Hydrofarm Active Air Series User manual

5
5
on reflective
materials
INSTRUCTIONS MANUAL
IN-LINE DUCT FANS
Mounting Options
SERIES
FIGURE 1
FIGURE 2
5
5
on reflective
materials
INSTRUCTIONS MANUAL
IN-LINE DUCT FANS
Mounting Options
SERIES
FIGURE 1
FIGURE 2
READ AND SAVE THESE INSTRUCTIONS
CAUTION: Before carrying out any maintenance or servicing, ensure
the unit is disconnected from the main supply. FOR GENERAL VEN-
TILATION USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS
OR EXPLOSIVE VAPOURS.
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRICAL
SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
WARNING:
• This fan must be isolated from the power supply during installation
and maintenance.
• This fan must be grounded in accordance with local regulations.
• This fan is tted with a non self-resetting thermal cut out which
switches the fan off in the event of a fault condition. To reset, turn the
power off for one minute, then back on. Only a qualied and compe-
tent person may carry out maintenance after the electrical supply has
been isolated.
• TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR IN-
JURY, OBSERVE THE FOLLOWING GUIDELINES:
a) Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer or place of purchase.
b) Active Air™ in-line duct fans are designed for use in up to 95%
relative humidity. They are not humidiers or dehumidiers. This fan is
not suitable for corrosive or explosive atmospheres.
c) Before servicing or cleaning the unit, disconnect the fan from the
power supply.
d) Installation work and electrical wiring must be done by a qualied
person(s) in accordance with all applicable codes and standards,
including re-rated construction.
e) When cutting or drilling into walls or ceilings, take care not to dam-
age electrical wiring and other hidden utilities.
f) Ducted fans should always be vented outside the area occupying
the garden for the most efcient operation.
g) NEVER allow the unit to directly contact moisture or wet environ-
ments.
h) Take caution when operating, this unit has an unguarded impeller,
therefore DO NOT use it in locations readily accessible to people or
animals.
INSTRUCTIONS:
1. Upon purchase, the fan equipment should be visually inspected
to check for any damage. Ensure that the impeller has free rotation
without scraping or catching on any part of the internal housing.
2. If there are any questions concerning the fan equipment, Hydro-
farm or the retailer should be contacted prior to the installation.
3. Use the mounting brackets included with the fan system to securely
fasten the unit in the desired mounting position. (Refer to FIGURE 1 &
2 for mounting options)
4. Check the details on the motor rating plate to ensure that the cor-
rect power supply (voltage, frequency and phase) is available. An
incorrect power supply may lead to permanent damage to the fan
motor.
5. Refer to the appropriate wiring diagram, and ensure that all ground
connections are made.
6. Means for electrical disconnection must be incorporated in the wir-
ing installation in accordance with the relevant wiring and electrical
regulations.
MAINTENANCE:
All Active Air™ series in-line duct fans incorporate sealed for life bear-
ings and therefore do not require any lubrication. We would recom-
mend inspection of the product at least once every 12 months to
ensure that the motor, impellor, and supporting guards are clean. All
fastenings should be checked for tightness and security. In addition,
all rotating items should be checked. To inspect the unit, disconnect it
from the power supply and any duct work. If debris is evident on the
impeller, clean it with a damp (not wet) cloth. DO NOT use any deter-
gents or abrasive materials for cleaning.
READ AND SAVE THESE INSTRUCTIONS
CAUTION: Before carrying out any maintenance or servicing, ensure
the unit is disconnected from the main supply. FOR GENERAL VEN-
TILATION USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS
OR EXPLOSIVE VAPOURS.
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRICAL
SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
WARNING:
• This fan must be isolated from the power supply during installation
and maintenance.
• This fan must be grounded in accordance with local regulations.
• This fan is tted with a non self-resetting thermal cut out which
switches the fan off in the event of a fault condition. To reset, turn the
power off for one minute, then back on. Only a qualied and compe-
tent person may carry out maintenance after the electrical supply has
been isolated.
• TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR IN-
JURY, OBSERVE THE FOLLOWING GUIDELINES:
a) Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer or place of purchase.
b) Active Air™ in-line duct fans are designed for use in up to 95%
relative humidity. They are not humidiers or dehumidiers. This fan is
not suitable for corrosive or explosive atmospheres.
c) Before servicing or cleaning the unit, disconnect the fan from the
power supply.
d) Installation work and electrical wiring must be done by a qualied
person(s) in accordance with all applicable codes and standards,
including re-rated construction.
e) When cutting or drilling into walls or ceilings, take care not to dam-
age electrical wiring and other hidden utilities.
f) Ducted fans should always be vented outside the area occupying
the garden for the most efcient operation.
g) NEVER allow the unit to directly contact moisture or wet environ-
ments.
h) Take caution when operating, this unit has an unguarded impeller,
therefore DO NOT use it in locations readily accessible to people or
animals.
INSTRUCTIONS:
1. Upon purchase, the fan equipment should be visually inspected
to check for any damage. Ensure that the impeller has free rotation
without scraping or catching on any part of the internal housing.
2. If there are any questions concerning the fan equipment, Hydro-
farm or the retailer should be contacted prior to the installation.
3. Use the mounting brackets included with the fan system to securely
fasten the unit in the desired mounting position. (Refer to FIGURE 1 &
2 for mounting options)
4. Check the details on the motor rating plate to ensure that the cor-
rect power supply (voltage, frequency and phase) is available. An
incorrect power supply may lead to permanent damage to the fan
motor.
5. Refer to the appropriate wiring diagram, and ensure that all ground
connections are made.
6. Means for electrical disconnection must be incorporated in the wir-
ing installation in accordance with the relevant wiring and electrical
regulations.
MAINTENANCE:
All Active Air™ series in-line duct fans incorporate sealed for life bear-
ings and therefore do not require any lubrication. We would recom-
mend inspection of the product at least once every 12 months to
ensure that the motor, impellor, and supporting guards are clean. All
fastenings should be checked for tightness and security. In addition,
all rotating items should be checked. To inspect the unit, disconnect it
from the power supply and any duct work. If debris is evident on the
impeller, clean it with a damp (not wet) cloth. DO NOT use any deter-
gents or abrasive materials for cleaning.

This manual suits for next models

1

Other Hydrofarm Fan manuals

Hydrofarm Active Air ACDF12 User manual

Hydrofarm

Hydrofarm Active Air ACDF12 User manual

Hydrofarm ACTIVE AIR HORF6 User manual

Hydrofarm

Hydrofarm ACTIVE AIR HORF6 User manual

Hydrofarm Active Air Series User manual

Hydrofarm

Hydrofarm Active Air Series User manual

Hydrofarm Active Air ACFP2018 User manual

Hydrofarm

Hydrofarm Active Air ACFP2018 User manual

Hydrofarm Active Air User manual

Hydrofarm

Hydrofarm Active Air User manual

Hydrofarm Active Air ACFP18 User manual

Hydrofarm

Hydrofarm Active Air ACFP18 User manual

Hydrofarm JETFAN PF1040 User manual

Hydrofarm

Hydrofarm JETFAN PF1040 User manual

Hydrofarm Active Air ACFW16HDB User manual

Hydrofarm

Hydrofarm Active Air ACFW16HDB User manual

Hydrofarm Active Air ACFV2018 User manual

Hydrofarm

Hydrofarm Active Air ACFV2018 User manual

Hydrofarm JETFAN JF13010 User manual

Hydrofarm

Hydrofarm JETFAN JF13010 User manual

Hydrofarm Active Air ACFP1016 User manual

Hydrofarm

Hydrofarm Active Air ACFP1016 User manual

Hydrofarm ACTIVE AIR ACFC6 User manual

Hydrofarm

Hydrofarm ACTIVE AIR ACFC6 User manual

Hydrofarm Active Air ACF16 User manual

Hydrofarm

Hydrofarm Active Air ACF16 User manual

Popular Fan manuals by other brands

JONATHAN Y Aldrin JYL9715A Use and care guide

JONATHAN Y

JONATHAN Y Aldrin JYL9715A Use and care guide

Optimus F-0610C instruction manual

Optimus

Optimus F-0610C instruction manual

S&P TPSB ECOWATT Series instruction manual

S&P

S&P TPSB ECOWATT Series instruction manual

SPT SF-1469 owner's manual

SPT

SPT SF-1469 owner's manual

Lindab Versio H installation instructions

Lindab

Lindab Versio H installation instructions

Craftmade MI52 Specifications

Craftmade

Craftmade MI52 Specifications

Temspec TL Installation, operation and maintenance manual

Temspec

Temspec TL Installation, operation and maintenance manual

Zephyr Verona Island ZVN-M90BG Use, care and installation guide

Zephyr

Zephyr Verona Island ZVN-M90BG Use, care and installation guide

ACME VQ80 quick start guide

ACME

ACME VQ80 quick start guide

Hunter 21587 Parts guide

Hunter

Hunter 21587 Parts guide

Ebmpapst S4E350-AA06-24 operating instructions

Ebmpapst

Ebmpapst S4E350-AA06-24 operating instructions

Ebmpapst A2D250-AI14-10 operating instructions

Ebmpapst

Ebmpapst A2D250-AI14-10 operating instructions

Homemaker TX-1201D user manual

Homemaker

Homemaker TX-1201D user manual

Ebmpapst W4E400-CP14-71 operating instructions

Ebmpapst

Ebmpapst W4E400-CP14-71 operating instructions

German pool EFB-226 user manual

German pool

German pool EFB-226 user manual

System air KBR Installation,operation and maintenance instruction

System air

System air KBR Installation,operation and maintenance instruction

Gaggenau AR 401 742 installation instructions

Gaggenau

Gaggenau AR 401 742 installation instructions

Canarm IDL series Operation instructions and parts manual

Canarm

Canarm IDL series Operation instructions and parts manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.