Haws H1117LN.8 Guide

10/21 Model H1117LN.8 Page 1 of 10
1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424
No. 0510001192 (3)
Model H1117LN.8
Water Cooler
INSTALLATION, OPERATION
&
MAINTENANCE INSTRUCTIONS
LIMITED WARRANTY
HAWS warrants that all of its products are guaranteed against defective material or poor workmanship for
a period of one year from the date of shipment. The foregoing notwithstanding, HAWS warrants certain
specific products or components thereof for an adjusted period. A list of these excepted products and
components and a description of their respective warranty terms may be found here:
www.hawsco.com/warranty. HAWS’ liability under this warranty shall be discharged by furnishing without
charge F.O.B. HAWS factory any goods, or part thereof, which shall appear to the Company upon
inspection to be of defective material or not of first-class workmanship, provided that a claim is made in
writing to Company within a reasonable period after receipt of the product. Where claims for defects are
made, the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWSshall
not be liable for the cost of repairs, alterations or replacements, or the labor required to implement them, or
for any expense connected therewith made by the owner or owner’s agents, except upon written authority
from HAWS. HAWS shall not be liable for any damages caused by defective materials or poor
workmanship, except for replacements, as provided above. Buyer agrees that HAWS has made no other
warranties either express or implied in addition to those above stated, except that of title with respect to
any of the products or equipment sold hereunder and that HAWS shall not be liable for general, special,
incidental, or consequential damages claimed to arise under the contract of sale.
Equipment manufactured by HAWS is warranted to function if installation and maintenance instructions
provided are adhered to. The units also must be used for the purpose for which they were intended. Any
HAWS emergency equipment is intended to supplement first-aid treatment. Due to widely varying
conditions, HAWS cannot guarantee that the use of this emergency equipment will prevent serious injury
or the aggravation of existing or prior injuries.
EXCEPT AS EXPRESSLY STATED HEREIN, HAWS HEREBY DISCLAIMS ALL WARRANTIES,
WHETHER EXPRESS OR IMPLIED, ARISING BY LAW OR OTHERWISE, INCLUDING WITHOUT
LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. THIS WARRANTY MAY NOT BE MODIFIED OR EXTENDED WITHOUT THE
WRITTEN CONSENT OF HAWS. REMEDIES AND REPLACEMENTS STATED HEREIN ARE
EXCLUSIVE. IN NO EVENT SHALL HAWS BE LIABLE FOR ANY SPECIAL, PUNITIVE,
CONSEQUENTIAL OR INCIDENTAL DAMAGES TO ANY PERSON INCLUDING BUT NOT LIMITED
TO DAMAGES FOR LOSS OF USE OR PROFITS, SUBSTITUTE PRODUCTS OR COSTS, PROPERTY
DAMAGE, OR OTHER MONETARY LOSS.
CAUTION! Prior to making any electrical connections, verify with a voltmeter that power from the
service panel is off.
NOTE TO INSTALLER: Please leave this information with the Maintenance Department.
Haws electric water coolers are not designed or recommended for outdoor or corrosive
environments such as enclosed chlorinated pool areas.
Consideration must be made at the time of installation to adhere to state and/or local codes and
environmental/atmospheric conditions such as, but not limited to, dust, corrosion, freezing etc.
These conditions will void the warranty.

10/21 Model H1117LN.8 Page 2 of 10
RECOMMENDED TOOLS: Hack saw, pipe joint sealant, screwdriver, level, 12" adjustable
wrench, 10" pipe wrench, 5/64“ hex key wrench, 9/16”, 1/2", 7/16” socket wrench or open end
wrench.
LOCATION OF UNIT: The Model H1117LN.8 Cooler is a wheelchair accessible drinking
facility. The height dimensions shown, meet current ADA requirements. When installing this
unit, local, state or federal codes should be adhered to. If height other than shown is required,
then dimensions must be adjusted accordingly.
SUPPLY LINE: The minimum recommended line size is 1/2“IPS with 30-90 psi (2-6 ATM)
flowing pressure. Where sediment or mineral content is a problem, an inlet filter is
recommended.
PLUMBING CONNECTIONS: Inlet is 3/8” O.D. push-in type fitting. Waste outlet is female
1-1/4” IPS.
ELECTRICAL CONNECTIONS (Chiller): 115VAC, 60HZ, 4.7 AMPS. Chiller wired direct to
incoming line, by others. ELECTRICAL CONNECTIONS (When equipped with optional
Hands-Off Bottle Filler model 1920HO): Bottle Filler may be mounted on external wall of
building provided transformer shall be mounted inside the wall and protected from
water per NEC/CEC and local code.
Sensor: 1920HO with 1RKHO.H: 100-277VAC x 9VDC, 50-60Hz, 5 Watts
MAINTENANCE: Periodically clean the strainer (Located inside push button valves on model
H1117LN.8 or 1920 if also installed). Refer to 5874 Series Valve Manual for more information.
Also, clean supply line Y-strainer on model 1920HO (when equipped with this optional
model).
PARTS LIST
MODEL PACKAGE
QUANTITY
ITEMS INCLUDED
MTGFR.LG
1
Mounting Frame (Required –Sold
Separately)
3
#10 Sheet Metal Screws
HCR8
1
Chiller (Required –Sold Separately)
H1117LN.8
1
Bowl Assembly
1
Package supply tubing and fittings
1
Grille
2
Trap 1-1/4” IPS
1
Package of two each grille attachment
clips, clip nuts, #10 sheet metal screws
and 6-32 screws
8
5/16 -18 retainer nuts
8
5/16 –18 x 1 hex head screws
SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS
MODEL PLEASE CALL:
TECHNICAL SUPPORT: 1-800-766-5612
FOR CUSTOMER SERVICE: 1-888-640-4297

10/21 Model H1117LN.8 Page 3 of 10
INSTALLATION PROCEDURE
GENERAL NOTES:
The Model H1117LN.8 Water Cooler assembly requires installation of the mounting frame as
described in Steps 1 - 2, then mounting the fountain bowl assembly as described in Steps 3 - 6,
and finally completing chiller water and electrical connections and starting chiller per Steps 7 -
11. First check that all required parts are received.
Grounding may cause electrical feedback into the electric drinking fountain causing an
electrolysis, which creates a metallic taste or an increase in the metal content of the
water. This condition can be avoided by using dielectric couplings in the assembly. The
waste line, which is supplied by the installer, should also have a dielectric (plastic)
coupling to completely isolate the assembly from the building plumbing system.
NOTES:
1. For all plastic push-in type fitting connections, only connect NSF-61 copper or
plastic tubing. Stainless steel or glass tubing is not recommended. The
following assembly instructions must be followed to ensure a watertight
connection:
a. Cut tubing square and clean.
b. Mark from end of tube the length of insertion (See table below).
c. Push tube into the fitting until it bottoms out.
d. To remove, depress collet and pull tubing out.
Tube Sizes
O.D.
Tolerance
Insertion Depth
1/4”
±.005”
11/16”
3/8”
±.005”
3/4”
2. If installing this unit with optional 1920HO (Hands-Off Model) or 1920:
a. Refer to the 1920 Series manual (supplied with model 1920HO or 1920) for
detailed installation & operation instructions.
b. It is recommended to use Model 6700 Mounting Plate (not supplied) with
Model BP32 Back Panel (standard Hi-Lo configuration - not supplied).
c. Reference page 10 of this document for 1920HO sensor or 1920 push button
height (Mounting hardware not supplied with Bottle Filler Water Dispenser).
d. Adjust nozzle flow rate using pressure regulator mounted inside bracket
(1920HO) or front adjust screw located on push button valve (1920).
e. Refer to the 1RKHO.H manual for Transformer and Sensor Setup
instructions (supplied with model 1920HO).
STEP 1: Provide wall opening as detailed in Installation Drawing. Frame must be positioned
such that frame flanges overlap and butt against finished wall surface. Mounting
holes are provided for #6 sheet metal screws. After frame is positioned in wall, swing
chiller support tray into position (See Installation Drawing), align tray holes with holes
in frame and fasten with #10 sheet metal screws. Mounted frame must support 50-
pound chiller in addition to fountain weight and user generated forces.

10/21 Model H1117LN.8 Page 4 of 10
INSTALLATION PROCEDURE...
STEP 2: Install waste, supply and electrical lines in locations shown in Installation Drawing.
Waste and supply lines may be installed for either rear or side entry. Verify proper
waste, supply, electrical and frame locations. Use level to verify horizontal and
vertical frame mounting to insure proper bowl drainage.
STEP 3: Installation Drawing shows fountain bowls, back panel and grille locations. Unpack
bowls and remove bottom plates using 5/64” hex allen wrench. Install back panel on
frame with narrower edge to bottom. Position nut retainers into mounting frame and
use two 5/16-18x1 hex head screws partially started in outside holes to support
panel. Install bowl/bracket assembly onto panel using eight 5/16-18x1 hex head
screws hand tightened. See sheet 2 of Installation Drawing for appropriate bowl
mounting pattern to use for this model.
STEP 4: Remove 1-1/4” IPS outlet elbow from traps as supplied. Install elbow inside frame
onto waste stub-outs.
STEP 5: Assemble waste trap onto bowl strainer using seal washer provided and tighten nut
hand tight.
STEP 6: See Figure 1 for detail section view of side screw grille attachment. Unpack grille and
insert upper lip behind bottom of back panel, align sides and hold up flush to bottom
of back panel. Hold grille against wall and mark centers of grille side slots on wall.
Masking tape may be used to prevent finished wall damage from mark. Install the “s”
clips in mounting frame using #10 sheet metal screws into pre-drilled holes on lower
end of each side of frame. Tighten #10 screw while holding “s” clips centered on wall
marks. Check grille fit by installing grille and partially tightening #6-23 socket head
screws through side of grille. Ensure proper panel and grille alignment, then tighten
eight 5/16-18x1 hex head screws.
STEP 7: Unpack and remove chiller from carton. Remove front panel screws and panel. Do
not remove insulating putty and foam from copper tubes or Styrofoam insulation from
evaporator coil. Remove any inner packing, which may be around compressor. If
applicable, remove junction box cover and electrical knock out on lower right side of
housing. Install fittings (supplied) on chiller inlet and outlet tubes (see Installation
Drawing).
STEP 8: Thoroughly flush supply line to remove all foreign matter. Connect 1/2" IPS supply
screwdriver stop to stub-out in wall. Place chiller on chiller support tray against right
hand side, fully to rear, with condenser (open panel) side facing to front. Install
supply 3/8” O.D. tubing (not supplied) between screwdriver stop and chiller inlet. (Cut
tubing to proper length and follow general notes for proper connection procedures for
push-in type fittings). Tubing insulation is not normally required on inlet side of chiller.
Install insulated tube between fountain and solenoid valve outlet. Cut tubes as
required and connect to chiller outlet compression tee assembly. Open screwdriver
stop wide open while checking for leaks at all connections. Push fountain operator
to fill chiller and remove air from tubing.

10/21 Model H1117LN.8 Page 5 of 10
INSTALLATION PROCEDURE...
STEP 9: Adjust bubbler stream height using small flathead screwdriver inserted through a
hole in the center of the push button for increased flow turn clockwise and for
decreased flow turn counterclockwise. If flow problems arise, see troubleshooting
guide for additional instructions to correct problem. Bubbler stream may lower during
short break-in period. Set initial stream height a little high to minimize or eliminate the
need for break-in period readjustment.
STEP 10: Verify that electrical power is off and power supply voltage, phase and cycle match
specifications printed on chiller label. In accordance with local codes, wire directly to
incoming lines at internal chiller junction box. Verify that all inner packing is removed
and hand rotate fan blade to verify free rotation. Reattach chiller front panel. Turn
power on and verify that chiller cycles off after water reaches proper temperature.
Finally check for leaks.
STEP 11: Install grille and tighten outer side screws. Verify there is chilled water out of bubbler.
MAINTENANCE
STEP 1: Periodically clean the strainer (Located inside push button valves on model
H1117LN.8 or 1920 if also installed). Refer to 5874 Series Valve Manual for more
information. Also, clean supply line Y-strainer on model 1920HO (when equipped
with this optional model).
STEP 2: The condenser fins on chiller should be periodically cleaned with brush, air hose or
vacuum cleaner. Care should be taken not to bend or deform the condenser fins.
STEP 3: The chiller temperature control is factory set for 50ºF water under normal
conditions. For colder water, adjust control clockwise. For warmer water, turn
counterclockwise. Remove front chiller panel for access to temperature control. After
adjustment allow unit to cycle off before checking outlet water temperature.
FIGURE 1

10/21 Model H1117LN.8 Page 6 of 10
5874 SERIES VALVE TROUBLESHOOTING (MODEL H1117LN.8 AND WHEN
EQUIPPED WITH OPTIONAL MODEL 1920)
PROBLEM
REPAIR CHECKLIST
1.
Insufficient bubbler or nozzle
flow.
1a.
Check that inlet screwdriver stop valve is in wide-
open position. Turn counterclockwise or clockwise.
Direction depends on style of shut-off valve.
b.
Verify minimum 30 psi flowing supply pressure.
c.
Clean strainer. See 5874 Series Valve Manual.
d.
e.
Adjust valve to increase flow. Use front adjust
screw or see 5874 Series Valve Manual.
Make sure bottle filler nozzle is free of debris.
2.
Water too warm or cold.
2a.
Adjust chiller temperature control, clockwise for
colder water.
SENSOR/SOLENOID TROUBLESHOOTING (WHEN EQUIPPED WITH HANDS-
OFF MODEL 1920HO. REFER TO 1RKHO.H MANUAL FOR EXPANDED LIST)
PROBLEM
REPAIR CHECKLIST
1.
Insufficient nozzle flow.
1a.
Check that inlet screwdriver stop valve is wide
open. Turn counterclockwise or clockwise.
Direction depends on style of shut-off valve.
b.
Verify minimum 30 psi flowing supply pressure.
c.
Clean supply line Y-strainer.
d.
Adjust pressure regulator valve to increase flow
(Loosen locknut and rotate knob clockwise to
increase flow and tighten locknut).
e.
Make sure bottle filler nozzle is free of debris.
2.
Nozzle does not activate.
2a.
b.
c.
d.
Check wiring harness. Replace if necessary.
Check solenoid valve. Replace if necessary.
Check sensor. Replace if necessary.
Check transformer for 9V output at terminals;
replace if necessary.
For more information about Haws products, see our website: www.hawsco.com
© 2021 Haws®Corporation –All Rights Reserved
HAWS® and other trademarks usedin these materials are the exclusive property of Haws Corporation.

SPANNER WRENCH
REMOTE CHILLER
MOUNTING FRAME
GRILLE 1117L P/N
BACK PANEL 1117LN
KEY HEX F/PINNED HEX
A
7
3
5
9
10
11
12
8
4
2
6
APPROVED
DRAWN
PART NUMBER
SCALE: SHEET OF
REVISION
DRAWING TYPE: SIZE: A
BYECN NO.
PAGE
DATE
DATE
ECN:
REVISED PER
CHKD
Haws Corporation - All Rights Reserved
HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
C
R
MODEL(S)
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (775) 359-7424
E-MAIL: [email protected]
WEBSITE: WWW.HAWSCO.COM
ITEM DESCRIPTION
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
WHEN ORDERING PARTS PLEASE SPECIFY MODEL NUMBER.
PART NO.
DP
03/23/21
3
0510001192
H1117LN.8
N/A
11
FV
10/11/21
.5671
BJM
7 OF 10
PARTS BREAKDOWN
5745
2021
FV
0006983506
HCR8
MTGFR.LG
0002626651
0410000218
0002981127
PARTS BREAKDOWN
1
REF
3
ROTATED 90° INTO VIEW
DETAIL A
REMOVE INSERT
WITH 5/16 HEX SOCKET
(NOT SUPPLIED)
1
NOTES:
1 ENSURE TUBE IS DISCONNECTED FROM PUSH BUTTON
VALVE BODY PRIOR TO REMOVAL. APPLY ONE DROP OF
LOCTITE 222MS TO NOZZLE THREADS PRIOR TO FASTENING
BACK ONTO BUBBLER HEAD. RE-ATTACH TUBE TO VALVE.
2 ITEMS 13 THRU 17 ARE OPTIONAL AND CAN BE CONFIGURED
TO ADD EITHER A HANDS-OFF (1920HO) OR PUSH BUTTON
(1920) BOTTLE FILLER, MOUNTED ON R.H. SIDE OF BACK
PANEL (BP32) OR L.H. SIDE (REVERSED) OF BACK PANEL
(BP32R) ON DUAL FOUNTAIN MODEL 1117LN.
13 2
REF
14 15
22
162
17
2
BP32 (SHOWN)
BP32R (NOT SHOWN)
**
4
5
7
8
STRAINER, WASTE ASSY
BUBBLER HEAD ASSY, PCP 5703M
6462
TRAP 0005982900
PLATE BOTTOM PBM1107
1
2
3
PUSH BUTTON ASSY
VALVE REPAIR KIT VRK5874
PBA6
6
9
10
12
13
BOTTLE FILLER, HANDS-OFF
PLATE MOUNTING 6700
1920HO
BOTTLE FILLER 1920
BACK PANEL FOR 1920 OVER DUAL FOUNTAIN BP32
BACK PANEL BF 32 REVERSED BP32R
11
2
14
15
16
17
** REQUIRED - SOLD SEPARATELY
**

ADULT WHEELCHAIR
WASTE
ADULT
STANDING
WASTE
A
12 12
DETAIL A
(NOT SUPPLIED)
BACK
PANEL
1-1/4" IPS WASTE
(NOT SUPPLIED)
1-1/4" IPS TRAP
(SUPPLIED)
2X
MTGFR.LG
FRAME
FLANGE
WALL FACE
4
5
5
5
5
5
2-7/8"
[73mm]
5
1/2" IPS SUPPLY
(NOT SUPPLIED)
GRILLE
ELECTRICAL ACCESS
WALL SURFACE
ADULT
STANDING
BUBBLER
ADULT
STANDING
FOUNTAIN
ADULT
WHEELCHAIR
BUBBLER
ADULT
WHEELCHAIR
FOUNTAIN
FLOOR LINE
(4)
[10 2mm]
MOUNTING
FRAME
WIDTH
STUD
SUPPLY STOP AND
3/8" OD TUBING
12
[305mm]
CLEARANCE
41
4
[108mm]
37-5/8
[956mm]
[791mm]
31-1/8
*
2
[50mm]
*
*
*
*
*
*
*
*
*
3
3
3
CHILLER SUPPORT TRAY 10
HCR8
CHILLER
ROUGH-IN
ROUGH-IN
*
NOTES:
1. HOLD ROUGH-IN DIMENSIONS ± 1/8" (3.2mm)
2. WHEN INSTALLING THIS UNIT, LOCAL, STATE, OR FEDERAL CODES SHOULD BE
ADHERED TO. FOR INSTALLATION HEIGHTS OTHER THAN SHOWN, DIMENSIONS
MARKED ( * ) MUST BE ADJUSTED ACCORDINGLY.
3 REFER TO MTGFR.LG INSTALLATION DRAWING FOR FRAME ROUGH-IN DIMENSIONS.
4 REFER TO 5874 SERIES OPERATION AND MAINTENANCE MANUAL FOR
PUSH BUTTON AND VALVE INSTALLATION/MAINTENANCE INSTRUCTIONS.
5 ROUGH-IN DIMENSIONS FOR FOUNTAIN HEIGHTS:
ADULT WHEELCHAIR HEIGHT: SEE SHEET 2 FIG 2
WASTE: 29-1/4" (743mm)
FOUNTAIN: 27" (686mm)
BUBBLER: 32-7/8" (832mm)
ADULT STANDING HEIGHT: SEE SHEET 2 FIG 3
WASTE: 34-3/4" (883mm)
FOUNTAIN: 32-1/2" (826mm)
BUBBLER: 39-3/8" (972mm)
NOTES CONTINUED ON SHEET 2 OF 3
IMPORTANT: MOUNTING
FRAME MUST BE INSTALLED
SO THAT LIP OF FRAME SITS
AGAINST FINISHED WALL FACE.
3/8" OD TUBING,
INSULATION, TEE
& FITTING
(SUPPLIED)
INLINE STRAINER,
1/4" OD TUBE X
3/8" OD TUBE
INLET (SUPPLIED)
10 3
4
[272mm]
25
[635mm]
SUPPLY
MOUNTING FRAME
8
[203mm]
8
[203mm]
38-3/4
[985mm]
(1 1
2)
[38mm]
APPROVED:
DRAWN:
PART NUMBER
SCALE: SHEET OF
REVISION
DRAWING TYPE: SIZE: A
BY:ECN NO.
PAGE
DATE:
DATE:
ECN:
REVISED PER
CHK'D.:
PAGE
Haws Corporation - All Rights Reserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
CR
MODEL(S)
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (775) 359-7424
E-MAIL: [email protected]
WEBSITE: WWW.HAWSCO.COM
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
DP
03/24/21
3
0510001192.D
H1117LN.8
N/A
13
FV
10/11/21
5671
BJM
8 OF 10
INSTALLATION
5745
8 OF 10
2021
FV
[305mm] [305mm]
1
2
[13mm]
191
4
[489mm]
32
[813mm]
REQUIRED -
SOLD SEPARATELY
11
SEE SHEET 3 FOR OPTIONAL 1920/1920HO
BOTTLE FILLER WATER DISPENSER, SHOWN
INSTALLED OVER MODEL H1117LN.8
NOTE: FOR FILTERED WATER,
OTHERS TO SUPPLY FILTER
PRIOR TO THIS CONNECTION
AND MOUNT TO SIDE OF
MOUNTING FRAME IN THIS
LOCATION.

ADULT STANDING / ADULT WHEELCHAIR
NOTES (CONTINUED FROM SHEET 1):
6 USE SHADED HOLES TO MOUNT BOWLS AT INDICATED POSITIONS.
7. REFER TO SHEET 1 OF 3 NOTE 5, FOR INSTALLED FOUNTAIN DIMENSIONS.
SCREW
8
9
INDICATED (SHOWN BY DARKENED HOLES). USE THE UPPER OUTERMOST
INSERT 5/16"-18 PANEL NUT RETAINERS FROM OPPOSITE SIDE AT LOCATONS
9
6 (TYPICAL)
BOWL MOUNTING LOCATIONS
8
TO INSERT OR REMOVE NUT RETAINERS: SNAP NUT RETAINERS INTO
AND THEN SQUEEZE CLIPS ON NUT RETAINER TO POP OUT.
HOLES ON THE LEFT AND LOWER OUTERMOST HOLES ON THE RIGHT.
BOWL MOUNTING DETAIL
ALIGN HOLES IN CHILLER SUPPORT TRAY WITH HOLES IN FRAME
AND FASTEN WITH #10 SHEETMETAL SCREWS (SEE SHEET 1).
10
APPROVED:
DRAWN:
PART NUMBER
SCALE: SHEET OF
REVISION
DRAWING TYPE: SIZE: A
BY:ECN NO.
PAGE
DATE:
DATE:
ECN:
REVISED PER
CHK'D.:
PAGE
Haws Corporation - All Rights Reserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
CR
MODEL(S)
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (775) 359-7424
E-MAIL: [email protected]
WEBSITE: WWW.HAWSCO.COM
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
DP
03/24/21
3
0510001192.D
H1117LN.8
N/A
23
FV
10/11/21
5671
BJM
9 OF 10
INSTALLATION
5745
9 OF 10
2021
FV
NOTE: BACK PANEL MUST BE INSTALLED WITH
THESE CUT-OUTS ORIENTED AS SHOWN.
9
INDICATED LOCATIONS. IF REMOVAL IS REQUIRED, FIRST REMOVE SCREWS
MAXIMUM ADJUSTABLE RANGE IS 15° FROM PARALLEL TO BACK OF WALL.11

APPROVED:
DRAWN:
PART NUMBER
SCALE: SHEET OF
REVISION
DRAWING TYPE: SIZE: A
BY:ECN NO.
PAGE
DATE:
DATE:
ECN:
REVISED PER
CHK'D.:
PAGE
Haws Corporation - All Rights Reserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
CR
MODEL(S)
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (775) 359-7424
E-MAIL: [email protected]
WEBSITE: WWW.HAWSCO.COM
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
FV
10/09/21
3
0510001192.D
H1117LN.8
N/A
33
FV
10/11/21
5745
BJM
10 of 10
INSTALLATION
5745
10 of 10
2021
FV
(27")
(686mm)
(46")
(1168mm)
SENSOR/BUTTON
HEIGHT
FOR ADA
COMPLIANCE
6-3/4"
171mm
5-5/8"
143mm
1920HO (W/HANDS-OFF SENSOR - SHOWN)
1920 (W/PUSH BUTTON VALVE - NOT SHOWN)
6700 (OPTIONAL)
FINISH WALL)
BP32 (OPTIONAL)
(IF FOUNTAIN
HIGH/LOW SIDES
ARE REVERSED
USE BP32R)
MOUNTING PLATE
(BEHIND
EXISTING PUSH BUTTON
ASSEMBLY SHOWN, CAN
BE CONVERTED TO HANDS
OFF STYLE, USING RETRO-
FIT KIT MODEL 1RKHO.H OR
2RKHO.H DEPENDING ON
CUSTOMER REQUIREMENTS.
**
OPTIONAL 1920/1920HO BOTTLE FILLER WATER DISPENSER
(1920HO SHOWN) INSTALLED OVER H1117LN.8
(SEE 1920 SERIES OPERATION AND MAINTENANCE MANUAL FOR COMPLETE DETAILS)
SEE SHEET 1 FOR H1117LN.8 ROUGH-IN DIMENSIONS
SENSOR, TRANSFORMER,
SOLENOID VALVE, PRESSURE
REGULATOR VALVE, TEE,
3/8" O.D. SUPPLY TUBING ARE
SUPPLIED WITH OPTIONAL
MODEL 1920HO. Y-STRAINER
IS ALSO SUPPLIED AND CAN
BE USED IF REQUIRED (NOT
SHOWN).
SENSOR
(HANDS-OFF)
CONNECT 3/8" O.D. SUPPLY
TUBING AND TEE
(SUPPLIED) TO HCR8
CHILLER AS SHOWN.
**
Table of contents
Other Haws Water Dispenser manuals
Popular Water Dispenser manuals by other brands

clage
clage ZIP HYDROTAP G4 BC 100/75 Operating and installation instructions

BWT
BWT AQA drink 1 installation manual

Stalgast
Stalgast DVA LT Series Instruction leaflet

PUR
PUR PPT711W owner's manual

Whirlpool
Whirlpool WHES18 Description, Installation and Operation Manual

US Water Systems
US Water Systems Ultimate Dual Superfilter FSF-250 owner's manual