Torch sleeve, coupler, and gear rack replacemenT
4Field Service Bulletin
Kit 228736 contents
Part number Description Quantity
075618 Machine screw: 4-40 x 3/8 pan head 3
075754 Machine screw: 4-40 x 3/16 pan head 1
220808 Machine torch coupler 1
Disassemble the torch and remove the coupler
1. Turn OFF the power and disconnect the torch lead from the power supply.
2. Remove the consumables from the torch.
3. If applicable, unscrew the strain relief body from the strain relief nut and slide the strain relief body back along the
torch lead.
4. If applicable, unscrew the strain relief nut from the positioning sleeve (Full-length machine torch) and slide the nut
back along the torch lead.
5. Unscrew the positioning sleeve (Full-length machine torch) from the coupler.
6. Unscrew the coupler from the mounting sleeve.
7. Use a #1 Phillips screwdriver to remove the three screws from the consumables end of the mounting sleeve and
slide the mounting sleeve off the front of the torch body. Set the mounting sleeve aside.
8. Disconnect the wire connector for the cap-sensor switch.
9. Use a #1 Phillips screwdriver to remove the screw that secures the torch’s pilot wire to the torch body.
10. Use the 1/4-inch and 3/8-inch wrenches or two adjustable wrenches together, to loosen the nut that secures the
gas supply line to the torch lead. Set the torch body aside.
11. Slide the coupler off the front of the torch lead.
Reassemble the torch with the new coupler
1. Slide the new coupler over the front of the torch lead.
2. Use the 1/4-inch and 3/8-inch wrenches or two adjustable wrenches together, to tighten the nut that secures the
gas supply line to the torch lead.
3. Use a #1 Phillips screwdriver to tighten the screw that secures the torch’s pilot wire to the torch body to
5.76kg-cm (5 inch-pounds).
4. Connect the wire connector for the cap-sensor switch.
5. Slide the mounting sleeve over the front of the torch body, aligning the slot in the mounting sleeve with the cap
sensor plunger.
Replace the machine torch coupler
Please refer to Figures 1, 2, and 3 on page 2 when performing the following procedure.