1
INTRODUCTION
STARTING RECOMMENDATIONS
OThe installation and handling of this equipment must be performed by authorised personnel.
OInstall or modify the equipment without the power connected.
ODo not overtighten the screws on the terminal block of the SU-R5 relay unit.
OThe entire installation must be at least 40 cm away from any other wiring.
OBefore connecting the device, check the connections between the door panel, SU-R5 relay unit,
distributors, Tekna R5 Col SU-R5 monitors, T-530/R5 SU-R5 telephones and the connection of the
power supply unit(s).
OAlways follow the instructions contained in this manual.
CONTENTS
First of all we would like to thank you and congratulate you for purchasing this product
manufactured by Golmar.
Our commitment to satisfying our customers can be seen from our ISO-9001 certification and from the
manufacturing of products like this one.
Its advanced technology and exacting quality control will ensure that customers and users enjoy the many
features this system offers. To obtain the maximum benefit from these features and a properly wired
installation, we kindly recommend that you spend a few minutes of your time reading this manual.
Introduction........................................................................................................................... 1
Index.....................................................................................................................................1
Starting recommendations.......................................................................................................1
Safety precautions..................................................................................................................2
System characteristics.............................................................................................................2
System operation................................................................................................................... 3
Operating modes.....................................................................................................................
With 1 relay unit without AP function" " ..................................................................................4-6
With 1 relay unit and AP function" " .......................................................................................7-8
With 4 relay units without AP function" " ................................................................................9-11
With 4 relay units and AP function" " .......................................................................................12
With 1 relay unit, AP function and porter's exchange" " ..............................................................13
Description..........................................................................................................................14
Installation............................................................................................................................14
DIP switch configuration........................................................................................................15
Status LEDs..........................................................................................................................15
Optional connections...............................................................................................................
External AP lock release button" " ............................................................................................16
Connection of AC lock release.............................................................................................16
Connection of camera........................................................................................................16
Installation diagrams................................................................................................................
Installation with 1 relay unit without AP and several access panels" " ......................................17-18
Installation with 4 relay units with AP and several access panels" " ..........................................19-22
OSU-R5 relay unit for the Vista Plus and Vista Nexa system.
OUp to 6 access door panels.
OUp to 4 relay units in cascade (per channel).
OThe addresses of the relay units connected must be correlative.
OInstall the relay unit(s) between the vertical and the door panel.
OBetween the door panel and the relay unit(s), no element must be connected.
OThe converter for porter's exchange, distributors, monitors and telephones (SU-R5) should be
connected to the output of the last relay unit.
OMaximum distance between the power supply and the furthest monitor: 50m.
OMaximum distance between the door panel and the furthest monitor 50/100m (depending on the
location of the power supply unit).
OFA-PLUS/C power supply unit connected to the relay unit.
OMaximum distance between the power supply and the relay unit: 3m and a section of 1.5mm (mount
in the same location).
O"AP"If the function is used, each relay unit and door panel will have its own power supply unit (see
pages 7-8 and 12-13).
O"AP"If the function is not used, the (master) access door panel nearest the upright can share the
power supply of the relay unit or the vertical (see pages 4, 6, 9 and 11).
OThe (slave) access door panels will have their own power supply units.
OIt is necessary for the panel to have a power supply unit if an EL502 AC/DC converter module is used
to connect an AC lock release (Stadio panel only).
OConfiguration DIP switch to indicate:
wRelay unit lock release activation time (3, 6, 9 or 12 seconds).
wRelay unit address, must be correlative (address 1, 2, 3 and 4).
wWhether a camera is connected to the relay unit.
OOutput for Golmar 12V AC or DC lock release activated by a potential-free relay (if a 12V AC lock
release is used, a TF104 transformer must be fitted to the relay unit).
OInput for the relay unit's external lock release button.
OOutput for activating a camera in the relay unit (connection with coaxial cable, maximum 0.5A).
OStatus LEDs.
2SAFETY PRECAUTIONS
2
O.The installation and handling of this equipment must be performed by authorised personnel
OInstall or modify the equipment without the power connected.
ODo not overtighten the screws on the terminal block of the SU-R5 relay unit.
O.The entire installation must be at least 40 cm away from any other wiring
OInstall the SU-R5 relay unit in a dry and protected place without risk of drip or water. projections.
OAvoid to place it near to heating sources, in dusty locations or smoky enviroments.
ODo not block ventilation holes of the unit so that air can circulate freely.
OTo avoid damage, the relay unit must be firmly fixed.
SYSTEM CHARACTERISTICS