Operation Instructions
Backlight (optional) :
Press and hold key till the scale sounds
beep to enable / disable the Backlight.
UNIT:
Select the weight mode: kg / pcs.
Under pcs (simple counting) mode:
!!
The suggested unit weight of the measured
subject should be heavier than the division of
this scale.
1. Put 100 pieces of the measured subject (with the
same unit weight) on the platter.
2. Press and hold [UNIT] key till LCD shows S= 10,
and then quickly (within 3 seconds) press [UNIT]
key again to select S=100 (10、20、50、100 could
be selected for the sample-quantity of the
measured subject).
3. Wait till LCD shows 100. The scale has finish
calculating the averaging unit weight of the
measured subject. Now the simple counting
function is ready. This scale could be used as a
simple counting scale.