I-9403
Intelligent Sounder Strobe
T
he Intelli
g
ent Solution
Features
Providing two tones.
Using several high red LEDs as light source.
Initiated by shorting external terminals; not affected by
loop power cut.
Signal loop and power loop are polarity-insensitive,
which is convenient for wiring and features power-off
checking.
Standard: EN 54-3.
Description
I-9403 Intelligent Sounder Strobe is a kind of audible and
visual alarm device installed in field, which can be initiated by
fire alarm control panel in fire control center or by manual call
point installed in field. Having been initiated, it will generate
strong audible and visual alarm signal to warn people in field.
Both shallow base with 25.5mm high and deep base with
40mm high are available, deep base is used if there is no
special statement in this manual.
Connection & Wiring
Terminals on the base are shown in Fig. 2.
G
1
K
1
D
D
2
1
2
Z
2
K
S
Z
97.5mm 80mm
55mm
Arch knock off Hole
5mm
Fig.1 Fig.2
Z1 (2), Z2 (4): To control panel loop, polarity-insensitive.
D1 (9), D2 (7): To 24VDC power, polarity-insensitive.
S (5), G (10): External volt-free input.
Recommended Wiring
1.5mm2 or above fire cable for power wire D1, D2 and
external wire S, G; 1.0mm2or above fire cable for other
terminals, subject to local codes.
Installation
When the sounder strobe is surface mounted, it should
be placed 0.2m from the ceiling for normal space height.
When conduit is embedded, the base can be mounted on the
electrical box. When conduit is surface mounted, the deep
base should be adopted. Knock the knock-off hole, then
connect the conduit with it. The mounting hole spacing and
mounting direction are shown in Fig. 2. Mounting method is
shown in Fig. 3a and Fig. 4. When the shallow base is
required, the sounder strobe only adopts conduit embedded.
Its mounting method is shown in Fig. 3b.
The base and the sounder strobe are twisted together.
When mounting, remove the sounder strobe, thread cables
through cable entry in the base and connect with
corresponding terminals, then twist the sounder strobe onto
the base.
If the sounder strobe is required anti-removal, knock
down the arch knock-off hole as shown in Fig. 1 and fix it with
ST2.9×6.5 tapping screws (in this case, it must be removed
by a special tool).
0832-CPD-0448
548e/02
Sounder Strobe
Knock-off Hole
Conduit
Electrical Box
Fig. 3a
Electrical Box
Conduit Sounder Strobe
Fig.3b
Sounder Strobe
Conduit
Fig. 4
Application
Address can be programmed through a programmer. Refer
to P-9910B Hand Held Programmer Installation and
Operation Manual for further details.
The sounder strobe occupies two consecutive
addresses when its device type is 121. It occupies one
30302714 Issue 2.05
HTTP://GSTRU.RUE-MAIL: [email protected]
HTTP://WWW.HOMBI.RU
30302714 Issue 2.05
address when its device type is other numbers (factory
default is 27).
Two initiating methods in Tone I:
¾Short the terminals S and G to initiate the sounder
strobe.
¾When the sounder strobe occupies two addresses,
the first one should be initiated through the control
panel.
Two initiating methods in Tone II:
¾When the sounder strobe occupies one address, it
can be initiated through the control panel.
¾When the sounder strobe occupies two addresses,
its second one should be initiated through the control
panel.
The wiring of the sounder strobe and direct control
through volt-free normally open contact of the manual call
point are shown in Fig. 5.
ManualCallPoint
Z2
D2
S
K1Z1
Z2 K2
Z2
GZ1
D1
GND
Z1
+24V
Sounder Strobe
Fig. 5
Sound Level Data (EN54-3 approved)
Alarm, Maximum Volume
Angle Horizontal Vertical
20V 28V 20V 28V
15° 75.19 77.17 72.85 72.31
45° 84.01 87.07 82.57 85.63
75° 87.61 90.85 86.98 89.32
105° 87.43 90.22 88.42 90.67
135° 83.11 86.17 83.65 86.80
165° 70.60 73.84 75.55 77.98
Pre-alarm, Maximum Volume
Angle Horizontal Vertical
20V 28V 20V 28V
15° 72.67 75.73 61.15 65.11
45° 80.50 83.20 78.61 81.40
75° 84.37 87.25 83.56 86.53
105° 83.65 86.53 84.91 88.15
135° 79.51 82.57 80.32 83.65
165° 66.10 69.61 70.78 74.11
Specification
Operating Voltage Loop: 24V
Power: 24VDC
Standby Current Loop≤1mA Power≤3mA
Action Current Loop≤5mA Power≤50mA
Wiring Four-wire, connecting with
polarity-insensitive loop.
Polarity-insensitive two-wire for
connecting power.
Tone I Sound Level: See the above sound
level data table
Flashing Frequency: 0.7 ×
(1±20%)Hz
Sound Pattern: 2.8KHz (430ms on
/1200ms off)
Tone II Sound Level: See the above sound
level data table
Flashing Frequency: 1.4×(1±20%)
Hz
Sound Pattern: 2.8KHz (430ms on
/340ms off)
Programming Mode Electronically addressed
Programming Range Occupying 1 or 2 (when device type
is 121) address within 1~242.
Ingress Protection
Rating IP33
Operating
Temperature -10℃~+50℃
Relative Humidity ≤95%, non condensing
Material and Color of
Enclosure ABS, red (PANTONE 1795C)
Dimension
(L×W×H) ф110mm×97.5mm
ф110mm×83mm(shallow base)
Mounting Hole
Spacing 55mm~80mm
Weight About 355g (deep base)
About 327g (shallow base)
Accessories and Tools
Model Name Remark
P-9910B Hand Held
Programmer Supplied Separately
C-94DB Base Supplied Separately
Limited Warranty
GST warrants that the product will be free from defects in
design, materials and workmanship during the warranty
period. This warranty shall not apply to any product that is
found to have been improperly installed or used in any way
not in accordance with the instructions supplied with the
product. Anybody, including the agents, distributors or
employees, is not in the position to amend the contents of
this warranty. Please contact your local distributor for
products not covered by this warranty.
GST Chi
Gulf Se na
curity Technology Co., Ltd.
ngjiang East Road, QETDZ,
angdao, Hebei,
. R. China 066004
Tel: +86 (0) 335 8502528
Fax: +86 (0) 335 8508942
[email protected]
No. 80, Cha
Qinhu
P
This document is subject to change without notice. Please contact GST for more information or questions.
GST UK
Global System Technology PLC
Lion Court, Staunton Harold Hall,
Melbourne Road, Ashby de la Zouch,
Leicestershire, England LE65 1RT
Tel: +44 1283 225 478
Fax: +44 1283 220 690
[email protected]
GST Dubai
Global System Technology PLC
PO Box 17998 Unit ZA04
JEBELALI Free Zone,
Dubai, UAE
Tel: +971 (0) 4 8833050
Fax: +971 (0) 4 8833053
[email protected]
www.gst.com.cn
www.gst.uk.com
www.gst.uk.com
HTTP://GSTRU.RUE-MAIL: [email protected]

Other GST Marine Equipment manuals

GST C-9404 User manual

GST

GST C-9404 User manual

GST DC-M9416 Series Assembly instructions

GST

GST DC-M9416 Series Assembly instructions

GST C-9402 User manual

GST

GST C-9402 User manual

GST I-9404 User manual

GST

GST I-9404 User manual

GST C-9404(Ex) User manual

GST

GST C-9404(Ex) User manual

GST DC-9404(IS) User manual

GST

GST DC-9404(IS) User manual

GST I-9404 User manual

GST

GST I-9404 User manual

GST C-9402 User manual

GST

GST C-9402 User manual

GST I-9404 User manual

GST

GST I-9404 User manual

GST C-9403 User manual

GST

GST C-9403 User manual

GST C-9402 User manual

GST

GST C-9402 User manual

GST C-9404(Ex) User manual

GST

GST C-9404(Ex) User manual

Popular Marine Equipment manuals by other brands

Maxwell 3500 Series manual

Maxwell

Maxwell 3500 Series manual

Furuno FI-302 Operator's manual

Furuno

Furuno FI-302 Operator's manual

Zenitel Vingtor VSS Installation & service manual

Zenitel

Zenitel Vingtor VSS Installation & service manual

werma 140 Instructions for use

werma

werma 140 Instructions for use

Garmin GPSMAP 168 Sounder Owner's manual and reference guide

Garmin

Garmin GPSMAP 168 Sounder Owner's manual and reference guide

Raymarine autopilot ST4000+ Owner's handbook

Raymarine

Raymarine autopilot ST4000+ Owner's handbook

Simrad SimNet Installation & use

Simrad

Simrad SimNet Installation & use

Syqwest Bathy 2010P Operation and maintenance manual

Syqwest

Syqwest Bathy 2010P Operation and maintenance manual

ALBIN PUMP Marine Defroster 9 kW Instructions for use

ALBIN PUMP

ALBIN PUMP Marine Defroster 9 kW Instructions for use

Katadyn PowerSurvivor 80E owner's manual

Katadyn

Katadyn PowerSurvivor 80E owner's manual

ESP MAGDUO MAGDUOSRSQ Installation and maintenance instructions

ESP

ESP MAGDUO MAGDUOSRSQ Installation and maintenance instructions

JRC JUE-95SA - Operation guide

JRC

JRC JUE-95SA - Operation guide

Simrad ED162 Operator's manual

Simrad

Simrad ED162 Operator's manual

Jensen MCD4030 owner's manual

Jensen

Jensen MCD4030 owner's manual

Mercury VesselView 703 quick guide

Mercury

Mercury VesselView 703 quick guide

Zeta Alarm Limited MKII-AXTB/R installation manual

Zeta Alarm Limited

Zeta Alarm Limited MKII-AXTB/R installation manual

Fusion 750 Series manual

Fusion

Fusion 750 Series manual

Lowrance ELITE Ti2 quick guide

Lowrance

Lowrance ELITE Ti2 quick guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.