www.heliosps.com Specifications are subject to change without notice. No liability accepted for errors or omissions. 7
OPTIONS
Temperature
compensated charg-
ing
Alarms:
Alarm Relay Contacts
Internal output diode
(SR250LP..)
Earth Fault Alarm
-4mV / °C / cell , sensor lead length 1.7m
Order Code: +TEMPCO
Mains fail (or PSU in standby mode)
DC low (Battery low or PSU low) - set at
92% of nominal voltage.
Special version available: Battery low
alarm operates when mains power is
on, order code: SFMCT-OA v1.1
DC high
C - NO - NC full changeover rated
1A /50V DC, 32VAC
Incl. alarms & output diode for N+1 redun-
dancy, internal diode not available for
12V models.
Using an external alarm card (see sepa-
rate data sheet)
MODELS
Power Supply Battery Charger
Adjustable
range (V)
Output
Volts
(factory de-
fault)
Output
Current (A)
(continuous)
Output
Volts*
(Charging)
Output
Current (A)
(Charging)
SR250A7.5 7.5 20 6.9 20 (140W) 6.8-8
SR250A12 13.8 18.1 13.8 18.1 11-14
SR250A24 24 10.4 27.6 9.0 22-28
SR250A30 30 8.3 34.5 7.2 28-36
SR250A36 36 6.9 41.4 6.0 34-43
SR250A48 48 5.2 55.2 4.5 45-57
SR250A60 60 4.1 69.0 3.6 54-69
STANDARD MODEL TABLE
* Please specify on ordering if
the unit is to be used for float
charging (except for 12V model
which is set at 13.8V by default).
MODEL IDENTIFICATION CODES
SR250L12 T F S L-485
L = 230V AC + switch Blank = 230V AC no switch
U = 110V AC + switch G = 110V AC no switch
H = 110V DC + switch J = 110V DC no switch
Input voltage and front
panel standby switch
S = Stud X = Plug in /screw terminal block
F = Fan Blank = No fan
T = Yes Blank = No
12, 24, 30, 36, 48, 60
Output DC Connector type:
Fan cooled:
Temperature Compensation
DC output: Nominal voltage
Function
Optional communication
port
Power 250W
250 Watt
AC/DC Stand Alone Power Supply/Float Charger
485 = RS485 232 = RS232
LAN + = Ethernet (SNMP) LAN = Ethernet (ASCII)
Communication port
Protocols
Digital V/I meter
19”rack mount
Wall Mount Enclosure
Choice of RS485, RS232, Ethernet
Note: Requires external battery for commu-
nications to continue working when there is
a loss of input power.
SNMP v1
Modbus (external converter)
Serial: +PROTOCONMB
TCP & HTTP: +PROTOCONMB-OE
May be fitted with SR250 in 19” rack,
add: SR-METER or SR-METERV2/SHUNT
Single charger add: SR-RM2U
Dual charger (front removable) add:
SR-RM2U-DUALV2
Charger may be fitted into enclosure with
MCBs and terminals. Code: SEC-SR
OPTIONS (cont.)
A = Basic version
D = with mains fail and dc low alarms
L = with mains fail, dc low, dc high alarms
P = with output diode (24V & above) and “D” alarms
LP = with output diode (24V & above) and “L” alarms