•For safety reasons, the device was designed with a motion sensor: if the working device detects
any movement within 3m, it will immediately deactive and a continuous audible dual beep and
flashing red and green LED indicator lights will engage.
•The motion detector can ‘see’ through walls, the range can be affected by different materials and
thickness (metal: isolated; concrete: decreased; glass or wood: no change; reflector: increased).
3. Installations
Wall Mounting
•Mount 2 screws (M4) on the wall with a distance of 1261.7mm to
hang the device.
Rigging
•Fix your hanging rods into the two rigging holes of the device.
(rigging holes diameter: 6mm)
*For safety reasons, always attach a safety cable between the handle of device
and another fixing point on the wall or ceiling.
4. Operation
•Switch on the device, the green power indicator light turns on.
•On the supplied remote control:
Press the <30 mins>, <60 mins> or <120 mins> button to select your
desired disinfection time.
Press the Start button, audible alarm starts beeping and red power
indicator will flash regularly for 2 minutes. You must exit within this 2
minutes.
•The UV tubes will light up once the beeping countdown ends, the power
indicator turns red and stays on during the entire disinfection process.
•Once the disinfection process ends, the power indicator switches to green.
Also an audible alarm sounds.
•Open the doors and windows to ventilate the disinfected area.
* If the remote control loses pairing with the device, re-do the pairing by pressing the Start
button on the remote control and switch on the device for 5 seconds.