manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Genie
  6. •
  7. Garage Door Opener
  8. •
  9. Genie GCL-MH User manual

Genie GCL-MH User manual

Other Genie Garage Door Opener manuals

Genie 1035 Manual

Genie

Genie 1035 Manual

Genie Quietlift 2M User manual

Genie

Genie Quietlift 2M User manual

Genie 2024 User manual

Genie

Genie 2024 User manual

Genie 3020H User manual

Genie

Genie 3020H User manual

Genie 4560 Manual

Genie

Genie 4560 Manual

Genie PowerMax1200 Manual

Genie

Genie PowerMax1200 Manual

Genie 2562 User manual

Genie

Genie 2562 User manual

Genie genie manuals-instructions Installation instructions

Genie

Genie genie manuals-instructions Installation instructions

Genie Aladdin Connect User manual

Genie

Genie Aladdin Connect User manual

Genie IntelliG 1000 User manual

Genie

Genie IntelliG 1000 User manual

Genie Series H User manual

Genie

Genie Series H User manual

Genie POSTER User manual

Genie

Genie POSTER User manual

Genie Excelerator User manual

Genie

Genie Excelerator User manual

Genie Garage Door Opener User manual

Genie

Genie Garage Door Opener User manual

Genie GCL-MT User manual

Genie

Genie GCL-MT User manual

Genie QuietLift 2040C User manual

Genie

Genie QuietLift 2040C User manual

Genie GCL-H User manual

Genie

Genie GCL-H User manual

Genie GPS-IC Series User manual

Genie

Genie GPS-IC Series User manual

Genie 36664R Series Use and care manual

Genie

Genie 36664R Series Use and care manual

Genie DirectLift 2060 User manual

Genie

Genie DirectLift 2060 User manual

Genie GCL-J&H 1/2HP User manual

Genie

Genie GCL-J&H 1/2HP User manual

Genie ReliaG 600 Instruction Manual

Genie

Genie ReliaG 600 Instruction Manual

Genie GCL-GH User manual

Genie

Genie GCL-GH User manual

Genie 39276R.S Use and care manual

Genie

Genie 39276R.S Use and care manual

Popular Garage Door Opener manuals by other brands

ATA GDO-6 EasyRoller instruction manual

ATA

ATA GDO-6 EasyRoller instruction manual

CAME F4000 Series installation manual

CAME

CAME F4000 Series installation manual

Garaga SECURITY+ 3265GCM 1HP owner's manual

Garaga

Garaga SECURITY+ 3265GCM 1HP owner's manual

Chamberlain Whisper Drive SECURITY+ WD822K Series owner's manual

Chamberlain

Chamberlain Whisper Drive SECURITY+ WD822K Series owner's manual

Chase Doors DuraShield installation manual

Chase Doors

Chase Doors DuraShield installation manual

CSI Classic installation instructions

CSI

CSI Classic installation instructions

Chamberlain Elite 3575S owner's manual

Chamberlain

Chamberlain Elite 3575S owner's manual

Richmond GTR156 user manual

Richmond

Richmond GTR156 user manual

B&D Controll-A-Door 5 instruction manual

B&D

B&D Controll-A-Door 5 instruction manual

Chamberlain MyQ 940ESTD owner's manual

Chamberlain

Chamberlain MyQ 940ESTD owner's manual

Automatic Technology GDO-9V1 SecuraLift installation instructions

Automatic Technology

Automatic Technology GDO-9V1 SecuraLift installation instructions

Westfalia 19 36 07 instruction manual

Westfalia

Westfalia 19 36 07 instruction manual

Chamberlain HD520EVP manual

Chamberlain

Chamberlain HD520EVP manual

Cardin BL Series instruction manual

Cardin

Cardin BL Series instruction manual

Chamberlain 8355 - 1/2 hp installation instructions

Chamberlain

Chamberlain 8355 - 1/2 hp installation instructions

Bauer CROSS18 Application. Installation and Maintenance Manual

Bauer

Bauer CROSS18 Application. Installation and Maintenance Manual

Dorma ES 90 manual

Dorma

Dorma ES 90 manual

Wayne-Dalton 8124 Installation instructions and owner's manual

Wayne-Dalton

Wayne-Dalton 8124 Installation instructions and owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

www.GenieCompany.com/commercial | 800.843.4084
GCL-MH operators are covered by the following U.S. patents: 7355363, 7878931, 8014966
The GCL-MH is designed for high or full-lift
sectional and rolling doors that have a limited-duty
cycle requirement. Advanced features and robust
mechanical design combine to provide a medium-duty
operator that is the new standard in the industry.
UL325-2010 APPROVED
• Allowsformonitoredentrapmentprotectionandmomentary
operationwhenusedwithselectphotoeyesand/or
edge-sensingdevices.
• Seebackforapprovedlistofmonitoreddevices.
GCL-MH Advantages
• Ratedfor15cyclesperhouroperation,maximizingthe
performanceofamedium-dutyoperator.
• Modulardesignwithoptionalexpansionboardsforadvanced
timertoclose,andauxiliaryoutputfunctionality.
• Optional:Intellicode®Iplugandplayreceiverlearnsupto50
transmitters.Learnanddeleteindividualtransmittersdirectly
fromLCDdisplay.
• TensiBelt™primarydrivereductioneliminatesneedtoadjust
belttension.
• Availableineither115Vor230VAC1Ø60Hz.Expandedoffering
increasesapplicationsavailableformedium-dutyuse.
• Motorwithbuilt-inthermalprotectionandballbearingdriveend.
Providesoverloadprotectionandbearingsextendlifeofmotor
overtypicalbushings.
• LCDdisplaywithintuitivesetupmenu.Providesreal-timestatus
andtrouble-shootingassistance.
• Open/close/stopandsetupkeysincludedoncontrolboard.
KeepsallcontrolsneartheLCDdisplayconvenientforsetup.
Standard Features
• Opticallimitsystemwithlineartravelnuts.
• Maxruntimerautomaticallyadjuststoupanddownruntime.
• TensiBelt™primaryreduction.
• Delayonreverse.
• 16-characterLCDdisplay.
• UL325-2010approved.
• 3-buttoncontrolstation.
• 2-year/20,000-cyclewarranty.
• Programmablemid-stop.
• Emergencyhoistformanualoperation.Availableinrighthandonly.
GENIE®
COMMERCIAL OPERATORS
GCL-MH
MEDIUM-DUTY HOIST OPERATOR
www.GenieCompany.com/commercial | 800.843.4084
©2012 The Genie Company | GCL-MHss
13 7
8
"
13 13
16
"
611
16
"
71
8
"
65
8
"
SECTIONAL WALL MOUNT
19 5
8
"
33
4
"
315
16
"
10 15
16
"
17"
19 5
8
"
18 1
2
"
9
16
"
8"
2"
12"
97
16
"
47
8
"
MOUNTING DIMENSIONS
REVISIONS
ER
REV DESCRIPTION
DATE
APPROVAL
501348
-
ORIGINAL ISSUE
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
E
F
E
F
GMXH TECHNICAL INFO
-
NOTES: (UNLESS OTHERWISE SPECIFIED)
11/10/11
FINISH
MATERIAL
HOLES:
< Ø.251 =
.003
Ø.251-Ø.500 =
.003
> Ø.500 =
.003
112212
INCHES
WDR
10/19/2011
WDR
11/9/11
DO NOT SCALE
A SUBSIDIARY OF OVERHEAD
DOOR CORPORATION
TOLERANCES:
DRAWN
112212-GMXH-SECT
INTERPRET DIMS & TOLS
PER ASME Y14.5M
DIMS CIRCLED WITH
SYMBOL '

' ARE CRITICAL
TO QUALITY DESIGN
FEATURES & MUST MEET
APPLICABLE IN-PROCESS
INSPECTION STANDARDS.
ALL DIMS ARE IN
UNLESS OTHERWISE SPECIFIED
SCALE 1:2
DWG NO.
SIZE
DESCRIPTION
APPROVALS
DATE
ALL GEOMETRY GOVERNED BY 3D CAD DATABASE
:
APPROVED
CHECKED
.X = ±.1
.XX = ±.01
.XXX = ±.005
ANGULAR = ±1
SHEET 1 OF 2
THIRD ANGLE PROJECTION
ALLIANCE, OHIO
D
PLOTTED: 10/19/11
MS
THE DRAWINGS AND ALL OTHER
INFORMATION CONTAINED HEREIN ARE
THE CONFIDENTIAL PROPRIETARY
PROPERTY OF OVERHEAD DOOR
CORPORATION, INCLUDING ITS
AFFILIATED SUBSIDIARIES AND
AFFILIATES. THIS DRAWING
INFORMATION, IN WHOLE OR IN PART,
MAY NOT BE COPIED IN ANY MANNER OR
DISCLOSED TO ANYONE WITHOUT PRIOR
WRITTEN CONSENT OF OVERHEAD DOOR
CORPORATION. DISCLOSURE OF ANY
DRAWING OR INFORMATION IS INTENDED
NOT TO AND SHALL NOT OPERATE AS A
LICENSE OR AUTHORIZATION TO USE IT
FOR ANY PURPOSE WITHOUT SPECIFIC
WRITTEN CONSENT OF OVERHEAD DOOR
CORPORATION.
P/N 112212-0001
GCL-MH |MEDIUM-DUTY HOIST OPERATOR
MAX DOOR SIZE (SQ*FT) - SECTIONAL
Door Series
Commercial Steel Insulated & Non-Insulated Thermospan®ThermoMark™Aluminum
216 216
Ins. 220 220 Ins. 2415 2415 Ins. 2411 2411 Ins. 125 150 200 200-20 5150 5200 451 452
Flush Ribbed Insulated Insulated
Model
Max
Door
Wt.
(lbs.)
16GA. 16GA.
Ins.
20GA.
Steel
20GA.
Ins. 24GA. 24GA.
Ins.
Nominal
24GA.
Nominal
24GA.
Ins.
PU-FIP PU-FIP
1.38”
PU-FIP
2”
PU-FIP
2”
20GA.
Ext.
PU-FIP
Raised
Panel
1.38”
PU-FIP
Raised
Panel
2”
1/8”
Glass
1.38”
1/4” or
1/2”
Glass
1.38”
1/2 HP 620 170 120 230 160 270 200 300 256 256 256 240 160 256 256 210 144
1.MaxDoorWeightandnotthesquarefootage,isthecriticalfactorinselectingtheproperoperator.
2.MaxDoorHeight16’
3.For“CommercialSteelInsulated”category,various“backer”optionsareavailable.Thechartaboveisbasedinallcasesonthethickestbackeravailable.
4.“PU-FIP”standsfor“polyurethane,foamed-in-place.”Ifnonotationispresent,insulationis“polystyrenelaid-in-place.”
Notes:
Accessories and Options
• Timer to Close Module
TimedclosesetviatheLCDdisplayfrom2secondsupto5minutes.Includes
pre-closewarningcontacts,timerholdinput,auxiliaryopeninput,normally
closedsafetyinput,andmonitorededgeinput.
• Auxiliary Output Module
Providesrelaycontactsattheopen,close,andmid-stoplimits.Contacts
for5-minutelamp,and“ADA”contactssetviaLCDdisplaytowarnduring
opening,closingorboth.
• 315Mhz Receiver Module
IntelliCode®Iradioreceiverthatis315Mhzandcapableofstoring50single-
buttonand/or50open-close-stoptransmitterswiththeabilitytoaddand/or
deletetransmittersindividually,identifyandstoreactivatingtransmitterID(s).
• UL325-2010 Approved Reversing Devices
Theinstallationofamonitoredexternalentrapmentdeviceisrequiredfor
momentarycontactcloseoperationonallcommercialdooroperators.Only
thefollowingdevices,whenpurchasedthroughGenie,areUL-Approvedfor
usetomeetthisrequirement:
• Safe-T-Beam®PhotoeyeKitwithadjustablebracketP/N38176R.S1
• Impact-protectedCommercialPhotoeyeKitP/NOPAKPE.S
• MillerEdgeME/MT/CPT(DCorT3)2-wireedgesensor.Mustbeused
withTCM(OPABTCGX.S)orInterfaceModule(OPAKMEIGX.S).
• Nema4PhotoeyesP/NOPAKPEN4GX.S
1— Default device when operator is ordered.
Construction
• Motor
1/2HP,ACcapacitorstart/runmotor.Motorreplaceablewithout
changinglimits.
• Brake
ACsolenoidactuatedbandbrake.
• Drive
Primary—TensiBelt™autotensioningpoly-VJbelt.
Secondary—chainandsprocketreduction.
• Friction Clutch
Adjustableclutchtohelpprotectagainstdoorand
operatordamage.
• Precision Radial Ball Bearings
Includedincriticalareasthroughoutthepowertrain.
• Emergency Hoist Manual Operation
Electricallyinterlockedmanualhoistwithoorleveldisconnect.
• Pre-wired to accept:
-Monitoredentrapmentdevicesuchasphotoeyes.
-Singleor3-buttoncontrolstations.
-Externalinterlockswitches
MAX DOOR SIZE (SQ*FT) - ROLLING
Door Series
Steel Non-Insulated Steel Insulated Counter Doors Grilles Sheet Door
16GA. 18GA. 20GA. 22GA. 24GA. 26GA. 18GA. 20GA. 22GA. Aluminum STL/SST Aluminum STL/SST 26GA.
Model
Max
Door
Wt.
(lbs.)
197 246 246 338 394 394 148 148 197 126 126 300 200 256
1/2 HP 580
Dealer Imprint Area
AMPERAGE RATING 1Ø 60Hz
HP 115V 230V
1/2 6.5 3.1