Hypertherm T30v Reference manual

Field Service Bulletin
Bulletin de service sur le terrain
805260 Revision 2 January 2014
Révision 2 Janvier 2014
T30v Torch Lead Replacement
Remplacement du faisceau
de torche T30v

Hypertherm Inc.
Etna Road, P.O. Box 5010
Hanover, NH 03755 USA
603-643-3441 Tel (Main Office)
603-643-5352 Fax (All Departments)
800-643-9878 Tel (Technical Service)
800-737-2978 Tel (Customer Service)
866-643-7711 Tel (Return Materials Authorization)
877-371-2876 Fax (Return Materials Authorization)
Hypertherm Plasmatechnik GmbH
Technologiepark Hanau
Rodenbacher Chaussee 6
D-63457 Hanau-Wolfgang, Deutschland
49 6181 58 2100 Tel
49 6181 58 2134 Fax
49 6181 58 2123 (Technical Service)
Hypertherm (S) Pte Ltd.
82 Genting Lane
Media Centre
Annexe Block #A01-01
Singapore 349567, Republic of Singapore
65 6841 2489 Tel
65 6841 2490 Fax
65 6841 2489 (Technical Service)
Hypertherm (Shanghai) Trading Co., Ltd.
Unit 301, South Building
495 ShangZhong Road
Shanghai, 200231
PR China
86-21-60740003 Tel
86-21-60740393 Fax
Hypertherm Europe B.V.
Vaartveld 9
4704 SE
Roosendaal, Nederland
31 165 596907 Tel
31 165 596901 Fax
31 165 596908 Tel (Marketing)
31 165 596900 Tel (Technical Service)
00 800 4973 7843 Tel (Technical Service)
Hypertherm Japan Ltd.
Level 9, Edobori Center Building
2-1-1 Edobori, Nishi-ku
Osaka 550-0002 Japan
81 6 6225 1183 Tel
81 6 6225 1184 Fax
Hypertherm Brasil Ltda.
Rua Bras Cubas, 231 – Jardim Maia
Guarulhos, SP - Brasil
CEP 07115-030
55 11 2409 2636 Tel
55 11 2408 0462 Fax
Hypertherm México, S.A. de C.V.
Avenida Toluca No. 444, Anexo 1,
Colonia Olivar de los Padres
Delegación Álvaro Obregón
México, D.F. C.P. 01780
52 55 5681 8109 Tel
52 55 5683 2127 Fax
Hypertherm Korea Branch
#3904 Centum Leaders Mark B/D,
1514 Woo-dong, Haeundae-gu, Busan
Korea, 612-889
82 51 747 0358 Tel
82 51 701 0358 Fax
© 2014 Hypertherm Inc. All rights reserved. Tous droits réservés.
Powermax, Duramax, and Hypertherm are trademarks of Hypertherm Inc. and may be registered in the United States and/or other countries. All other
trademarks are the property of their respective holders.
Powermax, Duramax et Hypertherm sont des marques de commerce d’Hypertherm Inc. qui peuvent être déposées aux États-Unis et/ou dans d’autres
pays. Toutes les autres marques commerciales sont la propriété de leurs détenteurs respectifs.

Powermax30 Field Service Bulletin 805260 3
T30v Torch Lead Replacement
Introduction
Purpose
Describes the necessary steps to replace the torch lead on the T30v hand torch.
Tools and materials needed
Assorted Phillips®and TORX®screwdrivers
Blade screwdriver
8 mm (5/16 inch) nut driver
6 mm (1/4 inch) nut driver or adjustable wrench
10 mm (3/8 inch) wrench
228113 Kit contents
WARNING!
ELECTRIC SHOCK CAN KILL
Disconnect electrical power before performing any maintenance.
All work requiring removal of the power supply cover must be performed by
a qualified technician.
See the Safety and Compliance Manual (80669C) for more safety
precautions.
Part number Description Quantity
229086 Lead: T30v hand torch, 4.6 m (15 feet) 1
075504 Machine screw: 4-40 x 5/16 SW CN SEM PH PAN, S/Z 1
075503 Locknut: 4-40 self-locking nut 1

4Powermax30 Field Service Bulletin 805260
T30v Torch Lead Replacement
Replace the torch lead
Remove the power supply cover and component barrier
1. Set the power switch to OFF (O), disconnect the power cord from the power source, and disconnect the gas supply.
2. Remove the two screws from the handle on the top of the power supply. Gently pull on the panel nearest the screw
you are removing to keep pressure on the screw. When the screw is almost out, tilt the screwdriver slightly to help
pull the screw out of the recessed hole.
3. Slightly tip the front and rear panels away from the power supply so that you can get the edges of the handle out from
underneath them. Remove the handle, and set it and the two screws aside.
4. Continue to tilt the panels outward to release the fan side of the cover from its track. Then lift the cover off the power
supply.
5. Remove the component barrier from the power board side of the power supply. The barrier is flexible and can be bent
slightly for removal.
Component barrier

Powermax30 Field Service Bulletin 805260 5
T30v Torch Lead Replacement
Disconnect the lead from the power supply
1. Compress the hose fitting collar and pull the hose from the fitting to remove the gas hose from the solenoid valve.
2. Loosen the strain relief nut on the outside of the front panel.
3. Carefully tilt the front panel away from the power supply. Locate the 3-pin connector at the TORCH START slot (J12)
on the power board (on the side facing the heatsink) where the orange, blue, and purple wires from the torch lead
connect.
1
2
3
4
1Front panel
2Solenoid valve
3Hose fitting collar
4Gas hose
2
1
1J12 2Front panel

6Powermax30 Field Service Bulletin 805260
T30v Torch Lead Replacement
4. Remove the connector at J12 by pressing up on the tab in the connection slot with a small blade screwdriver and
then pulling the connector out toward the power supply’s front panel.
5. The white wire group and the red wire group from the torch lead are secured to studs in the power supply’s center
panel on the fan side of the power supply. Use an 8 mm (5/16 inch) nut driver to remove the nuts from the studs, and
slide the ring terminals off the studs.
6. On the inside of the front panel, unscrew the retaining nut on the torch lead’s strain relief so that the torch lead moves
freely.
7. Remove the torch lead by pulling the wires and gas supply line through the hole in the front panel. Remove the strain
relief from the front panel as you remove the lead.
Push tab toward connector
1
2
1White wire group 2Red wire group

Powermax30 Field Service Bulletin 805260 7
T30v Torch Lead Replacement
Remove the torch from the lead
1. Remove the consumables from the torch.
2. Place the torch on a flat surface with the left side of the handle facing up.
The left side of the handle is the side with the screws.
3. Remove the screws from the torch handle. Set the screws aside.
4. Being careful to keep the trigger spring from launching out of the handle, lift the left side of the handle away from the
torch.
5. While holding the spring in place, slide the trigger and spring up and out of the handle. Set them aside.
6. The torch body fits snugly into the right side of the handle. While holding the torch body in place, gently press the
right side of the handle away from the torch body to remove it.
CAUTION!
Wear eye protection, as the trigger spring can launch out of the handle.
1
2
3
4
5
6
7
8
9
1Right side of the handle
2Nut
3Torch head
4Plunger screw
5Trigger and spring
6Screws (5)
7Left side of the handle
8Start switch
9Cap-sensor switch

8Powermax30 Field Service Bulletin 805260
T30v Torch Lead Replacement
7. Slide the cap-sensor switch off the mounting post in the handle.
8. Lift the start switch off of the two mounting posts in the right side of the handle.
9. Use a screwdriver and a 6 mm (1/4 inch) nut driver (or adjustable wrench) to remove the screw that attaches the
torch power wire to the torch body. Set the nut and screw aside.
10. Disconnect the cap-sensor switch and start switch.
11 . Use an 8 mm (5/16 inch) wrench and a 10 mm (3/8 inch) wrench or 2 adjustable wrenches to loosen the gas fitting
that attaches the torch body to the torch lead. Set the old lead aside.
CAUTION!
Always use two wrenches to properly loosen and tighten the hex nuts and bolts mentioned in these
procedures.

Powermax30 Field Service Bulletin 805260 9
T30v Torch Lead Replacement
Install the torch onto the new lead
1. Thread the torch body onto the new torch lead with the 8 mm (5/16 inch) and 10 mm (3/8 inch) wrenches.
2. Connect the blue and orange wires from the new lead to the cap-sensor switch.
3. Connect the purple and orange wires into the start switch.
4. Use a screwdriver and a 6 mm (1/4 inch) nut driver (or adjustable wrench) to tighten the screw that attaches the
torch power wire to the torch body until the terminal is snug against the plunger.
5. Adjust the ring terminal so that the seam faces away from the screw and the cable rests about 15 degrees above
horizontal.
6. Lay the right side of the handle on a flat surface with the inside facing up.
7. Press the start switch onto the two mounting posts, and position the wires below the slot for the gas fitting.
8. Lay the cap-sensor switch’s wires and wire connector above the start switch with the wires positioned above the slot
for the gas hose’s fitting.
9. Press the torch body into the torch handle with the gas hose fitting’s flange aligned with the slot in the handle.
1
23
5
4
1Cap-sensor switch’s post hole
2Cap-sensor switch’s mounting post
3Trigger’s pivot hole
4Start switch’s posts
5Slot for the gas hose fitting’s flange

10 Powermax30 Field Service Bulletin 805260
T30v Torch Lead Replacement
10. Align the cap-sensor switch with the handle and the torch head so that the tip of the switch will not hit the torch head
as you put it in place. Gently press the cap-sensor switch onto its mounting post in the handle. The tip of the
cap-sensor switch should rest just above the cap-sense plunger on the torch head, and the post on the back of the
cap-sensor switch should slide into the hole in the handle.
11 . Verify that the plunger moves freely in the torch head. If it does not, check the angle of the ring connector for the
torch’s power cable.
12. Compress the trigger spring into the front half of the trigger. Slide the trigger and the spring into place.
13. Being careful that the handle does not pinch the wires, align the left half of the handle with the right half. Verify that
the trigger pivots are both located in the trigger pivot holes.
14. Install the handle screws.
15. Install the consumables.
1
2
3
4
1Cap-sensor switch’s mounting hole
2Cap-sensor switch
3Cap-sense plunger
4Cap-sensor switch’s mounting post

Powermax30 Field Service Bulletin 805260 11
T30v Torch Lead Replacement
Install the new lead onto the power supply
1. Locate the strain relief that comes preinstalled on the new torch lead. Loosen the strain relief nut from the strain relief
so that the nut can slide freely along the lead.
2. Remove the retention nut from the strain relief and from the torch lead. Set the retention nut aside.
3. Route the wires and gas supply hose for the new torch lead through the hole in the front panel.
4. From inside the front panel, slide the retention nut you set aside in step 2 over the torch lead wires and gas supply
hose. Tighten the retention nut onto the strain relief.
5. Position the torch lead so that the gas supply hose reaches the fitting on the bottom of the solenoid valve.
6. Push the torch gas supply hose into the fitting on the bottom of the solenoid valve. The hose goes in approximately
16 mm (0.65 inch).
1
2
3
4
1Retention nut (inside of front panel)
2Front panel
3Strain relief
4Strain relief nut (outside of front panel)

12 Powermax30 Field Service Bulletin 805260
T30v Torch Lead Replacement
7. Slide the ring terminal for the white wire group over the left stud (labeled “WHT” on the center panel).
8. Slide the ring terminal for the red wire onto the stud on the right (labeled “RED” on the center panel).
If you removed any other wires from the WHT and RED studs, reinstall them.
9. Use an 8 mm (5/16 inch) nut driver to tighten the nut on each stud.
10. Route the orange, blue, and purple wire group over the center panel with the wires resting in the notch in the panel.
11 . Tip the front panel away from the power supply. Press the connector into the TORCH START slot (J12) on the power
board.
12. Hold the torch lead wires and gas supply hose firmly in place, and tighten the torch lead’s strain relief nut onto the
strain relief.
CAUTION!
Do not allow the torch lead wires and gas supply hose to twist or bunch as you tighten the strain relief
nut onto the strain relief. Twisting the torch lead wires and hose can restrict gas flow and result in
operating errors.
1
2
5
4
3
1Notch for the orange, blue, and purple wire group
2Gas supply fitting
3White wire stud
4Red wire stud
5Hole for the torch lead and strain relief

Powermax30 Field Service Bulletin 805260 13
T30v Torch Lead Replacement
Install the component barrier and power supply cover
1. Position the component barrier so that the folded section will cover the top of the power board. The edge with the
long cutout and the two notches should align with the front panel; the edge with the three notches should align with
the rear panel.
2. Put the front-panel edge of the barrier in place first, then the rear-panel edge. The notches on each side of the barrier
should align with the ribs on the inside of the front and rear panels. As you slide the barrier into place, make sure the
bottom edge is between the wires at the bottom of the power board and the side of the plastic base.
The barrier will not fit in the same track with the power supply cover.
1
2
3
5
4
1Component barrier edge with long cutout and
two notches
2Front panel
3Track
4Rear panel
5Component barrier edge with three notches

14 Powermax30 Field Service Bulletin 805260
T30v Torch Lead Replacement
Install the power supply cover
1. Being careful not to pinch any wires, slide the cover onto the power supply. Align the bottom edges with the tracks,
and align the slot in the top of the cover with the tab on the front panel so that the louvers in the cover are in front of
the fan.
2. Realign the front panel with the power supply.
3. Realign the rear panel with the power supply, making sure the hole in the ground clip aligns with the screw holes in
both the panel and the power supply.
4. Position the handle over the holes in the top of the cover, and position the ends of the handle underneath the edges
of the panels.
5. Reinstall the two screws that attach the cover and handle with a torque setting of 23.0 kg-cm (20 inch-pounds).
6. Reconnect the gas supply and power cord, and set the power switch to ON (I).
12
3
1Cover slot
2Front panel
3Tab

Powermax30 Bulletin de service sur le terrain 805260 15
Remplacement du faisceau de torche T30v
Introduction
Objet
Décrit les étapes nécessaires au remplacement du faisceau de torche sur les torches manuelles T30v.
Outils et matériel requis
Tournevis Phillips®et TORX®assortis
Tournevis plat
Tournevis à douille de 8 mm
Tournevis à douille de 6 mm ou clé réglable
Clé de 10 mm
Contenu du kit 228113
AVERTISSEMENT !
UN CHOC ÉLECTRIQUE PEUT ÊTRE MORTEL
Avant tout entretien, débrancher l’alimentation électrique.
Tous les travaux nécessitant le retrait du couvercle de la source de courant
doivent être effectués par un technicien qualifié.
Pour des mesures de sécurité supplémentaires, se reporter au Manuel
de sécurité et de conformité (80669C).
Numéro de référence Description Quantité
229086 Faisceau : Torche manuelle T30v de 4,6 m 1
075504 Vis mécanique : Vis cruciforme à tête cylindrique bombée à
rondelle 4-40 X 5/16 CN S/Z
1
075503 Écrou de blocage : Écrou autobloquant 4-40 1

16 Powermax30 Bulletin de service sur le terrain 805260
Remplacement du faisceau de torche T30v
Remplacement du faisceau de torche
Retrait du couvercle de la source de courant et de la barrière de composant
1. Couper l’alimentation (OFF) (O), débrancher le cordon d’alimentation de la source de courant et débrancher
l’alimentation en gaz.
2. Retirer les deux vis de la poignée sur le dessus de la source de courant. Tirer doucement sur le panneau le plus
proche de la vis qui est retirée afin de maintenir une pression sur cette dernière. Une fois la vis pratiquement extraite,
incliner légèrement le tournevis pour faciliter l’extraction de la vis.
3. Basculer légèrement les panneaux d’extrémité avant et arrière de la source de courant de façon à en extraire les
bords de la poignée d’en dessous. Déposer la poignée et la mettre de côté avec les deux vis.
4. Continuer à incliner les panneaux vers l’extérieur pour dégager le couvercle de ses rails côté ventilateur. Soulever
ensuite le couvercle de la source de courant.
5. Déposer la barrière de composant du côté du panneau d’alimentation de la source de courant. Cette barrière est
flexible et peut être pliée légèrement pour être enlevée.
Barrière de composant

Powermax30 Bulletin de service sur le terrain 805260 17
Remplacement du faisceau de torche T30v
Déconnexion du faisceau de la source de courant
1. Pour retirer le tuyau de gaz de l’électrovanne, comprimer le collier du raccord du flexible et tirer ce dernier hors
du raccord.
2. Desserrer l’écrou du serre-câble situé sur l’extérieur du panneau avant.
3. Éloigner délicatement le panneau avant de la source de courant. Repérer le connecteur à trois broches sous
le logement TORCH START (J12) sur le circuit imprimé d’alimentation, (situé sur le côté faisant face au dissipateur
thermique), où les fils orange, bleu et violet du faisceau de torche se raccordent.
1
2
3
4
1Panneau avant
2Électrovanne
3Collier de raccord de flexible
4Tuyau de gaz
2
1
1J12 2Panneau avant

18 Powermax30 Bulletin de service sur le terrain 805260
Remplacement du faisceau de torche T30v
4. Retirer le connecteur à J12 en appuyant sur la languette qui se trouve dans le logement de connexion à l’aide d’un
petit tournevis plat et en tirant par la suite le connecteur à l’extérieur en direction du panneau avant de la source
de courant.
5. Le groupe de fils blancs et le fil rouge du faisceau de torche sont fixés sur des goupilles du panneau central de la
source de courant du côté ventilateur de la source de courant. À l’aide d’un tournevis à douille de 8 mm, retirer les
écrous des goupilles et faire glisser les cosses rondes hors des goupilles.
6. À l’intérieur du panneau avant, dévisser l’écrou de retenue du serre-câble du faisceau de torche de façon à ce que
le faisceau de torche puisse se déplacer librement.
7. Retirer le faisceau de torche en tirant les fils et la conduite d’alimentation en gaz au travers du trou sur le panneau
avant. Lors du retrait du faisceau, déposer le serre-câble du panneau avant.
Pousser la languette vers le connecteur.
1
2
1Groupe de fils blancs 2Groupe de fils rouges

Powermax30 Bulletin de service sur le terrain 805260 19
Remplacement du faisceau de torche T30v
Retirer la torche du faisceau.
1. Retirer les consommables de la torche.
2. Placer la torche sur une surface plane, en plaçant le côté gauche de la poignée vers le haut.
Le côté gauche de la poignée est le côté avec les vis.
3. Retirer les vis de la poignée de torche. Mettre les vis de côté.
4. En faisant attention de ne pas laisser le ressort de la gâchette sauter de la poignée, soulever le côté gauche
de la poignée de la torche.
5. Tout en maintenant le ressort en place, faire glisser la gâchette et le ressort vers le haut pour les extraire
de la poignée. Les mettre de côté.
6. Le corps de la torche se loge parfaitement dans le côté droit de la poignée. Tout en tenant en place le corps de la
torche, appuyer doucement sur le côté droit de la poignée pour l’enlever du corps de la torche.
ATTENTION !
Porter une protection pour les yeux, le ressort de la gâchette peut sauter de la poignée.
1
2
3
4
5
6
7
8
9
1Côté droit de la poignée
2Écrou
3Tête de torche
4Vis du plongeur
5Gâchette et ressort
6Vis (5)
7Côté gauche de la poignée
8Interrupteur de démarrage
9Contacteur de détection de buse

20 Powermax30 Bulletin de service sur le terrain 805260
Remplacement du faisceau de torche T30v
7. Retirer le contacteur de détection de la buse en le glissant hors des tiges de montage de la poignée.
8. Soulever l’interrupteur de démarrage des deux tiges de montage sur le côté droit de la poignée.
9. À l’aide d’un tournevis et d’un tournevis à douille de 6 mm, retirer la vis qui fixe le câble électrique au corps
de la torche. Mettre de côté l’écrou et la vis.
10. Débrancher le contacteur de détection de la buse et l’interrupteur de démarrage.
11 . À l’aide de clés de 8 mm et de 10 mm ou de deux clés réglables, desserrer le raccord de gaz qui relie le corps
de la torche au faisceau de torche. Mettre l’ancien faisceau de côté.
ATTENTION !
Toujours utiliser deux clés pour desserrer et serrer correctement les écrous et boulons hexagonaux
mentionnés dans ces procédures.
Other manuals for T30v
1
Table of contents
Languages:
Other Hypertherm Flashlight manuals

Hypertherm
Hypertherm Duramax 75 Degrees Reference manual

Hypertherm
Hypertherm Duramax Hyamp Series User manual

Hypertherm
Hypertherm RT60 User manual

Hypertherm
Hypertherm Duramax Series Reference manual

Hypertherm
Hypertherm SmartSYNC Robotic Torch User manual

Hypertherm
Hypertherm powermax65 User manual

Hypertherm
Hypertherm Duramax User manual

Hypertherm
Hypertherm XPR Short Torch with Integrated Lead User manual

Hypertherm
Hypertherm 059664 Reference manual

Hypertherm
Hypertherm HRT User manual