1. Specifications
Type
Wall mounted
Inverter heat pump
Model name ASHG18KLCA ASHG24KLCA
Power supply 230 V ~ 50 Hz
Available voltage range 198—264 V
Capacity
Cooling
Rated kW 5.20 7.10
Btu/h 17,700 24,200
Min.—Max. kW 0.9—5.5 0.9—7.7
Btu/h 3,000—18,700 3,000—26,200
Heating
Rated kW 6.30 8.00
Btu/h 21,400 27,200
Min.—Max. kW 0.6—7.6 0.9—9.0
Btu/h 2,000—22,500 3,000—30,700
Input power
Cooling Rated
kW
1.685 2.42
Min.—Max. 0.14—2.09 0.18—2.74
Heating Rated 1.800 2.225
Min.—Max. 0.10—1.93 0.15—2.66
Fan
HIGH
W
32 57
MED 25 34
LOW 16 17
QUIET 10 10
Current Cooling Rated A 7.5 10.9
Heating 8.0 10.4
EER Cooling kW/kW 3.09 2.93
COP Heating 3.50 3.60
Sensible capacity Cooling kW 3.93 4.92
Power factor Cooling %98.0
Heating 98.0
Moisture removal L/h (pints/h) 1.9 (3.3) 3.1 (5.5)
Maximum operating current *1 Cooling A9.5 13.5
Heating 13.5 17.5
Fan
Airflow rate
Cooling
HIGH
m3/h
865 1,040
MED 780 880
LOW 665 685
QUIET 555 555
Heating
HIGH 995 1,040
MED 810 800
LOW 700 680
QUIET 590 580
Type × Q'ty Cross flow fan × 1
Motor output W 61
Sound pressure level *2
Cooling
HIGH
dB (A)
47 51
MED 44 45
LOW 40 38
QUIET 35 33
Heating
HIGH 50 52
MED 45 45
LOW 41 41
QUIET 37 37
Heat exchanger type
Dimensions (H × W × D) mm
Main: 384 × 630 × 20.0
Sub: 126 × 630 × 13.30
Main: 384 × 630 × 20.0
Sub1: 84 × 630 × 13.30
Sub2: 126 × 630 × 13.30
Fin pitch Man: 1.1, Sub: 1.4 Man: 1.1, Sub1: 1.4, Sub2: 1.4
Rows × Stages Main: 2 × 24, Sub: 1 × 6 Main: 2 × 24, Sub1: 1 × 4, Sub2: 1 × 6
Pipe type Copper tube
Fin type Aluminum
Enclosure
Material Polystyrene
Color White
Approximate color of Munsell N 9.25/
Dimensions
(H × W × D)
Net mm 293 × 790 × 249
Gross 320 × 840 × 375
Weight Net kg 9.5 10.0
Gross 12.0 12.5
Connection pipe Size Liquid mm (in) Ø 6.35 (Ø 1/4) Ø 6.35 (Ø 1/4)
Gas Ø 9.52 (Ø 3/8) Ø 12.70 (Ø 1/2)
Method Flare
Drain hose Material PP+HDPE
Size mm Ø 13.8 (I.D.), Ø 15.8 to Ø 16.7 (O.D.)
Operation range Cooling °C 18 to 32
%RH 80 or less
Heating °C 16 to 30
Remote controller type Wireless
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB
– Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB
– Pipe length: 5 m, Height difference: 0 m (Between outdoor unit and indoor unit)
• Protective function might work when using it outside the operation range.
• *1: Maximum current is maximum value when operated within the operation range.
• *2: Sound pressure level:
– Measured values in manufacturer’s anechoic chamber
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
- 2 - 1. Specifications
WALL MOUNTED
ASHG18, 24KLCA
WALL MOUNTED
ASHG18, 24KLCA