Product description
1Context key for menu access
2Context key for mode access holidays
3 Confirmation key OK
4Adjustment keys +and -
5Indicator for days of the week
6Automatic mode/manual mode
(thermostat without program)
7Temperature settings adjustment
8Standby
9Programming/program selection
ATime and date adjustment
ZAdjustment of settings
EAmbient temperature
RHeating indicator
TCurrent setting ( , , )
YTemperature of current setting
UBattery use indicator
IProfile of today's program
OCurrent time
Electrical installation and connections
To guarantee its ambient temperature-regulation
function, the thermostat should be installed around
1.3 m above the ground, on an interior wall and
away from direct sunlight or any heat source such
as a television, lamp, radiator, draft, chimney, etc.
Fix the thermostat onto the flush-mounted casing or
in the slot without a casing intended for this purpose.
For optimum quality temperature regulation, seal
the flush-mounted casing or the electrical duct.
1. Separate the product from the wall-mounted
base, by pushing on the button located under
the base.
2. Open the flap with the help of a screwdriver and
attach the wall-mounted base using the screws.
3. Next, pass the electrical cables into the holes
intended for this purpose.
NJ
l
1
/

 
$
Connection of the thermostat to a thermos-
tat input on the boiler
Connection of a heat circulator
4. Connect the product according to the wiring
diagram below.
5. Reclose the flap
6. Insert the batteries into the thermostat.
7. Clip the front face onto the wall-mounted
base.
EK570
ok
–+
1 6LE001541B
6LE001541B
zProgrammable ambient thermostat,
2 wire, weekly, battery powered
Notice d’instructions
This programmable ambient thermostat has been designed to bring you comfort and energy eco-
nomy. It allows you to program and regulate your heating system at 3 temperature levels:
- Comfort : this is the temperature you desire during the hours you are present.
- Eco : this is the temperature you desire during short absences or at night.
- Frost protection : this is the guaranteed minimum temperature during your prolonged absences.
It protects your accommodation against the dangers of frost.
ok
–+
Navigation &
Réglage des valeurs
Validation
Antenne DCF
(en option)
Entrer en mode PROGRAMME &
Retourner à l’étape précédente
Sélection des jours
de la semaine
(1 = lundi, 2 = mardi...
7 = dimanche)
Commande Canal B
Commande Canal C
Commande Canal D
Commande Canal A
Verrouillage Code PIN
menu +ok


3./
–+
ok
–+
ok








30%
TOP
Angle ouverture 120°
TOP
TOP
TOP
TOP
TOP
TOP
NJ
l
1
/

 
$

HQWUÆH
WKHUPRVWDWGDPELDQFHGÆSRUWÆ
)5
 
HQWUÆH
WKHUPRVWDWGDPELDQFH
GÆSRUWÆ
WÆOÆFRPPDQGHWÆOÆSKRQLTXH
UÆI7+

(LQJDQJ
5DXPWKHUPRVWDW
'(

LQSXW
IURPUHPRWHDPELHQWWKHUPRVWDW
*%

LQJDQJ
NDPHUWKHUPRVWDDWRSDIVWDQG
1/

ZHMŪFLH
WHUPRVWDWSRNRMRZ\]HZQĸWU]Q\
3/

WXOR
XONRLVHVWDKXRQHWHUPRVWDDWLVWD
),

LQJUHVVR
WHUPRVWDWRDPELHQWHUHPRWR
,7

HQWUDGD
7HUPRVWDWRGHDPELHQWHGHVYLDGR
(6

DZȌȀǼǰǼǿ
ǴDZǾǹǼȀȁȉȁdzǿȅȓǾǼȂ
ǹDZǭǽǼǹǭǷǾȂȀǹȊǺǼǭǶȀǴdzȁȋǾǶǼ
*5
1
/
 



 




 
5HVHW
5HVHW
5HVHW
5HVHW
This product must be installed
according to the local standards
in force.
Initial adjustment and updating
when the product is first used, the screen
oers the option to adjust the year, date and
time, without going into the parameter settings.
or
Press key 1menu to place the cursor under
.
• The year flashes, press key 4+the naviga-
tion key to adjust the current year.
Confirm using the OK key.
• The month ashes. Now press key 4 +or -.
Confirm using the OK key then proceed
in the same manner to select the day, hour
and minutes.
•
AUTO AUTO flashes. Press key 4+to set
the installation to switch automatically
between summer and winter time (auto) or
not (off). Confirm using the OK key.
•
24 :H flashes. Press key 4+and select
the 12 hour or 24 hour time format.
Confirm using the OK key.
Automatic mode (auto)
In automatic mode, the thermostat adapts
itself to the rhythm of your life by applying
one or more programs that you have selected.
• Press key 1 menu to place the cursor
under auto.
Key 1menu allows you to return to auto
mode when the (holiday) program is running.
Manual mode (manu)
Manual mode transforms your equipment into
a simple thermostat. It allows you to maintain
a constant temperature in your accommodation
(adjustable from +5°C to +30°C) and ignores
the available program profiles.
• Press key 1 menu to place the cursor
under manu.
• Press key 4+or -to adjust the desired
temperature.
Example: the desired temperature is at 22.5°C
and the ambient temperature at 20°C.
The heating running indicator R is illuminated.
Standby mode
The heating system can be put on standby.
The thermostat is live and protects your instal-
lation if the temperature drops below
5 °C (fixed non-modifiable instruction). It dis-
plays the time, current day, ambient tempera-
ture and
O information.
• Press key 1menu to place the cursor
under .
OFfflashes.
• Conrm using the OK key.
• Press key 1menu to exit standby mode.
Installer parameters
To access all of the parameters (from PA :3 to PA :12), press key 1menu to place the cursor under
then give 1 long push (>5s) on OK.
PA :3 - Temperature calibration
This parameter lets you adjust the value displayed by the thermostat if you measure a dierent
ambient temperature to that which the thermostat measures.
• Press key 4+or -to modify the temperature within a range of +/-3°C.
Confirm using the OK key to pass to the next parameter.
PA :6 - Degumming the pump
This parameter allows you to activate/deactivate the automatic start-up of the pump at midnight eve-
ryday, in order to avoid its jamming during the summer.
• Press key 4+or -to activate (ON) ) or deactivate (oFF).
Confirm using the OK key to pass to the next parameter.
Parameter PA :6 is set to OFF by default.
PA :10 - Return to factory settings
This parameter lets you return programs and parameters to the factory settings.
• Press key 4+or -to choose Yes (reset) or no (no de reset).
Confirm using the OK key to pass to the next parameter.
PA :12 - Software version
This parameter displays which version of the software is installed in the product.
Press OK to exit from parameter adjustments.
User parameters
To access the user parameters, press key 1menu to place the cursor under and confirm using
the OK key.
PA :3 - Temperature calibration
This parameter lets you adjust the value displayed by the thermostat if you measure a dierent
ambient temperature to that which the thermostat measures.
• Press key 4+or -o modify the temperature within a range of +/-3°C.
Confirm using the OK key.
Once adjustment of this parameter is carried out, the thermostat switches to auto mode and takes
account of this modification.
Holiday mode
This mode protects your accommodation against
the dangers of frost and maintains a minimum
temperature during your absences, which can be
adjusted between 5°C and 30°C. You can
program the duration of your absence to anticipate
a rise in temperature for your return.
• Press key 2 , press key 4+to select
the number of days absence (from 1 to 99 days).
The current day counts as 1.
Confirm using the OK key.
• The icon appears and the temperature to be
adjusted flashes.
• Press key 4+or -to indicate the desired
temperature value. Confirm using the OK key.
Leave the thermostat in this mode. To cancel and
return to automatic mode, press key 1 menu.
• To modify the duration of your absence or the
temperature value, press key 2and proceed
to the changes.
Adjusting the temperature set-points
The temperatures are preset:
Comfort = 19°C, Eco = 16°C.
The adjustment range for the heating settings
is from 5°C to 30°C.
Modification of the Comfort temperature
• Press key 1 menu to place the cursor under .
The Comfort temperature v flashes.
• Press key 4+or -to modify the temperature.
Confirm using the OK key.
Modification of the Eco temperature
• The Eco temperature flashes.
• Press key 4+or -to modify the temperature.
Confirm using the OK key.
2 6LE001541B
Programming
Four programs are available to program your
week: P1, P2, P3 which are pre-recorded and
not modifiable and P4 which is free and allows
you to create a personalised program that can
be dierent for each day of the week.
Assigning an existing program (P1, P2 or
P3) to one or more days of the week
You can assign any of the programs to all
7 days of the week, to a group of five week-
days, to a group of two days for the weekend
or to an individual day.
• Press key 1 menu to place the cursor
under prog. The indicators for the seven
days of the week flash.
• Press key 4+to select which day, or group
of days, to assign a program to.
Confirm using the OK key.
•
P1 flashes. Press key 4+to select the
program to apply.
Confirm using the OK key.
As an example, to assign P2 to the group
of five weekdays and P1 to the group of two
weekend days:
• Press key 1 menu to place the cursor
under prog. The indicators for the seven
days of the week flash.
• Press key 4+to select to aect the group
of five days (the group of five days flashes).
Confirm using the OK key.
•
P1 flashes. Press key 4+to select
(P2 flashes). Confirm using the OK key.
• Press key 4+to select the group of
2 weekend days (the group of 2 weekend
days flashes).
Confirm using the OK key.
•
P1 flashes. Confirm using the OK key.
The thermostat returns to auto mode.
Creation of a personalised program P4
This program allows you to adjust the heating
to suit your way of life.
A 24-hour profile is composed of 48 points
(representing the set-points). You can visualise
the composition of your program at the bottom
of the display. 1 program step = 30 minutes.
Example: creating a program, P4, for a group
of days (5 weekdays + 2 weekend days).
For the 5 weekdays, we would like 3 Comfort
periods from 06:00 to 08:00, from 12:00 to 14:00
and from 18:00 to 22:00.
For the two-week in days, we would like one
Comfort period from 08:00 to 22:00.
• Press key 1 menu to place the cursor under
prog. The indicators for the seven days of the
week flash.
• Press key 4+to select to aect the group of
five days (the group of five days flashes).
Confirm using the OK key.
• P1 ashes. Press key 4+to select P4
(P4 flashes). Confirm using the OK key.
• Press key 1until 6:00 appears and key 2
until 8:00 appears. Next press key 1until
12:00 and key 2until 14:00. Then press key
1until 18:00 and finally key 2until 22:00.
If you make an error, press key 4 –to move back
or key 4+to advance and correct your program-
ming.
• Conrm using the OK key.
• The group of 2 weekend days ashes.
Confirm using the OK key.
•
P1 flashes. Press key 4+to select P4
(P4 flashes). Validez avec la touche OK.
• Press key 1until 8:00 is reached and
then press key 2until 22:00.
Confirm using the OK key.
Note:
The latest P4 program is held in memory and
automatically oered to be assigned to a new day
or group of days (whose P4 is empty).
Temporary override
By overriding until the next program step
In auto mode, it is possible to modify the tempera-
ture of the current set-point.
• Press key 4 +or -to increase or decrease
the displayed set-point temperature.
The set-point temperature flashes and the override
is valid until the next program step.
During the override period, the current set-point
temperature flashes.
What to do if... ?
The symbol is displayed :
change the batteries (2 alkaline batteries of type
LR06 1.5 V) as soon as possible.
Technical characteristics
Power supply: 2 alkaline batteries 1,5V (type LR06)
Battery lifespan: 4 years
Static dierential (On/O regulation): < 0,3 °C
Power reserve: 10 min.
Adjustment range:
- Comfort temperature: +5°C to +30°C
- Eco temperature: +5°C to +30°C
Ambient temperature display range:
0°C to +40°C
Operating temperature: +0°C to +45°C
Storage temperature: -25°C to +70°C
Ball test temperature: 75°C and 125°C
Clock operating accuracy: drifts < 1sec/day
Trip values: 230V v5A resistive / 3A inductive
Minimum load excepted by the relay: 12V/10mA
Relative humidity: 90 % at 20°C
IP: 30
Ecodesign class: 4
IK: 04
Insulation class: II
Insulation type: 4kV
Rigid cable cross-sections: 0,5 to 2,5 mm²
Flexible cable cross-sections: 0,5 to 1,5 mm²
Minimum pulse voltage: 4 kV
Pollution class: 3
Action type: 2B
Insulation type: reinforced insulation
Software structure: class A
Dimensions (l x h x d): 97 x 138 x 30
Voltage and current declared for the needs of
EMC emissions tests: 230V v0,5A
Upstream protection: circuit breaker 6A
Independent installation device for built-in
installation
3 6LE001541B
Usable in all Europe
å
and in Switzerland
Correct Disposal of This product
(Waste Electrical & Electronic
Equipment)
(Applicable in the European Union and other European
countries with separate collection systems).
This marking shown on the product or its literature
indicates that it should not be disposed with other
household wasted at the end of its working life. To
prevent possible harm to the environment or human
health from uncontrolled waste disposal, please
separate this from other types of wastes and recycle it
responsibly to promote the sustainable reuse of
material resources. Household users should contact
either the retailer where they purchased this product,
or their local government office, for details of where
and how they can take this item for environmentally
safe recycling.
Business users should contact their supplier and
check the terms and conditions of the purchase
contract. This product should not be mixed with other
commercial wastes of disposal.
P1 = Comfort temperature from 06:00 to 23:00.
Eco temperature from 23:00 to 06:00.
P1 is activated 7 days per week
by default. If this fits the rhythm
of your life then remain in automatic
mode; if not, continue.
P4 = a free program which allows you to
create up to 5 Comfort temperature
periods and 5 Eco temperature periods,
for each of the days of the week.
P2 = Comfort temperature from
06:00 to 08:30 and from 16:30 to 23:00.
Eco temperature from
08:30 to 16:30 and from 23:00 to 06:00.
P3 = Comfort temperature from
06:00 to 08:30, from 11:30 to 13:30
and from 16:30 to 23:00.
Eco temperature from
08:30 to 11:30, from 13:30 to 16:30
and from 23:00 to 06:00.
30 min. in Eco 30 min. in Comfort
4 Hager Controls S.A.S., 33 rue Saint-Nicolas, B.P. 10140, 67703 SAVERNE CEDEX, France - www.hager.com 08.2017 6LE001541B

Other hager Thermostat manuals

hager EK052 Installation instructions

hager

hager EK052 Installation instructions

hager kallysta WK310 User manual

hager

hager kallysta WK310 User manual

hager EK560 User manual

hager

hager EK560 User manual

hager 25113 User manual

hager

hager 25113 User manual

hager WE310 User manual

hager

hager WE310 User manual

hager 25614 Installation instructions

hager

hager 25614 Installation instructions

hager Flash 25620 User manual

hager

hager Flash 25620 User manual

hager 25501 User manual

hager

hager 25501 User manual

hager Bocchiotti 25310 User manual

hager

hager Bocchiotti 25310 User manual

hager essensya WE310 User manual

hager

hager essensya WE310 User manual

hager EK760 User manual

hager

hager EK760 User manual

hager EK004 User manual

hager

hager EK004 User manual

hager tebis tx460 User manual

hager

hager tebis tx460 User manual

hager WS310 systo User manual

hager

hager WS310 systo User manual

hager WH104404 User manual

hager

hager WH104404 User manual

hager EK005, 25505 User manual

hager

hager EK005, 25505 User manual

hager EK510 User manual

hager

hager EK510 User manual

hager EK051 User manual

hager

hager EK051 User manual

hager 54185 User manual

hager

hager 54185 User manual

hager kallysto WUC70 User manual

hager

hager kallysto WUC70 User manual

hager 54185 User manual

hager

hager 54185 User manual

hager EK520 User manual

hager

hager EK520 User manual

hager 58102 User manual

hager

hager 58102 User manual

hager WH104405 Series User manual

hager

hager WH104405 Series User manual

Popular Thermostat manuals by other brands

Aprilaire 8537 Specifications

Aprilaire

Aprilaire 8537 Specifications

Lux Products TX1500E operating instructions

Lux Products

Lux Products TX1500E operating instructions

Living Heat SmartLife CT1000 manual

Living Heat

Living Heat SmartLife CT1000 manual

Aprilaire 8710 owner's manual

Aprilaire

Aprilaire 8710 owner's manual

American Standard Ceratherm T050110 installation instructions

American Standard

American Standard Ceratherm T050110 installation instructions

Namron 70110005 quick start guide

Namron

Namron 70110005 quick start guide

Honeywell DMULTISTAGE T8524C installation instructions

Honeywell

Honeywell DMULTISTAGE T8524C installation instructions

Robertshaw 8625 user manual

Robertshaw

Robertshaw 8625 user manual

Trane Thermostats Product data sheet

Trane

Trane Thermostats Product data sheet

Pro1 Technologies T721i installation guide

Pro1 Technologies

Pro1 Technologies T721i installation guide

Warmup Terra RSW Series quick start guide

Warmup

Warmup Terra RSW Series quick start guide

Honeywell RF CM61NG manual

Honeywell

Honeywell RF CM61NG manual

Pro1 Technologies T601-2 installation manual

Pro1 Technologies

Pro1 Technologies T601-2 installation manual

Honeywell ST772 User instructions

Honeywell

Honeywell ST772 User instructions

Elsner Cala Touch KNX CH Series manual

Elsner

Elsner Cala Touch KNX CH Series manual

Orbis ORUS RF user manual

Orbis

Orbis ORUS RF user manual

Johnson Controls T9580 Owner's manual and installation instructions

Johnson Controls

Johnson Controls T9580 Owner's manual and installation instructions

Honeywell INNCOM e528 Series installation guide

Honeywell

Honeywell INNCOM e528 Series installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.