1INTRODUCTIÓN
IMPORTANT NOTICE
SYSTEM CHARACTERISTICS
O
O
O
This instruction manual describes the assembly and wiring of audio door entry
systems with 4+N wires installation for residential complexes: several internal
buildigns and one or several general entrance door panels.
Do not use the instructions manuals included in the EL551 sound modules packages.
The installation diagram is also included in this instructions manual.
STARTING RECOMMENDATIONS
First of all we would like to thank and congratulate you for the purchase of this
product manufactured by Golmar.
The commitment to reach the satisfaction of our customers is stated through the
ISO-9001 certification and for the manufacturing of products like this one.
Its advanced technology and exacting quality control will do that customers and
users enjoy with the legion of features this system offers. To obtain the maximum profit of
these features and a properly wired installation, we kindly recommend you to expend a
few minutes of your time to read this manual.
O
O
O
Do not use excessive force when tightening the transformer connector screws.
Install the equipment without the power connected. Disconnect from power before
any system modification. Check that the input voltage is lower than 230Va.c.
Before to connect the system, check the connections between door panel and
telephones, and the transformer connection. Do always follow the enclosed
information.
O
O
O
O
O
O
O
O
Audio system with 4 + N wires installation.
Just 1 TF-104 transformer (12Va.c., 1.5A) will be required for each building door
panel and 2 units for each general entrance door panel.
Electronic call with acoustic acknowledgement signal.
Two selectable electronic call types at the door panel.
Luminous and acoustic busy channel acknowledgement signals.
a.c. lock releases activation.
Timed door open activation.
Up to three telephones in the same apartment.
All manuals and user guides at all-guides.com

3DOOR PANEL INSTALLATION
DOOR PANELS DESCRIPTION
eneral entrance door panel
Gdescription.
Note: each EL505 microprocessed circuit can
manage two internal door panels.
Use as many circuits as required.
The 3xx1 push buttons modules have a window
useful to show the name of the internal building
and a red light indicator that informs when
the channel is busy.
EL505
microprocessed
circuit(s)
Optional:
3xx1
push buttons module
with informative
window
2
2xxx
grille module
600
closing heads
3xxx
push buttons module
CE-6xx embedding boxes
CE-6xx embedding boxes
EL550
sound module
EL550
sound module
nternal door panel
Idescription.
2xxx
grille module
600
closing heads
3xxx
push buttons module
mbedding box positioning.
E
1650
1850
1450
The upper part of the door panel should be placed at 1,65m. height roughly. The hole dimensions
will depend on the number of door panel modules.
The door panel has been designed to be placed under most of the environmental conditions.
However it's recommended to take additional cautions like rainproof covers.
1
CE610
125
140
56
Modules
Model
W
H
D
2
CE620
1
257
56
25
3
CE630
125 mm.
374 mm.
56 mm.
reparing the cables entry.
P
Break the bottom flange to pass the cables through. In case of door panels
with more than one embedding box, break the side flanges and
attach the embedding boxes using UC junctions.
All manuals and user guides at all-guides.com

5
4
DOOR PANEL INSTALLATION
lace the embedding
Pbox.
Pass the wiring through the hole made in the bottom part
of the embedding box. Level and flush the embedding
box. Once the embedding box is placed, remove the
protective labels from the attaching door panel holes.
ssembly the door panel
Amodules.
Insert the header DOWN marked in the lower module and fix it by screwing the module
shafts.
Place the module spacer between lower and next modules, assuring that the spacer
adjustment notches are inside the panel. Fix the module by screwing the shafts.
Repeat this procedure in case of door panels with one more module (the maximum
number of modules placed vertically is three).
Insert the header UP marked in the last module and fix it by screwing the supplied screws.
DOOR PANEL INSTALLATION
ssembly the sound module.
A
Stick the waterproof seals on the upper and lower headers.
Insert the sound module in the grille module.
For a proper assembly, align the light
push button and the microphone rubber
of the sound module with its corresponding
holes in the grille module.
old the door panel on the
Hembedding box.
Select a direction to open the door panel; this selection should ease
the door panel wiring.
The opening direction will be settled through the hinges position,
that must be passed through the header clips as shown.
For example, if the hinges are placed on both clips of the lower
header, the door panel will open downwards; if they are placed
on the right clips of both headers, the door panel will open to left.
To hold the door panel on the embedding box,
insert the hinges in the embedding box lockers
as shown.
All manuals and user guides at all-guides.com

lacing the identifying label
Pof the 3xx1 window
7
6
ssembly and wiring of the EL505 microprocessed
Acircuits in the general entrance door panel(s).
These circuits are to be assembled on the top
of the embedding box. Insert the circuit in
the top flanges of the embedding box (1).
Push-in the circuit in the bottom flanges (2)
by pressing the pcb board.
To assembly more than one EL505 circuit in
the same embedding box, fix the second
circuit by screwing the top tab of the case
to one of the plastic lugs of the embedding
box.
Link the EL551 sound module with the EL505 microprocessed circuit by using the supplied
flat cable. In door panels with more than one EL505 circuit, connect all the circuits by
linking flat cables.
To link flat cables remove the protection plug and connect to the next
cable. If the circuits are placed in different embedding boxes,
pass the cable through the embedding box junctions.
Don't remove the protection plug of the last cable
as prevention against the humidity.
ush buttons wiring.
P
Before to wire the window module circuits,
the indetifying label must be placed.
Insert a plain screwdriver into the slots and
lever to remove the pcb board.
Once the label has been placed, assembly
the pcb board again.
The connection of the circuit terminals is
shown on page 14.
DOOR PANEL INSTALLATION DOOR PANEL INSTALLATION
For a quality finish, pass the push buttons wires through
the spacer hole of the closest module.
IMPORTANT: link the common terminal of the push buttons
corresponding to the same internal building. This wire
must be connected to the corresponding CP terminal
of the EL505 microprocessed circuit.
The common terminal of the push buttons contained in a
module are linked from factory; in case that one module
contains push buttons that call to different internal
buildings, separate the common terminal.
Twist the independent call wires as shown.
All manuals and user guides at all-guides.com

89
lace the nameplate labels.
P
Open the label holder.
Place the label and
close.
inal
Fadjustments.
If after starting the system it's considered that the audio
volume isn't correct, proceed with the necessary
adjustments as shown.
Once the nameplate labels are placed, wire the
lamps from different modules and connect them
to terminals L1 and L2 of the sound module,
as it's shown on the installation diagrams.
all type
C
selection.
EL551 sound modules have a jumper placed on the right side
of the terminal connector. This jumper allows to select between
two different call types. Set the same type of call on all the
internal panels and the other type on the general entrance
panels. This function will allow the user to distinguish
which door panel is calling.
DOOR PANEL INSTALLATION DOOR PANEL INSTALLATION
lose the door
Cpanel.
Fix the door panel by using the supplied
screws.
Finish the door panel assembly by pressing
the closing heads.
LOCK RELEASE INSTALLATION
ock release installation.
L
If the lock release will be installed in a metal door, use a
Ø3,5mm. drill and tap the hole. In case of wood door,
use a Ø3mm. drill.
M 4 x 8
f3,5 x 25
DIN-7972
DIN-963
All manuals and user guides at all-guides.com
all-guides.com

10
SYSTEM OPERATION
11
a
d
c
e
e
g
f
b
O
O
To make a call the visitor should press the push button corresponding to the
apartment he wishes to contact. An acoustic tone will be heard confirming the
call as the push button is pressed. At this moment the call will be received at the
telephone in the dwelling.
If the call has been made from a general entrance door panel, the
corresponding internal door panel will be automatically disconnected, and its
light push button will change to red color: if a visitor tries to call from this internal
door panel an acoustic tone will be heard confirming the system is busy.
If the call has been made from a internal door panel, the push buttons of the
general entrance panel corresponding to this internal building will be
disconnected: if a visitor tries to call to a telephone of the busy internal panel an
acoustic tone will be heard confirming this internal panel is busy.
In case that the general entrance panel contains 3xx1 window modules, the
busy status will be also showed on the corresponding window.
If the call is not answered in 30 seconds, the system will be freed.
To establish communication pick up the telephone handset. The communication
will last for one and a half minutes or until the handset is replaced. Once the
communication has finished the system will be freed.
OTo open the door, press the door release push button during call and
communication progresses: with one press, the door release operates during 3
seconds.
TELEPHONE INSTALLATION
escription of the T-900
Dtelephone.
a.
b.
c.
d.
e.
f.
g.
Telephone handset.
Speaker grille.
Microphone hole.
Subjection hole.
Telephone cord connectors.
Door release push button.
Hook switch.
To open the telephone insert
a plain screwdriver into the slots and
rotate it as shown.
Avoid to place the telephone near to heating sources,
in dusty locations or smoky environments.
The telephone can be fixed using an electrical embedding
box or directly on the wall, as shown on the picture.
If the telephone will be installed directly over the wall,
drill two holes of Ø6mm. on the specified positions,
using 6mm. wallplugs and Ø3,5 x 25mm. screws.
Pass the installation wires through
the corresponding hole and
connect them as shown on the
installation diagrams.
Close the telephone as shown on the picture.
Once the telephone is closed, connect the handset
using the telephone cord and put it on the craddle.
POWER SUPPLY INSTALLATION
nstalling the TF-104 transformer.
I
To install the transformer directly on the wall,
insert the fixing flanges.
Drill two holes of Ø6mm. and
insert the wallplugs.
Fix the transformer with the specified
screws.
The transformer can be installed on a DIN guide (3 units) simply pressing it.
To disassemble the transformer from the DIN guide, use a plain screwdriver to lever
the flange as shown on the picture.
The transformer must be installed in a dry and
protected place. It's recommended to protect
the transformer by using a thermo-magnetic
circuit breaker.
DIN 46277
f
DIN-7971
3,5 x 25
3,5 x 25
DIN-7971
f
All manuals and user guides at all-guides.com

INSTALLATION DIAGRAM
13
INSTALLATION DIAGRAM 12
ind. 1a
ind. 2a
0
0
10
10
5
5
3
3
P1
P1
CVCVINHCOCP
ind. 1a
ind. 2a
ind. 3a
P
CN1
-
TF-104
EL-551 JP1 JP1
Building A
SEC
~~
PRI
~~
Main
ind. 1a
ind. 2a
ind. 3a
ind. 1b
ind. 2b
0
0
10
10
5
5
3
3
P1
P1
CVCVINHCOCP
ind. 1b
ind. 2b
ind. 3b
P
CN1
-
TF-104
EL-551
SEC
~~
PRI
~~
Main
ind. 1b
ind. 2b
ind. 3b
CVCVINHCOCPL1 L2 P
-
SEC
~~ ~~
Main
CN1 PRI
TF-104
EL-551 JP1
Main
SEC
~~~~
PRI
TF-104
CP CPA1 B1CO COA2 B2+V P P
- -
~1 ~2
CN1 EDIFICIO / BLOCK A EDIFICIO / BLOCK B
EL505
GENERAL ENTRANCE
A B
Building B
In case of more than one EL505 circuit
only the first unit must be powered
from the TF-104 transformer.
To power the rest of circuits, link +V terminal
of all the EL505 circuits.
eneral entrance door
Gpanel and two internal
L1 L2 ~1~2 L1 L2 ~1~2
~1~2
All manuals and user guides at all-guides.com

OPTIONAL CONNECTIONS 14 SECTIONS CHART
15
ind.
0 010 105 53 3P1 P1
xternal lock release activation.
E
ections chart.
S
inking 3xx1 modules.
L
A1 B1A2 B2 L1 L2
1 1L12 2L2 L1 L2
EL505
A window B window
EL551
If the general entrance door panel contains
3xx1 window modules to show the busy
status (see pages 2 and 7), connect the
window circuits as shown.
arallel telephones installation.
P
The maximum number of telephones placed
in the same apartment is three.
For each telephone placed in parallel
the section corresponding to the call wire
must be doubled.
The lock release can be activated at any moment
by using an external push button,
that must be connected between ' 1' y 'CV' terminals
of the corresponding door panel sound module.
This function will allows to exit from the building
being not necessary the use of a key.
~
0, ind, 5, , 10, , P, P1, CO 0,25mm² 0,50mm²
0,50mm² 1,00mm²
1,00mm² 2,50mm²
100m. 300m.
–, 3
~1, ~2, CV
For longer distances than the specified contact with your distributor.
Terminal
Distance
CVCVINH ~1~2
All manuals and user guides at all-guides.com

TROUBLESHOOTING HINTS 16
ONothing operates.
wCheck the output transformer voltage between SEC terminals: it should have 12
to 17Va.c. If not, disconnect the transformer from the installation and
measure again. If it's correct now, it means there is a short circuit in the
installation: disconnect the transformer from mains and check the installation.
OInappropriate audio level.
wAdjust the level volumes as shown on page 6. In case of feedback, reduce the
audio levels until feedback fade out.
ODoor open function no operates.
wRemember that this function is only available during call and communication
progresses.
wDisconnect the lock release from the sound module and short-circuit terminals ' '
and 'P' of the sound module or of the EL505 circuit: at that moment the output
voltage between 'CV' terminals of the sound module should be 12Va.c. If it's
so check the lock release, its wiring and the wiring of the terminal 'P' to the
telephones. If these tests don't solve the problem, replace the sound module.
ONo telephones receive the call or acknowledgement call signal is not reproduced.
wCheck that the push buttons common terminal are correctly connected to the
'CP' terminal of the sound module (in case of internal door panels) or to the
corresponding 'CP' terminal of the EL505 circuit (in case of general door
panels).
OFrom the moment a call is made on the general entrance door panel, the voltage
between '-' and 'CO' terminals of the internal called door panel should be
lower than 3Vd.c. If not, check the continuity of the 'CO' wire. The same
status should be occurs if the call is made from a internal door panel.
OOnce a communication is finished the system remains on busy status.
wIf the busy status remains for a three minutes period, even if the handset of the
called telephone is on the craddle, check that all the telephones are
correctly replaced.
OThe acknowledgement busy signal is not reproduced.
wWhen someone tries to make a call during busy status, the light push button
should change its color and busy signal should be heard at the door panel. If
the called telephone is not a T-900 model, and is not correctly replaced or it
is in communication, the busy signal will not be reproduced.
ONOTE: in case of any problem, check that the connection between the sound
module and the EL505 microprocessed circuit, through the flat cable, is
–
All manuals and user guides at all-guides.com
Table of contents
Other golmar Intercom System manuals

golmar
golmar PE-90-MS/6 User manual

golmar
golmar T500ML User manual

golmar
golmar SHINER-90 User manual

golmar
golmar m700 User manual

golmar
golmar M201 User manual

golmar
golmar T-540 Uno User manual

golmar
golmar ART 4/G2+ Monitor User manual

golmar
golmar T631/PLUS User manual

golmar
golmar Rock Series User manual

golmar
golmar VESTA7 GB2 User manual

golmar
golmar Vista Nexa User manual

golmar
golmar Rock Series User manual

golmar
golmar Art 7H/G2+ User manual

golmar
golmar G2+ User manual

golmar
golmar G2+ User manual

golmar
golmar 295 Series User manual

golmar
golmar NEXA Series User manual

golmar
golmar Rock T222EN User manual

golmar
golmar SOUL 7W KIT User manual

golmar
golmar GB2 Nexa Modular User manual