
Installationsvoraussetzungen
Schraubenzieher
Antistatik-Armband
Ethernet-Kabel
Andere Ethernet-Endgeräte
Steuerterminal
Power switch ON bedeutet, dass der Strom eingeschaltet ist, während OFF bedeutet, dass der
Strom abgeschaltet ist.
Taste Beschreibung
S3900-24T4S-R
Duale Stromversorgung
S3900-24F4S-R / S3900-48T6S-R
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Erdungspunkt
Netzschalter
Duale Stromversorgung
Erdungspunkt
Netzschalter
19
DE
Other manuals for S3900 Series
3
This manual suits for next models
3
Table of contents
Languages:
Other FS Switch manuals
Popular Switch manuals by other brands

nedis
nedis WIFIPS10 Series quick start guide

D-Link
D-Link DUB-H4 - Hub - USB Quick installation guide

ANTAIRA
ANTAIRA LNP-0800 Series user manual

Enterasys
Enterasys RoamAbout RBT-8110 installation guide

Pepperl+Fuchs
Pepperl+Fuchs RocketLinx ICRL2-U-8RJ45-DIN manual

NetScreen Technologies
NetScreen Technologies 5GT Getting started