Programming
Four programs are available to program your
week: P1, P2, P3 which are pre-recorded and
not modifiable and P4 which is free and allows
you to create a personalised program that can
be dierent for each day of the week.
Assigning an existing program (P1, P2 or
P3) to one or more days of the week
You can assign any of the programs to all
7 days of the week, to a group of five week-
days, to a group of two days for the weekend
or to an individual day.
• Press key 1 menu to place the cursor
under prog. The indicators for the seven
days of the week flash.
• Press key 4+to select which day, or group
of days, to assign a program to.
Confirm using the OK key.
•
P1 flashes. Press key 4+to select the
program to apply.
Confirm using the OK key.
As an example, to assign P2 to the group
of five weekdays and P1 to the group of two
weekend days:
• Press key 1 menu to place the cursor
under prog. The indicators for the seven
days of the week flash.
• Press key 4+to select to aect the group
of five days (the group of five days flashes).
Confirm using the OK key.
•
P1 flashes. Press key 4+to select
(P2 flashes). Confirm using the OK key.
• Press key 4+to select the group of
2 weekend days (the group of 2 weekend
days flashes).
Confirm using the OK key.
•
P1 flashes. Confirm using the OK key.
The thermostat returns to auto mode.
Creation of a personalised program P4
This program allows you to adjust the heating
to suit your way of life.
A 24-hour profile is composed of 48 points
(representing the set-points). You can visualise
the composition of your program at the bottom
of the display. 1 program step = 30 minutes.
Example: creating a program, P4, for a group
of days (5 weekdays + 2 weekend days).
For the 5 weekdays, we would like 3 Comfort
periods from 06:00 to 08:00, from 12:00 to 14:00
and from 18:00 to 22:00.
For the two-week in days, we would like one
Comfort period from 08:00 to 22:00.
• Press key 1 menu to place the cursor under
prog. The indicators for the seven days of the
week flash.
• Press key 4+to select to aect the group of
five days (the group of five days flashes).
Confirm using the OK key.
• P1 ashes. Press key 4+to select P4
(P4 flashes). Confirm using the OK key.
• Press key 1until 6:00 appears and key 2
until 8:00 appears. Next press key 1until
12:00 and key 2until 14:00. Then press key
1until 18:00 and finally key 2until 22:00.
If you make an error, press key 4 –to move back
or key 4+to advance and correct your program-
ming.
• Conrm using the OK key.
• The group of 2 weekend days ashes.
Confirm using the OK key.
•
P1 flashes. Press key 4+to select P4
(P4 flashes). Validez avec la touche OK.
• Press key 1until 8:00 is reached and
then press key 2until 22:00.
Confirm using the OK key.
Note:
The latest P4 program is held in memory and
automatically oered to be assigned to a new day
or group of days (whose P4 is empty).
Temporary override
By overriding until the next program step
In auto mode, it is possible to modify the tempera-
ture of the current set-point.
• Press key 4 +or -to increase or decrease
the displayed set-point temperature.
The set-point temperature flashes and the override
is valid until the next program step.
During the override period, the current set-point
temperature flashes.
What to do if... ?
The symbol is displayed :
change the batteries (2 alkaline batteries of type
LR06 1.5 V) as soon as possible.
Technical characteristics
Power supply: 2 alkaline batteries 1,5V (type LR06)
Battery lifespan: 4 years
Static dierential (On/O regulation): < 0,3 °C
Power reserve: 10 min.
Adjustment range:
- Comfort temperature: +5°C to +30°C
- Eco temperature: +5°C to +30°C
Ambient temperature display range:
0°C to +40°C
Operating temperature: +0°C to +45°C
Storage temperature: -25°C to +70°C
Ball test temperature: 75°C and 125°C
Clock operating accuracy: drifts < 1sec/day
Trip values: 230V v5A resistive / 3A inductive
Minimum load excepted by the relay: 12V/10mA
Relative humidity: 90 % at 20°C
IP: 30
Ecodesign class: 4
IK: 04
Insulation class: II
Insulation type: 4kV
Rigid cable cross-sections: 0,5 to 2,5 mm²
Flexible cable cross-sections: 0,5 to 1,5 mm²
Minimum pulse voltage: 4 kV
Pollution class: 3
Action type: 2B
Insulation type: reinforced insulation
Software structure: class A
Dimensions (l x h x d): 97 x 138 x 30
Voltage and current declared for the needs of
EMC emissions tests: 230V v0,5A
Upstream protection: circuit breaker 6A
Independent installation device for built-in
installation
3 6LE001541B
Usable in all Europe
å
and in Switzerland
Correct Disposal of This product
(Waste Electrical & Electronic
Equipment)
(Applicable in the European Union and other European
countries with separate collection systems).
This marking shown on the product or its literature
indicates that it should not be disposed with other
household wasted at the end of its working life. To
prevent possible harm to the environment or human
health from uncontrolled waste disposal, please
separate this from other types of wastes and recycle it
responsibly to promote the sustainable reuse of
material resources. Household users should contact
either the retailer where they purchased this product,
or their local government office, for details of where
and how they can take this item for environmentally
safe recycling.
Business users should contact their supplier and
check the terms and conditions of the purchase
contract. This product should not be mixed with other
commercial wastes of disposal.
P1 = Comfort temperature from 06:00 to 23:00.
Eco temperature from 23:00 to 06:00.
P1 is activated 7 days per week
by default. If this fits the rhythm
of your life then remain in automatic
mode; if not, continue.
P4 = a free program which allows you to
create up to 5 Comfort temperature
periods and 5 Eco temperature periods,
for each of the days of the week.
P2 = Comfort temperature from
06:00 to 08:30 and from 16:30 to 23:00.
Eco temperature from
08:30 to 16:30 and from 23:00 to 06:00.
P3 = Comfort temperature from
06:00 to 08:30, from 11:30 to 13:30
and from 16:30 to 23:00.
Eco temperature from
08:30 to 11:30, from 13:30 to 16:30
and from 23:00 to 06:00.
30 min. in Eco 30 min. in Comfort