manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Honeywell
  6. •
  7. Security Sensor
  8. •
  9. Honeywell FG-730 User manual

Honeywell FG-730 User manual

Pull the wiring into the unit through the back cover. Using the two mounting
screws, mount the rear housing at the desired location.
For corner mounting
(score and pull flap open)
The FG-730 is a dual technology glassbreak detector that uses flex
detection and audio discrimination to detect breaking glass.
The flex and audio technologies are sensitive to different frequencies. The
flex technology is sensitive to ultra low frequencies, the type generated by
a blow to a glass window. The audio technology detects the frequency of
breaking glass.
The audio technology remains off until the flex technology detects a blow
to the glass. For an alarm condition to occur, the audio must detect the
frequency of breaking glass within a defined time-window after the flex
detects a blow to the glass. Because both technologies must detect and
verify glass breakage, false alarms are virtually eliminated.
Note: If you plan to corner-mount the unit, remove the printed
circuit board before marking and drilling holes for the mounting
screws.
.
Knockouts
REAR HOUSING
FRONT HOUSING
WIRING
Observing the proper polarity, wire the unit as shown in Figure 2 (use 22
to 14 AWG). Reverse-polarity connections will not damage the unit.
NC
Tamper
Form A (NC)
50 mA, 30 VDC
Alarm
Form C
500 mA max, 30 VDC max,
30 VA max
Power
10 - 14 VDC
25 mA, 12 VDC V+
V-
C
NO
C
NC
Figure 2 FG-730 Terminal Strip
FLEX ADJUSTMENT
To adjust the flex technology: Use a screwdriver to set the flex sensitivity
control (R5) at MAXIMUM by turning it all the way clockwise. Refer to Figure
3 on the back side of this page.
Turn on any heating/air conditioning system in the vicinity and observe the
yellow flex LED (DS2) for approximately one minute. Excessive subsonic
(inaudible) noise typically produced by air handling systems may cause
the flex LED to flash randomly.
If it flashes randomly, turn the R5 control counterclockwise just until the
flashing stops.
FEATURES
Dual flex/audio technology
Low 10 - 14 VDC operation
Alarm memory
Indicator LEDs
Energized form C alarm relay
Circuit protection
Cover tamper switch
Noise burst rejection circuit
RFI immunity
UL listed
.
..
.
.
.
.
.
.
.
MOUNTING LOCATION
The FG-730 can be mounted on walls, in corners, even on false or suspended
ceilings. Refer to the guidelines below when selecting a mounting location.
The unit must have a direct line of sight to, and a clear view of,
the protected glass.
Locate the FG-730 within 30' (9 m) of the glass to be protected.
.
.
Curtains, blinds, and other window coverings will absorb energy
from breaking glass. Heavy curtains, for example, will effectively
block the sound signal. In these cases, mount the unit on the window
frame behind the window covering, or above the window. Make
sure to test the unit thoroughly for proper detection.
.
Do not mount the unit in front of air ducts or forced air fans, or
close to bells measuring 2" (5 cm) or larger in diameter.
.
MOUNTING PROCEDURE
Orient the unit as shown in Figure 1. Remove the screw located at its top.
While depressing the latch near the top of the unit, swing the front cover
forward. Use the back cover as a template to mark holes for the mounting
screws and wiring, then drill the holes.
TESTING THE FG-730
Use the FG-701 Glassbreak Simulator to test the FG-730 detector. The FG-
700 may also be used.
Activate the simulator in MANual mode at the farthest point of the glass to
be protected (30' maximum). If the green LED (DS1) on the detector
flashes, the audio technology will detect breaking glass at that distance.
Test the flex technology by carefully striking the glass with a cushioned tool.
If the yellow LED on the detector flashes, the flex technology will be sensitive
enough to detect a blow to the glass at that distance.
FlexGuard®Dual Technology
Glassbreak Detector
INSTALLATION INSTRUCTIONS
Model
FG-730 30' range
For surface mounting
After removing screw at top of
unit, depress this latch to open
housing
Figure 1
Mounting
the FG-730
Low 25 mA at 12 VDC current
draw
No adjustment on audio
.
.
Adjustment on flex detection
to fit characteristics of each
location
.
SPECIFICATIONS:
Range:
FG-730 30' (9 m)
Alarm relay:
Form C
500 mA max
30 VDC max
Tamper switch:
Form A (NC)
50 mA, 30 VDC
Power requirements:
10 - 14 VDC
25 mA, 12 VDC
Dimensions:
3.9" H x 2.4" W x 0.79" D
(98 mm x 61.5 mm x 20 mm)
Weight:
3 oz (85 g)
Operating temperature:
32oF to 120o F (0o C to 49oC)
(Indoor use environment)
Testing the FG-730 (continued)
Switch the FG-701 simulator to the FLEX mode and generate a flex signal
by carefully striking the glass. The simulator will automatically generate a
burst of glass-break sound, and the red LED (DS3) on the FG-730 should
light to indicate an alarm condition.
See the FG-701 operating instructions for additional testing information.
To ensure maximum protection against false alarms, activate any device in
the area that may automatically cycle: pumps, generators, heating/air
conditioning units, etc. If the cycling devices trigger an alarm, mount the
unit in a different location.
There is no need to relocate the detector if the cycling only briefly triggers
the flex technology (the yellow LED flashes).
FINAL TESTING
ALARM MEMORY
The FG-730 is equipped with a
latching circuit for the alarm LED.
When the latching circuit is
activated, an alarm condition will
make the red alarm LED on the
units latch on. This feature is
particularly helpful in determining
which unit alarmed in a multiple
detector installation.
To activate the latching circuit,
install a jumper at position W2 on
the printed circuit board. Refer
to Figure 3. To reset the latched
alarm LED, remove then restore
power to the detector.
Figure 3 Testing the
FG-730
Approvals:
UL listed
CE
To obtain applicable EU
compliance Declaration of
Conformities for this
product, please refer to
our Website, http://
www.security.honeywell.com/
hsce/international/index.html.
For any additional information
regarding the compliance of
this product to any EU
specific requirements, please
contact:
Honeywell Security &
Communications
Honeywell Security -
Quality Assurance Dept.
Newhouse Industrial Estate
Motherwell
Lanarkshire ML1 5SB
Scotland
United Kingdom
Tel: +44(0)1698 738200
Email:
[email protected]
Glass types:
1/8", 3/16", and 1/4" plate;
1/4" laminated, wired, and
tempered;
minimum size 10-7/8" x 10-7/8",
single pane
NOTE: The FG-730 should be tested at least once each year to
ensure proper operation.
Important: The FG-730 must be connected to a UL listed power
supply or UL listed control unit capable of providing a
minimum of four hours of standby power.
Note: The latching circuit has
absolutely no effect on the
alarm relay. The alarm relay
will continue to function as
normal.
©2004 Honeywell International Inc. • Honeywell, IntelliSense and DUAL TEC are registered trademarks of
Honeywell International Inc. All other trademarks are the properties of their respective owners. All rights reserved.
IMPORTANT NOTICE
All FlexGuard®Glassbreak Detectors
Due to the variation of acoustics in different environments, (i.e. ceiling
mount units, big open rooms, soft environments), all units must be
tested with the FG-701 Glassbreak Simulator. No unit should be
mounted outside the effective range of the simulator.
For the latest U.S. warranty information, please go to: www.honeywell.com/security/hsc/resources/wa or
Please contact your local authorised Honeywell representative for product warranty information. Ê5-051-169-006Š
5-051-169-00 7/14 Rev. J

Other manuals for FG-730

1

Other Honeywell Security Sensor manuals

Honeywell PEHA MLS Digital Hi-Bay D MLS2001AHBF Installation and operation manual

Honeywell

Honeywell PEHA MLS Digital Hi-Bay D MLS2001AHBF Installation and operation manual

Honeywell BW Ultra User manual

Honeywell

Honeywell BW Ultra User manual

Honeywell Fire-Lite Alarms D365PL User manual

Honeywell

Honeywell Fire-Lite Alarms D365PL User manual

Honeywell 5800PIR-COM User manual

Honeywell

Honeywell 5800PIR-COM User manual

Honeywell FS24X User manual

Honeywell

Honeywell FS24X User manual

Honeywell C554A User manual

Honeywell

Honeywell C554A User manual

Honeywell Miller Falcon MP50G-LE Installation instructions

Honeywell

Honeywell Miller Falcon MP50G-LE Installation instructions

Honeywell EC-FX-NH3 Manual

Honeywell

Honeywell EC-FX-NH3 Manual

Honeywell DT7235T User manual

Honeywell

Honeywell DT7235T User manual

Honeywell Connected Home CAMIR-8EZS User manual

Honeywell

Honeywell Connected Home CAMIR-8EZS User manual

Honeywell HAQSPA User manual

Honeywell

Honeywell HAQSPA User manual

Honeywell IntelliSense FG-1625RFM User manual

Honeywell

Honeywell IntelliSense FG-1625RFM User manual

Honeywell Sensepoint User manual

Honeywell

Honeywell Sensepoint User manual

Honeywell RCA902N User manual

Honeywell

Honeywell RCA902N User manual

Honeywell Ex-Or MLS2500CDR Installation and operation manual

Honeywell

Honeywell Ex-Or MLS2500CDR Installation and operation manual

Honeywell FF-SB12 Series User manual

Honeywell

Honeywell FF-SB12 Series User manual

Honeywell 2MLF-RD4A User manual

Honeywell

Honeywell 2MLF-RD4A User manual

Honeywell Miller AirCore Oil & Gas Harness User manual

Honeywell

Honeywell Miller AirCore Oil & Gas Harness User manual

Honeywell PROINDMV Assembly instructions

Honeywell

Honeywell PROINDMV Assembly instructions

Honeywell 1031030 User manual

Honeywell

Honeywell 1031030 User manual

Honeywell Miller Titan TR50 User manual

Honeywell

Honeywell Miller Titan TR50 User manual

Honeywell IRPI8EZS User manual

Honeywell

Honeywell IRPI8EZS User manual

Honeywell Ex-Or LS3043DR User manual

Honeywell

Honeywell Ex-Or LS3043DR User manual

Honeywell FF-SPS4 Series User manual

Honeywell

Honeywell FF-SPS4 Series User manual

Popular Security Sensor manuals by other brands

iMSENS iMSL Plafon Urano quick start guide

iMSENS

iMSENS iMSL Plafon Urano quick start guide

Verkada BR34 install guide

Verkada

Verkada BR34 install guide

steute ST 98 Mounting and wiring instructions

steute

steute ST 98 Mounting and wiring instructions

Niko 350-20072 manual

Niko

Niko 350-20072 manual

Di-soric OBS 105 M 30 INC-x user manual

Di-soric

Di-soric OBS 105 M 30 INC-x user manual

Dahua ITC214-PH5B-F3-POE user manual

Dahua

Dahua ITC214-PH5B-F3-POE user manual

Texecom CAPTURE D20-W manual

Texecom

Texecom CAPTURE D20-W manual

Bosch DS1109i installation guide

Bosch

Bosch DS1109i installation guide

Rokonet Zodiac Quad RK-410RQ installation instructions

Rokonet

Rokonet Zodiac Quad RK-410RQ installation instructions

DMP Electronics XTLplusINT Series Installation and programming guide

DMP Electronics

DMP Electronics XTLplusINT Series Installation and programming guide

Theben TIMEGUARD PDFM361AB Installation & operating instructions

Theben

Theben TIMEGUARD PDFM361AB Installation & operating instructions

GD Import 084474 quick start guide

GD Import

GD Import 084474 quick start guide

MedicalAlert SMOKE DETECTOR Setup guide

MedicalAlert

MedicalAlert SMOKE DETECTOR Setup guide

Bosch DS9360 installation guide

Bosch

Bosch DS9360 installation guide

teko Astra-7 user guide

teko

teko Astra-7 user guide

Ecolink ClearSky CS-242 Installation instructions & user manual

Ecolink

Ecolink ClearSky CS-242 Installation instructions & user manual

Nobile N 5020 COB LED 3 Set Mounting and operation instructions

Nobile

Nobile N 5020 COB LED 3 Set Mounting and operation instructions

RIDGID NaviTrack Scout operating instructions

RIDGID

RIDGID NaviTrack Scout operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.