INTRODUCTION
First and foremost we would like to thank you for purchasing this product.
Our commitment to satisfying our customers can be seen from our ISO-9001 certification and from the manufacturing of
products like this one.
Its advanced technology and exacting quality control will ensure that customers and users enjoy the many features
this system offers. To obtain the maximum benefit from these features and a properly wired installation, we kindly
recommend that you spend a few minutes of your time reading this manual.
CONTENTS
2
SAFETY PRECAUTIONS
-Always disconnect the power supply before making modifications to the device.
-The fitting and handling of these devices must be carried out by authorised personnel.
-The wiring must run at least 40cm away from any other wiring.
-Do not overtighten the screws on the terminal block.
-Install the SAR-GB2 relay unit in a dry and protected location free from the risk of dripping or splashing water.
-Install the SAR-GB2 relay unit and SAR-12/24 together with the FA-GB2A power supply unit.
-Do not place in humid, dusty or smoky locations, or near sources of heat.
-The maximum consumption of relay contacts shall not exceed from 2Ato 30 Vdc/ 1.25Ato 48 Vac.
-Before connecting the system to the mains, check the connections.
- .Always follow the instructions contained in this manual
Introduc ....................................................................................................................................................................2tion
Contents........................................................................................................................................................................2.
Safety precautions........................................................................................................................... .................2............. .
Characteristics...............................................................................................................................................................2
Operating modes.............................................................................................................................................. 3..............
Description of SAR-GB2 relay unit....................................................................................................................................
Description.......................................................................................................................................................... .......4. .
Installation................................................................................................................................................................... .... .
Detail of the installation of the SAR-GB2 relay unit....................................................................................................... 4.
Operating mode configuration...................................................................................................................... 5................
Operating mode description “Lock release relay”........................................................................................... 5...............
Assigning of door panel and lock release control 1 or 2.............................................................................................. 5.
Relay unit lock release activation time....................................................................... ......6..........................................
Operating mode description “Stairs light activation relay”..................... ..................................................... .7.... .............. .
Relay unit light activation time.......................................................................................... 7..........................................
Wiring diagrams................................................................................................................................................. ..............
Stairs light activation relay.................................................................................................................................... .... 8... .
Additional lock release activation relay.........................................................................................................................8
Not s.............................................................................................................................................................................9e .
CHARACTERISTICS
-Digital relay for the system, allows the following operating modes:GB2
OStairs light activation relay (necessary module SAR-12/24).
OGolmar additional alternating lock release relay (necessary power supply unit TF-104).
- .Necessary to configure operating mode of the SAR-GB2 relay unit
- .Connects to the Bus paneldoor
- .Configuration DIP switch
- .Operating status LEDs
-The maximum consumption of relay contacts will be from 2Ato 30 Vdc (40w) / 1.25A to 48 Vac (40w).
-12Vdc output to activate SAR-12/24 module in operating mode “stairs light activation”.
RELAY UNIT TSAR-GB2

3
-This operating mode allows activation of the stairs light from the apartment.
It is activated through the push button of the telephone T-562 GB2 or Nhea GB2 and from the monitor light
function Vesta2 or Thera., Vesta7, Pentha
-See user manual for telephone or monitor installed in the apartment.
OPERATING MODES
RELAY UNIT TSAR-GB2
Stairs light activation relay (necessary module SAR-12/24):
Access paneldoor GB2
Mains
100~240Vac
FA- 2GB /A SAR-GB2 SAR-12/24
Cn
Bus Monitors
2
To stairs light
push button
*
( ) Neutral point of the power supply of the stairs light is connected in series through the relay contacts of the SAR-12/24.
220Vac/
1.8A max.
*
( )
IMPORTANT: For the description, installation, configuration and programming of the system, see the corresponding manual.
2
-This operating mode allows activation of a Golmar additional alternating lock release. This lock release is activated as
lock release 1 or lock release 2 and with the panel that has been assigned (through configuration in SAR-GB2) during
a call or communication process.
orIt will be activated through the push button (lock release 1 or lock release 2 respectively) of telephone
T-562 GB2 or Nhea GB2 and through the push button for lock release 1 (or through the push button for lock release
2 of the Vesta7 monitor) , Penthaor through the menu for lock release 2 of the Vesta2 or Thera monitor (for lock release 2 it is
necessary to enable function 2nd lock release on monitor, see user manual for the monitor installed in the apartment)Vesta2 .
- .See user manual for telephone or monitor installed in the apartment
Additional lock release activation relay (necessary power supply unit TF-104):
Access paneldoor G 2B
Mains
100~240Vac
FA- 2GB /A SAR-GB2 TF-104
Cn
Bus Monitors
2
Additional Vac
lock release *
( )
2
TF-104
Mains
100~240Vac
2
*
( ) The power supply of the lock release is connected in series through the SAR-GB2 relay contacts.
IMPORTANT: For the description, installation, configuration and programming of the system, see the corresponding manual.
2
22 2
2
22

DESCRIPTION OF SAR-GB2 RELAY UNIT
4
Descrip :tion
RELAY UNIT TSAR-GB2
POWER IN-USE
BUS BUS
.
.
SAR-GB2
CN.C PAP
N.A 12+
CONTACTOS RELE /
RELAY CONTACTS
1,25 A 48 V ~ (Máx. 40w)
2 A 30 V (Máx. 40w)
UNIDAD DE RELÉ
RELAY UNIT
a.
b.
c.
d.
12Vdc and “AP” output connector.
Relay contact connector.
Label.
JP (do not use)jumper .
Status LED (power supply).
Status LED (active).
.
SW1 dip switch
DIN rail latch release.
e.
f.
g.
h.
a
d
c
e
b
g
f
h
The relay unit can be mounted onto a DIN rail
(4 elements) by applying slight pressure.
To remove the relay unit from the rail, use a flat
screwdriver and lever it off, as shown in the
drawing.
Install the relay unit in a dry and protected location free from the risk of dripping or splashing water.
DIN 46277
Install the SAR-GB2 relay unit and SAR-12/24 together with the FA-GB2A power supply unit.
INSTALLATION
Detail of the installation of the relay unit:
POWER IN-USE
BUS BUS
.
.
SAR-GB2
CN.C PAP
N.A 12+
CONTACTOS RELE /
RELAY CONTACTS
1,25 A 48 V ~ (Máx. 40w)
2 A 30 V (Máx. 40w)
UNIDAD DE RELÉ
RELAY UNIT

INSTALLATION
5
Operating mode configuration:
Relay unit allows 2 operating modes:
-Activation stairs light relay (necessary module SAR-12/24).
-Golmar additional alternating lock release relay (necessary power supply unit TF-104).
The relay unit is factory-setting in “lock release relay” operating mode.
Operating mode configuration:
Step Remove the power supply from the SAR-GB2 relay unit by removing the relay unit Bus connector (The power
1:
supply status LED will turn off).
Step Set DIP1 to ON, DIP2 to ON and DIP3 to OFF. On the dip switch Sw1 situated at the rear
2:
.of the relay unit
Step On the power supply connector, join with a cable the terminals '-' and 'AP'
3: .
Step Connect the power supply to the SAR-GB2 relay unit by inserting the relay unit Bus connector. (LED showing4:
the power supply status will turn on).
Step In the first 5 seconds after connecting the power supply to the relay unit, move DIP1 from ON to OFF 4 times5:
consecutively.After this the “in use” status LED will indicate:
-Status LED “in use”: 1 flash indicates that the operating mode is in Light activation relay.
-Status LED “in use”: 2 flashes indicates that the operating mode is in Lock release relay.
Step Remove the power supply from the SAR-GB2 relay unit (see step 1).
6:
Step Set DIP1, DIP2 and DIP3, as defined in the configuration:·7:
-Operating mode lock release relay: See assigning of door panel and lock release control 1 or 2.
-Operating mode light activation relay: DIP1, DIP2 and DIP3 should be set to OFF.
Step Remove the cable which joins the terminals '-' and 'AP'.
8:
Step Connect the power supply (see step 4).9:
Step Check that the operating mode is correct, activating the light or lock release depending on the configuration10: .
Note: Repeat the procedure (steps 1 to 10) until the relay unit has been configured to the desired operating mode.
Continued overleaf
RELAY UNIT TSAR-GB2
1
2
3
ON
Operating mode “Lock release relay”:
-This operating mode allows activation of a Golmar additional alternating lock release. This lock release is activated as
lock release 1 or lock release 2 and with the panel that has been assigned (see assigning relay unit to panel and lock
release) during a call or communication process.
It will be activated through the push button r (lock release 1 or lock release 2 respectively) of telephoneo
T-562 GB2 or Nhea GB2 and through the push button for lock release 1 (or through the push button for lock release
2 of the Vesta7 monitor) , Penthaor through the menu for lock release 2 of the Vesta2 or Thera monitor (for lock release 2 it is
necessary to enable function 2nd lock release on t monitor, see user manual for the monitor installed in the apartment).Ves a2
-See user manual for telephone or monitor installed in the apartment.
1
2
3
ON
Relay unit assigned to access panel 1 and lock release 1.door
1
2
3
ON
Relay unit assigned to access panel 1 and lock release 2.door
The relay unit should be assigned to one of the 4 access panels that the system allows and define the push button
of lock release 1 or 2 of the telephone / monitor that will activate the relay unit.
Note: For the relay unit to activate in this operating mode, the assigned panel must be in a call or communication
process.
Assigning of door panel and lock release control 1 or 2.

6
Continued from the previous page.
RELAY UNIT TSAR-GB2
INSTALLATION
1
2
3
ON
Relay unit assigned to access panel 2 and lock release 1.door
1
2
3
ON
Relay unit assigned to access panel 2 and lock release 2.door
1
2
3
ON
Relay unit assigned to access panel 3 and lock release 1.door
1
2
3
ON
Relay unit assigned to access panel 3 and lock release 2.door
1
2
3
ON
Relay unit assigned to access panel 4 and lock release 1.door
1
2
3
ON
Relay unit assigned to access panel 4 and lock release 2.door
Relay unit lock release activation time.
Configuration:
Step Remove the power supply from the SAR-GB2 relay unit by removing the relay unit Bus connector (The power
1:
supply status LED will turn off).
Step Connect the power supply to the SAR-GB2 relay unit by inserting the relay unit Bus connector. (LED showing
2:
the power supply status will turn on).
Step In the first 5 seconds after connecting the power supply to the relay unit, bypass the terminals '-' and 'P' with a
3:
cable for 3 seconds (the status LED “in use” will flash).
Step Next, bypass the terminals '-' and 'AP' with a cable for 3 seconds (the status LED “in use” will light up
4:
continuously).
Step Bypass the terminals '-' and 'P' again. The time that the terminals '-' and 'P' are bypassed will configure the
5:
activation time of the relay unit (every flash of the status LED “in use” is equivalent to one second of the activation
time). The maximum configurable time is 30 seconds.
Step After removing the bypass from the terminals '-' and 'P', the time that has been configured will be saved and the
6:
relay unit will come out of time configuration mode.
Step Check that the activation time of the relay unit is correct.
7:

7
RELAY UNIT TSAR-GB2
Operating mode “Stairs light activation relay”:
-This operating mode allows activation of the stairs light from the apartment.
It is activated through the push button of the telephone T-562 GB2 or Nhea GB2 and from the monitor light function
Vesta2 or Thera., Vesta7, Pentha
-See user manual for telephone or monitor installed in the apartment.
-The dip switch SW1 of the relay unit must be configured with DIP1, DIP2 and DIP3 set to OFF.
-Maximum of one relay unit per system.
- .Note: Once the relay unit has been activated, by default it will deactivate automatically after 1 minute
Relay unit light activation time:
Configuration:
Step Remove the power supply from the SAR-GB2 relay unit by removing the relay unit Bus connector (The power
1:
supply status LED will turn off).
Step Connect the power supply to the SAR-GB2 relay unit by inserting the relay unit Bus connector. (LED showing
2:
the power supply status will turn on).
Step In the first 5 seconds after connecting the power supply to the relay unit, bypass the terminals '-' and 'P' with a
3:
cable for 3 seconds (the status LED “in use” will flash).
Step Next, bypass the terminals '-' and 'AP' with a cable for 3 seconds (the status LED “in use” will light up
4:
continuously).
Step Bypass the terminals '-' and 'P' again. The time that the terminals '-' and 'P' are bypassed will configure the
5:
activation time of the relay unit (every flash of the status LED “in use” is equivalent to 30 seconds of the activation
time). The maximum configurable time is 900 seconds.
Step After removing the bypass from the terminals '-' and 'P', the time that has been configured will be saved and the
6:
relay unit will come out of time configuration mode.
Step Check that the activation time of the relay unit is correct.
7:
Note: The relay unit by default has a configured activation time of 1 minute.
1
2
3
ON
INSTALLATION

8
RELAY UNIT TSAR-GB2
WIRING DIAGRAMS
Stairs light activation relay:
220 Va /c
1.8A max.
SAR-12/24
F
N
IN IN
NC NA C To stairs light push button
Access paneldoor
Mains
100~240Vac
N L
CN
BUS (M) BUS(PL)
FA- 2GB /A
L
SAR-GB2
BUS BUS
CN.C PAP
N.A 12+
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relay 2
Relay 1
_
12Vdc
Lock release
max. 12 Vdc/270mA. AP
*
( )
To telephones /
monitors
Neutral point of the power supply of the stairs light is connected in series through the relay contacts of the SAR-12/24.
IMPORTANT: For the description, installation, configuration and programming of the system, see the corresponding manual.
*
( )
~~ ~~
Vac. lock release
TF-104
Main
PRI SEC
Golmar additional alternating lock release relay:
Access paneldoor
Mains
100~240Vac
N L
CN
BUS (M) BUS(PL)
FA- 2GB /A
L
SAR-GB2
BUS BUS
CN.C PAP
N.A 12+
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relay 2
Relay 1
_
12Vdc
Lock release
max. 12 Vdc/270mA. AP
To telephones /
monitors
IMPORTANT: For the description, installation, configuration and programming of the system, see the corresponding manual.
Important:
The minimum section of the cables
connecting the output terminals
of the relay SAR-12/24 is 1.5mm .
2

NOT S:E
9
RELAY UNIT TSAR-GB2

golmar@golmar.es
www.golmar.es
Sistemas de comunicación S.A.
Golmar se reserva el derecho a cualquier modificación sin previo aviso.