manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. HID
  6. •
  7. Card Reader
  8. •
  9. HID Signo 20 User manual

HID Signo 20 User manual

hidglobal.com An ASSA ABLOY Group brand
HID Signo™ Reader
13.56 MHz / 125 kHz / 2.4 GHz Contactless and Keypad Readers
SRD Models: 20, 20K, 40, 40K
ATTENTION
Observe precautions for handling
ELECTROSTATIC SENSITIVE DEVICES
1 Mount the mounting plate
Power the reader. The reader will
beep and the LED will flash.
Test the reader with a credential. The reader
will beep and the LED will flash.
Optional features
Tamper – Enabled by default and activated when the mounting plate is removed. The tamper is
normally closed and changes to open circuit between Tamper 1 and Tamper 2 control lines. Tamper
1 and Tamper 2 control lines are interchangeable. Either of these lines can be connected with the
reader ground line to reduce the number of cable cores required in the reader cable. Tamper 1 and
Tamper 2 are rated 0–12VDC at 100mA.
Hold Input – When asserted, this line either buffers a card (default) or disables a card read until
released, as configured.
PIGTAIL TERMINAL DESCRIPTION
Red 1 +VDC
Black 2 Ground (RTN)
White 3 Wiegand Data 1 / Clock / RS485-A*
Green 4 Wiegand Data 0 / Data / RS485-B*
Orange 5 LED Input (GRN)
Yellow 6 Beeper Input
Blue 7 Hold Input / LED Input (BLUE)*
Brown 8 LED Input (RED)
Violet/White 9 Tamper 2 (RLY2)
Violet 10 Tamper 1 (RLY1)
Bare — Drain (pigtail models only)
*Dependent upon reader configuration.
Note: Wiring the reader incorrectly may permanently damage the reader.
Note: Previous iCLASS®readers had reversed RS-485 wiring (P2-7 & P2-6 - A & B). When
upgrading to a HID Signo reader, ensure proper connections as defined above.
Note: Data 0 and Data 1 wires for Wiegand may be reused for OSDP. However, standard
Wiegand cable may not meet RS485 twisted pair recommendations.
Note: For OSDP cable lengths greater than 200 ft (61 m) or EMF interference, install 120Ω+/- 2Ω
resistor across RS-485 termination ends.
Note: For keypad configuration, with the keypad reader operating as 26 bit emulation, enter the
facility code followed by # within five seconds of power-up. The facility code must be entered as
three digits (i.e., for a facility code of 10 enter 0-1-0-#). If unsuccessful, the reader LED displays
solid red. Power-cycle the reader and retry entering the facility code.
HID Signo readers use facility codes between 1-255, and no default is set. Once a facility code
is entered, the reader LED displays violet, then solid red. Then, power-cycle the reader. If there
are two short beeps after entering a PIN, the reader facility code is not configured. In this case,
power-cycle the reader and retry entering the facility code.
2 Wire the reader
3 Secure the reader to the mounting plate
4 Power and test the reader
www.hidglobal.com/PLT-03704
Scan the QR code or visit the link to see
the multi-language electronic version of
this document.
Lisez le code QR ou suivez le lien pour
consulter la version française de ce
document.
Escanee el código QR o visite el vínculo
para consultar la versión en Español de
este documento.
Scannen Sie den QR-Code oder öffnen Sie
den Link für die deutsche Version dieses
Dokuments.
Faça a leitura do código QR ou acesse
o link da versão em português deste
documento.
Scansiona il codice QR o visita il link della
versione Italiana di questo documento.
Отсканируйте QR-код или пройдите по
ссылке, чтобы получить версию этого
документа на русском языке.
扫描QR码或访问此文档的中文版本的链接。
この文書の日本語版を表示するには、QRコードを
スキャンするか、リンクをクリックします。
QR코드를 스캔하거나 링크를 방문하면 이 문서의
한국어 버전을 볼 수 있습니다.
© 2019 – 2020 HID Global Corporation/ASSA ABLOY AB. All
rights reserved. HID, the HID Brick logo, the Chain Design, HID
Signo, HID Reader Manager, iCLASS, and HID Mobile Access are
trademarks or registered trademarks of HID Global, ASSA ABLOY
AB, or its aliate(s) in the US and other countries and may not be
used without permission. All other trademarks, service marks, and
product or service names are trademarks or registered trademarks
of their respective owners.
INSTALLATION GUIDE
PLT-03703, Rev. A.2
18"
(0.46m)
Pigtail versions Terminal strip versions
CAUTION: Install the reader
on a flat, stable surface. Failure
to do so may compromise
the IP rating and/or tamper
feature. If mounting on
or near metal, a spacer is
recommended for optimal
read performance. Refer to the
Readers and Credentials How
to Order Guide (PLT-02630)
for available options and part
numbers.
CAUTION: Use the supplied
screws to ensure correct fitting
and to avoid damaging the
reader or mounting plate. HID
is not responsible for damage
due to use of unapproved
mounting hardware.
For Imperial (US):
Use supplied flat head/
countersunk 0.138-32 x 0.375"
screws.
For Metric (EU etc):
Use supplied flat head/
countersunk M3.5 x 12mm
screws.
1. Hook the top of the reader on the top of
the mounting plate.
2. Align the bottom of the reader with the
bottom of the mounting plate.
3. Secure the reader to the mounting plate
using the supplied 0.138-32 x 0.375" screw.
Security/anti-tamper screw:
0.138-32 x 0.375" screw (supplied).
Non-security/standard screw:
0.138-32 x 0.375" screws (supplied).
1
23
Supplied parts
HID Signo Reader (1)
Installation Guide (1)
Flat head/countersunk 0.138-20 x 1.5" self–
tapping screws (2) – for installing the reader
directly to a wall (no junction box)
Flat head/countersunk 0.138-32 x 0.375"
machine screws (3) – for Imperial (US)
junction box installation (2) and attaching
the reader to the mounting plate (1)
Flat head/countersunk M3.5 x 12mm machine
screws (2) – for Metric (EU etc) junction box
installation
Flat head/countersunk 0.138-32 x 0.375"
security screw (1) – alternative anti-tamper
screw for attaching the reader to the
mounting plate
5-pin terminal connectors, terminal strip
models only (2)
Recommended parts (not supplied)
Cable, 5-10 conductor (Wiegand or
Clock-and-Data), 4 conductor Twisted Pair
Over-All Shield and UL approved, Belden
3107A or equivalent (OSDP)
Certified LPS DC power supply
Metal or plastic junction box
Security tool HID 04-0001-03 (for
anti-tamper screw)
Drill with various bits for mounting hardware
Mounting hardware
Reader spacer when mounting on or near
metal or metal junction boxes. Refer to the
Reader and Credentials How to Order Guide
(PLT-02630) for available options and part
numbers)
Junction box
hidglobal.com An ASSA ABLOY Group brand
Powering
Trusted Identities
PLT-03703, Rev. A.2
15 Equipment
8T2 9
ACC Control READER
General Signaling
Equipment
E4662 CIDF18000157
Brazil
Condomínio Business Center
Av. Ermano Marchetti, 1435
Galpão A2 - CEP 05038-001
Lapa - São Paulo / SP
Brazil
Phone: +55 11 5514-7100
Asia Pacific
19/F 625 King's Road
North Point, Island East
Hong Kong
Support: 852-3160-9833
Fax: 852-3160-4809
Americas & Corporate
611 Center Ridge Drive
Austin, TX 78758
USA
Support: 866-607-7339
Fax: 949-732-2120
Europe, Middle East & Africa
Phoenix Road
Haverhill, Suolk CB9 7AE
United Kingdom
Support: 44 (0) 1440 711 822
Fax: 44 (0) 1440 714 840
Taiwan
According to “Administrative Regulations on Low Power Radio Waves Radiated Devices” Without
permission granted by the NCC, any company, enterprise, or user is not allowed to change
frequency, enhance transmitting power or alter original characteristic as well as performance to
a approved low power radio-frequency devices. The low power radio-frequency devices shall
not influence aircraft security and interfere legal communications; If found, the user shall cease
operating immediately until no interference is achieved. The said legal communications means
radio communications is operated in compliance with the Telecommunications Act. The low power
radio-frequency devices must be susceptible with the interference from legal communications or
ISM radio wave radiated devices.
Korean KCC
20, 20K, 40, 40K
항목 규격
송신주파수 RFID:13.56MHz
수신주파수 RFID:13.56MHz
출력 RFID:10m에서47.544mv이하
전원 DC12.0V
전파형식 A1D
발진방식 X-tal
변조방식 RFID:ASK,NFC:GFSK
Russia
Дата изготовления указана на маркировке оборудования
Представитель в Российской Федерации
Название ООО «Дофин»
Адрес 140573, РФ, Московская обл., Озерский район, с. Бояркино
Контактное лицо Л.Н. Голубова
Телефон +7 495 223 6008
e-mail [email protected]
Japan MIC
“この装置は総務省の型式指定を受けています。”
(総務省指定番号は第AC-xxxxx号です)
本製品は電波を使用したRFID機器の読み取り・書き込み装置です。
そのため使用する用途・場所によっては、医療機器に影響を与える恐れがあります
Israel
השימוש במכשיר הינו על בסיס ״משני״ ופטור מרשיון הפעלה אלחוטי.
רק ״בפעולת בזק״ לשימוש עצמי של הלקוח בלבד, הלקוח פטור מרשיון הפעלה אלחוטי.
אסור להחליף את האנטנה המקורית של המכשיר, ולא לעשות בו כל שינוי טכני אחר.
Brazil
Compliance Statement
Este produto está homologado pela ANATEL, de acordo com os procedimentos regulamentados
pela Resolução 242/2000, e atende aos requisitos técnicos aplicados. Para maiores informações,
consulte o site da ANATEL - www.anatel.gov.br
This product is homologated at ANATEL according to procedure regulated by Resolution
242/2000, and it complies with the applicable technical requirements. For more information,
consult ANATEL website - www.anatel.gov.br
RF Warning Statement
Per Article 6 of Resolution 506, equipment of restricted radiation must carry the following
statement in a visible location:
Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra
interferência prejudicial, mesmo de estações do mesmo tipo, e não pode causar interferência a
sistemas operando em caráter primário.
This equipment operates in secondary character, meaning it does not have the right of protection
against harmful interference, even against those the same character, and it cannot cause any
interference to systems operating in the primary character.
Singapore Australia and New Zealand
Complies with
IMDA Standards
DB106440 E4662
Specifications
20 20K 40 40K
INPUT VOLTAGE (V DC) 12V DC
CURRENT
STANDBY AVG160 mA 65 mA 65 mA 70 mA
MAX AVG270 mA 75 mA 75 mA 80 mA
PEAK 250 mA 250 mA 250 mA 250 mA
OPERATING
TEMPERATURE -30° F to 150° F (-35° C to 66° C)
CABLE LENGTH Communication Lines
Wiegand = 500 ft - 18 AWG (152 m)
300 ft - 20 AWG (91 m)
RS-485 = Max bus length: 4,000 ft - 24 AWG (1,219 m)
Max length between nodes: 1,640 ft - 24 AWG (500m)
REGULATORY REF
NUMBER 20 20K 40 40K
FREQUENCY BLE: 2.4–2.480 GHz, HF: 13.56 MHz, LF: 125 kHz
FCC IDS JQ6-SIGNO20 JQ6-SIGNO20K JQ6-SIGNO40 JQ6-SIGNO40K
IC IDS 2236B-SIGNO20 2236B-SIGNO20K 2236B-SIGNO40 2236B-SIGNO40K
1 Standby AVG - RMS current draw without a card in the RF field.
2 Maximum AVG - RMS current draw during continuous card reads. Not evaluated by UL.
3 Peak - highest instantaneous current draw during RF communication.
Regulatory
UL
Connect only to a Listed Access Control / Burglary power-limited power supply. These readers are
intended to be used with listed (UL294) control equipment. Suitable for outdoor use.
Only Wiegand, OSDP, and Bluetooth communications have been evaluated by UL.
HID Signo readers are compatible with HID Mobile Access® version 3.0.0 and later using mobile
devices with BLE version 4.2 and later listed at:
https://www.hidglobal.com/mobile-access-compatible-devices.
Install in accordance with NFPA70 (NEC) Local Codes, and authorities having jurisdiction. Follow
all National and Local Codes.
UL 294 Performance Levels
MODEL #
ACCESS
CONTROL
LINE
SECURITY
LEVEL
DESTRUCTIVE
ATTACK
LEVEL
ENDURANCE
LEVEL
STAND-BY
POWER LEVEL CONDITIONS
20 / 20K / 40 / 40K Level I Level I Level IV Level I
FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
CAUTION: Any changes or modifications to this device not explicitly approved by the
manufacturer could void your authority to operate this equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
Canada Radio Certification
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device
must accept any interference, including interference that may cause undesired operation of the
device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio
exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil
ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
CE Marking
HID Global hereby declares that these proximity readers are in compliance with the essential
requirements and other relevant provisions of Directive 2014/53/EU.
Por el presente, HID Global declara que estos lectores de proximidad cumplen con los requisitos
esenciales y otras disposiciones relevantes de la Directiva 2014/53/EU.
HID Global déclare par la présente que ces lecteurs à proximité sont conformes aux exigences
essentielles et aux autres stipulations pertinentes de la Directive 2014/53/EU.
A HID Global, por meio deste, declara que estes leitores de proximidade estão em conformidade
com as exigências essenciais e outras condições da diretiva 2014/53/EU.
HID Global bestätigt hiermit, dass die Leser die wesentlichen Anforderungen und anderen
relevanten Bestimmungen der Richtlinie 2014/53/EU erfüllen.
HID Global dichiara che i lettori di prossimità sono conformi ai requisiti essenziali e ad altre misure
rilevanti come previsto dalla Direttiva europea 2014/53/EU.
Download copies of the Radio Equipment Directive Declaration of Conformity (DoC) at:
http://www.hidglobal.com/certifications

Other manuals for Signo 20

1

This manual suits for next models

3

Other HID Card Reader manuals

HID iCLASS RK40 User manual

HID

HID iCLASS RK40 User manual

HID ProxPoint Manual

HID

HID ProxPoint Manual

HID iCLASS RK40 User manual

HID

HID iCLASS RK40 User manual

HID ProxPoint Plus User manual

HID

HID ProxPoint Plus User manual

HID iCLASS bio500 User manual

HID

HID iCLASS bio500 User manual

HID MaxiProx DFM Reader - 5375 User manual

HID

HID MaxiProx DFM Reader - 5375 User manual

HID Technology Solutions 1060 User manual

HID

HID Technology Solutions 1060 User manual

HID Miniprox User manual

HID

HID Miniprox User manual

HID iCLASS SE User manual

HID

HID iCLASS SE User manual

HID OMNIKEY eBase 1021 User manual

HID

HID OMNIKEY eBase 1021 User manual

HID iCLASS SE User manual

HID

HID iCLASS SE User manual

HID iCLASS SE U90 Series User manual

HID

HID iCLASS SE U90 Series User manual

HID EdgeReader User manual

HID

HID EdgeReader User manual

HID iCLASS RK40 User manual

HID

HID iCLASS RK40 User manual

HID Technology Solutions 1139 User manual

HID

HID Technology Solutions 1139 User manual

HID iCLASS R90 Manual

HID

HID iCLASS R90 Manual

HID iCLASS SE R10EB User manual

HID

HID iCLASS SE R10EB User manual

HID iCLASS SE R10F User manual

HID

HID iCLASS SE R10F User manual

HID iCLASS R10 User manual

HID

HID iCLASS R10 User manual

HID MiniProx 5365 User manual

HID

HID MiniProx 5365 User manual

HID SmartID SK10 User manual

HID

HID SmartID SK10 User manual

HID ProxPro II Reader User manual

HID

HID ProxPro II Reader User manual

HID iCLASS SE Express R10 User manual

HID

HID iCLASS SE Express R10 User manual

HID OMNIKEY 5121 User manual

HID

HID OMNIKEY 5121 User manual

Popular Card Reader manuals by other brands

MSI StarReader mini II Specifications

MSI

MSI StarReader mini II Specifications

Embedded SW EMUFDD user manual

Embedded SW

Embedded SW EMUFDD user manual

Gallagher T20 Installation note

Gallagher

Gallagher T20 Installation note

EPS Move Desk 3500 user manual

EPS

EPS Move Desk 3500 user manual

ACS ACR1255U-J1 user manual

ACS

ACS ACR1255U-J1 user manual

Icidu SI-707209 user manual

Icidu

Icidu SI-707209 user manual

Panasonic AJ-PCD35 operating instructions

Panasonic

Panasonic AJ-PCD35 operating instructions

Orbit Research Orbit Reader 20 user guide

Orbit Research

Orbit Research Orbit Reader 20 user guide

Salto WRD90E4xY installation guide

Salto

Salto WRD90E4xY installation guide

Digitus DA-70333 Quick installation guide

Digitus

Digitus DA-70333 Quick installation guide

Micro Innovations USB740R Quick installation guide

Micro Innovations

Micro Innovations USB740R Quick installation guide

Cognex DataMan 300L Quick reference guide

Cognex

Cognex DataMan 300L Quick reference guide

Hama 00124022 operating instructions

Hama

Hama 00124022 operating instructions

GeoVision GV- RK1352 instruction manual

GeoVision

GeoVision GV- RK1352 instruction manual

TransCore encompass 4 Guide

TransCore

TransCore encompass 4 Guide

PERCo IC02.1 Assembly and operation manual

PERCo

PERCo IC02.1 Assembly and operation manual

Balogh MOL81 485 1312 user manual

Balogh

Balogh MOL81 485 1312 user manual

Allflex RS250-V2 user manual

Allflex

Allflex RS250-V2 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.