Groen TDB-20 User manual

This manual provides information for:
OPERATOR & SERVICE MANUAL
IMPORTANT INFORMATION, KEEP FOR OPERATOR
PART NUMBER 141369, REV. B (02/07)
1055 Mendell Davis Drive
Jackson, MS 39272
888-994-7636, fax 888-864-7636
groen.com
.ECNEREFERERUTUFROFDENIATEREBTSUMLAUNAMSIHT
READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND
WARNINGS CONTAINED IN THIS MANUAL.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
NOTIFY CARRIER OF DAMAGE AT ONCE
It is the responsibility of the consignee to inspect the container upon receipt of
same and to determine the possibility of any damage, including concealed dam-
age. Unified Brands suggests that if you are suspicious of damage to make a
notation on the delivery receipt. It will be the responsibility of the consignee to file
a claim with the carrier. We recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
Information contained in this document is known to be current and accurate at the time
of printing/creation. Unified Brands recommends referencing our product line websites,
unifiedbrands.net, for the most updated product information and specifications.
MODELS TDB(C)CE International
STEAM JACKETED KETTLES
· Self Contained
· Stainless Steel
· Electric Heated
· Table Top Mounted
Crank Tilt Model
Pull Tilt Model

IMPORTANT — READ FIRST — IMPORTANT
THESE APPLIANCES MUST BE INSTALLED BY A COMPETENT PERSON IN CONFORMITY WITH THE
INSTALLATION AND SERVICING INSTRUCTIONS AND NATIONAL REGULATIONS IN FORCE AT THE
TIME. PARTICULAR ATTENTION MUST BE PAID TO THE FOLLOWING:
I. E. E. REGULATIONS FOR ELECTRICAL INSTALLATIONS
ELECTRICITY AT WORK REGULATIONS
HEALTH AND SAFETY AT WORK ACT
FIRE PRECAUTIONS ACT
LOCAL AND NATIONAL BUILDING REGULATIONS
USERS SHOULD BE CONVERSANT WITH APPROPRIATE PROVISIONS OF THE FIRE PRECAUTIONS
ACT. IN PARTICULAR THEY SHOULD BE AWARE OF THE NEED FOR REGULAR SERVICING BY A
COMPETENT PERSON TO ENSURE CONTINUED SAFE AND EFFICIENT APPLIANCE PERFORMANCE.
WARNING: TO PREVENT SHOCKS, APPLIANCES WHETHER GAS OR ELECTRIC, MUST BE
EARTHED.
UPON COMPLETION OF INSTALLATION, THE OWNERS MANUAL SHOULD BE HANDED TO USERS AND
THE INSTALLER SHOULD INSTRUCT RESPONSIBLE PERSON(S) IN THE CORRECT OPERATION AND
MAINTENANCE OF THE APPLIANCE.
THIS EQUIPMENT IS ONLY FOR PROFESSIONAL USE, AND SHALL BE OPERATED BY QUALIFIED
PERSONS. IT IS THE RESPONSIBILITY OF THE SUPERVISOR OR EQUIVALENT TO ENSURE THAT
USERS WEAR PROTECTIVE CLOTHING, AND TO DRAW ATTENTION TO THE FACT THAT, SOME PARTS
WILL, BY NECESSITY, BECOME VERY HOT AND WILL CAUSE BURNS IF TOUCHED ACCIDENTALLY.
UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER ARE
NOT TO BE ADJUSTED BY THE INSTALLER.
BEFORE ATTEMPTING ANY SERVICING, ENSURE THAT THE ELECTRICAL SUPPLY IS DISCONNECTED.
WARNING: THE UNIT MUST BE INSTALLED BY PERSONNEL QUALIFIED TO WORK WITH
ELECTRICITY. IMPROPER INSTALLATION CAN RESULT IN INJURY TO PERSONNEL
AND/OR DAMAGE TO EQUIPMENT. THE UNIT MUST BE INSTALLED IN ACCORDANCE
WITH APPLICABLE CODES.
CAUTION: SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.
WARNING: TO AVOID DAMAGE OR INJURY, FOLLOW THE WIRING DIAGRAM EXACTLY WHEN
CONNECTING A UNIT.
WARNING: BEFORE CLEANING THE OUTSIDE OF THE KETTLE, DISCONNECT ELECTRIC POWER .
KEEP WATER AND SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS.
NOTICE: DO NOT USE ANY DE-GREASER THAT CONTAINS POTASSIUM HYDROXIDE OR SODIUM
HYDROXIDE OR THAT IS ALKALINE.
WARNING: USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR
THEIR AUTHORIZED DISTRIBUTOR VOIDS ALL WARRANTIES AND CAN RESULT IN
BODILY INJURY TO THE OPERATOR AND DAMAGE THE EQUIPMENT. SERVICE BY
OTHER THAN FACTORY-AUTHORIZED PERSONNEL WILL VOID ALL WARRANTIES.
WARNING: HIGH VOLTAGE EXISTS INSIDE CONTROL COMPARTMENTS. DISCONNECT FROM
BRANCH BEFORE SERVICING. FAILURE TO DO SO CAN RESULT IN SERIOUS INJURY
OR DEATH.
CAUTION: BE SURE ALL OPERATORS READ, UNDERSTAND AND FOLLOW THE OPERATING
INSTRUCTIONS, CAUTIONS, AND SAFETY INSTRUCTIONS CONTAINED IN THIS MANUAL.
WARNING: THIS UNIT IS INTENDED FOR USE IN THE COMMERCIAL HEATING, COOKING AND
HOLDING OF WATER AND FOOD PRODUCTS, PER THE INSTRUCTIONS CONTAINED IN
THIS MANUAL. ANY OTHER USE COULD RESULT IN SERIOUS PERSONAL INJURY OR
2

3
DAMAGE TO THE EQUIPMENT AND WILL VOID WARRANTY.
WARNING: AVOID ALL DIRECT CONTACT WITH HOT EQUIPMENT SURFACES. DIRECT SKIN
CONTACT COULD RESULT IN SEVERE BURNS.
WARNING: AVOID ALL DIRECT CONTACT WITH HOT FOOD OR WATER IN THE KETTLE. DIRECT
CONTACT COULD RESULT IN SEVERE BURNS.
CAUTION: DO NOT OVER FILL THE KETTLE WHEN COOKING, HOLDING OR CLEANING. KEEP
LIQUIDS A MINIMUM OF 2-3” (5-8 cm) BELOW THE KETTLE BODY RIM TO ALLOW
CLEARANCE FOR STIRRING, BOILING AND SAFE PRODUCT TRANSFER.
WARNING: TAKE SPECIAL CARE TO AVOID CONTACT WITH HOT KETTLE BODY OR HOT PRODUCT
WHEN ADDING INGREDIENTS, STIRRING OR TRANSFERRING PRODUCT TO ANOTHER
CONTAINER.
WARNING: WHEN TILTING KETTLE FOR PRODUCT TRANSFER:
1) WEAR PROTECTIVE OVEN MITT AND PROTECTIVE APRON.
2) USE CONTAINER DEEP ENOUGH TO CONTAIN AND MINIMIZE PRODUCT
SPLASHING.
3) PLACE CONTAINER ON STABLE, FLAT SURFACE, AS CLOSE TO KETTLE AS
POSSIBLE.
4) STAND TO LEFT OR RIGHT SIDE OF KETTLE WHILE POURING. DO NOT STAND
DIRECTLY IN POUR PATH OF HOT CONTENTS.
5) POUR SLOWLY, MAINTAIN CONTROL OF KETTLE, AND RETURN KETTLE BODY TO
UPRIGHT POSITION AFTER CONTAINER IS FILLED OR TRANSFER IS COMPLETE.
6) DO NOT OVER-FILL CONTAINER. AVOID DIRECT SKIN CONTACT WITH HOT
CONTAINER AND ITS CONTENTS.
CAUTION: KEEP FLOORS IN FRONT OF KETTLE WORK AREA CLEAN AND DRY. IF SPILLS OCCUR,
CLEAN IMMEDIATELY, TO AVOID SLIPS OR FALLS.
WARNING: FAILURE TO CHECK SAFETY VALVE OPERATION PERIODICALLY COULD RESULT IN
PERSONAL INJURY AND/OR DAMAGE TO EQUIPMENT.
WARNING: WHEN TESTING, AVOID ANY EXPOSURE TO THE STEAM BLOWING OUT OF THE
SAFETY VALVE. DIRECT CONTACT COULD RESULT IN SEVERE BURNS.
WARNING: BEFORE REPLACING ANY PARTS, DISCONNECT THE UNIT FROM THE ELECTRIC
POWER SUPPLY.
WARNING: KEEP WATER AND SOLUTIONS OUT OF CONTROLS AND ELECTRICAL EQUIPMENT.
NEVER SPRAY OR HOSE THE SUPPORT HOUSING OR ELECTRICAL CONNECTIONS.

4
Table of Contents
IMPORTANTOPERATORWARNINGS ...................................................... 2
EQUIPMENT DESCRIPTION .............................................................. 5
INSPECTION & UNPACKING .............................................................. 7
INSTALLATION......................................................................... 8
INITIAL START-UP ...................................................................... 9
OPERATION.......................................................................... 10
SEQUENCE OF OPERATION ............................................................ 12
MAINTENANCE ....................................................................... 13
TROUBLESHOOTING .................................................................. 15
CLEANING ........................................................................... 19
PARTSLISTS ......................................................................... 21
SCHEMATICS......................................................................... 25
SERVICELOG ........................................................................ 26
REFERENCES ........................................................................ 26
WARRANTY .......................................................................... 27

5
Equipment Description
The Groen TDB(C) is a table top, tilting, steam
jacketed kettle with a thermostatically controlled,
self-contained, electrically-heated steam supply and
appropriate controls, mounted on a sturdy base. The
Model TDB(C) is available in 20 or 40 - quart
capacity.
The body of the TDB/7 Kettle is constructed of
stainless steel, welded into one solid piece. The
kettle is furnished with a reinforced rim and a
butterfly shaped pouring lip. It has a steam jacket
rated for pressures up to 50 PSIG. Kettle finish is
180 emery grit on the inside and bright semi-deluxe
on the outside. A tilt handle allows the operator to
manually tilt the kettle body in a controlled manner.
A crank tilt model is also available. Pouring height
accepts pans up to 4 inches high on a table top.
A built-in steam generator, sized for the kettle
capacity and heated by electricity, delivers steam
into the jacket. “Airless” operation of the steam
jacket permits uniform, efficient heating at
temperatures as low as 150°F and as high as 295°F.
In addition to the adjustable thermostat for operating
control, the unit has a tilt cut-off switch, low water
cut-off, safety valve, and high-limit pressure switch
as safety features. A heating indicator light,
pressure gauge, and sight glass are provided for
monitoring kettle operation.
A single electrical connection is required for
installation. The unit may be ordered for use with
230 Volt single phase or 400 Volt three phase
power.
KETTLE CHARACTERISTICS
TDB(C)-20 TDB(C)-40
Kettle Capacity 20 qts. 18.8 liters 40 qts. 37.6 liters
Jacket Capacity 4 qts. 3.7 liters 5 qts. 4.7 liters
Diameter 14” 36 cm 16-1/2” 42 cm
Depth 11” 28 cm 14-1/4” 36 cm
Base Width 24” 60 cm 28” 60 cm
Base Depth 16” 41 cm 16” 41 cm
KW at 230 Volt Single Phase 7.8 13.3
KW at 400 Volt Three Phase 7.8 13.3
Rated Amp Load - 1?33 57
Rated Amp Load - 3?11 (L1, L2, L3) 19 (L1, L2, L3)

6
Pull Tilt TDB/7, CE Model
Crank Tilt TDB/7, CE Model
Models
Optional equipment available with any model:
1. Stand that supports the unit and holds a pan in position for filling
2. Lift-off cover
3. Basket insert
4. Fill faucet
5. Manual stirrers (factory installed)
6. Motor driven agitator (factory installed)

7
The TDB/7 is shipped from the factory strapped on a
pallet. If the unit is a pull tilt model, the handle is packed
inside the kettle for shipment.
Inspection & Unpacking
The unit will arrive in a heavy shipping carton and
will be attached to a skid. Immediately upon receipt,
inspect the carton carefully for exterior damage.
CAUTION
SHIPPING STRAPS ARE UNDER TENSION
AND CAN SNAP BACK WHEN CUT. TAKE
CARE TO AVOID PERSONAL INJURY OR
DAMAGE TO THE UNIT BY STAPLES
LEFT IN THE WALLS OF THE CARTON.
Carefully cut the polyester straps around the carton
and detach the sides of the box from the skid. Pull
the carton up off the unit.
Thoroughly inspect the unit for concealed damage.
Report any shipping damage or incorrect shipments
to the delivery agent.
Write down the model number, serial number, and
installation date, and retain this information
for future reference. Space for these entries is
provided at the top of the Service Log at the back of
this manual. Keep this manual on file and
available for operators to use.
CAUTION
THIS UNIT WEIGHS 140 TO 163 LB. (64 TO
74 KG). INSTALLER SHOULD OBTAIN
HELP AS NEEDED TO LIFT THIS WEIGHT
SAFELY.
When installation is to begin, carefully cut the straps
which hold the unit on the skid. Lift the unit straight
up off the skid. Examine packing materials to be
sure loose parts are not discarded with the
materials.
Attach the tilt handle (normally shipped inside the
kettle) by carefully threading it into the socket on the
trunnion support. Be careful to avoid cross-threading
fine socket threads. This step is unnecessary if the
kettle is a crank tilt model.

8
Installation
The Groen Kettle is provided with
complete internal wiring. It is ready for
immediate connection. A wiring diagram
is provided in this manual and on the
inside of the control housing service
panel. Any mechanical or electrical changes must
be approved by Groen’s Food Service Engineering
Department.
WARNING
INSTALLATION OF THE KETTLE MUST
BE DONE BY PERSONNEL QUALIFIED TO
WORK WITH ELECTRICITY. IMPROPER
INSTALLATION CAN RESULT IN INJURY
TO PERSONNEL AND/OR DAMAGE TO
EQUIPMENT.
The completed unit has been operated at the factory
to test all controls and heater elements.
1. Set the kettle in place and level it. The base
should be securely fastened to a table or work
surface. Four 3/8”-16 N.C. threaded couplings
are provided in the base of unit. Installation
under a ventilation hood is recommended.
2. Provide electrical power as specified on the
electrical information plate attached to the
equipment. Observe all local and national
codes, and all regulations in force at the time
of installation.
3. The equipment is shipped ready for three
phase operation. Refer to the wiring diagram
for single phase operation.
4. Bring the electrical service through the
entrance at the rear of the support housing,
making a watertight connection with the
incoming lines. (A BX connection is not
recommended.) Observe all local and
national codes, and all regulations in force at
the time of installation.
DANGER
ELECTRICALLY GROUND THE UNIT AT
THE TERMINAL PROVIDED. FAILURE TO
GROUND UNIT COULD RESULT IN
ELECTROCUTION AND DEATH.
5. Confirm that the jacket water level is above
mid point of sight glass. If the level is low,
follow the instructions under “Jacket Filling
and Water Treatment,” Page 14.
6. Electrically earth the unit at the terminal
provided.
7. Equipotential terminal: In accordance with
national regulations, the unit has been fitted
with an equipotential terminal.
TDB(C) ELECTRICAL SPECIFICATIONS
20 QUARTS 40 QUARTS
VOLTAGE PHASE KW AMPS KW AMPS
230 1 7.8 33 13.3` 57
400 3 7.8 11.2 13.3 19
ELECTRICAL SUPPLY CONNECTION
REQUIREMENTS
Unit TDB(C)-20 TDB(C)-40
230V - 1 Phase 33 Amps 57 Amps
400V - 3 Phase 33 Amps 57 Amps

9
A simple turn of the thermostat controls the Groen
TDB and TDBC kettle.
Initial Start-Up
IMPORTANT:
BE SURE ALL OPERATORS READ, UNDERSTAND AND FOLLOW THE OPERATING
INSTRUCTIONS, CAUTIONS, AND SAFETY INSTRUCTIONS CONTAINED IN THIS MANUAL.
Now that the kettle has been installed, you should
test it to ensure that the unit is operating correctly.
1. Remove all literature and packing materials
from inside and outside of the unit.
2. Confirm that the kettle tilts properly. Either
turn the crank or use the handle to tilt the
kettle and return it to the upright position.
2. Turn on the electrical service to the unit.
3. Pour two to four liters of water into the
kettle.
4. Following “To Start Kettle” instructions in the
“Operation” section of this manual, begin
heating the water at the highest thermostat
setting. The heating indicator light should
come on immediately, and heating should
continue until the water boils.
WARNING
AVOID ALL DIRECT CONTACT WITH HOT
SURFACES. DIRECT SKIN CONTACT
COULD RESULT IN SEVERE BURNS.
AVOID ALL DIRECT CONTACT WITH HOT
FOOD OR WATER IN THE KETTLE.
DIRECT CONTACT COULD RESULT IN
SEVERE BURNS.
5. To shut down the unit, turn the thermostat dial to
“OFF”.
If the unit functions as described above, it is ready
for use. If the unit does not function as intended,
contact your local Groen Certified Service Agency.

10
On most TDB/7 units the jacket water level is shown
in a sight glass, right on the kettle.
Operation
CE units have three lights on the Control Panel. The
“POWER” light comes on when the the unit is turned
on. It indicates that power is being supplied to the unit.
The “HEAT” light comes on when heating elements are
heating the kettle. The “LOW WATER” light will come
on when the water level in the jacket falls below
acceptable operating levels. Refer to “Jacket Filling
and Water Treatment” on Page 14.
A. To Start Kettle
1. EVERY DAY make sure that the jacket water
level is above the mid-point of the round
sight glass. If the level is low, service is
necessary.
2. Check the pressure gauge. If the gauge does
not show 20 to 30 inches of vacuum (i.e., a
reading of 20 to 30 below 0), see “Jacket
Vacuum” on page 14.
3. Turn on the electrical power to the unit.
4. Turn the thermostat dial to the desired
setting. The heating indicator light indicates
that the kettle is heating, and cycling of the
light on and off indicates that the kettle is
being held at the set temperature. Once in
each cycle the contactors in the support
housing will make a clicking sound. This is
normal.
B. To Transfer Product or Empty Kettle
The kettle is designed and manufactured to be
tilted in a controlled manner. On those units
equipped with a tilt handle, grasp the insulated
plastic ball firmly. Maintain a firm grip on handle
when tilting, while keeping kettle body in a tilted
position and when SLOWLY returning the kettle
body to an upright position. On those equipped
with crank tilt, turn the handle. The kettle will
remain in the position to which tilted until cranked
again.
WARNING
AVOID ALL DIRECT CONTACT WITH HOT
SURFACES. DIRECT SKIN CONTACT COULD
RESULT IN SEVERE BURNS.
On most TDB(C) units the jacket water level is shown
in a sight glass, right on the kettle.

11
Lift the rear edge of the cover first.
AVOID ALL DIRECT CONTACT WITH HOT FOOD
OR WATER IN THE KETTLE. DIRECT CONTACT
COULD RESULT IN SEVERE BURNS.
TAKE SPECIAL CARE TO AVOID CONTACT WITH
HOT KETTLE BODY OR HOT PRODUCT, WHEN
AD D IN G I N G R E D IE N T S, ST IR R IN G O R
TRANSFERRING PRODUCT TO ANOTHER
CONTAINER.
CAUTION
DO NOT OVERFILL THE KETTLE WHEN
COOKING, HOLDING OR CLEANING. KEEP
LIQUIDS AT LEAST 2-3” (5-8 cm) BELOW THE
KETTLE BODY RIM TO ALLOW CLEARANCE
FOR STIRRING, BOILING PRODUCT AND SAFE
TRANSFER.
WARNING
WHEN TILTING KETTLE FOR PRO DUCT
TRANSFER:
1) WEAR PROTECTIVE OVEN MITT AND
PROTECTIVE APRON.
2) USE DEEP CONTAINER TO CONTAIN AND
MINIMIZE PRODUCT SPLASHING.
3) PLACE CONTAINER ON STABLE, FLAT
SURFACE, AS CLOSE TO KETTLE AS
POSSIBLE.
4)
5) POUR SLOWLY. MAINTAIN CONTROL OF
KETTLE BODY HANDLE AT ALL TIMES, AND
RETURN KETTLE BODY TO UPRIGHT POSITION
AFTER CONTAINER IS FILLED OR TRANSFER
IS COMPLETE.
6) DO NOT OVERFILL CONTAINER. AVOID
DIRECT SKIN CONTACT WITH HOT CONTAINER
AND ITS CONTENTS.
CAUTION
KEEP FLOORS IN FRONT OF THE KETTLE
WORK AREA CLEAN AND DRY. IF SPILLS
OCCUR, CLEAN AT ONCE TO AVOID SLIPS OR
FALLS.
Common Accessories
1. Lift Off Cover
As with stock pot cooking, an optional lift off cover
can speed up the heating of water and food products.
A cover helps retain heat in the cooking vessel and
reduces the amount of heat and humidity released
into the kitchen. Use of a cover can reduce some
product cook times and help maintain the
temperature, color and texture of products being
held or simmered for extended periods.
Make sure the handle is secure on the lift off
cover before using. ALWAYS use the handle to
place or remove cover from the kettle. Wear
protective oven mitts and a protective apron.
When putting the cover on the kettle, position it
on top of kettle rim, with its flat edge facing the
pouring lip.
WARNING
AVOID ALL DIRECT CONTACT WITH HOT
SURFACES. DIRECT SKIN CONTACT COULD
RESULT IN SEVERE BURNS.
AVOID ALL DIRECT CONTACT WITH HOT
FOOD OR WATER IN THE KETTLE. DIRECT
CONTACT COULD RESULT IN SEVERE
BURNS.
When removing cover:
a) Firmly grasp the handle.
STAND TO LEFT OR RIGHT OF KETTLE
(DEPENDING ON HANDLE PLACEMENT) WHILE
POURING - NOT DIRECTLY IN POUR PATH OF
HOT CONTENTS.

12
b) Lift rear edge (farthest from operator) 1-2” (3-5
cm) to allow any steam and water vapor to
escape the cooking vessel. Wait 2-3 seconds.
c) Tilt cover to 45-60° angle and allow any hot
condensate or product to roll off cover back into
kettle.
d) Remove cover, ensuring that any remaining hot
condensate or product does not drip on
operator, floor or work surfaces.
e) Place cover on safe, flat, sanitary, out-of-the-
way surface, or return to kettle rim.
CAUTION
DO NOT TILT KETTLE BODY WITH COVER IN
PLACE. COVER MAY SLIDE OFF, CAUSING
INJURY TO OPERATOR.
2. Basket Insert
An optional kettle basket insert can assist in
cooking water-boiled products including eggs,
potatoes, vegetables, shell fish, pasta and rice. The
nylon mesh liner must be used when cooking
product smaller than the mesh size of the basket,
which is approximately 1/4” (6 mm). This includes
rice and small pasta shapes.
Tips For Use.
a) Allow for the water displacement of the basket
and product to be cooked. This may mean only
filling the kettle half full of water. Test the basket
and product displacement with the kettle OFF,
and with cold water in the kettle.
CAUTION
DO NOT OVERFILL THE KETTLE WHEN
COOKING, HOLDING OR CLEANING. KEEP
LIQUIDS A MINIMUM OF 2-3” (5-8 cm) BELOW
THE KETTLE BODY RIM TO ALLOW
CLEARANCE FOR STIRRING, BOILING AND
SAFE PRODUCT TRANSFER.
WARNING
AVOID ALL DIRECT CONTACT WITH HOT
SURFACES. DIRECT SKIN CONTACT COULD
RESULT IN SEVERE BURNS.
AVOID ALL DIRECT CONTACT WITH HOT FOOD
OR WATER IN THE KETTLE. DIRECT CONTACT
COULD RESULT IN SEVERE BURNS.
b) Load basket on a level, stable work surface.
c) Lift the loaded basket with both hands. Get
help from another person if the basket is too
heavy for safe handling.
d) Slowly lower product into kettle.
e) When removing basket with cooked product,
lift basket straight up, ensuring bottom of
basket clears the rim and pouring lip of the
kettle. Wear protective oven mitts and
protective apron.
f) Allow hot water to fully drain from product,
before moving basket away from the kettle.
Do not rest kettle basket on kettle rim or
pouring lip. If basket is too heavy for
individual to lift and safely move, get help
from another person. Remove product
immediately from basket into another
container, being sure to avoid contact with
hot product and hot basket or. . .
g) Place basket with food on stable, flat
surface, setting it inside a solid steamer or
bake pan, to catch any remaining hot water
draining from product.
Sequence of Operation
The following “action-reaction” outline is provided to
help the user understand how the equipment works.
When the operator starts up the kettle by turning the
operating thermostat dial from “OFF” to a desired
setting, the thermostat switch closes. This lights up
the heating indicator light and causes the contactors
to close, allowing power to flow to heating elements.
When the temperature of the steam jacket reaches
the value corresponding to the dial setting, the
thermostat switch opens. This turns off the heating
indicator light and causes the contactors to open,
stopping the power to the heaters. As soon as the
thermostat senses that the kettle is cooling below
the set point, the thermostat switch closes, the
heating indicator light comes on, the contactors
close, and the heaters come on again. On-off
cycling continues, keeping the kettle at the set
temperature This is why the heating indicator light
cycles on and off during normal operation. Every
time the kettle is tilted, the tilt cut-off switch
interrupts the power supply to the heaters, so that
the heating elements will not operate while not
submerged in the jacket water.

13
Test the safety valve at least twice each month.
The pressure gauge should show a vacuum of 20
to 30 inches when the kettle is cold.
If steam pressure greater than 50 PSI is generated in
the jacket, the safety valve will open and relieve the
excess pressure.
If the jacket water level gets too low and the heating
elements overheat, the high-limit control will open,
shutting off power to the elements until the kettle cools.
Setting the operating thermostat dial to “OFF” shuts
down all control and heating circuits.
Maintenance
NOTICE: Contact Groen or an authorized Groen representative when repairs are required.
1. Periodic Maintenance
A Maintenance & Service Log is provided at the
back of this manual. Each time maintenance is
performed on your Groen kettle, enter the date of
the work, what was done, and who did it. Keep this
manual on file and available for operators to use.
Periodic inspection will minimize equipment down
time and increase the efficiency of operation. The
following points should be checked:
[BY OPERATOR]
a. Check the pressure/vacuum gauge every day.
The gauge should show a vacuum of 20 to 30
inches, when the kettle is cold. If it does not,
see “Jacket Vacuum” on page 14.
b. Also check the jacket water level each day. It
should be above mid point of the round sight
glass. If the level is low, see “Jacket Filling and
Water Treatment” on page 14.
[BY SERVICE TECHNICIAN]
c. Test the safety valve at least twice each
month. Test the valve with the kettle
operating at 15 psi (105 kPa), by pulling up
the test chain for at least five seconds. Then
release the chain and let the valve snap
shut. If the valve does not activate, (there is
no evidence of discharge, or the valve
leaks) stop using the kettle immediately and
contact a qualified Groen service
representative.
d. The inside of the support housing should be
kept clean.
e. At least twice a year, grease the two
trunnion bearings. The bearings are located
within the kettle support housing. Remove
the access panels from the support housing
with a screwdriver to gain access to the
grease fittings. Use a lithium-based, multi-

14
purpose grease. When the access panels are
removed, the mounting bolts for the trunnion
bearings and tilt switch can also be checked for
tightness.
WARNING
WHEN TESTING, AVOID ANY EXPOSURE TO
THE STEAM BLOWING OUT OF THE SAFETY
VALVE. DIRECT CONTACT COULD RESULT
IN SEVERE BURNS.
DISCONNECT ELECTRICAL POWER FROM
THE KETTLE BEFORE ATTEMPTING TO
GREASE THE TRUNNION BEARINGS.
f. On the crank-tilt models, the gear housing has
fittings for proper lubrication of moving parts.
Because the gears do not run in oil, periodic
lubrication with grease is necessary. Frequency of
lubrication will depend on operating conditions, but
the service should be performed at least once
every six months.
Add grease through the Zerk fittings on the
gear housing until you see grease flow out of
the bearings around the trunnion shaft. Also
place a liberal amount of grease on the gear to
cover the arc that is in contact with the worm
gear. When finished, reassemble access
panels to support housing.
Electrical wiring should be kept securely
connected and in good condition.
2. Jacket Vacuum
When the kettle is cold, a positive pressure reading
or a reading around zero on the pressure/vacuum
gauge indicates the presence of air in the jacket.
Air in the jacket slows down the heating of the
kettle.
To remove air:
a. Start the unit. (See the “Operation” section of
this manual.) (Be sure there is water or product
in the kettle when heating).
b. When the pressure/vacuum gauge reaches a
positive pressure reading of five PSI, release
the trapped air and steam by pulling up on the
safety valve for about 1 second. Repeat this
step, then let the chain snap back into the
closed position.
3. Jacket Filling and Water Treatment
The jacket was charged at the factory with the
proper amount of treated distilled water. You
may need to restore the water to its proper level,
either because water was lost as steam during
venting or because treated water was lost by
draining.
IMPORTANT
Pressure gauge must read 0 PSI or less before
you fill jacket with water.
To fill jacket with water:
a. If you are replacing water lost as steam, use
distilled water. If you are replacing treated
water that ran out of the jacket, prepare
more treated water as directed in step 3,
“Water Treatment Procedure”.
b. Remove fill plug with open-end wrench or
crescent wrench.
c Open shutoff valve (turn handle 90° on ball
valve).
d. Use a funnel and add water to jacket.
e Check water level in jacket, by viewing
water level indicator glass.
f. Continue to add water until the water level
indicator glass is 3/4 full.
g Close shutoff valve, and install fill plug.
Follow procedure in “Jacket Vacuum” to
remove air from kettle jacket.
3. Water Treatment Procedure
WARNING
TO AVOID INJURY, READ AND FOLLOW ALL
PRECAUTIONS STATED ON THE LABEL OF
THE WATER TREATMENT COMPOUND.
a. Obtain water treatment compound and a PH
test kit from your authorized Groen parts
distributor.
b. Fill the mixing container with the measured
amount of water required. (See the table at
right). Use distilled water.
.

15
c. Hang a strip of pH test paper on the rim of the
container, with about 25 mm of the strip below
the surface of the water.
d. Measure the water treatment compound you
will be using. (One way to do this is to add the
compound from a measuring cup.)
e. Stir the water continuously, while you slowly
add water treatment compound, until the water
reaches a pH between 10.5 and 11.5. Judge
the pH by frequently comparing the color of the
test strip with the color chart provided in the pH
test kit.
f. Record the exact amounts of water and
treatment compound used. These amounts
may be used again, if the same sources of
water and compound are employed to refill the
jacket in the future. However, it is advisable to
check the pH every time treated water is
prepared. For optimum performance, use
correctly treated, distilled water.
Model Jacket Capacity
TDB(C)-20 3.8 Liters
TDB(C)-40 4.7 Liters
4. Component Replacement
WARNING
BEFORE REPLACING ANY PARTS,
DISCONNECT THE UNIT FROM THE ELECTRIC
POWER SUPPLY.
Wiring is marked as shown on the schematic
drawings. Be sure new components are wired in the
same manner as the old.
Troubleshooting
Your kettle is designed to operate smoothly and efficiently if properly maintained. However, the following is a list of
checks in the event of a problem. Wiring diagrams are furnished inside the service panel and at the back of this
manual. Items followed by X, should only be done by a qualified service representative. USE OF ANY
REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR ITS AUTHORIZED
DISTRIBUTORS CAN INJURE TO THE OPERATOR AND DAMAGE THE EQUIPMENT AND WILL VOID ALL
WARRANTIES.
SYMPTOM WHO WHAT TO CHECK
X indicates items which must be performed by an authorized technician.
Kettle will not heat, and heating
indicator will not come on.
User a. Electric power supply to the unit.
b. Water level in jacket.
Auth Service
Rep Only
c. Control circuit fuses. Replace a blown fuse only with a fuse of
the same AMP rating. X
d. For loose or broken wires. X
e. Tilt cut-off switch. X
f. That pressure switch is open. X
g. Operation of variable thermostat. X
h. Low water cutoff. X
Kettle will not heat, but heating
indicator comes on.
Auth Service
Rep Only
a. Contactor. X
b. Heater elements with ohmmeter for ground short or open
element. If element is defective, call Groen. X

16
SYMPTOM WHO WHAT TO CHECK
X indicates items which must be performed by an authorized technician.
Kettle continues heating after it
reaches the desired temperature
User a. Thermostat dial setting.
Auth Service
Rep Only
b. Thermostat circuit for short. X
c. Thermostat operation. The thermostat should click when the
dial is rotated above and below the setting for the temperature
of the kettle. X
d. Contactor, to determine whether it is energized or stuck.
Kettle stops heating before it
reaches the desired temperature.
User a. Thermostat dial setting.
Auth Service
Rep Only
b. Thermostat calibration. X
c. Thermostat operation. The thermostat should click when the
dial is rotated above and below the setting for the temperature
of the kettle. X
Kettle heats slowly User a. For air in the jacket. See “Jacket Vacuum” in the
“Maintenance” section of this manual.
Auth Service
Rep Only
b. Heater elements with ohmmeter for ground short or open
element. If an element is defective, call Groen. X
c. Voltage of main power source. X
Safety valve pops. User a. For air in the jacket. See “Jacket Vacuum” in the
“Maintenance” section of this manual.
Auth Service
Rep
Only
b. Pressure switch setting. X
c. Thermostat operation. Thermostat should click
when the dial is rotated above and below the
setting for the temperature of the kettle. X
d. Safety valve. If the valve pops at pressures
below 49 PSI, replace it. X
e. Contactor, to determine whether it is de-
energized. X
User Instructions
Regulations and Safety Precautions
These Appliances have been CE marked on the basis of compliance with the EMC and Low Voltage Directive.
These appliances MUST BE installed by a competent person in conformity with the INSTALLATION AND
SERVICING INSTRUCTIONS and National Regulations in force at the time.
Particular attention MUST be paid to the following:
I.E.E. Regulations for Electrical Installations
Electricity at Work Regulations
Health and Safety at Work Act
Fire Precautions Act
Local and National Building Regulations
Those parts which have been protected by the manufacturer MUST NOT be adjusted by the User.
Users should be conversant with the appropriate provisions of the Fire Precautions Act. In particular the need for
regular servicing by a competent person to ensure the continued safe and efficient performance of the Appliance.
WARNING
TO PREVENT SHOCKS, ALL APPLIANCES WHETHER GAS OR ELECTRIC, MUST BE
EARTHED.

17
Upon completion of the installation, the Owners Manual should be handed to the users and the installer should
instruct the responsible person(s) on the correct operation and maintenance of the Appliance. This equipment is
ONLY FOR PROFESSIONAL USE, and shall be operated by QUALIFIED persons. It is the responsibility of the
Supervisor or equivalent to ensure that users wear SUITABLE PROTECTIVE CLOTHING and to draw attention to
the fact that, some parts will, by necessity, become VERY HOT and will cause burns if touched accidentally.
IMPORTANT - READ FIRST - IMPORTANT The Groen Steam Jacketed Kettle you have just purchased has been
handcrafted from the finest materials, meticulously inspected, and carefully tested to ensure that you receive the
best possible product. With reasonable care and periodic maintenance, it will provide years of faithful service. It is
recommended that you establish a timetable for periodic maintenance as outlined in this manual. Space is
provided in the Service Log at the back of this manual.
Equipment Description
General
Groen models TDB(C) are stainless steel, steam
jacketed, table mounted, tilting kettles with a self-
contained, electric-heated steam source. The kettle
body is welded into one piece and furnished with a
reinforced bar rim and welded "butterfly" pouring lip.
The interior of the kettle is polished to a 180 emery grit
finish, and the exterior is given a bright semi-deluxe
finish. The unit is ASME shop inspected and registered
with the National Board for working pressures up to 50
PSI. Kettle support, tilting mechanism, and controls are
contained in an enclosed base. Tilting is provided by a
self-locking, worm-and-gear device, or by a tilt handle.
Charged at the factory with treated, distilled water, the
steam source provides kettle temperature of 65?C to
150?C. Controls for the unit include a thermostat,
pressure gauge, gauge glass, safety valve, pressure
limit control, low water cut-off and an on/off switch.
Service connections are required for 230 Volt, single
phase, 50 Hz and 400 Volt, three phase, 50 Hz
electricity.
IMPORTANT: Prior to operation, clean out the
kettle pan thoroughly using hot water and
detergent. Rinse out and dry thoroughly.

18
Operational and Maintenance Safety
WARNING
INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL QUALIFIED TO WORK WITH
ELECTRICITY AND PLUMBING IN ACCORDANCE WITH ALL APPLICABLE CODES.
BEFORE REPLACING ANY PARTS, DISCONNECT THE UNIT FROM THE ELECTRIC POWER SUPPLY.
TO PREVENT SHOCKS, ALL APPLIANCES WHETHER GAS OR ELECTRIC, MUST BE EARTHED.
CAUTION
BE SURE ALL OPERATORS READ, UNDERSTAND, AND FOLLOW THE OPERATING INSTRUCTIONS,
CAUTIONS AND SAFETY INSTRUCTIONS CONTAINED IN THIS MANUAL.
Operation
1. Initial Operational Readiness Check
After the TDB(C) Kettle has been installed according
to service and installation instructions, perform initial
start-up as a test, to ensure that the unit is operating
correctly.
a. Remove all literature and packing material from
the interior and exterior of the unit.
b. Make sure electricity supply is switched on.
c. Ensure that the kettle is filled with water.
d. Check the water level in the jacket. The level
should be between the lines on the gauge glass. If
the level is low, the jacket water level will be
required to be topped up. (This will require a
service call).
e. Check the pressure gauge. If the gauge does not
show sufficient vacuum (20 to 30 below zero)
then the jacket will require venting. (This will
require a service call).
f. Switch the On/Off switch to the "On" position. The
"power on" neon will illuminate.
g. Turn the thermostat dial to the required setting.
The "heat" neon will illuminate.
WARNING
AVOID CONTACT WITH THE FLUE.
SURFACES ARE VERY HOT AND WILL CAUSE
BURNS. DO NOT OBSTRUCT FLUE OPENING.
2. To Shut Down Kettle
a. Turn the thermostat dial to the "Off'' position.
b. Switch the On/Off switch to the "Off" position.
c. For a prolonged shut down, turn the electricity
main off.
Follow steps a and b.
3. Filling the Kettle
Prior to operation, thoroughly clean the kettle using
hot water and detergent.
Kettle capacities:
Model Maximum Capacity
TDB(C)-20 18.8 Litres
TDB(C)-40 37.6 Litres
To prevent surge boiling, no more than 80% of
the maximum capacity should be used.
4. Users Thermostat
Provides automatic control of the Kettle Jacket
temperature at settings up to 147°Cmaximum.
5. Sequence of Operation
The following “action-reaction” outline is provided to
help the user understand how the equipment works.
When the operator starts up the kettle by turning the
operating thermostat dial from “OFF” to a desired
setting, the thermostat switch closes. This lights up
the heating indicator light and causes the contactors
to close, allowing power to flow to heating elements.
When the temperature of the steam jacket reaches

19
the value corresponding to the dial setting, the
thermostat switch opens. This turns off the heating
indicator light and causes the contactors to open,
stopping the power to the heaters.
As soon as the thermostat senses that the kettle is
cooling below the set point, the thermostat switch
closes, the heating indicator light comes on, the
contactors close, and the heaters come on again.
On-off cycling continues, keeping the kettle at the set
temperature. This is why the heating indicator light
cycles on and off during normal operation. Every
time the kettle is tilted, the tilt cut-off switch interrupts
the power supply to the heaters, so that the heating
elements will not operate while not submerged in the
jacket water.
If steam pressure greater than 50 PSIG is generated
in the jacket, the safety valve will open and relieve
the excess pressure.
If the jacket water level gets too low before the
heating elements overheat, the high-limit control will
open and shut off power to the elements until the
kettle cools.
Setting the operating thermostat dial to “OFF” shuts
down all control and heating circuits.
6. To Empty Kettle
TDB(C) Kettles with Crank Tilt
To tilt the body of the kettle forward, turn the hand
crank on the front of the cabinet anti-clockwise. The
body will stay in the position it holds when you stop
turning the handle. To return the body to the upright
position, turn the crank clockwise.
TDB(C) Kettle with Tilt Handle
The kettle is designed to be tilted in a controlled
manner. Grasp the insulated plastic ball firmly.
Maintain a firm grip on the handle when tilting, while
keeping the kettle body in a tilted position, and when
slowly returning the kettle body to an upright position.
WARNING
DO NOT STAND IN FRONT OF THE KETTLE
BODY WHEN TILTING IT. BE CAREFUL TO
KEEP HOT CONTENTS FROM SPILLING.
ENSURE PEOPLE ARE KEPT AWAY FROM
THE KETTLE WHEN EMPTYING THE KETTLE.
7. Power Failure
If the power to the unit fails do not attempt to operate
the appliance until the electricity supply is re-
established.
When the power comes back on follow the steps in
Paragraph 8.2.1 Initial Kettle Operational Readiness
Check.

20
Use only a sponge, cloth or plastic brush to clean
the kettle.
Scrapers or steel wool can harm the kettle surface.
Cleaning
1. Suggested Tools:
a. Cleaner, such as Klenzade HC-10 or HC-32
from ECOLAB, Inc.
b. Kettle brushes in good condition.
c. Sanitizer such as Klenzade XY-12.
d. Film remover such as Klenzade LC-30.
1. Precautions
Before cleaning, shut off the kettle by turning the
thermostat dial to “OFF,” and shut off all electric
power to the unit at a remote switch, such as the
circuit breaker.
WARNING
KEEP WATER AND SOLUTIONS AWAY FROM
CONTROLS AND ELECTRICAL EQUIPMENT.
NEVER SPRAY THE SUPPORT HOUSING OR
ELECTRICAL CONNECTIONS.
CAUTION
MOST CLEANERS ARE HARMFUL TO THE
SKIN, EYES, MUCOUS MEMBRANES, AND
CLOTHING. PRECAUTIONS SHOULD BE
TAKEN. WEAR RUBBER GLOVES, GOGGLES
OR FACE SHIELD, AND PROTECTIVE
CLOTHING. READ THE WARNINGS AND
FOLLOW THE DIRECTIONS ON THE LABEL
OF THE CLEANER CAREFULLY
3. Procedure
a. Clean food-contact surfaces as soon as
possible after use. If the unit is in continuous
use, thoroughly clean and sanitize the interior
and exterior at least once every 12 hours.
WARNING
AVOID ANY DIRECT CONTACT WITH HOT
SURFACES. DIRECT SKIN CONTACT COULD
RESULT IN SEVERE BURNS.
b. Scrape and flush out food residues. Be
careful not to scratch the kettle with metal
implements.
c. Prepare a hot solution of the detergent/
cleaning compound as instructed by the
supplier. Clean the unit thoroughly. A cloth
moistened with cleaning solution can be used to
clean controls, housings, and electrical
conduits.
d. Rinse the kettle thoroughly with hot water, then
drain completely.
e. As part of the daily cleaning program, clean
soiled external and internal surfaces.
Remember to check the sides of the unit and
control housing.
f. To remove stuck materials, use a brush,
sponge, cloth, plastic or rubber scraper, or
plastic wool with the cleaning solution. To
reduce effort required in washing, let the
detergent solution sit in the kettle and soak into
Other manuals for TDB-20
2
This manual suits for next models
3
Table of contents
Other Groen Kettle manuals

Groen
Groen DEE/4 Series User manual

Groen
Groen capkold DH-400L User manual

Groen
Groen OM-TDB/7 User manual

Groen
Groen EE Domestic User manual

Groen
Groen DEE/4-40C User manual

Groen
Groen TDB/6 Operating manual

Groen
Groen TDBC 20C User manual

Groen
Groen TDB/6 User manual

Groen
Groen AHS-40 User manual

Groen
Groen TDB-20 TA/2 User manual

Groen
Groen EE Domestic User manual

Groen
Groen AH/1E-20 User manual

Groen
Groen TDH-20 C User manual

Groen
Groen TDB/6 Operating manual

Groen
Groen EE-20 User manual

Groen
Groen AH/1E Domestic User manual

Groen
Groen TDB/7 Operating manual

Groen
Groen FT User manual

Groen
Groen DHS-40 User manual

Groen
Groen TDB/8-20-CFC User manual