Agri-Alert 800EZe
ZONE INPUTS
Z5 COM Z6Z3 COM Z4Z1 COM Z2 Z7 COM Z8 1 2
-
COMM
--
++ NO C NC NO C NC ~~
12VDC SIREN RELAY 1 RELAY 2 16VAC
1.5k
1/2W
+
-
Battery /
Batterie
EARTH
+
-
12V
+
-
*The system can
also be powered by
an external source
of 12Vdc
*Le système peut
aussi être alimenté
par une source
d’alimentation
12Vdc
10-feet (3m) metal rod
Tige métallique de 3 mètres (10pi)
12Vdc device, max 500mA
Dispositif 12Vcc, max 500 mA
Siren, max 1A (see Installation notes)
Sirène, max 1A (voir notes d’installation)
Normally open relay (N.O.),
24 Vdc or Vac, 2 A max
Relais normalement ouvert (N.O.),
24Vcc ou Vca, 2 A max
Normally close relay (N.C.),
24 Vdc or Vac, 2 A max
Relais normal.fermé (N.C.),
24Vcc ou Vca, 2 A max
N.O. Circuit with
EOLR resistor
Circuit normalement
ouvert avec résistance
N.O. Circuit without
EOLR resistor
Circuit normalement
ouvert sans résistance
N.C. Circuit without
EOLR resistor
Circuit normalement
fermé sans résistance
N.C. Circuit with
EOLR resistor
Circuit normalement
fermé avec résistance
Power supply,
wall transfo.*
16.5 Vac/4 0 Va
Alimentation,
transfo. mural*
16.5 Vc a/4 0 Va
Comm
Phone card
Carte téléphonique
Battery socket
Connecteur pour batterie
Outdoor card
Carte T° extérieure
891-00441, rev.03
Plug-in Cards / Cartes enfichables
Agri-Alert 800EZe
[EN] Installation Notes
Cable Entry: Punch holes at the bottom of the enclosure
to allow wires to be introduced in the controller. Do not
drill the top or side panels of the enclosure to prevent
water infiltrations.
Mounting the Enclosure on the Wall: Leave a clearance
of at least 12” above the controller to allow the cover
to be removed for maintenance.
Zone Wiring: When connecting a zone, use the “COM”
teminal that is the closest to the zone’s input terminal.
Do not connect more than 2 zones on the same “COM”
terminal.
Siren Wiring: Prior to connecting the siren, make sure
the battery is connected and works properly. If no siren
is used, connect a 1.5KOhm 1/2W resistor between the
positve and negative terminals of the siren or disable the
siren monitoring function as explained in section 3.5 of
the owner’s manual.
[FR] Notes d’installation
Entrée des câbles : Tous les fils entrant dans l’appareil
doivent passer à travers la paroi inférieure du boîtier.
Utiliser un marteau et un poinçon pour percer les trous
qu’il vous faut. Ne jamais percer le dessus ni les côtés
du boîtier pour prévenir les infiltrations d’eau.
Fixation de l’appareil au mur : Laisser un espace libre d’au
moins 12 pouces au-dessus de l’appareil pour permettre
d’ôter le couvercle et d’effectuer l’entretien.
Branchement des zones : Lors du branchement d’une
zone, utiliser le bornier “COM” situé au côté immédiat
du bornier de la zone. Un maximum de 2 zones peuvent
être connectées sur un même bornier “COM”.
Branchement de la sirène : Assurez-vous que la batterie
est branchée et qu’elle fonctionne correctement avant
de brancher la sirène. Si la sirène n’est pas utilisée, relier
une résistance de 1.5kOhm 1/2W entre le bornier positif
et le bornier négatif de la sirène ou désactiver l’option
de la sirène dans l’appareil (consulter la section 3.5 du
manuel de l’usager).
Phone Card
Carte téléphonique
Outdoor T° Card
Carte T° extérieure
Phone line OUT (sortie)
Phone line IN (entrée)
“PHONE CARD” “OUTDOOR”
Ground
(Terre)
Ground
(Terre)
Quick connect pin /
Fiche métallique Quick connect pin /
Fiche métallique
Outside T° sensor /
Sonde T° extérieure
CAUTION – To reduce the risk of fire, use only No. 26 AWG or
larger telecommunication line cord.
ATTENTION – Pour réduire les risques d’incendie, utiliser
uniquement des conducteurs de télécommunications 26 AWG
ou de section supérieure.

Step 1. Installation
Install the Agri-Alert in a location where
a telephone jack, 120 volt AC power
outlet, and proper grounding connections
are readily available.
Step 2. Wiring
Refer to the wiring diagram overleaf.
(Section 1.3) – Install and connect all zone
sensors and the siren. If the alarm system
uses the phone, connect the phone line
to the Phone Plugin Card and then insert
the card in the PHONE CARD port of the
Agri-Alert. If the system uses an outside
temperature sensor, connect the sensor
to the Outdoor Plugin Card and then
insert the card in the OUTDOOR port of
the Agri-Alert. These 2 plugin cards are
optional.
Step 3. Earth Ground
(Section 1.3.9) – Make proper ground
connections. A faulty earth ground con-
nection immediately voids the system
warranty without further notice.
Step 4. Power Supply
Install the battery and then power up the
Agri-Alert with the 16VAC wall trans-
former (note that the system will not boot
when connecting the battery).
Step 5. Installation Wizard
Launch the Installation Wizard (sec. 3.1).
Main menu
Install Programming
Use Program Wizard
Below is a list of all programming steps of
the Installation Wizard. Refer to the proper
section of this manual to get information
about each programming step.
- Time & Date (section 3.3)
- Units of measurement (section 3.4)
- Speaker volume (section 3.6)
- Installer Password (section 3.2)
- Setup Zones (section 3.7)
- Phone Numbers (section 4.3 & 4.4)
- Burglar arming options (section 5.4)
- Siren Options (section 3.5)
- Outdoor T° compensation (sec. 5.3)
Step 6. Activating Zones
(Section 3.7.8)
Main menu
Activate/Bypass
Activate Zones
Step 7. Recording Site ID
(Section 3.8.2) Select the menu below to
record the site’s identification message.
Hierarchy Tree of Controller Menus
Main menu
System Auxiliaries
User Preferences
Voice ID
System Message
Step 8. Phone Call-in
(Section 4.7) – If there is an answering
machine, or fax machine on the same line
as the alarm system, activate the “Share
Phone Line” option. To call the alarm
system from another phone, dial the site
number and allow the site phone to ring
only 1 time and then hang up. Wait 15
seconds and redial the site number. The
Agri-Alert will pick up the call after the
first ring.
Main menu
View / Modify
Phone Call-in
Step 9. System Test
(Section 3.8.5) As a final step, always
perform a system test. A successful test
tells the Agri-Alert is ready to operate. It
is recommanded to perform this test on
a regular basis.
Main menu
Auto-Test
Agri-Alert 800EZe – Quick Installation Guide
Main Menu
Current Conditions sec. 6.2
View / Modify
Activate / Bypass sec. 5.5
System Self Test sec. 3.8.5
System Auxiliaries
Help Menus sec. 2.2
Install Programming
Zone Settings sec. 5.5.2
Phone Numbers sec. 4.4
Auto-Test Schedule sec. 4.9
Outdoor Probe sec. 5.3
Output Relays sec. 3.8.4
Siren Settings sec. 3.5
Burglar Zone Delays sec. 5.4.1
Phone Call-in sec. 4.7
On-Site Listening sec. 4.6
High Noise Alarm sec. 3.8.3
Time & Date sec. 3.3
Units sec. 3.4
Voice Volume sec. 3.6
Voice ID sec.
3.7.7 &
3.8.2
Update / Backup ch.10
Password Manage-
ment sec. 3.2
Event Buffer sec. 6.3
User Preferences
Software Version sec. 3.8.6
Change User sec. 3.2.2
Use Program Wizard sec. 3.1
Program Zones sec. 3.7
Program Dialer sec. 4.3
Program Auxiliaries
Phone Enabled Zones sec. 4.8
Siren Enabled Zones sec. 3.7.6
Relay Assigned
Zones sec. 3.7.5
Étape 5. Programmation
Section 3.1 – Lancez l’assistant de pro-
grammation.
Menu principal
Installation
Assistant program.
Voici la liste des étapes parcourues par
l’assistant de programmation. Référez-
vous au manuel de l’usager pour obtenir
plus d’information.
- Date & heure (section 3.3)
- Unités de mesure (section 3.4)
- Volume du haut-parleur (section 3.6)
- Mot de passe installateur (section 3.2)
- Configuration des zones (section 3.7)
- Numéros de tél. (section 4.3 & 4.4)
- Paramètres d’armement (section 5.4)
- Paramètres de la sirène (section 3.5)
- Compensation T° extérieure (sec. 5.3)
Étape 6. Activation des zones
(Section 3.7.8)
Menu principal
Activer/ Supprimer
Activer une zone
Étape 7. Message d’identification
(Section 3.8.2) – Sélectionnez le menu
suivant pour enregistrer le message
d’identification du site.
Étape 1. Installation
Installez le système d’alarme là où une
prise de téléphone, une prise 120 volt CA,
et les installation pour la mise à la terre
sont facilement accessibles.
Étape 2. Branchements
Consultez le schéma de branchement au verso.
(Section 1.3) – Installez et branchez les
détecteurs des zones et la sirène. Si la
ligne téléphonique est utilisée, reliez le té-
léphone à la carte enfichable téléphonique
puis insérez la carte dans le port “PHONE
CARD” de l’appareil. Si une sonde de
température extérieure est utilisée,
branchez-la sur la carte enfichable pour
la lecture de température extérieure puis
insérez la carte dans le port “OUTDOOR”
de l’appareil (voir au verso). Notez que
ces 2 cartes sont optionnelles.
Étape 3. Mise à la terre
(Section 1.3.9) – Effectuez une mise à la
terre conforme de l’appareil. Une mise à
la terre insufisante annule immédiatement
la garantie sans préavis.
Étape 4. Alimentation
Branchez d’abord la batterie puis ali-
mentez l’appareil avec le transformateur
mural 16 VCA (notez que le système ne
démarrera pas lors de la connexion de la
batterie).
Menu principal
Système auxiliaire
Préférences
Message vocal
Message système
Étape 8. Réception d’appel
(Section 4.7) Si un répondeur ou un té-
lécopieur partage la ligne téléphonique de
l’Agri-Alerte, activez le paramètre “Part-
age de la ligne”. Pour appeler un module
Agri-Alerte qui utilise une ligne partagée,
vous devez composer le numéro de télé-
phone du site, laisser sonner une seule fois
puis raccrocher. Recomposez le numéro
du site après 15 secondes, l’Agri-Alerte
répondra dès la première sonnerie.
Menu principal
Voir / modifier
Réception d’appels
Étape 9. Essai du système
(Section 3.8.5) Avant d’utiliser votre
système Agri-Alerte, effectuez un test
sur l’appareil pour vous assurer de son
bon fonctionnement. Il est recommandé
d’effectuer ce test régulièrement.
Menu principal
Auto-test système
Arborescence des menus
Agri-Alert 800EZe – Guide d’installation rapide
Menu principal
Conditions courantes sec. 6.2
Voir / Modifier
Activer / Supprimer sec. 5.5
Auto test du système sec. 3.8.5
Système auxiliaire
Menus d'aide sec. 2.2
Installation
Réglages des zones sec. 5.5.2
Numéros tél. sec. 4.4
Horaire d'auto-test sec. 4.9
Sonde extérieure sec. 5.3
Sorties relais sec. 3.8.4
Réglages de la sirène sec. 3.5
Délais zone de vol sec. 5.4.1
Réception d'un appel sec. 4.7
Écoute à distance sec. 4.6
Haut niveau de bruit sec. 3.8.3
Date et heure sec. 3.3
Unités sec. 3.4
Volume sec. 3.6
Message vocal sec.
3.7.7 &
3.8.2
Mise à jour / sauver chapt.10
Mots de passe sec. 3.2
Registre événements sec. 6.3
Préférences
Version du logiciel sec. 3.8.6
Changer d'utilisateur sec. 3.2.2
Assistant de program. sec. 3.1
Program. des zones sec. 3.7
Program. du téléphone sec. 4.3
Program. auxiliaires
Phone Enabled Zones sec. 4.8
Siren Enabled Zones sec. 3.7.6
Relay Assigned
Zones sec. 3.7.5
Other manuals for Agri-Alert 800EZe
1
Other GSI Electronics Security System manuals
Popular Security System manuals by other brands

Alderon Industries
Alderon Industries Versa'larm VA02A Operation, maintenance and installation manual

Baby Alert
Baby Alert ChildMinder quick start guide

Assistive Technology Services
Assistive Technology Services Touch N Talk troubleshooting guide

SiKom
SiKom A-Comfort User and installation manual

Curv360
Curv360 MS-06B manual

Ingrid
Ingrid Security System user manual