5.ACCESS TO PROGRAMMING
To perform the dierent programming sequences, it is necessary to manipulate the programming switch:
gate controller
PROG/EXPL
1ON
ON
1
6.PROGRAMMING
7.STATUS LEDs MEANING
1. Move the controller SW to position 1 (prog).
2. e red led on the reader will light up. Each time a key or card is swiped through the reader, the red led will turn green and red.
3. Aer programming the master cards (maximum 10), move the SW to position ON (Expl).
1. Present one of the master cards for 5 seconds on the front of the reader until its red LED lights up.
2. Present the resident cards one by one. For each new card presented, the LED will change status to green, then to red for a short period.
3. Aer the last resident key to be programmed has been presented, present the master card to exit programming. e led on the reader
will turn o.
1. Present one of the master cards on the front of the reader for 5 seconds until the red LED on the reader lights up.
2. Present the resident card to be removed in the reader for 5 seconds, until the LED turns from red to green. If you want to erase any
other resident card, repeat the process.
3. Aer the last resident key to be deleted has been presented, present the master card to exit programming. e led on the reader will
turn o.
1. Move the SW of the controller to position 1 (prog), leave the output button pressed for 5 seconds until the red LED on the controller
starts ashing (3 times per second).
2. Move the SW to the ON (Expl) position.
3. All resident cards will be deleted.
1. Remove power and move the controller SW to position 1 (prog).
2. Press and hold the “output pushbutton” while powering and hold for 5 seconds (steady red led). Move the SW to ON (Expl) the red
led will ash slowly.
3. All master cards will be erased.
1. Move the SW to position 1 (prog). e red Led of the controller will light up.
2. Using the output pushbutton it is possible to give the desired number of pushes for the opening in seconds (e.g.: 5 pushes equals 5 seconds).
3. Move the SW to the ON position when nished.
e controller uses two types of cards or keyfobs: Master and resident. e “resident” cards open the door and the “master” cards are used
to enroll the “resident” cards.
6.1.ADD MASTER CARDS (MAX.10)
6.2.ADD RESIDENT CARDS (MAX.1500)
6.3.REMOVE RESIDENT CARDS
6.4.REMOVE ALL RESIDENT CARDS
6.5.REMOVE AL MASTER CARDS
6.6.MODIFY OPENING TIME
LED EASYGATE CONTROLLER
RED LED OFF Controller out of service (no power supply or failure).
RED LED FLASHING FAST (3 times per second) Communication problems between the reader and the controller (check cable connection).
RED LED SLOW FLASHING (1 time every 3 seconds) Successful communication between the reader and the controller.
GREEN LED ON Correct power supply
LED READER
GREEN AND RED LIGHTING In case the reader’s LED lights rst green and then red when powered, the connection is correct.
RED AND GREEN FAST LIGHTING In case the reader LED lights up red rst and then green when powering it, the connection is wrong.