Grace Industries MS2000X Series Operation manual

MS2000X
User Information
The MS2000X is an Emergency Signaling Monitoring System for Grace’s worker safety
products including SuperCELL®, LTX200, and TPASS®, WorkForce®and others. The MS2000X
has several enhanced features including a simple interface to existing security and alarm
systems. The MX2000X contains an optional audible horn and strobe light, activated upon
receiving emergency alarm signals from Grace worker-safety devices.

Page 2 MS2000X-H UI 0318
The MS2000X must be mounted in an area where
there is a clear, unobstructed path to the environ-
ment where the SuperCELL®(man-down alarm) or
Transmitting TPASS®(man-down-alarm) may be
used. A typical location for the MS2000X would be
near an unobstructed office window or mounted
just outside an office.
The MS2000X should also be located
as far away as possible from other radio
equipment antennas to minimize any interfer-
ence. This includes cell phone boosters, wifi, and
other 2-way radio equipment antennas. It is also
recommended to keep the MS2000X a minimum
of six inches away from metal surfaces.
A System Check of the MS2000X can be done
by viewing the Receive LED located on the bottom
surface of the MS2000X . When a SuperCELL®
or TPASS®is turned On, Off, or by activating the
Alarm, the radio signal will cause the Red Receive
LED to flash several times - indicating signals are
successfully being received by the MS2000X .
Once the MS2000X has been prepared for AC
power, the unit may be plugged in. AC power con-
nector is a screw less Terminal rated for solid or
stranded wire from 14-22AWG. Wire should be
stripped at a 1/2”. Wires should be inserted by us-
ing a small screwdriver to depress the lever and
then inserting the wire.
When the unit is plugged in to AC Power, the
Red/Green AC Power Indicator glows (or flashes)
Green - indicating the system has AC Power and
is ready for operation. With loss of power, the Red/
Green AC Power Indicator glows (or flashes) Red
- indicating the optional Backup-Battery System
has been automatically activated, keeping the
MS2000X ON and ready for operation.
POWER INDICATOR LED
• Green Steady Glow: AC Power and battery is
fully charged.
• Optional Battery -B (see options list, pg. 5)
◦Red/Green Alternate Flashing: Battery fault
detected - open or shorted battery.
◦Red Steady Glow: Running on battery backup
◦Red Flashing: Running on Low Battery.
TRANSMIT / RECEIVE LED
• Green Flashing: when MS2000X is transmitting
a triggered message, Reset Acknowledgment,
or repeating a signal.
• Red Flashing: when MS2000X is receiving a
triggered message, Reset Acknowledgment, or
repeating a signal.
IMPORTANT:
Always test MS2000X and man-down alarms in
area of planned use prior to implementation.
Inside View of MS2000X
12 VDC
Battery
Backup
Terminal
Blocks
Connector for
Optional
Phone Dialer
Conduit
Connector
Power LED
GREEN: Running on AC Power
RED: Running on Battery
Transmit / Recieve LED
GREEN: Transmitting
RED: Receiving
2
2
22
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Page 3 MS2000X-H UI 0318
Terminal Block Labeling and Configuration
Inside View of MS2000X with -AC, -B, -LS, and -D Options Installed
State of Inputs
Upgrade Port
Configuration Port
A.
Inputs and Power
Terminal rated for solid or stranded
wire from 20-24AWG. Wire should
be stripped at a 5/16”.
Red LED Indicates
Relay is Active
C.
Relay Terminals
Terminal rated for solid or stranded
wire from 14-22AWG. Wire should
be stripped at a 3/8”.
B.
Power Terminals
Terminal rated for solid or stranded
wire from 14-22AWG. Wire should
be stripped at a 1/2”.
Additional Notes:
• Except for the battery, all parts of the MS2000X are attached to the PCB.
• Connect the AC Power cable to the Line, Neutral, and Ground positions.
• When setting case lid in place, make sure the light siren cable is NOT pinched.
To seal from intrusion of contaminants, secure the case lid by tightening all four (4) lid
bolts until snug.
• Once Installation and Field Testing is complete, the MS2000X is ready for use.
A. Inputs and Power:
1- 15VDC – In
2- +12VDC – Out
3- GND
4- GND
5- INPUT#1
6- Input Common
7- INPUT#2
8- Input Common
9- INPUT#3
10- Input Common
11- INPUT#4
12- Input Common
B. Power Terminals:
Line
Neutral
GND
C. Relay Terminals:
(4 Sets; Numbered 1 - 4)
Normally Open
Common
Normally Closed
MS2000X Factory Default Relay Setting
Relay # Trigger Hold/Activation Time*
1 User Alarm or Input #1 Active (Transmit Alarm) 20 Seconds
2 Global Evac or Input #2 Active (Transmit Global Evac) 20 Seconds
3 Input #3 Active (Transmit Canned Message) ** 3 Seconds
4 Loss of AC Detected 3 Seconds
* Hold/Activation Time: How long relay contact will be maintained after last trigger
message is received.
** Canned and Free Form Messages will only be displayed on SC500 Product Line
MS2000X Factory Default Input Setting
Input # Trigger Repeat Time
1 Transmit Alarm 6 Seconds
2 Transmit Global Evac 6 Seconds
3 Transmit Canned Message (Message#) ** 1 Hour
4 Transmit Free Form Message (“Input#4-MS2000”) ** 1 Hour
Loss of AC Transmit Free Form Message (“AC LOSS-MS2000”) ** 1 Hour
Low Battery Transmit Free Form Message (“Low Bat-MS2000”) ** 1 Hour

Page 4 MS2000X-H UI 0318
Stobe / Siren Settings
( -LS Option )
1 2 3 4 5 6 7 8
OFF
ON
Horn Dipswitch
Pattern
1 ON and 2 OFF = Non Temporal
1 OFF and 2 OFF = Temporal
1 ON and 2 ON = March Time
Tone
3 ON and 4 ON = 2400 Hz
3 ON and 4 OFF = Electromechanical
3 OFF and 4 OFF = Chime
3 OFF and 4 ON = Broadband
Volume
5 ON and 6 ON = High
5 ON and 6 OFF = Mid
5 OFF and 6 OFF = Low
7 ON and 8 ON = Horn ON
7 OFF and 8 OFF = Horn OFF

Page 5 MS2000X-H UI 0318
MS2000X
AC Powered Micro Receiver System Specifications
(With Battery Backup)
Case: Rugged fiberglass
Dimensions: 6-1/2” wide by 15” high by 6-1/2” deep
Weight: 10 lb. (with battery backup and light-siren)
Power Input Requirement:
AC Models: 110/220 VAC, 60 Hz Single Phase 1Amp
DC Models: 12-15 VDC ONLY, 0.5 Amp
Battery (Option): 12 VDC, 2.9 Amp. Hr. (provides emergency, backup power for up to 24 hours)
Frequency Range: 902-928 MHz (frequency hopping spread spectrum)
FCC ID: J5MXHEM -- Meets FCC Part 15
IC: 5916A-MXHEM -- Complies with Canadian ICES-003
For Use With: Grace Telemetry Systems using the RadioH platform (SuperCELL®, LTX200, TPASS®, WorkForce®,
and Micro Repeater).
Relay Closure: 4 form-c contact ratings 6A @ 28VDC, 6A @ 125VAC.
MS2000X BASE PACKAGE:
MS2000-H-X:
• 2-Way Micro-Transceiver System, two way signaling
• Indoor coverage of 200k Sq. Feet and 1 mile outdoor clear line of site. Indoor performance is subject to
effects of building construction and RF noise.
• 4 Opto-Isolated 12VDC inputs (See Page 3 for default configuration)
• 4 Form C Relays (See Page 3 for default configuration)
OPTION LIST:
-CA
• AC powered models shipping to Canada require Canadian Electrical Inspection.
-DC
• 12-15VDC model (0.5 Amps).
-AC
• 110/220VAC 60Hz (1 Amps).
-B (Not Available on -DC models unless suppling +15VDC).
• Includes 12VDC, 2.9AH battery backup (Up to 24 hours).
-LS
• Include Case mounted Adjustable Strobe with Light Siren (See Page 4 for LS setting).
-D (Required for ADT Telephone Dialer or MS-CA-10 Cable Assembly).
• Dialer/quick connection port (See Page 7 for -D Pin Out).
• Includes Input #1 & 2 as well as contacts for Form C Relay#1.
-HT (Not Available on DC models)
• Heated system for use in environments below 32°F / 0°C.
-SP
• Custom I/O programming as requested at time of order.
• One or more of the Inputs or Outputs will be set other than at Factory Default values found on Page #3.

Page 6 MS2000X-H UI 0318
OPTIONAL EQUIPMENT
- PM2040 Mounting Assembly - Pole Mounted with ‘C’ Brackets -
MS2000X
Side View
M
S2000X
Side Vie
w
Bolts and
Bracket Assembly
Pole
Non-Metallic
MS2000X
Top View
Flat WasherBracket
Toothed
Washer
Pole
Non-Metallic
Bolt
Bracket
Clamp
Bolts and
Bracket Assembly
Improper Installation May Degrade Performance

Page 7 MS2000X-H UI 0318
OPTIONAL EQUIPMENT
OPTIONAL PHONE DIALER
p/n: ATD
MS2000X with phone dialer has 8 pin connector
to supply relay contact trigger and power to the
external phone dialer.
Inside View of MS2000X
Shown with optional 8-Pin Connector
OPTIONAL 10 Foot Cable with Connector
p/n: MS-CA-10
CAUTION: To avoid damaging mating pins, carefully match up connector keyways
when attaching phone dialer connector.
Wiring
Pin 1 GREEN Normally Open
PIn 2 WHITE Contact Com.
Pin 3 RED +12VDC
Pin 4 Blue Input #1
Pin 5 ORANGE Normally Closed
Pin 6 White/Black Input Common
Pin 7 BLACK GND
Pin 8 Red/Black Input #2
OPTIONAL 8-Pin Connector
p/n: MS-D

© Grace Industries, Inc. Printed in U.S.A. P/N: MS2000X-H UI 0318
General Warranty Information
Grace Industries, Inc. warrants Grace Products to be free from defects in workmanship and materials for a period of one
year from the date of purchase. This warranty is valid only when the returned products are accompanied by a sales slip or
other proof of purchase that states the date and location of purchase. Grace Industries, Inc. will not repair or replace any
merchandise under warranty which has been damaged because of accident, misuse or abuse of the products while in pos-
session or control of the consumer. This warranty is void if any attempt to repair or replace parts was made or attempted
by other than qualified Grace Industry’s Inc. personnel. This warranty is void if any of the sealed compartments are opened
or tampered with. Before sending product to Grace for repair, call for Return Authorization or RA #. Please reference RA#
in shipping documents for tracking purposes. Send all repair products, prepaid and accompanied by proof of purchase to:
Grace Industries, Inc., Repair Division, 305 Bend Hill Road, Fredonia, PA 16124. Grace Industries, Inc. shall not be liable
for any direct, incidental or other consequential loss or damage arising out of the failure of the device to operate. End-user
or customer is responsible for return shipping/freight charges.
The sole and exclusive remedy under all guarantees or warranties, expressed or implied, is strictly limited to repair or
replacement as herein provided. All implied warranties, including but not limited to, warranties of fitness and merchantability,
are hereby limited in duration to a period ending one (1) year from the date of purchase. The warranty and liability set forth
in the prior paragraphs are in lieu of all other warranties, expressed or implied, in law or in fact, including implied warranties
of merchantability and fitness for a particular purpose. Some states do not allow limitations on how long an implied warranty
lasts, so the above limitations may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which may vary from state to state. Tech-
nical assistance is available by contacting Grace Industries, Inc. at 724-962-9231. Product issues may be reported at any
time to Grace Industries, Inc. at 724-962-9231.
FCC Statements
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority
to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Industry Canada Statements
This Class A digital apparatus complies with Canadian ICES-003.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two
conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interfer-
ence that may cause undesired operation of the device.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.(select the class for your device)
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’ex-
ploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur
de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le
fonctionnement.
305 Bend Hill Road
Fredonia, PA 16124 U.S.A.
724-962-9231
www.graceindustries.com
This manual suits for next models
1
Table of contents
Other Grace Industries Security System manuals