HUBBCOM GRC600 Remote Station
Quick Installation Guide
GAI-TRONICS 3030 KUTZTOWN RD. READING, PA 19605 USA
610-777-1374 ◼800-492-1212 ◼Fax: 610-796-5954
VISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
General Information
This guide covers the installation of the HUBBCOM Remote Station, Model GRC600. The Model GRC600
Remote Station is designed for access control See the GAI-Tronics website at https://www.gai-tronics.com for
system specifications, warranty information, and the GUDA (GAI-Tronics Universal Device Application).
Important Safety Instructions
•Read, follow, and retain instructions—All safety and operating instructions should be read and followed
before operating the unit. Retain instructions for future reference.
•Heed warnings—Adhere to all warnings on the unit and in the operating instructions.
•Attachments—Attachments not recommended by the product manufacturer should not be used, as they may
cause hazards.
•Servicing—Do not attempt to service this unit by yourself. Opening or removing covers may expose you to
dangerous voltage or other hazards. Refer all servicing to qualified service personnel.
•Changes or Modifications Not Expressly Approved By GAI-Tronics For Compliance Could Void The
User's Authority To Operate The Equipment.
ATTENTION
—Install equipment without modification and according to all applicable local,
national, and international electrical codes. North America - Consult the National Electrical Code (NFPA 70),
Canadian Standards Association (CSA 22.1), and local codes for specific requirements regarding your installation.
Class 2 circuit wiring must be performed in accordance with the NEC.
These enclosures must be installed by trained, qualified and competent personnel. Installation must comply with
state and national regulations, as well as safety practices for this type of equipment.
WARNING
—Use only 24 V dc power supplies that conform to UL/CSA/CE Class II, Double Insulated
supplies with over voltage and short circuit protection. Use only a dc source with a 50-
watt maximum output or fuse the supply with a 2-amp fuse. EMI standards to Class B.
•Onderhoud—Probeer dit apparaat niet zelf te repareren. Het openen of verwijderen van afdekkingen kan u
blootstellen aan gevaarlijke spanning of andere gevaren. Laat alle onderhoud over aan bevoegd
onderhoudspersoneel.
•HUBBCOM Smart Controllers zijn alleen bedoeld voor gebruik binnenshuis.
AANDACHT
—Gebruik alleen 24 VDC-voedingen die voldoen aan UL / CSA / CE Klasse II, dubbel
geïsoleerde voedingen met overspanning en kortsluitbeveiliging. Gebruik alleen een
DC-bron met een maximale output van 50 W of fuseer de voeding met een 2-ampère
zekering. EMI-normen voor klasse B.
•Dépannage—N'essayez pas de réparer cet appareil vous-même. Ouvrir ou retirer les capots peut vous exposer à
des tensions dangereuses ou à d'autres dangers. Confiez toute réparation à un personnel qualifié.
•Les contrôleurs intelligents HUBBCOM sont conçus pour une utilisation en intérieur uniquement.

Pub. 42004-538AQG
HUBBCOM GRC600 Remote Station Quick Installation Guide Page 2 of 5
C:\Users\PDrenning\AppData\Local\Microsoft\Windows\INetCache\Content.Outlook\PB6OVX22\HUBBCOM GRC600 Remote Station Quick Installation
Guide.docx
10/19
ATTENTION
—Utilisez uniquement des alimentations 24 Vcc conformes à UL / CSA / CE Classe II, des
alimentations à double isolation avec protection contre les surtensions et les courts-
circuits. Utilisez uniquement une source cc avec une sortie maximale de 50 watts ou
fusionnez l’alimentation avec un fusible de 2 ampères. Normes EMI à la classe B.
•Manutenzione—non tentare di riparare l'unità da soli. L'apertura o la rimozione dei coperchi potrebbero esporre
a tensioni pericolose o altri rischi. Rivolgersi a personale qualificato per l'assistenza.
•Gli HUBBCOM Smart Controller sono progettati esclusivamente per uso interno.
AVVERTIMENTO
—Utilizzare solo alimentatori a 24 V cc conformi a UL / CSA / CE Classe II,
alimentatori a doppio isolamento con protezione da sovratensione e cortocircuito.
Utilizzare solo una fonte di corrente continua con un'uscita massima di 50 watt o
collegare l'alimentazione con un fusibile da 2 A. Standard EMI per la classe B.
•Mantenimiento—no intente reparar esta unidad por sí mismo. Abrir o quitar las cubiertas puede exponerlo a un
voltaje peligroso u otros peligros. Remita todo el servicio a personal de servicio calificado.
•Los controladores inteligentes HUBBCOM están diseñados para uso en interiores solamente.
ADVERTENCIA
—Utilice solo fuentes de alimentación de 24 V cc que cumplan con UL / CSA / CE
Clase II, fuentes con doble aislamiento con sobretensión y protección contra
cortocircuitos. Utilice solo una fuente de CC con una salida máxima de 50 vatios o
fusione la fuente con un fusible de 2 amperios. Estándares EMI a Clase B.
Installation
The HUBBCOM Remote Station can be surface mounted on a wall or flush mounted using a (customer provided)
two-gang electrical box.
Safety Hardware
The HUBBCOM Remote Station described in this manual is vandal resistant. The front cover is attached to the
mounting plate with security screws. A Torx T-10 security screwdriver is required to install the station.
Surface-mount
1. Remove the two security screws from the bottom of the station.
2. Drill two holes through the mounting plate at the drill points and corresponding holes in the mounting surface.
3. Secure the mounting plate to the wall using ? (customer supplied).
4. Feed the Ethernet cable and all additional cables through the hole in the mounting plate.
5. Complete all necessary cable terminations (see the Wiring section).
6. Assemble the front cover to the mounting plate and secure it with the two security screws removed from the
bottom of the station in Step 1.
7. Tighten the screws to 3–5 in∙lb.
Flush-mount
NOTE:A customer supplied two-gang electrical box is required to flush-mount the HUBBCOM Remote Station.
1. Install the two-gang electrical box in the mounting surface.
2. Remove the two security screws from the bottom of the station.
3. Feed the Ethernet cable and all additional cables into the electrical box and through mounting plate.
4. Assemble the mounting plate to the electrical box using #6-32 x ½-inch flat head screws (customer supplied).
5. Complete all necessary cable terminations (see the Wiring section).

Pub. 42004-538AQG
HUBBCOM GRC600 Remote Station Quick Installation Guide Page 3 of 5
C:\Users\PDrenning\AppData\Local\Microsoft\Windows\INetCache\Content.Outlook\PB6OVX22\HUBBCOM GRC600 Remote Station Quick Installation
Guide.docx
10/19
6. Assemble the front cover to the mounting plate and secure with the two security screws removed from the
bottom of the station in Step 2.
7. Tighten the screws to 3–5 in∙lb.
Wiring
HUBBCOM Remote stations are equipped with screw connection terminal blocks that accept 26–16 AWG wires.
Power
Complete the following steps to terminate the input power cable at terminal block TB1:
1. Install appropriately sized ferrules onto the wire ends.
2. Install each wire into the correct terminal (See Table 1).
Table 1.
Purpose
Term Block-Pin
Label
Power −
TB1-1
−
Power +
TB1-2
+
Ethernet
Complete the following steps to terminate the Ethernet cable at terminal block TB2:
1. Install appropriately sized ferrules onto the wire ends.
2. Install each wire into the correct terminal (See Table 2).
Table 2.
Purpose
Term Block-Pin
Label
Ethernet
TB2-1
A+
Ethernet
TB2-2
A-
Ethernet
TB2-3
B+
Ethernet
TB2-4
C+
Ethernet
TB2-5
C-
Ethernet
TB2-6
B-
Ethernet
TB2-7
D+
Ethernet
TB2-8
D-
Output Contacts
Complete the following steps to terminate the output connections at terminal block TB3:
1. Install appropriately sized ferrules onto the wire ends.
2. Install each wire into the correct terminal (See Table 3).

Pub. 42004-538AQG
HUBBCOM GRC600 Remote Station Quick Installation Guide Page 4 of 5
C:\Users\PDrenning\AppData\Local\Microsoft\Windows\INetCache\Content.Outlook\PB6OVX22\HUBBCOM GRC600 Remote Station Quick Installation
Guide.docx
10/19
Table 3.
Purpose
Term Block-Pin
Label
Output
TB3-1
GND
Output
TB3-2
+
USB1 & USB2
Complete the following steps to terminate the USB connections at terminal blocks TB4 and TB5:
1. Install appropriately sized ferrules onto the wire ends.
2. Install each wire into the correct terminal (See Table 4).
Table 4.
Purpose
Term Block-Pin
Label
USB1
TB4-1
GND
TB4-2
DP
TB4-3
DN
TB4-4
P
USB2
TB5-1
GND
TB5-2
DP
TB5-3
DN
TB5-4
P
Data/Input Contacts
Complete the following steps to terminate the data and input connections at terminal block TB6:
1. Install appropriately sized ferrules onto the wire ends.
2. Install each wire into the correct terminal (See Table 5).

Pub. 42004-538AQG
HUBBCOM GRC600 Remote Station Quick Installation Guide Page 5 of 5
C:\Users\PDrenning\AppData\Local\Microsoft\Windows\INetCache\Content.Outlook\PB6OVX22\HUBBCOM GRC600 Remote Station Quick Installation
Guide.docx
10/19
Table 5. Input Terminations at Terminal Block TB6
Purpose
Term Block-Pin
Label
TB6-1
DG
TB6-2
D1
TB6-3
D0
TB6-4
IN4
TB6-5
GND
TB6-6
IN3
TB6-7
GND
TB6-8
IN2
TB6-9
GND
TB6-10
IN1
Service and Spare Parts
Contact a regional service center for assistance if the equipment requires service or spare parts. An RA# ( return
authorization number) will be issued if service is required. Equipment must be shipped prepaid to GAI-Tronics with
a return authorization number and a purchase order number. Repairs or a replacement will be made in accordance
with GAI-Tronics’ warranty policy if the equipment is under warranty. Please include a written explanation of all
defects to assist our technicians in their troubleshooting efforts. Call 800-492-1212 inside the USA or 610-777-1374
outside the USA for help with identifying the regional service center closest to you.
Specifications
Temperature Range..................................................................................................−30 °C to 66 °C (−22 °F to 150 °F)
Approvals
Compliance to Standard....................................................................................................FCC CFR 47 Part 15 Class A
FCC ID: XXXYYYYYYYYYYYYYY
(IC ONLY) IC: XXXXX-XXXXXXXXXXX
(IC ONLY) TRADE NAME: TTTTTT
MODEL (NUMBER): MMMMM
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Table of contents
Other Hubbell Control Unit manuals

Hubbell
Hubbell GAI-TRONICS HUBBCOM GRC600 User manual

Hubbell
Hubbell H-MOSS CU300HD User manual

Hubbell
Hubbell wiSTAR WIS-IDM User manual

Hubbell
Hubbell GAI-TRONICS 378-003 E3 IP MIM User manual

Hubbell
Hubbell GAI-TRONICS E3 User manual

Hubbell
Hubbell wiHUBB User manual

Hubbell
Hubbell Gai-Tronics 12504-009 User manual

Hubbell
Hubbell GAI-TRONICS 379-003 IP MRM User manual

Hubbell
Hubbell GAI-TRONICS HUBBCOM GRC600SS User manual

Hubbell
Hubbell GAI-Tronics Elemec3 MIM User manual