Assembly Instructions2HermanMiller 1BNX5K rev J
Before connecting the power cords to the workstation,
follow the instructions below to properly initialize the Columns with the
Control Box.
NOTE: The workstation will not RISE until the Initialization procedure is
completed.
• Connect the Column Motors to the Control Box.
• Connect the Hand Switch to the Control Box.
• Connect the main Power Cord to the Control Box.
• Connect the main Power Cord to the electrical outlet; the Control
Box should make a clicking sound indicating it has been
programmed.
• Press the down button on the Hand Switch until the Columns reach
their lowest position.
• Press the down button on the Hand Switch once again until the
Tabletop moves down slightly and then back up slightly. Listen
carefully if this step is performed correctly the Control Box should
make a clicking sound.
• Aer completing the Initialization procedure, the workstation may
be raised and lowered.
Do Not Overload Desk
To prevent table from tipping or collapsing, make sure the desk frame is
not overloaded by the weight of table top and objects on table. Evenly
distribute load; excess loads near edges can reduce stability and lead
to tip over.
• Do not exceed maximum load (including weight of desktop) of
lb. (Kg) for two-leg conguration.
• Do not exceed edge load of lb. when positioning monitors or
mounting accessories.
• Do not sit or stand on table
Use Care When Moving Desk
• Clear objects and equipment from table before rolling to reduce
the risk of tipping over.
• Adjust the desk to its lowest height before moving
• To disconnect, then remove plug from outlet
• Do not move a loaded desk
Do Not Open Electrical Components
Keep Table Frame Dry
Do not attempt to service table components. There are no user-
serviceable parts inside the motor control units or table legs. If
your table needs service, contact customer service. Never operate
this furnishing if it has a damaged cord or plug, if it is not working
properly, if it has been dropped or damaged. Return the furnishing to
a service center for examination and repair.
Keep all electrical components away from water and high humidity.
Clean only with a dry or slightly damp cloth. Do not spray cleaning
solutions directly onto table system.
Grounding Instructions
Not valid for most Nevi desks power cord for smart NEO Control box
is not grounded. Only prong . prong cord only used for -Leg
conguration that uses a compact control box. Make sure that the
product is connected to an outlet having the same conguration as the
plug (as shown in Illustration A) that is properly installed and grounded
in accordance with all local codes and ordinances.
Do not modify the plug provided with the product - if it will not t the
outlet, have a proper outlet installed by a qualied electrician.
No adapters are to be used with this product. Keep cord away from
heated surfaces.
Grounding Pin Grounded Outlet
Grounded Outlet Box
WARNING: Risk of Electric Shock, Fire, and Injury. Review the
assembly instructions to conrm that the appropriate critical
components and accessories are being used with the furnishing.
AVERTISSEMENT: Risque d’électrocution, d’incendie et de blessure.
Consultez les instructions d’assemblage pour conrmer que les
composants et accessoires critiques appropriés sont utilisés avec le
meuble.
WARNING: RISK OF INJURY, not to be used in locations where children,
or people with cognitive disabilities are anticipated to be present.
AVERTISSEMENT: RISQUE DE BLESSURE, ne pas utiliser dans des
endroits où des enfants ou des personnes sourant de troubles
cognitifs sont censés être presents.
STOP