Insufficient Unit Weight Indication ():
Cursor appears on the bottom edge of UNIT
WEIGHT LCD (above of S.W printed on the
display-overlay), and indicates the averaging unit
weight is too light.
The internal resolution of this scale is 3000. While
the averaging unit weight of measured subjects is
lighter than “max capacity / 3000”, cursor will
flash on UNIT WEIGHT LCD. For example:
With 15kg max capacity; and the internal resolution
is 3000. 15kg / 3000 = 5g. If the averaging unit
weight of measured subjects is lighter than 1g,
cursor will flash on UNIT WEIGHT LCD (above of
S.W printed on the display-overlay).
Operation Instructions
Battery Symbol ():
When WEIGHT LCD indicates and the scale
sounds beep for four times, it means the battery is
running in low-voltage status. LCD will indicate
continuously for reminding the user to recharge the
battery. If the battery is still running in low-voltage
status without being recharged, WEIGHT LCD will
indicate -OFF-and the scale will sound beep for
eight times. Please power off the scale and