991
SCHEMA ELETTRICO / ELECTRICAL CONNECTIONS
SENSORE FINECORSA CHIUDE
CLOSING LIMIT SWITCH SENSOR
SENSORE FINECORSA APRE
OPENING LIMIT SWITCH SENSOR
Q1 Q2
K3
K1 K2
K5
K4
D14
U2
U1
U3
G:B:D:
Q3
D15
DL7
DL8
START (NO)
SAF.(8K2)
COM
PHOTO (NC)
PED (NO)
COM
STOP/SAF.(8K2)
24Vcc 10W MAX
24Vcc 3W MAX
1 2 3 4 5678 9 10 11
12
1314
15 16 17 18 19
J4
M1
M2
M3
0 Vac
18 Vac
24 Vac
F2-5A
L1
DL2
START
PED
1 2
SW4
ON
OFF
PAUSE SLOW FORCE
AMP
SLOW AMP
FORCE
F3-0.5A
F1-315mA
RX
COM
24Vac
0Vac
+SK
-
SK
SPIA
LAMP
CB24
TRASF
LED
DL1
DL2
DL3
DL4
DL5
PED
START
PHOTO
FCA
FCC
DL7
DL8
SAFETY
STOP-SAFETY
15 16 17 18 19
M3
M
COM
+24Vdc TEST/E. SAV.
MOTOR
MOTOR
+24Vdc
230Vac

SC24
I-UK
3
4
COLLEGAMENTO MOTORE / MOTOR CONNECTION
CAVO NERO / BLACK CABLE
2
COLLEGAMENTO ALIMENTAZIONE / POWER SUPPLY CONNECTION
PHASE
NEUTRAL
230Vac
PHASE
NEUTRAL
INTERRUTTORE DIFFERENZIALE
RESIDUAL-CURRENT DEVICE
INTERRUTTORE MAGNETOTERMICO
OVERCURRENT CIRCUIT BREAKER
CAVO ROSSO / RED CABLE
SL344
CAVO NERO / BLACK CABLE
CAVO ROSSO / RED CABLE
SL844
CAVO NERO / BLACK CABLE
CAVO ROSSO / RED CABLE
SL344
CAVO NERO / BLACK CABLE
CAVO ROSSO / RED CABLE
SL844
0 Vac
18 Vac
24 Vac
CAVO NERO / BLACK CABLE
CAVO ROSSO / RED CABLE
CAVO ARANCIONE/ ORANGE CABLE
1 2 3 4 5678 9 10 11
12
1314
15 16 17 18 19
J4
M1
M2
M3
F2-5A
L1
Q2
D14
TRASF
15 16 17 18 19
M3
15 16 17 18 19
M3
15 16 17 18 19
M3
15 16 17 18 19
M3
3
COLLEGAMENTO TRASFORMATORE/ POWER TRANSFORMER CONNECTION

SC24
I-UK
4
INSTALLAZIONE FINECORSA / END LIMITS INSTALLATION
5
INSTALLAZIONE FINECORSA / END LIMITS INSTALLATION
6
CLOSING
CHIUSURA X2 OPENING
APERTURA X2
STOP
INIZIO RALLENTAMENTO IN CHIUSURA
DECELERATION START IN CLOSING
STOP
INIZIO RALLENTAMENTO IN APERTURA
DECELERATION START IN OPENING
STOP
INIZIO RALLENTAMENTO IN CHIUSURA
DECELERATION START IN CLOSING
STOP
INIZIO RALLENTAMENTO IN APERTURA
DECELERATION START IN OPENING
CLOSING
CHIUSURA X2
OPENING
APERTURA X2

SC24
I-UK
5
START (NO)
SAF.(8K2)
COM
PHOTO (NC)
PED (NO)
COM
STOP/SAF.(8K2)
M2
8 9 10 11
12
1314
4
9
COLLEGAMENTO DISPOSITIVI DI COMANDO / CONTROL DEVICES CONNECTION
4
7
COLLEGAMENTO LAMPEGGIANTE / FLASHING LIGHT CONNECTION
24 Vdc 10W max
DIP SWITCH 3
Ref
on
off
3s on
off
3s
on
off
on
off
ON
3
OFF
ON
3
OFF
M1
COM
24Vac
0Vac
+SK
-
SK
LAMP
1 2 3 4 567
SPIA
START (NO)
SAF.(8K2)
COM
PHOTO (NC)
PED (NO)
COM
STOP/SAF.(8K2)
M2
8 9 10 11
12
1314
4
8
COLLEGAMENTO SPIA DI SEGNALAZIONE / WARNING LIGHT CONNECTION
24Vdc 3W MAX
4
10
8K2
ON
10
OFF DIP SWITCH 10 = OFF
COLLEGAMENTO STOP / STOP CONNECTION
M1
COM
24Vac
0Vac
+SK
-
SK
LAMP
1 2 3 4 567
SPIA

SC24
I-UK
6
12
COLLEGAMENTO FOTOCELLULE CON TEST / PHOTOCELLS CONNECTION WITH TEST
23
RXTX
M1
1 2
34
M2
123
RXTX
M1
1 2
34
M2
1
4
13
4
14
COLLEGAMENTO FOTOCELLULE / PHOTOCELLS CONNECTION
COLLEGAMENTO FOTOCELLULE CON TEST / PHOTOCELLS CONNECTION WITH TEST
1 3 42
TX
1 3 4 52
RX
1 3 42
TX
1 3 4 52
RX
1 3 42
TX
1 3 4 52
RX
1 3 42
TX
1 3 4 52
RX
( AU01900 - AU01910 )
CONSULTARE IL MANUALE DELLE FOTOCELLULE PER MAGGIORI DETTAGLI / REFER TO THE PHOTOCELLS MANUAL FOR DETAILED CONNECTION DIAGRAMS
COLLEGAMENTO FOTOCELLULE / PHOTOCELLS CONNECTION
4
11
23
RXTX
M1
1 2
34
M2
123
RXTX
M1
1 2
34
M2
1
( AU02000 )
( AU01900 - AU01910 )
( AU02000 )
START (NO)
SAF.(8K2)
COM
PHOTO (NC)
PED (NO)
COM
STOP/SAF.(8K2)
M2
8 9 10 11
12
1314
COM
+24Vcc TEST.
MOTOR
MOTOR
+24Vdc
M3
15 16 17 18 19
START (NO)
SAF.(8K2)
COM
PHOTO (NC)
PED (NO)
COM
STOP/SAF.(8K2)
M2
8 9 10 11
12
1314
COM
+24Vcc TEST.
MOTOR
MOTOR
+24Vdc
M3
15 16 17 18 19
START (NO)
SAF.(8K2)
COM
PHOTO (NC)
PED (NO)
COM
STOP/SAF.(8K2)
M2
8 9 10 11
12
1314
COM
+24Vcc TEST.
MOTOR
MOTOR
+24Vdc
M3
15 16 17 18 19
START (NO)
SAF.(8K2)
COM
PHOTO (NC)
PED (NO)
COM
STOP/SAF.(8K2)
M2
8 9 10 11
12
1314
COM
+24Vcc TEST.
MOTOR
MOTOR
+24Vdc
M3
15 16 17 18 19

SC24
I-UK
START (NO)
SAF.(8K2)
COM
PHOTO (NC)
PED (NO)
COM
STOP/SAF.(8K2)
M2
8 9 10 11
12
1314
START (NO)
SAF.(8K2)
COM
PHOTO (NC)
PED (NO)
COM
STOP/SAF.(8K2)
M2
8 9 10 11
12
1314
START (NO)
SAF.(8K2)
COM
PHOTO (NC)
PED (NO)
COM
STOP/SAF.(8K2)
M2
8 9 10 11
12
1314
START (NO)
SAF.(8K2)
COM
PHOTO (NC)
PED (NO)
COM
STOP/SAF.(8K2)
M2
8 9 10 11
12
1314
4
15
COLLEGAMENTO “DISPOSITIVO DI SICUREZZA” NC / NC “SAFETY DEVICE” CONNECTION
8K2
416
COLLEGAMENTO “DISPOSITIVO DI SICUREZZA” 8K2 / “SAFETY DEVICE” CONNECTION 8K2
8K2
NC
NC
NC
8K2
4
17
COLLEGAMENTO “DISPOSITIVO DI SICUREZZA” NC AGGIUNTIVO / ADDITIONAL NC “SAFETY DEVICE” CONNECTION
8K2
4
18
COLLEGAMENTO “DISPOSITIVO DI SICUREZZA” 8K2 AGGIUNTIVO / ADDITIONAL “SAFETY DEVICE” CONNECTION 8K2
8K2
NC
NC
NC
8K2
ON
10
OFF DIP SWITCH 10 = ON
ON
10
OFF DIP SWITCH 10 = ON
7

SC24
I-UK
31
IMPOSTAZIONE DI DEFAULT DIP SWITCH SW4 / DIP SWITCH SW4 DEFAULT SETTINGS
20
1 2
ON
OFF
TENTATIVI MULTIPLI DOPO INTERVENTO SICUREZZE ABILITATO
ADDITIONAL ATTEMPTS AFTER SECURITY DEVICES INTERVENTION ENABLED
INUTILIZZATO / UNUSEDINUTILIZZATO / UNUSED
TENTATIVI MULTIPLI DOPO INTERVENTO SICUREZZE DISABILITATO
ADDITIONAL ATTEMPTS AFTER SECURITY DEVICES INTERVENTION DISABLED
LEGGERE IL MANUALE PRIMA DI MODIFICARE LE IMPOSTAZIONI DI DEFAULT
READ THE MANUAL BEFORE MODIFYING DEFAULT SETTINGS
31
TRIMMER “PAUSE”
21
PAUSE 2 SECONDS
PAUSA 2 SECONDI
PAUSE 250 SECONDS
TEMPO PAUSA 250 SECONDI
ON
1 2 345 6 78 9 10
OFF
PRELAMPEGGIO DISABILITATO / PRE-FLASHING DISABLED
ENERGY SAVING - TEST SICUREZZE DISABILITATO
ENERGY SAVING - SAFETY DEVICES TEST DISABLED
PRELAMPEGGIO ABILITATO / PRE-FLASHING ENABLED
ENERGY SAVING - TEST SICUREZZE ABILITATO
ENERGY SAVING - SAFETY DEVICES TEST ENABLED
FOTOCELLULA IN APERTURA DISABILITATA / PHOTOCELL DURING OPENING DISABLED
FOTOCELLULA IN APERTURA ABILITATA / PHOTOCELL DURING OPENING ENABLED
CHIUSURA AUTOMATICA ABILITATA / AUTOMATIC CLOSING ENABLEDCHIUSURA AUTOMATICA DISABILITATA / AUTOMATIC CLOSING DISABLED
RALLENTAMENTI DISABILITATI / DECELERATION DISABLEDRALLENTAMENTI ABILITATI / DECELERATION ENABLED
RICHIUSURA RAPIDA DISABILITATA / FAST CLOSING DISABLEDRICHIUSURA RAPIDA ABILITATA / FAST CLOSING ENABLED
NON UTILIZZATO / UNUSEDNON UTILIZZATO / UNUSED
MORSETTO 9 COME STOP 8k2 / TERMINAL 9 AS 8k2 STOPMORSETTO 9 COME COSTA 8k2 / TERMINAL 9 AS 8k2 SAFETY EDGE
OFF-OFF = PASSO-PASSO CON STOP / STEP BY STEP WITH STOP
ON-OFF = PASSO-PASSO / STEP BY STEP
OFF-ON = CONDOMINIALE / AUTOMATIC
ON-ON = UOMO PRESENTE / DEAD MAN
LOGICA DI FUNZIONAMENTO / WORKING LOGIC
IMPOSTAZIONE DI DEFAULT DIP SWITCH SW1 / DIP SWITCH SW1 DEFAULT SETTINGS
4
19
8

SC24
I-UK
9
31
TRIMMER “AMP. SLOW”
22
HIGH SENSITIVITY
ALTA SENSIBILITA’
SENSIBILITA’ INTERVENTO ANTISCHIACCIAMENTO DURANTE IL RALLENTAMENTO
ANTI CRUSHING SENSITIVITY DURING DECELERATION
MEDIUM SENSITIVITY
MEDIA SENSIBILITA’
LOW SENSITIVITY
BASSA SENSIBILITA’
{
RALLENTAMENTO
DECELERATION
{
RALLENTAMENTO
DECELERATION
31
TRIMMER “SLOW”
23
{
RALLENTAMENTO
DECELERATION
{
RALLENTAMENTO
DECELERATION
MOVEMENT SPEED : 9 - THRUST FORCE: 0% 90%
VELOCITA’ ANTA : 90% - FORZA DI SPINTA : 90%
MOVEMENT SPEED : 2 - THRUST FORCE: 0% 20%
VELOCITA’ ANTA : 20% - FORZA DI SPINTA : 20%
VELOCITA’ MOTORE DURANTE IL RALLENTAMENTO
MOTOR SPEED DURING DECELERATION
400mm MIN. 400mm MIN.
400mm MIN. 400mm MIN.

SC24
I-UK
10
31
TRIMMER “AMP. FORCE”
24
HIGH SENSITIVITY
ALTA SENSIBILITA’
MEDIUM SENSITIVITY
MEDIA SENSIBILITA’
LOW SENSITIVITY
BASSA SENSIBILITA’
31
TRIMMER “FORCE”
25
MOVEMENT SPEED : 100 - THRUST FORCE: % 100%
VELOCITA’ ANTA : 100% - FORZA DI SPINTA : 100%
MOVEMENT SPEED : 2 - THRUST FORCE: 0% 20%
VELOCITA’ ANTA : 20% - FORZA DI SPINTA : 20%
{
SENSIBILITA’ INTERVENTO ANTISCHIACCIAMENTO DURANTE IL MOTO NORMALE
ANTICRUSHING SENSITIVITY DURING NORMAL MOVEMENT
VELOCITA’ MOTORE DURANTE IL MOTO NORMALE
MOTOR SPEED DURING NORMAL MOVEMENT
{

SC24
I-UK
11
12/24V
0Vac
LAMP
GND
+SK
CN1
LS1
F1
CB24V
D9_12D7
K1
F2
D6
BATT+BATT
012G0
SW1
31
COLLEGAMENTO CON CARICABATTERIE CB24 / CONNECTIONS WITH CB24 BATTERY CHARGER CONTROL BOARD
26
M1
COM
24Vac
0Vac
+SK
-
SK
LAMP
1 2 3 4 567
SPIA
1 2 3 4 5

GI.BI.DI. S.r.l.
46025 Poggio Rusco (MN) - ITALY
Tel. +39.0386.52.20.11
Fax +39.0386.52.20.31
E-mail: [email protected]
Numero Verde: 800.290156
Via Abetone Brennero, 177/B
w w w . g i b i d i . c o m
Cod. AIC8744 - Rev. 00
This manual suits for next models
1
Other GBD Control Unit manuals