GE RAB24 User manual

31-5000413 Rev. 1 07-19 GEA
Installation Instructions
for your new
RAB24
Standard Steel Wall Sleeve
for 24” Thru-The-Wall Air
Conditioners
Before you begin - Read these instructions completely
and carefully. IMPORTANT – OBSERVE ALL
GOVERNING CODES AND ORDINANCES. Note to
Installer – Be sure to leave these instructions with the
Consumer. Note to Consumer – Keep these instructions
with your Owner’s Manual for future reference.
NOTE:
Handle the wall sleeve carefully.
CRITICAL DIMENSIONS
Ceiling
“A”
“B”
“C”
Roomside
Outside wall
“D”
)LQLVKHGÀRRURUWRSRIFDUSHW
NOTE: Care should be taken in location of electrical
supply entry in relationship to wall sleeve to ensure
access to power once the unit is installed.
Dimensions Recommended Installation Clearance
A7RSRIZDOOVOHHYHWR¿QLVKHGFHLOLQJ´
min.
B3URMHFWLRQRIZDOOVOHHYHLQWRURRP´
PLQWR´PD[UHFRPPHQGHG7KLV
DOORZVWKHWULPSLHFHWR¿WSURSHUO\
C3URMHFWLRQRIZDOOVOHHYHWRRXWVLGH´
min.
D+HLJKWDERYH¿QLVKHGÀRRURUWRSRI
FDUSHW´PLQ
E/HIW5LJKWVLGHRIZDOOVOHHYHWRDGMDFHQW
ZDOO´PLQ
INSTALL WALL SLEEVE LEVEL FROM SIDE TO SIDE
AND WITH A SLIGHT TILT FROM FRONT TO REAR
WALL SLEEVE LOCATION
$VDJHQHUDOUXOHWKHDLUFRQGLWLRQHUVKRXOG
be located in an outside wall to ensure proper
distribution of conditioned air. It should be located
in a portion of the wall where there is no electrical
ZLULQJRUSOXPELQJDQGZKHUHWKHUHDUHQR
obstructions immediately inside or outside.
Outside wall
“E”
“E”
Top of case
Top of wall sleeve

2
STEP 1: Preparation of the wall
7KHZDOOVOHHYHVKRXOGEHLQVWDOOHGGXULQJFRQVWUXFWLRQ
and lintels should be used to support the block above
the wall sleeve. The wall sleeve will not support the con-
FUHWHEORFNRUEULFN7KHZDOOVOHHYHLVPRGXODULQKHLJKW
and width:
+HLJKW ±)LWVFRXUVHVFRQFUHWHEORFN
±)LWVFRXUVHVVWDQGDUGEULFN
±)LWVFRXUVHVMXPEREULFN
:LGWK ±)LWVDSSUR[LPDWHO\VWXGVSDFHV
)RUH[LVWLQJFRQVWUXFWLRQZDOORSHQLQJVPXVWEHPDGH
:DOORSHQLQJVRIWKHSURSHUGLPHQVLRQVDUHHVVHQWLDOWR
DYRLGWKHQHFHVVLW\RI¿OOHUVRUDGGLWLRQDOIUDPLQJ
“D”*
Main stud
Jack studs
6XEÀRRr
Jack studs
Cripple
Adjust framing
tRVHFure this
dimeQVLRn
( *See chart
RQSDJe 1)
Finished
ÀRRr
Header - 4” x 4” Rr
twR´[´RQHGJe
25Ǭ” Min.
15Ǫ” Min.
NOTE: 8VHOLQWHOWRVXSSRUWEULFNEORFNHWFDERYHWKH
air conditioner wall sleeve. (If directly under a window
VLOOWKHXVHRIDOLQWHOPD\QRWEHQHFHVVDU\
0LQLPXP)LQLVKHG2SHQLQJ
Dimensions* Wall Sleeve Dimensions
+HLJKW Width +HLJKW Width Depth
´
´
´ ´ ´
'LPHQVLRQVPD\QHHGWREHLQFUHDVHGWR¿WXQLTXHVLWXDWLRQVLQWKH
¿HOGLIXVLQJFDVHDQJOHV
STEP 2: Assemble Wall Sleeve
6HWWKHERWWRPSDQHORQDFOHDQÀDWOHYHOVXUIDFH
Front View
/RFDWHOHIWVLGHSDQHO$OLJQSDQHOLQWKHOHIWERWWRP
SDQHOVORW)XOO\,QVHUWWKHOHIWSDQHOLQWRWKHERWWRP
panel until all tabs lock completely.
Front View
/RFDWHULJKWVLGHSDQHO$OLJQSDQHOLQWKHULJKWERWWRP
SDQHOVORW)XOO\LQVHUWULJKWSDQHOLQWRERWWRPSDQHO
XQWLOORFNLQJWDEVORFNFRPSOHWHO\
Front View
/RFDWHWRSSDQHODQGDOLJQZLWKWRSRIULJKWDQGOHIW
VLGHSDQHOV)XOO\LQVHUWWRSSDQHOLQWRULJKWDQGOHIW
VLGHSDQHOVXQWLOORFNLQJWDEVORFNFRPSOHWHO\
Front View
,IUHTXLUHG/RFDWHZHDWKHUEDUULHUDQGDWWDFKWRWKH
UHDURIWKHDVVHPEOHGVOHHYHZLWKIRXUVXSSOLHG
white push pins.
4
3
2
1
Weather Barrier
Rear View
Installation Instructions
WEATHER
BARRIER PUSH PINS (4)MOUNTING
BRACKETS (4)
PLASTIC HOLE
PLUGS (4)
No. 10A X Ǫ”
SLOTTED HEX
SCREWS (4)

3
Installation Instructions
STEP 3: Installation of the wall sleeve in
the wall opening
OPTION 1
1. Position the wall sleeve into the wall. Refer to chart on
SDJHIRUURRPVLGHSURMHFWLRQ7KHUHDURXWVLGHHGJH
RIWKHZDOOVOHHYHVKRXOGH[WHQGDWOHDVWó´EH\RQGWKH
RXWVLGHZDOOWREHDEOHWRFDXONSURSHUO\DQGSUHYHQWVHDOLQJ
WKHGUDLQKROHVLQWKHUHDUÀDQJHRIWKHZDOOVOHHYHDQGWR
IDFLOLWDWHHDV\LQVWDOODWLRQRIDQDFFHVVRU\GUDLQLIGHVLUHG
LILWLVGHVLUHGWRKDYHWKHUHDUJULOOHÀXVKRQWKHRXWVLGHD
GULSUDLOPXVWEHLQVWDOOHGXQGHUWKHZDOOVOHHYHDQGFDXONLQJ
DSSOLHGEHWZHHQWKHGULSUDLODQGZDOOVOHHYH
IMPORTANT:
Install wall sleeve level from side to side and with a slight
tilt from front to rear. Use a level; no more than a ¼ bub-
ble will be the correct wall sleeve slant to the outside.
Inside wall
)LUPO\VHFXUHWKHZDOOVOHHYHWRWKHZDOOVWUXFWXUHXVLQJWKH
H[LVWLQJKROHVRQWKHVLGHVDQGWRSRUE\GULOOLQJQHZKROHV
in the appropriate location. Do NOT drill any holes in the
bottom of the wall sleeve.8VHDSSURSULDWHVFUHZVODJ
EROWVHWFWRDWWDFKWKHZDOOVOHHYHWRWKHZDOOVWUXFWXUH
Secure case through
side and/or top only
2” min. from
case bottom
8VHDOLQWHOZKHQUHTXLUHGWRVXSSRUWEULFNDQGEORFNDERYH
the wall sleeve.
NOTE: Do not drill any holes in the wall sleeve for electrical
connections.
STEP 3: Installation of the wall sleeve in
the wall opening (cont.)
OPTION 2
Installation of the wall sleeve into wall using
mounting brackets
8VH0RXQWLQJ%UDFNHWVSURYLGHGIRUSURSHUSRVLWLRQLQJRI
VOHHYHLQIUDPHGZDOORSHQLQJ6HH([SORGHG3DUWV3LFWXUH
3DJH6HOHFWHLWKHUIURQWRUUHDUVHWRIVOHHYHPRXQWLQJ
KROHVZKLFKZKHQDOLJQHGZLWKRQHRIWKHPRXQWLQJEUDFNHW
KROHVSURYLGHVWKHGHVLUHGSURMHFWLRQRIWKHVOHHYHLQWR
URRP5HPRYHSODVWLFKROHSOXJVIURPSODVWLFEDJRI
WKHLQFOXGHGSDUWV)DVWHQEUDFNHWVWRVOHHYHZLWKVFUHZV
IXUQLVKHGXVLQJVDPHKROHORFDWLRQLQHDFKPRXQWLQJ
EUDFNHW6LGHPRXQWLQJKROHVLQVOHHYHDUHRႇVHWIURPWRS
PRXQWLQJKROHVWRJLYHVOHHYHSURSHUUHDUZDUGVORSHWR
RXWVLGH,QVWDOOSODVWLFKROHSOXJVLQHPSW\KROHV
Alternate applications using wall sleeve mounting brackets
)UDPH&RQVWUXFWLRQDQG%ULFN9HQHHU
)UDPH2SHQLQJ0LQLPXP'LPHQVLRQV
Solid Masonary Construction - Block
)UDPH2SHQLQJ0LQLPXP'LPHQVLRQV
Solid Masonary Construction - Brick and Block
)UDPH2SHQLQJ0LQLPXP'LPHQVLRQV
ALTERNATE OPENING
2 x 4
FRAMING
25
15 ǫ”
LINTEL PURCHASED LOCALLY
SLEEVE
ELECTRICAL WALL
RECEPTACLE
25
15 ǫ”
36” MAX.
ALTERNATE OPENING
2 x 4
FRAMING
25
15 ǫ”
LINTEL PURCHASED LOCALLY
SLEEVE
ELECTRICAL WALL
RECEPTACLE
25
15 ǫ”
36” MAX.
LINTEL PURCHASED LOCALLY
SLEEVE
ELECTRICAL WALL
RECEPTACLE
36” MAX.
ALTERNATE OPENING
2 x 4
FRAMING
25
15 ǫ”
25
15 ǫ”
Inside wall
Secure wall sleeve
WKURXJKVLGHDQGRU
top only
´PLQIURPZDOO
sleeve bottom

4
Installation Instructions
67(3:HDWKHUSURR¿QJ
:HDWKHUSURRIJDSVEHWZHHQWKHH[WHULRUDQGLQWHULRUZDOOVDQG
WKHZDOOVOHHYHZLWKFDXONLQJRUHTXLYDOHQWZHDWKHUSURR¿QJ
material.
Caulk* Steel lintel
Caulk*
Outdoor
grille
Room
cabinet
Caulk*
Case
Caulk*
*NOTE: It is critical to caulk around the perimeter of the wall
sleeve on all four sides and on the outside and the roomside
ZKHUHLWMRLQVWKHEXLOGLQJWRSUHYHQWDLUDQGZDWHULQ¿OWUDWLRQ
For installation in extra thick walls
1. The wall sleeve should not be installed in a thick wall where
WKHZDOOVOHHYHLVUHFHVVHGPRUHWKDQ´
,IWKHZDOOVOHHYHLVEHLQJLQVWDOOHGLQDZDOOZKHUHWKHUHFHVV
LV´RUOHVVÀDVKLQJPXVWEHLQVWDOOHGXQGHUWKHZDOOVOHHYH
DQGH[WHQGXS´RQHDFKVLGH7KHÀDVKLQJPXVWLQFOXGHD
GULSUDLODVLOOXVWUDWHGLQWKH¿JXUHEHORZ
Outdoor
grille
Drip rail
Case
Caulk* Flashing
*NOTE: It is critical to caulk around perimeter of wall sleeve
RQDOOIRXUVLGHVZKHUHLWMRLQVWKHEXLOGLQJWRSUHYHQWDLUDQG
ZDWHULQ¿OWUDWLRQ
Electrical Requirements (230V/208V)
Provisions should be made to have the proper electrical outlet
QHDUWKHZDOOVOHHYH$OOZLULQJVKRXOGEHPDGHLQDFFRUGDQFH
ZLWKORFDOFRGHVDQGUHJXODWLRQV7KHOLQHFRUGZLOOH[WHQGWR
a wall receptacle located within the area shown in the table
below.
$OOZLULQJVKRXOGEHPDGHLQDFFRUGDQFHZLWKORFDOHOHFWULFDO
FRGHVDQGUHJXODWLRQV
6HHWKH2ZQHU¶V0DQXDOIRUKRZWRFRQQHFWHOHFWULFDOVXSSO\
NOTE: $OXPLQXPZLULQJLQVWUXFWXUHPD\SRVHVSHFLDO
SUREOHPVFRQVXOWDTXDOL¿HGHOHFWULFLDQ
Drain Kit (optional)
,ILWLVQHFHVVDU\WRLQVWDOODGUDLQNLWRQWKLVZDOOVOHHYH
WKHIROORZLQJNLWLVDYDLODEOH
RAD10 External Drain
7KLVH[WHUQDOGUDLQZLOOFDUU\FRQGHQVDWHZDWHUDZD\
IURPWKHXQLWDQGWKHEXLOGLQJ
7RLQVWDOOIROORZWKHLQVWUXFWLRQPDQXDOLQFOXGHGZLWK
the kit.
6SHFL¿FDWLRQVVXEMHFWWRFKDQJHZLWKRXWQRWLFH
A Quality Product of GE Appliances
Wall Receptacles
A
Inside
120V/115V 15 amp 230V/208V 20 amp
“tandem” type “perpendicular” type
MODEL “A” “B”
115V 50” 74”
230/208V
65”
B
39”
Wall
Sleeve
Wall
Sleeve

31-5000413 Rev. 1 07-19 GEA
Instructions d’installation pour votre
nouveau
RAB24
Gaine d’acier standard pour climatiseurs 24
po à travers mur
Avant de commencer - Veuillez lire ces instructions
attentivement et en totalité. IMPORTANT – OBSERVEZ
TOUS LES CODES ET RÈGLEMENTS EN VIGUEUR.
Note à l’installateur – Assurez-vous de laisser ces
instructions au consommateur. Note au consommateur
- Conservez ces instructions avec votre manuel
d’utilisation pour consultation ultérieure.
REMARQUES: Manipulez la gaine avec soin.
DIMENSIONS CRITIQUES
Ceiling
“A”
“B”
“C”
Roomside
Outside wall
“D”
)LQLVKHGÀRRURUWRSRIFDUSHW
REMARQUE :
Une attention particulière doit être portée à
l’emplacement de l’entrée électrique par rapport à la
JDLQHPXUDOHD¿QG¶DVVXUHUO¶DFFqVjO¶DOLPHQWDWLRQ
une fois l’appareil installé.
Dimensions Dégagements d’installation recommandés
A'HVVXVGHJDLQHMXVTX¶DXSODIRQG¿QLSR
min.
B Saillie de la gaine dans la pièce - 1/8 min. à 3/4
po max. recommandé. Cela permet de poser la
garniture correctement.
C Saillie de la gaine vers l’extérieur - 1/4 po min.
D+DXWHXUDXGHVVXVGXSODQFKHU¿QLRXGXGHV-
sus de tapis - 2 po min.
E Côté gauche/droit de la gaine jusqu’au mur
adjacent - 2 po min.
INSTALLEZ LA GAINE EN VÉRIFIANT LE NIVEAU
D’UN CÔTÉ À L’AUTRE ET AVEC UNE LÉGÈRE
INCLINAISON D’AVANT EN ARRIÈRE.
EMPLACEMENT DE LA GAINE
En règle générale, le climatiseur doit être placé
dans un mur extérieur pour assurer une distribution
d’air climatisé convenable. Cette section de mur
doit être dépourvue de câblage électrique, de
plomberie et d’obstructions immédiatement à
l’intérieur ou l’extérieur.
Outside wall
“E”
“E”
Top of case
Intérieur de la pièce
Dessus du boîtier Mur extérieur
3ODQFKHU¿QLRXGHVVXVGHODPRTXHWWH
Plafond
Mur extérieur
Table of contents
Other GE Air Conditioner Accessories manuals
Popular Air Conditioner Accessories manuals by other brands

Mitsubishi Electric
Mitsubishi Electric PAC-SNH11HS-E installation manual

Unitary products group
Unitary products group 2CE Series installation instructions

Qlima
Qlima EU-ODZ104 user manual

Tecnosystemi
Tecnosystemi smart clima SCD500163 user manual

Waeco
Waeco AirCon Service Center ASC 5300 G operating manual

American Standard
American Standard BAYSQRD001AA Installer's guide

Bimar
Bimar AP11 Instruction booklet

Mitsubishi
Mitsubishi PAC-SJ41TM-E installation manual

Tecnosystemi
Tecnosystemi Smart Clima SCD500084 user manual

Samsung
Samsung MIM-H04U User & installation manual

Waeco
Waeco AirConServiceCenter ASC 3500 G LE operating manual

Fujitsu
Fujitsu UTZ-KXGC installation manual