193⁄4"
(502 mm)
133⁄4"
(349 mm)
3⁄4" NPT
Coupling for
Temperature/Pressure
Relief Valve
26" (660 mm)
203⁄4" (527 mm)
INLET
REAR VIEW
OUTLET
SIDE VIEW
Electical connection
from side or below 3⁄4" NPT Nipple
21⁄4
"
(6 cm)
31⁄2"
(89 mm)
3⁄4"
(19 mm)
77⁄8"
(200 mm)
13" (330 mm)
61⁄2" (165 mm)
21⁄4"
(57 mm)
6" (152 mm)
OPTIONS (NOT FOR RETROFIT)
❑All Stainless Steel Body and Base
❑Slide Brackets (In lieu of Standard 6" (152 mm) Legs)
❑Adjustable Stainless Steel Legs 6" to 7" (152 to 178 mm)
❑Brass Pressure Reducing Valve with Bypass
ITEM#
PRODUCT SPECS
Electric Booster Water Heater
The Electric Booster Water Heater to supply the final 180°F
(82°C) rinse for the dishwasher shall be a Compact Model ....as
manufactured for commercial use by the Hatco Corporation,
Milwaukee, WI 53234 U.S.A.
The booster shall have the capacity to heat ....gph (lph) from
120°F to 180°F (49°C to 82°C) and it shall be rated at ....kW,
....volts, ....phase. The tank shall be designed for a working
pressure of 150 psi (1034 kPa) and hydrostatically tested at
300 psi (2069 kPa) with a Hatco Castone®lining.
The heater shall be complete with all internal plumbing, including
3/4" NPT pipe and fittings for inlet and outlet. All controls shall be
built-in, including contactors and prewired in accordance with
UL #1453 and 422.11 NEL 2002. Proper surface mounting
circuit breaker or fused disconnect switch shall be provided
by electrical contractor.
Electric heating elements shall be metal sheathed, controlled
by an ambient compensating immersion thermostat. The booster
shall be protected with high-temperature limit switch (ECO) and
low-water cut-off.
The heater shall consist of stainless steel front and silver-gray
hammertone body with standard 6" (152 mm) legs (or stainless
steel body, base, and stainless steel adjustable legs).
The heater shall include a temperature/pressure relief valve,
high-temperature pressure reducing valve with bypass, and two
indicating temperature/pressure gauges.
COMPACT ELECTRIC BOOSTER WATER HEATERS
Models C-4, -5, -6, -7, -9, -12, -13, -15, -17, -18, -24, -27, -30, -36, -39, -45, -54, -57
DIMENSIONS
4kW to 18kW: 13"W x 203⁄4"D
(26"†) x 133⁄4"H without legs
(330 x 527 (660 mm†) x 349 mm).
24kW to 57kW: 18"W x 24"D
(301⁄2"†) x 12"H without legs
(457 x 610 (775 mm†) x 305 mm).
†Includes Temperature/Pressure
Relief Valve.
VOLTAGE
208, 240 and 480 volts available.
Export voltages available.
SPECIFICATIONS
1-Phase 3-Phase
Breaker/ Breaker/ Shipping
Model kW Volts Amps Fuse Size Amps Fuse Size Weight
208 115.4 150 67.7 90
C-24 24 240 100 125 57.8 90 142 lbs. (64 kg)
480 – – 29.9 40
208 129.8 175 75 100
C-27 27 240 112.5 150 65 90 142 lbs. (64 kg)
480 – – 32.5 50
208 144 200 83.3 125
C-30 30 240 125 175 72.3 100 142 lbs. (64 kg)
480 – – 36 50
208 173 225 100 125
C-36 36 240 150 200 86.7 125 142 lbs. (64 kg)
480 ––
43.3 60
208 187.5 250 108 150
C-39 39 240 163.5 225 94 125 142 lbs. (64 kg)
480 – – 47 60
208 – – 125 175
C-45•45 240 188 250 108 150 142 lbs. (64 kg)
480 – – 54 70
208 – – 150 200
C-54•• 54 240 – – 130 175 142 lbs. (64 kg)
480 – – 65 90
208 – – 158.4 225
C-57•• 57 240 – – 137.3 200 142 lbs. (64 kg)
480 – – 68.6 90
Models 4-18 kW
18"
(457 mm)
12"
(305 mm)
3⁄4" NPT
Coupling for
Temperature/Pressure
Relief Valve
301/2" (775 mm)
24" (610 mm)
INLET
REAR VIEW
OUTLET
SIDE VIEW
Electical connection
from side or below
3⁄4" NPT Nipple
21⁄4
"
(6 cm)
31⁄4
"
(8 cm)
2"
(51 mm)
77⁄8"
(200 mm)
18" (457 mm)
6"
(152 mm)
6" (152 mm)
21/4"
(57 mm)
31/4"
(83 mm)
Models 24-57 kW
❑Floor Mounting Hardware
❑Security Package
ACCESSORIES
❑Blended Phosphate Water Treatment System
❑Shock Absorber – To Reduce Water Hammer
1-Phase 3-Phase
Breaker/ Breaker/ Shipping
Model kW Volts Amps Fuse Size Amps Fuse Size Weight
208 19 30 – –
C-4 4 240 17 30 – – 105 lbs. (48 kg)
480 8 15 – –
208 24 30 – –
C-5 5 240 21 30 – – 105 lbs. (48 kg)
480 10 15 – –
208 29 40 25* 40
C-6* 6 240 25 40 22* 30 118 lbs. (54 kg)
480 – – 11* 15
208 34 50 29* 40
C-7* 7 240 29 40 25* 40 118 lbs. (54 kg)
480 – – 13* 20
208 43 60 38* 50
C-9* 9 240 38 50 33* 50 118 lbs. (54 kg)
480 – – 16* 20
208 58 90 33 50
C-12 12 240 50 70 29 40 120 lbs. (54 kg)
480 – – 14.5 20
208 65 90 38 50
C-13 13.5 240 56.3 90 33 50 120 lbs. (54 kg)
480 – – 16.3 30
208 72 90 41.7 60
C-15 15 240 62.5 90 36.1 50 120 lbs. (54 kg)
480 – –18.1 30
C-17‡17.2 208 – – 47.9 60 120 lbs. (54 kg)
208 86.5 125 – –
C-18§18 240 75 100 43.4 60 120 lbs. (54 kg)
480 –– 21.7 30
* Only 6, 7, & 9kW Models, 208 and 240 volts only, can be field converted
to single phase (units are shipped 3-phase open delta). Larger branch
circuit required than for balanced 3-phase of equal kW. (Balanced 3-phase
available, consult factory.)
‡17.2kW models available in 208V 3-phase only.
§18kW models not available in 208V 3-phase.
•Not available in 208V single phase.
•• Not available in 208V or 240V single phase.
HATCO CORPORATION P.O. Box 340500 Milwaukee, WI 53234-0500 U.S.A. • (800) 558-0607 • (414) 671-6350
Fax
(800)
543-7521
•
Int’l.
Fax
(414)
671-3976
•
www
.hatcocorp.com
•
E-mail:
[email protected]Form No. C-1006(S) Printed in U.S.A.