
SATEL INT-SF 7
Access if armed [Code*in arm] – if the option is enabled, the users can gain access (turn
the relay output on) when the partition is armed. If the option is disabled, the users cannot
gain access when the partition is armed. The option is available, if the “Code+* do not
disarm” option is enabled. The option does not apply to the “ON if partition armed” mode.
Users [Master users / Users] – the administrators and users which are permitted to use the
keypad.
FIRE alarm – if this option is enabled, pressing and holding the key for 3 seconds will
trigger the fire alarm.
AUX. alarm [Medical alarm] – if this option is enabled, pressing and holding the key
for 3 seconds will trigger the medical alarm.
PANIC alarm – if this option is enabled, pressing and holding the key for 3 seconds
will trigger the panic alarm.
silent [Silent panic] – if this option is enabled, the panic alarm triggered from the keypad will
be a silent one, i.e. the keypad will not indicate it, there will be no audible signal, but the
alarm will be reported to the monitoring station. The silent panic alarm is useful when the
control panel is sending events to the monitoring station, but unauthorized persons should
not be aware of the alarm being triggered. This option is available, if the “PANIC alarm”
option is enabled.
Alarm 3 incorrect codes [3 wrong codes] – if this option is enabled, entering a wrong code
three times will trigger an alarm.
Quick arming [Quick arm] – if this option is enabled, the user needs no code to arm the
partition using the keypad.
Control “BI” output [BI outs ctrl.] – if this option is enabled, the ““Bi” output operating” type
of users can use the keypad to control outputs.
Control “MONO” output [MONO outs ctr.] – if this option is enabled, the ““Mono” output
operating” type of users can use the keypad to control outputs.
Partition blocking [Part.blocking] – if the option is enabled, using the code by a user of the
“Blocking partition” or “Guard” type will block the armed partition (violating a zone
belonging to the partition will trigger no alarm). The duration of blocking is to be defined for
the partition or the user (the user of “Blocking partition” type).
Guard round control [Guard control] – if this option is enabled, using the code by a user of
the “Guard” type will be registered as the guard round.
Changing access code [Changing code] – if this option is enabled, the user can change
own code from the keypad.
Exit delay clearing enable [Fin.exit time] – if the option is enabled, the user can terminate
the partition exit delay countdown by pressing successively and (if the “Exit
delay clearing” option is enabled for the partition).
Alarm signal [Alarm (time)] – if this option is enabled, the keypad will audibly signal alarms
throughout the “Global alarm time” (parameter programmed in the control panel).
Alarm signal (until canceled) [Alarm (latch)] – if this option is enabled, the keypad will
audibly signal alarms until they are cleared.
Sign. entry delay [Entry time] – if this option is enabled, the keypad will audibly signal the
entry delay countdown.
Sign. exit delay [Exit time] – if this option is enabled, the keypad will audibly signal the exit
delay countdown.
Auto-Arm delay countdown [Auto-arm delay] – if this option is enabled, the partition keypad
will audibly signal the auto-arm delay countdown.
Acc. code sign. (hardware) [Code entered] – if this option is enabled, the partition keypad
will confirm with a single beep that the code has been entered. The signaling is useful