manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. GE
  6. •
  7. Air Conditioner
  8. •
  9. GE AJCQ08ACC User manual

GE AJCQ08ACC User manual

Other GE Air Conditioner manuals

GE ASM08LL User manual

GE

GE ASM08LL User manual

GE ASQ05LK Manual

GE

GE ASQ05LK Manual

GE AEM06 Series Original instructions

GE

GE AEM06 Series Original instructions

GE AWCS12WWF Original instructions

GE

GE AWCS12WWF Original instructions

GE AEM05LM Operating instructions

GE

GE AEM05LM Operating instructions

GE AJCH08ACB User manual

GE

GE AJCH08ACB User manual

GE AGQ05LH User manual

GE

GE AGQ05LH User manual

GE AFH12 Installation instructions

GE

GE AFH12 Installation instructions

GE Appliances AEE23 User manual

GE

GE Appliances AEE23 User manual

GE Zoneline 2900 User manual

GE

GE Zoneline 2900 User manual

GE AHEC05 User manual

GE

GE AHEC05 User manual

GE AGE12DJ User instructions

GE

GE AGE12DJ User instructions

GE AJCM08ACF Series Operating instructions

GE

GE AJCM08ACF Series Operating instructions

GE AJCM08ACG Operating instructions

GE

GE AJCM08ACG Operating instructions

GE AGM18 Operating instructions

GE

GE AGM18 Operating instructions

GE AEW10AN Operating instructions

GE

GE AEW10AN Operating instructions

GE AGM12 Operating instructions

GE

GE AGM12 Operating instructions

GE Zoneline AZ9VH Operating instructions

GE

GE Zoneline AZ9VH Operating instructions

GE AJCS 08 AZ User manual

GE

GE AJCS 08 AZ User manual

GE ASM18DK Manual

GE

GE ASM18DK Manual

GE Appliances AG_18 Operating instructions

GE

GE Appliances AG_18 Operating instructions

GE AVX07 Operating instructions

GE

GE AVX07 Operating instructions

GE Zoneline Installation and user guide

GE

GE Zoneline Installation and user guide

GE AEL08LV Operating instructions

GE

GE AEL08LV Operating instructions

Popular Air Conditioner manuals by other brands

Fujitsu ASYG 09 LLCA installation manual

Fujitsu

Fujitsu ASYG 09 LLCA installation manual

York HVHC 07-12DS Installation & owner's manual

York

York HVHC 07-12DS Installation & owner's manual

Carrier Fan Coil 42B Installation, operation and maintenance manual

Carrier

Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity IDUFCI60KC-3 installation manual

intensity

intensity IDUFCI60KC-3 installation manual

Frigidaire FAC064K7A2 Factory parts catalog

Frigidaire

Frigidaire FAC064K7A2 Factory parts catalog

Sanyo KS2432 instruction manual

Sanyo

Sanyo KS2432 instruction manual

LG MultiV Series installation manual

LG

LG MultiV Series installation manual

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

CLIMAVENETA

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

Midea EWK06CW5 user manual

Midea

Midea EWK06CW5 user manual

Pioneer FAB Series installation manual

Pioneer

Pioneer FAB Series installation manual

SPT WA-1511S user manual

SPT

SPT WA-1511S user manual

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Mitsubishi Electric

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic CS-S18HKQ Service manual

Panasonic

Panasonic CS-S18HKQ Service manual

Panasonic CS-E15NKE3 operating instructions

Panasonic

Panasonic CS-E15NKE3 operating instructions

Gree GWH18TC-K3DNA1B/I Service manual

Gree

Gree GWH18TC-K3DNA1B/I Service manual

Friedrich ZoneAire Compact P08SA owner's manual

Friedrich

Friedrich ZoneAire Compact P08SA owner's manual

Daikin R32 Split Series installation manual

Daikin

Daikin R32 Split Series installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

For answers to your Monogram,® GE Profile™or
GE®appliance questions, visit our website at
ge.com or call GE Answer Center®service,
800.626.2000.
Specification Created 1/07 390236
Listed by
Underwriters
Laboratories
Total volume and shelf
area are calculated by
the Association of Home
Appliance Manufacturers’
standards.
R
AJCQ08ACC
GE®ENERGY STAR®115 Volt Built-in Room Air Conditioner
Note: When installing slide-out chassis units in through-the-wall
applications, keep louvers free. Do not restrict air flow areas.
Parallel
Perpendicular
Wall Oulets
All wiring including installation of receptacle must be made in
accordance with local electrical codes and regulations.
Electrical outlet should be in reach of line cord.
Note:
Aluminum wiring may pose special problems – consult a
qualified electrician.
115V
15 Amp
230/208V
20 Amp
Tandem
Large Tandem
230/208V
15 Amp
230/208V
30 Amp
Premium, Deluxe and Value Model
Wall Case Dimensions (in inches)
Note: When installing units in through-the-wall applications.
Do not restrict air flow areas.
26
15-5/8
16-7/8
AJT08DG QSART
Parallel
115V
15 Amp
Wall Case Dimensions and Installation Information (in inches)
For answers to your Monogram,® GE Profile™or
GE®appliance questions, visit our website at
ge.com or call GE Answer Center®service,
800.626.2000.
Specification Created 1/07
Listed by
Underwriters
Laboratories
Total volume and shelf
area are calculated by
the Association of Home
Appliance Manufacturers’
standards.
R
Dimensions (in inches)
Installation Information: A finished opening of 26-1/8" x
15-3/4" clear of intrusions is required. Keep clearance of
4" from side walls. Brick veneer or frame walls should have
wood studding surrounding case to provide firm anchoring
with screws. Case can be fastened directly to brick or block
walls with screws sunk in lead expansion shields.
Note: Units should be caulked on all four sides of case
to the building exterior to assure building integrity.
Two Wall Cases for Tenant Option Installation
When the air conditioner is offered as a tenant option, these
wall cases provide protection against outside elements.
RAB47 – includes wall case, exterior grille
and steel closure panels.
RAB48 – includes wall case, exterior grille,
steel closure panel and two layers of insulation.
Standard Wall Case RAB46
Solid-sided wall case fabricated of galvanized steel with
baked enamel finish. Welded areas are coated with
a sealing compound to help resist rust and corrosion.
Polymer gasket surrounds opening to assure tight weather
seal. Aluminum grille (RAG13) is included. Panels on interior
and between case and grille provide weather protection prior
to installation of chassis. Provide firm anchoring with screws.
Case can be fastened directly to brick or block walls with
screws sunk in lead expansion shields.
Built-in RAC Installation
(Pub. 1-G003 pg. 138) April 30.1993
Make frame if desired or caulk
between case and siding
15-3/4
26-1/8
Frame Construction
Brick Block and Brick
Frame Construction
Fill open cells
with mortar
or insulation
15-3/4
26-1/8
Lintel
Lintel
OUTSIDE INSIDE
16-7/8
Caulking
Drip Rail
Trim Molding
(if desired)
Plaster Line
Built-In Room Air Conditioners
Wall Opening for RAB36/37/38 Case
A finished opening of 26-1/8" x 15-3/4", clear of
intrusions, is required. Keep clearance of 4" from
side walls. Brick veneer or frame walls should have
wood studding surrounding case to provide firm
anchoring with screws. Case can be fastened directly
to brick or block walls with screws sunk in lead
expansion shields.
Flexible Mounting Position
Built-in RAC Installation
(Pub. 1-G003 pg. 138) April 30.1993
Make frame if desired or caulk
between case and siding
15-3/4
26-1/8
Frame Construction
Brick Block and Brick
Frame Construction
Fill open cells
with mortar
or insulation
15-3/4
26-1/8
Lintel
Lintel
OUTSIDE INSIDE
16-7/8
Caulking
Drip Rail
Trim Molding
(if desired)
Plaster Line
Built-In Room Air Conditioners
Wall Opening for RAB36/37/38 Case
A finished opening of 26-1/8" x 15-3/4", clear of
intrusions, is required. Keep clearance of 4" from
side walls. Brick veneer or frame walls should have
wood studding surrounding case to provide firm
anchoring with screws. Case can be fastened directly
to brick or block walls with screws sunk in lead
expansion shields.
Flexible Mounting Position
Built-in RAC Installation
(Pub. 1-G003 pg. 138) April 30.1993
Make frame if desired or caulk
between case and siding
15-3/4
26-1/8
Frame Construction
Brick Block and Brick
Frame Construction
Fill open cells
with mortar
or insulation
15-3/4
26-1/8
Lintel
Lintel
OUTSIDE INSIDE
16-7/8
Caulking
Drip Rail
Trim Molding
(if desired)
Plaster Line
Built-In Room Air Conditioners
Wall Opening for RAB36/37/38 Case
A finished opening of 26-1/8" x 15-3/4", clear of
intrusions, is required. Keep clearance of 4" from
side walls. Brick veneer or frame walls should have
wood studding surrounding case to provide firm
anchoring with screws. Case can be fastened directly
to brick or block walls with screws sunk in lead
expansion shields.
Flexible Mounting Position
390236
AJCQ08ACC
GE®ENERGY STAR®115 Volt Built-in Room Air Conditioner
Features and Benefits
• 8,000 BTU
• 9.5 EER
• 115 Volts
• ENERGY STAR®qualified
• Electronic digital thermostat with remote
• Four-way air direction
• 3 cool/3 fan speeds
• Up-front, washable air filter
• Power interruption restart
• Model AJCQ08ACC – Soft Gray
Specification Created 1/07
AJCS06L
390236
AJCQ08ACC
GE®ENERGY STAR®115 Volt Built-in Room Air Conditioner