Grace Industries, Inc. 2
Operating Instructions
(90 seconds to Alarm used for example)
ACTIVATING WorkForce®: Simultaneously pressing both side buttons turns
the WorkForce® ON and activates Sensing Mode. In Sensing Mode, the
device is monitoring radio trac for alarm messages. The WorkForce® is also
sensing motion, if enabled. When Auto-ON/OFF setting is enabled, discon-
necting the unit from the charger adapter will activate WorkForce® and put into
Sensing Mode.
During activation, an operational signal of escalating audio tones will be
heard and the Power Indicator (at upper left) will begin to blink approxi-
mately once per second. A pair of Green LEDs in the Alarm Ring will begin
ashing in an alternating display to indicate motion is being sensed.
When WorkForce® is activated, its internal radio transmits signals to other
GRACE devices and equipment.
PRE-ALERT MODE: When a user remains motionless, a Pre-Alert warning
will begin to sound approximately 12 seconds before going into Alarm
Mode. When no motion is sensed for approximately 78-83 seconds, Work-
Force® begins an audible Pre-Alert sound and an alternating Yellow LED
display in the Alarm Ring. If motion is detected during Pre-Alert, WorkForce®
will reset into Sensing Mode.
ALARM MODE: There are two methods of activating Alarm Mode.
1) MOTION ALARM: After 90 to 95 seconds of no motion, WorkForce®
enters the Alarm Mode.
2) PANIC ALARM: WorkForce® user can activate Alarm Mode at any
time (from Sensing Mode or OFF Mode) by pressing the Emergency
Alarm Button.
ALARM MODE: Is indicated by a rapid pulsing of Red LEDs in the Alarm
Ring while sounding a loud audio alarm. During alarm, an emergency radio
signal is transmitted to other GRACE devices and equipment, alerting
personnel that personnel may need assistance.
RESET Alarm Mode: Return WorkForce® to Sensing Mode by simultane-
ously pressing both side buttons.
OFF: When in Sensing Mode, turn OFF by simultaneously pressing and
holding both side buttons (for approximately 3 seconds) until a series
of de-escalating audio tones are heard and all LED activity cease. When
Auto-ON/OFF setting is enabled, connecting the unit to the charger adapter
will turn the WorkForce® OFF.
WorkForce® SPECIAL FEATURES
EVACUATION ACKNOWLEDGMENT: If an Evacuate message is received
by the WorkForce®, it can be manually acknowledged by simultaneously
pressing both side buttons.
ALARM MONITORING: Allows the user to monitor the status of other per-
sonnel working in the same general area when they are equipped with
WorkForce® or other GRACE devices. WorkForce® MUST be in the Sensing
Mode to receive Alarm signals from other Grace devices or equipment.
When one device goes into Alarm and an Alarm Monitoring WorkForce®
receives the signal, the Red side LEDs will ash in an alternating pattern.
This alert can be cleared for one minute by pressing both side buttons
simultaneously. If additional GRACE devices go into Alarm during this
one-minute period, the Alarm Monitoring LED display will be reactivated.
This cycle will continue until the telemetry unit in Alarm is reset or shut o.
NOTE: If an alarm has been received, the WorkForce® will not turn o until the
alarm has been cleared or reset.
FALL DETECTION:
WorkForce® is capable of detecting a fall of greater than 4ft. If a fall is
detected, the device will enter the Fall Pre-Alert state for 15 seconds to
allow the user to reset the WorkForce® after a false trigger or a fall that
does not require assistance. Fall Pre-Alert can only be reset by simultane-
Denition of Terms
Alarm Inhibit Timer: When WorkForce® receives an alarm message from
another GRACE Industries device and that alarm is cleared, the Alarm
Inhibit Timer provides a 30 second period of time where the WorkForce®
will not receive another alarm message from that same device.
Alarm Message: When the Emergency Alarm Button is pressed, a radio
transmitted signal is sent from the WorkForce® to notify monitoring person-
nel that an emergency situation is present and rescue action is requested.
Alarm Mode: A WorkForce® is placed in Alarm Mode by pressing the
device’s Emergency Alarm Button. When this occurs, the device transmits
an emergency radio signal and emits a loud alarm audio tone.
Alarm Monitoring: Allows the user to monitor the status of other person-
nel working in the same general area when they are equipped with Work-
Force® or other GRACE devices. WorkForce® MUST be in the Sensing Mode
to receive Alarm signals from other GRACE devices or equipment.
When one device goes into Alarm and an Alarm Monitoring WorkForce®
receives the signal, the Red side LEDs will ash in an alternating pattern.
This alert can be cleared for one minute by pressing both side buttons
simultaneously. If additional GRACE devices go into Alarm during this
one-minute period, the Alarm Monitoring LED display will be reactivated.
This cycle will continue until the unit in Alarm is reset or shut o.
NOTE: If an alarm has been received, the WorkForce® will not turn o until the
alarm has been cleared or reset.
Auto ON/OFF: When this setting is enabled, WorkForce® is turned On and
O by disconnecting or connecting the device into the Charger Adapter.
Dilution of Precision: A term used in satellite-gps navigation to express
the positioning accuracy of a GPS enabled device.
EVACUATE: Evacuation signal received, indicating the user should leave
the area immediately.
Fall Detection: When in Sensing Mode, WorkForce® monitors the user for
a falling motion. Once a possible fall is detected, the unit enters Fall Pre-
Alert mode, alerting the user of a detected fall and allowing time (< 15
seconds) to clear the detected fall before an Alarm is activated.
Man-Down Alarm Mode: A WorkForce® or other GRACE safety device
enters Man-Down Alarm Mode when the Motion Sensing Timer counts
down to zero.
Monitoring Authority: The Monitoring Authority is the person/people
responsible for monitoring the status of the devices used by the various
on-scene personnel, usually from a centralized base location.
Radio Signal Propagation: Radio Signal Propagation is the behavior radio
waves exhibit when they are transmitted. Radio Signal Propagation can
be aected by structural, environmental, and atmospheric conditions.
Resetting the Device: Simultaneously pressing the side buttons resets
the WorkForce®.
Sensing Mode: When the WorkForce® is turned on, it is in Sensing Mode.
In Sensing Mode, the device is monitoring radio trac for alarm messages.
The WorkForce® is also sensing motion, if enabled.
Unit ID: The Unit ID is the unique ID number assigned to the WorkForce®
device for the purpose of radio communication. It can be viewed on the
HID WorkForce® Conguration Tool.
Unit OEM: The Unit OEM is a number assigned to the WorkForce® device
and is similar to the Unit ID. The key dierence is the Unit OEM is not a
unique number to each device. In most applications all of the WorkForce®
devices will have the same OEM number; from the factory, this number
will usually be 9090.
Read Instructions Before Use
Always test WorkForce® prior to use