GE BF50EM User manual

a
BF50EM, BF100EM, BF120EM,
BF125EM, BF145EM
e
Easy Mount Bath Fan User’s Guide
210572119 Rev. D 1-08
Item Stock Number(s): BF50EM, BF100EM, BF120EM, BF125EM, BF145EM
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions should always be followed to reduce
the risk of fire, electric shock and injury to person, including the following:
1. Read all instructions before installing or using exhaust fan.
2. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer.
3. Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When the
service disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service
panel.
SAVE THESE INSTRUCTIONS
IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
4. Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and
standards, including fire-related construction.
5. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment to
prevent back drafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA)
and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
1 of 4
www.geelectrical.com

210572119 Rev. D 1-08
GENERAL SAFETY INFORMATION
(Continued)
CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT
USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND
VAPORS.
6. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. This unit must be grounded.
9. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
10. Acceptable for use over a bathtub or shower when installed in a
GFCI protected branch circuit.
11. NEVER place a switch where it can be reached from a tub or shower.
WARNING: DO NOT USE IN KITCHENS
INSTALLATION INSTRUCTIONS
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE
PANEL BEFORE STARTING INSTALLATION.
SECTION 1
Preparing the Exhaust Fan
1. Unpack fan from the carton and confirm that all pieces are present.
In addition to the exhaust fan you should have:
1 - Grill
1 - Damper Assembly (attached)
1 - Mounting Bracket
1 - Hardware Bag
1 - Electrical Connector
3 - Wire Nuts
1 - Instruction/Safety Sheet
2. Remove the wire compartment cover and store in the carton until
needed so it does not get damaged or lost (Figure 1).
3. Choose the location for your fan. To
ensure the best air and sound
performance, it is recommended that
the length of ducting and the number
of elbows be kept to a minimum, and
that insulated hard ducting be used.
Larger duct sizes will reduce noise and
airflow restrictions.
4. Select the most convenient electrical
knockout and remove using a straight-
blade screw driver (Figure 2).
SECTION 2
New Construction
1. Using the gauge on the mounting bracket, line up the bracket on
the joist so the bottom of the fan will be flush with the finished
ceiling. Nail or screw the bracket in place securely (Figure 3).
2. Snap the fan body into the bracket (Figure 4). The fan can be
snapped into position with the duct collar facing to the left or the
right depending which is most convenient.
SECTION 3
Existing Construction
1. Position housing against the joist or stud and trace an outline of
the housing onto the ceiling/wall material. Set housing aside and
cut opening, being careful not to cut or damage any electrical or
other hidden utilities (Figure 5).
2. Line up the bracket on the joist so the bottom of the fan will be
flush with the finished ceiling. Nail or screw the snap-in bracket
in place securely (Figure 3).
3. Snap the fan body into the bracket (Figure 4). The fan can be
snapped into position with the duct collar facing to the left or the
right depending which is most convenient.
SECTION 4
Ducting
Figure 1
Figure 2
1/2"
3/4"
Figure 3
Figure 4
Figure 5
2 of 4
www.geelectrical.com

210572119 Rev. D 1-08
CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND
NATIONAL BUILDING CODES.
1. Connect the ducting to the fan’s duct collar (Figure 5). Secure in
place using tape or screw clamp. Always duct the fan to the
outside through a wall or roof cap.
SECTION 5
Wiring
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE
PANEL BEFORE STARTING INSTALLATION.
CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE MADE
IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL
ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF
INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A
QUALIFIED ELECTRICIAN.
1. Run wiring from an approved wall switch carrying the appropriate
rating. One neutral (white), one ground (green or bare copper), and
one hot (black lead connected to the switch). Secure the electrical
wires to the housing with an approved electrical connector. Make
sure you leave enough wiring in the box to make the connection to
the fan’s receptacle.
2. From where you have access to inside the fan’s junction box,
connect the White wire from the house to the White wire from
the fan’s receptacle. Connect the Black wire from the wall switch
to the Black wire from the fan’s receptacle. Connect the ground
wire from the house to the Green wire from the fan’s receptacle
(Figure 7). Use approved methods for all connections.
SECTION 6
Completing the Installation
1. Reinstall the fan’s wire compartment cover. Rotate the blower wheel
by hand to ensure it spins freely. Plug the fan’s quick connect motor
cord into the receptacle. This cord will only fit one way into the
receptacle (Figure 8).3. Restore power and test your installation.
2. Install the grill by squeezing the two ends of the springs together
and installing them up into the slots of the fan’s housing. Push the
grill up into position (Figure 9).
3. Restore power and test your installation.
SECTION 7
Use and Care
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE
PANEL BEFORE SERVICING THE UNIT.
1. Cleaning the Grill: Remove grill and use a mild detergent, such
as dishwashing liquid, and dry with a soft cloth. NEVER USE ANY
ABRASIVE PADS OR SCOURING POWDERS. Completely dry grill
before reinstalling. Refer to instructions in Section 6
Finishing the
Installation
, to reinstall grill.
2. Cleaning the Fan Assembly: Unplug the motor cord from receptacle.
Wipe all parts with a dry cloth or gently vacuum the fan. NEVER
IMMERSE ELECTRICAL PARTS IN WATER. Plug the motor cord
back in and restore power.
Troubleshooting Guide
Trouble Probable Cause Suggested Remedy
1. Fan does not operate when the switch is on. 1a. A fuse may be blown or a circuit tripped. 1a. Replace fuse or reset circuit breaker.
1b. Connector plug from motor is not plugged in. 1b. Turn off power to unit. Remove Grill and plug motor into
receptacle in housing. Restore power to unit.
1c. Wiring is not connected properly. 1c. Turn off power to unit. Check that all wires are connected.
2. Fan is operating, but air moves slower than normal. 2. Obstruction in the exhaust ducting. 2. Check for any obstructions in the ducting. The most common
are bird nests in the roof cap or wall cap where the fan
exhausts to the outside.
3. Fan is operating louder than normal. 3a. Motor is loose. 3a. Turn off power to unit. Remove grill and check that all screws
are fully tightened. Restore power to unit.
3b. Fan blade is hitting housing of unit. 3b. Call your dealer for service.
Figure 6
Figure 7 Ground
Supply
from
house
White
Hot (Black)
Figure 8
Figure 9
3 of 4
www.geelectrical.com

WARRANTY
WHAT IS COVERED?
Full Five Year Parts Warranty from date of original proof of purchase. We will
provide, free of charge, a replacement part that fails due to manufacturing
defect in material or workmanship, when installed and used as directed in
the User’s Guide.
This warranty is extended to the original purchaser for products purchased
for ordinary home use.
GE Bath Fan Hot Line
1-800-684-9975
FOR TECHNICAL ASSISTANCE
AND / OR QUESTIONS.
Read your User’s Guide. If you have any questions about operating the product, please contact your dealer.
Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages and some states do not allow limitations on how
long an implied warranty lasts, so these exclusions or limitations may not apply to you. This warranty gives you specific legal rights and you may have other
rights which vary from state to state and province to province.
WHAT IS NOT COVERED?
• Installation services or service trips to your home to teach you how to use
the product.
• Labor costs or the cost of replacement components as part of routine
maintenance.
• Failure or defects in product arising from Improper installation
If you have an installation problem, contact your dealer or installer. You are
responsible for providing adequate electrical, exhausting and other connecting
facilities. See the Installation Instructions provided with this product for
electrical, exhaust and connection details.
• Replacement of house fuses or resetting of circuit breakers.
• Failure of the product if it is used for something other than the intended
purpose of manufacturer or used commercially.
• Damage to the product caused by accident, fire, floods, acts of customer,
or acts of God.
This warranty contains the sole and exclusive warranty of GE for claims based on defects in these products. Upon the expiration of the warranty period, all
such liability shall terminate. There are no other warranties, whether written, oral, implied or statutory. NO IMPLIED STATUTORY WARRANTY OF MERCHANTABILITY
OR FITNESS FOR PARTICULAR PURPOSE SHALL APPLY.
IN NO EVENT SHALL GE BE LIABLE FOR ANY SPECIAL, CONSEQUENTIAL, INDIRECT, OR INCIDENTAL DAMAGES, SUCH AS, BUT NOT LIMITED TO, LOSS OF PROFIT
OR REVENUES, LOSS OF USE OF THE PRODUCTS OR ANY ASSOCIATED EQUIPMENT, DAMAGE TO ASSOCIATED EQUIPMENT, OR COST OF SUBSTITUTE PRODUCTS.
IN NO EVENT, SHALL GE’S LIABILITY TO BUYER FROM THE SALE OF THESE PRODUCTS EXCEED THE PRICE OF THE DEFECTIVE PRODUCT SOLD AND ANY SUCH
LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD.
210572119 Rev. D 1-08
1
14
2
3
4
5
6
7
8
9
10
11
12
13
4 of 4
www.geelectrical.com
# Qty. Description Replacement Part#
1 1 Fan Housing 5S2205001
2 1 Collar 5S2205002
3 1 Damper 5S2205003
4 1 Polarized Nylon Receptacle 3P 5S2205004
5 1 Wire Cover 5S2205005
6 1 Screw 5S2205006
7 1 Motor - 50 CFM 5S2205011
1 Motor - 100 CFM 5S2205008
1 Motor - 120 CFM 5S2299002
8 2 Clip 5S2205009
9 2 Screw 5S2205010
10 1 Motor Bracket 5S2299003
11 1 Blower Wheel 5S2299004
12 1 Grill 5S2205011
13 2 Grill Springs 5S2205012
14 1 Snap In Bracket 5S2205013
This manual suits for next models
4
Table of contents
Other GE Fan manuals