Copyright HK Instruments 2017 www.hkinstruments. Installaon version 5.0 2017
INSTALLATION
INSTRUCTIONS
CARBON DIOXIDE TRANSMITTERS
CDT2000 Duct Series
• READ THESE INSTRUCTIONS CAREFULLY BEFORE
ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS
DEVICE.
• Failuretoobservesafetyinformaonandcomplywith
instruconscanresultinPERSONALINJURY,DEATHAND/OR
PROPERTY DAMAGE.
• Toavoidelectricalshockordamagetoequipment,disconnect
powerbeforeinstallingorservicinganduseonlywiringwith
insulaonratedforfulldeviceoperangvoltage.
• Toavoidpotenalreand/orexplosiondonotuseinpotenally
ammableorexplosiveatmospheres.
• Retaintheseinstruconsforfuturereference.
• Thisproduct,wheninstalled,willbepartofanengineered
systemwhosespecicaonsandperformancecharacteriscs
arenotdesignedorcontrolledbyHKInstruments.Review
applicaonsandnaonalandlocalcodestoassurethatthe
installaonwillbefunconalandsafe.Useonlyexperiencedand
knowledgeabletechnicianstoinstallthisdevice.
SPECIFICATIONS
Thank you for choosinganHKInstruments CDT2000 Ductseries
carbon dioxide transmier. The CDT2000 Duct series is intended
foruseincommercialenvironmentsinHVAC/Rapplicaons.
TheCDT2000Ductseriesmeasurescarbondioxide(CO2),ulizing
theindustrystandardNDIRmeasurementprinciple,andtempera-
ture(T).Illuminateddisplayensureseasyreadabilityalsofromadis-
tance.TheCDT2000Ducthasascrewlesslidandaneasilyadjust-
ablemounngangethatmaketheinstallaonofthedeviceeasy.
TheCDT2000 Duct seriestransmierscalibrate themselvesauto-
macallyusingABCTMlogic.TheABCTMlogicrequiresthatthespace
inwhichthetransmierisusedneedstotobeunoccupiedforfour
hours per day so that the indoor CO2 concentraon drops to the
outside level. CDT2000-DC Duct is a dual channel model with a
measuringchannelandareferencechannelthatmakesaconnuous
comparisonandthenecessaryadjustmentaccordingly.CDT2000-
DCDuctisalsosuitableforbuildingsthatareconnuouslyoccupied.
CDT2000Ductseriesdevicesarecommonlyusedtomonitor:
• CO2levelsofincomingandreturnairinvenlaonsystem
•CDT2000-DCDuctseriesdevicescanalsobeusedinapplicaons
wherethereisaconstantsourceofcarbondioxidepresent(for
examplehospitalsandgreenhouses)
SPECIFICATIONS
Performance
Measurement ranges:
CO2:400–2000ppm
Temperature:0...50° °F 32...122 /C
Accuracy:
CO2:±40ppm+2%ofreading,DCmodel:75ppmor
10%ofreading(whicheverisgreater)
Temperature:<0.5º °F <0.9 /C
Technical Specicaons
Media compability:
Dryairornon-aggressivegases
Measuring units:
ppmand°C
Measuring element:
CO2:Non-dispersiveinfrared(NDIR)
Temperature:NTC10K
Calibraon:
Automacself-calibraonABCLogicTMorconnuous
comparison(DC)
Environment:
Operangtemperature:0...50° °F 32...122 /C
Storagetemperature:-20...70° °F -4...158 /C
Humidity:0to95%rH,noncondensing
Physical
Dimensions:
Case:119x100x44.7m 1.76" x 3.94 x 4.69 /m
Probe:L=188mm,d=12m d=0.47" 7.40",L= /m
Mounng:
Withange,adjustable0...188mm 0...7.40" /
Weight:
150 oz 5.30 /g
Materials:
Case:ABS
Cover:PC
Probe:ABS
Protecon standard:
IP54
Electrical connecons:
4springloadedterminals
(24V,GND,CO2, T)
0.2–1.5mm2(12–24AWG)
Electrical
Supplyvoltage:24VACorVDC±10%
Currentconsumpon:max230mA(at24V)+10mA
foreachvoltageoutput
Outputsignalsforeverymedia:
0/2...5/10VDC,LoadRminimum1kΩ
Conformance
MeetsrequirementsforCEmarking:
EMCDirecve2014/30/EU
RoHSDirecve2011/65/EU
WEEEDirecve2012/19/EU